Arrow Group Industries PENILASER P15C User manual

IMPORTANT: Read before Using
P15C
www.arrowfastener.com
1WARRANTY
LIMITED
YEAR
LASER DISTANCE MEASURE
15M
50FT
Questions,problems, missing parts?
Please contact our customer service department at
1-800-776-228 or email us at

1
EN
CAUTION:
ARROW P15C
If you have no such manual, or it is in the wrong
language, please ask your agency for an appropriate
copy.
The product is permitted to use for skilled persons
only.
Do not use the product before you
have studied the User Manual on the
enclosed CD or on our Homepage.
Use of controls or adjustment or performance of
procedures other than those specified herein may
result in hazardous radiation exposure
• Do not attempt to modify the performance of
this laser device in any way. This may result
in a dangerous exposure to laser radiation.
• Do not operate the tool outdoors.
• Do not attempt to repair or
disassemble the laser-measuring
tool. If unqualified persons attempt
to repair this product, serious injury
may occur. Any repair required on
this laser product should be
performed only by qualified service
personnel.
• Do not stare into the laser beam or
direct it towards other people
unnecessarily.
• Don't dazzle other individuals.
• Looking directly into the beam
with optical aids can be hazardous.
• Do not operate the product in
explosion hazardous areas or in
aggressive environments.
• Only use chargers recommended
by the manufacturer to charge
the batteries.
• Keep extremities in a safe
distance from the moving parts.
• Watch out for erroneous
measurements if the product is
defective or if it has been
dropped or has been misused or
modified.
• Carry out periodic test
measure-ments. Particularly before,
during
and after important measure-
ments.
• The product and batteries must
not be disposed of with
household waste.
• It is a Class 2 laser product in accordance
with IEC 60825-1:2014
WARNING:
Laser radiation. Do not stare into beam. Class 2 Laser
product. Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser Notice No.50,
dated June 24, 2007
IEC 60825-1: 2014
<1.0mW @ 620-690nm
Table of Contents
Safety Instructions
Symbols used
Permitted use
Prohibited use
Hazards in use
Limits of use
Areas of responsibility
Electromagnetic Compatibility (EMC)
FCC statement (applicable in U.S.)
Laser classification
Technical Data
Troubleshooting
Care
Disposal
Warranty
Important Safety Instructions
Instrument Set-up
Overview
Display
Insert batteries
Operations
Switching ON/OFF
Measuring single distance
Continuous measuring
- - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - - - - - - - 5
- - - - - - - - - - - - - - - - 6
- - - - - - 6
- - - - - - - 6
- - - - - - - - - - - - - - - - - 6
- - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - - - - - - - - - - - - - - - - - 4
- - - - - - - - 1
- - - - - - - - - - - - - - - - - 2
- - - - - - - - - - - - - - - - - - - - - - - - 2
- - - - - - - - - - - - - - - - - - - - - - - - - 2
- - - - - - - - - - - - - - - - - - - - 2
- - - - - - - - - - - - - - - - - - - - - - 3
- - - - - - - - - - - - - - - - - - 3
- - - - - - - - - - - - - 3
- - - - - - - - - - - - - - - 3
Important Safety
Instructions

2
EN
Instrument Set-up
Overview Display
Units
i
ARROW P15C
The safety instructions and the user manual should
be read through carefully before the product is
used for the first time.
The person responsible for the product must
ensure that all users understand these directions
and adhere to them.
Display
On / Measure /
Units
Battery
Insert batteries
Change
batteries when
battery symbol
is flashing.

3
EN
ARROW P15C
Continuous Measuring
1 2
29’08”
3
i
Target surfaces: Troubleshooting can occur
when measuring to colourless liquids, glass,
styrofoam or semi-permeable surfaces or when
aiming at hight gloss surfaces. Against dark
surfaces the measuring time increases.
Aim active laser at target.
Operations
FFO/NOgnihctiwS
OFF
Device is turned
OFF.
5 sec
i
If no key is
pressed for
120 sec, the
device
switches off
automatically.
Unit setting
ON
0.000 m
0' ''00 1/16
Switch between the
following units:
3 sec

EN
4
ARROW P15C
Troubleshooting
• Clean the device with a damp,
soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning
agents or solvents.
Disposal
CAUTION
Warranty
* Favourable conditions are: white and diffuse reflecting
target (white painted wall), low background illumination and
moderate temperatures.
** Unfavourable conditions are: targets with lower or higher
reflectivity or high background illumination or temperatures
at the upper or lower end of the specified temperature
range.
*** Tolerances apply with a confidence level of 95%.
Potential issue table
ISSUE CAUSE ACTION
Hardware protection
after shocking Take out batteries
and insert again
Low battery Replace with
new batteries
Failure to
switch on
All dashes shows
on display
Insufficient
On/Measure/Units
button press
Press the
On/Measure/Units
button firmly
Received signal
too weak/
Measuring time too long
Change target surface
(e.g. white paper)
Received signal
too strong
(target is too reflective)
Change target surface
Ambient light
is too strong Shadow target area
(e.g. white paper)
The object is out
of rated range Measure within
rated range
Beam is moved too fast Move the measuring
tool slowly
Care
Technical Data
Flat batteries must not be disposed of
with household waste. Care for the
environ-ment and take them to the
collection points provided in accordance
with national or local regulations.The
product must not be disposed with
household waste.Dispose of the
product appropri-ately in
accordance with the national
regulations in force in your country.
Adhere to the national and country
specific regulations.Product specific
treatment and waste management can be
downloaded from our homepage.
The Arrow P15C has a one-year
warranty.
For further information on this, contact
your dealer.
This warranty is void if product is used for
commercial purposes. This warranty is
not transferable and does not cover
products damaged by misuse, neglect,
accident, alterations or use and
maintenance other than that specified in
the owner's manual. This warranty does
not apply to any expendable parts that
can wear from normal use. This warranty
excludes any accessories.
General
1.7 - 50 ft***
0.5 - 15 m
1.7 - 26 ft***
0.5 - 8 m
± 1/4 in***
± 6 mm
± 1/4 in***
± 6 mm
Smallest unit displayed 1/16 in
1 mm
Laser class 2
Laser type 620-690 nm, < 1 mW
Power OFF automatically after 120 s
Continuous measuring yes
Dimension (H x D x W)
up to 3h
2 x 1.5V (AAA)
Weight
(without batteries)
Temperature range:
- Storage
- Operation
14 to 140 °F
-10 to 60 °C
32 to 104 °F
0 to 40 °C
6.02 x 0.65 x 0.92 IN
153 x 16.4 x 23.4 mm
36.6 g / 1.29 oz
Battery service life in
measuring operation, approx.
Batteries
Range with favourable
conditions *
Range with unfavourable
conditions **
Accuracy with
favourable conditions *
Accuracy with
unfavourable conditions **

