Arrowhead Alarm Products Elite Control TRX PIR User manual


WIRELESS SUPERVISEDPIR
MOTIONDETECTOR
WithPETIMMUNITYupto27Kg
INSTALLATIONINSTRUCTIONS
P/N7101504REV. AA.Y.
PRODUCT DESCRIPTION 3
The DFWis abatterypoweredpassiveinfrared
motion detectorwithabuilt-intransmitter.
Thistransmittercan be used inavarietyofmotion
detection applications.When the passiveinfrared
sensordetectsmotion initsfieldof view, the
transmittersendsawirelesssignaltothe re-
ceiver.
The DFWsendsthree different signals: “Alarm”,
“Low Battery”and “Tamper”.
Inatypicalinstallation, the motion detectoris wall
mounted indoors.
The sensorwillmonitorthe infrared levelinits
detection pattern.If the levelincreasesorde-
creasesrapidly(aswhen aperson movesthrough
the area)the transmittertriggers,sending an
alarmsignaltothe receiver.
The unit is powered froma3volt lithiumbattery.
The lifeof the batterydependsupon theactivityin
the area wherethe detectoris installed.When the
batteryis low, alow batterysignalwill be sent to
the receiver.
If the detectorcoveris removed, the tamperswitch
triggersthe transmittertosend an alarm.
The DFWhasaunique Automatic PowerSaver
(APS)circuit designed toconservebatterylife.
ThisAPS circuit rearmsthe transmitter2minutes
afterthe last movement hasbeen detected.
FEATURES DETECTIONPATTERN TYPICAL INSTALLATION
Low current ASIC PIR technology
Powered bya3volt lithiumbattery
Built inAutomatic PowerSaver(APS)
Low batteryreport
Tamperreport
Walktest mode 1forPIR coverage
Walktest mode 2forRFsignal
Pet immune up to27Kg
AdjustableMounting Bracket
2Transmission modes, powersave(normal)
and Frequent(test)
Select the mounting location sothat anintruder
willcrossthe beamsof the selected pattern.
Sincethe detectoris awireless transmitter, do not
install it inareaswherelarge metalobjectscould
interferewiththe transmission of signals.
Avoidmounting thedetectorasfollows:
Facing adoorwithawireless door/window
transmitter.
Facing direct sunlight.
Facing areasthat maychange temperature
rapidly.
Facing an airduct orareaswithsubstantial
airflows.
Onornearmetalsurfaces.
The DFWperformsbest when provided witha
constant and stableenvironment.
REMOVAL OF FRONTCOVER MOUNTINGDETECTORBASE
1.Toremovethe frontcover, unscrew the holding
screw and gentlyraisethe front cover.
2.Toremovethe PCB, carefullyunscrew the
holding screw located on the PCB.
3.Knockout the desired holesforinstallation.
4.Mount thedetectorbasetothewall, corner.
5.Reinstall the PCBbyfullytightening thehold-
ing screw.
6.Install the batteryinthebatteryholderobserv-
ing the polarity.
7. Replacethe coverbyinserting it backinthe
appropriateclosing pinsand screw inthe
holding screw.
SETTING-UPTHEDETECTOR LAYOUT
Setting theSensitivityAdjustment
PIR AdjustPotentiometer
Usethis potentiometertoadjust the detection
sensitivitybetween 68%and 100%(factoryset
to84%). Rotatethe potentiometerclockwiseto
increasesensitivity. Rotatethepotentiometer
counter-clockwisetodecreasesensitivity.
Pulse Width Switch
The sensitivityadjustment switchsetsup the
detectorfornormalorharshenvironment condi-
tions.
Position 1= Normal
Position AUTO= Harsh
The “1”position setting is fornormaloperation.
The “AUTO”position setting is forharshenviron-
ment locationswithairdrafts.
SETTINGTHEPETIMMUNITYSWITCH
33LB= 15KGPETIMMUNITY
60LB= 27KGPETIMMUNITY
Setting Transmission Mode
The transmission mode is changed bymoving
the jumperpinson the TRANSboard, fromone
option totheother.
Normal:
When the IR motion is detected, anRFtrans-
mission willbe sent, then the DFWwill save
powerand not transmit foranother2minutes.
Test:
Inthis mode everytimeIR motion is detected,
an RFtransmission will be sent. This mode will
not timeout, making it idealforadoorminder
situation.
1AUTO
PULSE
15Kg27Kg
PET
PIR
SENSITIVITY
ADJUSTMENT
DETECTION
LED
TRANSMISSION
LED
TRANSMISSION
MODE
NORMALTEST
TAMPER
SWITCH
TEST
BUTTON
AvailableinTRX 918Mhz
TRX PI R

WALKTEST ALARMTRANSMISSIONTEST WALLINSTALLATION
TESTPUSHBUTTON
The Test Pushbutton is located below the
Tamperswitch.
Thisbutton is used toactivateWalktest mode 1
and 2.
WALKTESTMODE1(PIRCOVERAGE)
Press the Test Pushbutton forashort time(less
than 1second). This activatesthe LED totrigger
withIR detection only, without an RFtransmis-
sion, for1minute. Allowing youtowalk around
and checkthePIR coverage area &sensitivity.
WALKTESTMODE2(RFSIGNAL)
Pressing the Test Pushbutton forat least 4
seconds, (until the LED flashes4times)will
activateboththe LED andan RFtransmission
withIR detection, for1minute.
Note. ThePIR TRANSJumpermustbesetto Normal
mode, no RFtransmission willbesentifsetto Test
mode
BATTERYTYPE BATTERYINSTALLATION
A3-volt lithiumbatterypowersthe unit.
The batteryprovidesabout 3yearsof continuous
operation (depending on the amountof activity).
If the batteryreachesafactorypreset low level, a
LOWBATTERYsignalwill be sent. Fromthis
moment, the detectorremainsoperationalfor
another30daysgivingenough timetoreplace
the battery.
Thebatterymustbereplaced
bya3voltlithiumbattery
Models:DL123ADURACELL INC.
CR123ASANYO
ELC.CR123AGP
Oranequivalent.
1. Removethefront cover.
2. Takeout theoldbattery.
3. Besuretoinsert thebatterycorrectlywith
the PLUSterminalof the batterytothe
right-hand side.
CompatibleReceivers:
TECHNICALSPECIFICATION WARRANTY
EventTransmissionAlarm,Test, LowBattery
Transmission ProtocolFreelinkSupervised
DetectionMethodQuadElementPIR(ASICBased)
DetectionSpeed1~5ft/sec. (0.3~1.5m/sec)
LensType SphericalHardLens
DetectionCoverage90°50ft x50ft (15mx15m)
Environment Condition SwitchforNormalorHarshselection
BatteryLithium. 3VType:xx123Size:2/3AA
Current ConsumptionStandby: 8-10mATransmission: TBD
PowerSaving APS (AutomaticPowerSaver)
InstallerTest ModesLEDIndicator(RF &Optic)
Walktest&Alarmtransmission test
OperationTemperatureRange-10°Cto+60°C
Dimensions4.8”x2.5”x1.45”(122mmx63mmx37mm)
Weight(inc. battery)3.88Oz(110gr)
Enabling&AssigningRadioZones
Enabling &AssigningradiozonesarebothsetupunderaddressP122E.
P122 E (1-16)E (TurnOnOptions 1& 5)
Zone1to 16 thatyouwishto Change
RadioDetector Type
The DFW transmits intheFreelinkprotocol,youhavetheoptionto select:Supervised(3)orUn-
Supervised(4)default.underaddress P127E.
* InSupervisedmodeevery15 minutesthe detectorwill communicatewiththepanel,confirming it
is still operating and the battery is good.
P127 E (1-16)E3E
Zone1to 16 thatyouwishto Change
LearningRadioDevice
Insertthe 3volt batteryinto the DFW,thenHold Downthe TamperSwitch.
Nowgoto address P164Eandchooseazone slot 1-16 and Enter
Zoneslot 1to 16 thatyouwishto learninto.
P164 E (1-16)E=the keypad should startbeeping.
Now ReleasetheTamperSwitch,theTXLEDshouldcomeOn.
=the keypad should stop beeping.
(Forothercontrolpanelspleasefollow themanufacturesinstallationmanual)
CEILINGINSTALLATION
TRX Tranceiver
Transmission Frequency 918Mhz
The DFWwillworkon: ESL-2, Crow Runner
RX-DEC/FWwith a compatible Receiver.
PROGRAMMINGDFW INTOANESL-2 or Crow Runner CONTROL PANEL COMPATIBLERECEIVERS/ DEVICES
Table of contents