EN
Safety Instructions
Symbols used
WARNING
CAUTION
Hazards in use
WARNING
CAUTION
WARNING
Limits of use
i
i
ARROW P15C
5
Permitted use
•
Measuring distances
Prohibited use
•
Using the product without instruction
•
Using outside the stated limits
•
Deactivation of safety systems and
removal of explanatory and hazard
labels
•
Opening of the equipment by using
tools (screwdrivers, etc.)
•
Carrying out modification or conversion
of the product
•
Use of accessories from other
manufac-turers without express
approval
•
Deliberate dazzling of third parties;
also in the dark
•
Inadequate safeguards at the
surveying site (e.g. when measuring on
roads, construction sites, etc.)
•
Deliberate or irresponsible behaviour
on scaffolding, when using ladders,
when measuring near machines which
are running or near parts of machines
or installations which are unprotected
•
Aiming directly in the sun
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Watch out for erroneous measurements if
the instrument is defective or if it has
been dropped or has been misused or
modified. Carry out periodic test
measurements.Particularly after the
instrument has been subject to abnormal
use, and before, during and after
important measurements.
Never attempt to repair the product
your-self. In case of damage, contact a
local dealer.
Changes or modifications not expressly
approved could void the user’s authority
to operate the equipment.
Refer to section "Technical data".The
device is designed for use in areas
ently habitable by humans. Do not use
the product in explosion hazardous areas
or in aggressive environments.
The symbols used have the following
meanings:
Indicates a potentially hazardous
situation or an unintended use which, if
not avoided, will result in death or serious
injury.
Indicates a potentially hazardous
situation or an unintended use which, if
not avoided, may result in minor injury
and/or appre-ciable material, financial
and environ-mental damage.
Important paragraphs which must be
adhered to in practice as they enable
the product to be used in a technically
correct and efficient manner.

Safety Instructions
6
EN
Areas of responsibility
Responsibilities of the person in
charge of the instrument:
Electromagnetic Compatibility
(EMC)
WARNING
ARROW P15C
Laser classification
The device produces visible laser
beams, which are emitted from the
instrument: It is a Class 2 laser product
in accordance with:
Do not stare into the laser beam or direct
it towards other people unnecessarily.
Eye protection is normally afforded by
aversion responses including the blink
reflex.
Laser Class 2 products:
IEC60825-1 : 2014“Radiation safety
of laser products”
WARNING
Looking directly into the beam with
optical aids (e.g. binoculars, telescopes)
can be hazardous.
CAUTION
Looking into the laser beam may be
hazardous to the eyes.
Wavelength
620 - 690 nm
Maximum radiant output power
for classification
< 1 mW
• To understand the safety instructions
on the product and the instructions in
the User Manual.
• To be familiar with local safety
regula-tions relating to accident
prevention.
• Always prevent access to the product
by unauthorised personnel.
Responsibilities of the manufacturer
of the original equipment:
Hangzhou Great Star Industrial Co., Ltd.
No.35 Jiuhuan Road, Jiubao Town,
Hangzhou 310019, China
Internet: www.arrowfastener.com
The company above is responsible for
supplying the product, including the User
Manual in a completely safe condition.
The company above is not responsible for
third party accessories.
• Reorient or relocate the receiving
antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet
on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
instal-lation.This equipment generates,
uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may
cause harmful inter-ference to radio
communications.However, there is no
guarantee that inter-ference will not occur
in a particular instal-lation. If this
equipment does cause harmful
interference to radio or television
reception, which can be determined by
turning the equipment off and on, the user
is encouraged to try to correct the
interfer-ence by one or more of the
following measures:
The device conforms to the most stringent
requirements of the relevant standards
and regulations. However, the possibility
of causing inter-ference in other devices
cannot be totally excluded.
FCC statement (applicable in U.S.)
Please contact our customer service department at
1-800-776-228 or email us at
Table of contents
Popular Measuring Instrument manuals by other brands

Anritsu
Anritsu MP1632C Service manual

WEHRLE
WEHRLE WECOUNT MTK-OZM Quick guide for installation & use

Delta
Delta DVP04TC-H2 instruction sheet

McIntosh
McIntosh MPI 4 owner's manual

PCB Piezotronics
PCB Piezotronics CS625B11 Installation and operating manual

Synrad
Synrad Firestar TI Series quick start guide

Schaller
Schaller humimeter PM5 operating manual

PCB Piezotronics
PCB Piezotronics 3741B1250G Installation and operating manual

Ludlum Measurements
Ludlum Measurements 30 Series manual

Contrec
Contrec 104A manual

Super Systems
Super Systems DPC2500 product manual

Nidec-Shimpo
Nidec-Shimpo FG-7000T Operation manual