TECHNICAL SPECIFICATIONS
ENGLISH
UNIDIRECTIONAL OPENING SENSOR
FOR AUTOMATIC DOORS*
DESCRIPTION
1. main connector
2. antenna
3. LEDs
4. push buttons
5. cover
Specifications are subject to changes without prior notice.
Measured in specific conditions.
This user’s guide is an informative document and
can not be seen as a commitment of result.
Technology: Microwave
Transmitter frequency: 24.15 GHz
Transmitter radiated power: < 20 dBm EIRP
Transmitter power density: < 5 mW/cm²
Detection mode: Motion
Max. detection range: Wide : 4 m × 2m | Narrow : 2 m × 2.2 m @2.2 m high
Min. detection speed: 5 cm/s
Supply voltage**: 12V to 24V AC +/- 10% (50 - 60 Hz) ; 12V to 24V DC +30% / -10%
Max power consumption: < 1 W
Output**:
Max. switching voltage:
Max. switching current:
Solid-state relay (free of polarity)
30V AC / 42V DC
100mA (resistive)
Mounting height: From 1.8 m to 4 m
Degree of protection: IP54 (IEC/EN 60529)
Temperature range: From -20 °C to + 55 °C
Dimensions: 120 mm (L) × 50 mm (H) × 50 mm (W)
Tilt angles: 0° to 90° vertical; -30° to +30° lateral
Material: ABS
Weight: 120 g
Cable length: 2.5 m
User’s Guide for software version SW 0100 and higher.
(refer to tracking label on product).
** External electrical sources must be within specified voltages, max 15W and ensure double insulation from primary voltages.

2
1
2
3
2.2 m
45°
30°
15°
23
12
14
2
1
POWER
POWER
OPENING
OPENING
2.2 m
FIELD ANGLE ADJUSTMENTS
MOUNTING & WIRING
Insert the screwdriver on the left
or the right notch of the sensor
and twist it to remove the cover.
Adjust the lateral antenna angle. Adjust the vertical antenna angle.
TIPS
Apply the mounting
template. Drill 1 hole
(Ø 5 - 7 mm Ø 1/4’’) for the
cable and pull it through.
Drill 2 holes (Ø 3 mm Ø
1/8’’) for the screws.
First, position the cable
according to the hole in the
wall. To avoid crushing it,
you can use the dedicated
cable path. Next, fix the
sensor firmly.
Avoid proximity to neon
lamps or moving objects.
Do not cover the sensor.Avoid vibrations.
APPLICATIONS
Wall mounting above sliding or
revolving door.
Ceiling mounting in front of door
(sliding, revolving or swing doors).
Connect to the door
controller:
1 - RED - POWER SUPPLY
2 - BLACK - POWER SUPPLY
3 - YELLOW - OPENING
4 - YELLOW - OPENING.
Mounting on door axis (swing
doors).
Plug the connector
accordingly.
OPENING THE SENSOR
Mount the sensor securely.

3
NC
NO
4
XXS XS S > > > > L XL XXL
> > > >>
X 1
or
... S, XS, XXS ... L, XL, XXL
2.2m
2.2m
X 1
OK
OK
< 3 m > 3 m
0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
SETTINGS
FIELD SIZE
DETECTION
MODE
OUTPUT
CONFIG.
bi = two-way detection; uni = one-way detection
towards sensor;
uni PRM = one-way detection also of people with
reduced mobility;
uni AWAY = one-way detection away from sensor.
bi uni uni
PRM
uni
AWAY
PRM &
AWAY
RESETTING TO
FACTORY VALUES
HOLD-OPEN
TIME
DOOR
CONTROL auto open closed open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
IMMUNITY
FILTER low normal high highest
The access code (1 to 4 digits) is recommended to set sensors installed close to each other.
SAVING AN ACCESS CODE:
DELETING AN ACCESS CODE:
Once you have saved an access code, you always need to enter this code to unlock the sensor. If you forget the
access code, cut and restore the power supply. During 1 minute, you can access the sensor without introducing
any access code.
ACCESS CODE PUSH BUTTONS
REMOTE CONTROL
FACTORY VALUES:
< 3 m > 3 m
MOUNTING
HEIGHT
FIELD SIZE
IMMUNITY
FIELD SHAPE
long push (2sec)
ENTER increase
or
decrease
long push (2sec)
ENTER wide
or
narrow
EXIT
long push (2sec)
EXIT
long push (2sec)
FIELD SHAPE widenarrow

4
1
1
1
2
2
3
4
5
1
2
1
1
1
1
2
2
1
3
3
1
2
1
BEA SA | LIEGE Science Park | Allée des Noisetiers, 5 - 4031 ANGLEUR [BELGIUM] | T +32 4 361 65 65 | F +32 4 361 28 58 | [email protected] | www.beasensors.com
+
©BEA | Original instructions | 47.0400 / V3 - 04.22-
TROUBLESHOOTING
The door remains
closed.
The LED is OFF.
The sensor power is off. Check the wiring and the power supply.
The door does not
react as expected.
The door does not
react as expected.
The door opens
and closes
constantly.
The LED
flashes quickly
after unlocking.
The sensor does
not respond to the
remote control.
Improper output
configuration on the sensor.
The wire to the antenna is
disconnected or damaged.
The sensor is disturbed
by the door motion or
vibrations caused by the
door motion.
The sensor needs an access
code to unlock.
Batteries in the remote
control are weak or
installed improperly.
The door opens for
no apparent reason.
It rains and the sensor
detects the motion of the
rain drops.
Remote control badly
pointed.
Change the output configuration setting on
each sensor connected to the door operator.
Check if the wire to the antenna is crushed or cut.
Replace sensor.
Make sure the sensor is fixed properly.
Make sure the detection mode is unidirectional.
Increase the antenna angle.
Increase the immunity filter.
Reduce the field size.
Change the antenna angle.
Decrease the field size.
Increase the immunity filter.
Enter the right access code.
If you forgot the code, cut and restore the power
supply to access the sensor without access code.
Change or delete the access code.
Check and change the batteries if necessary.
Point the remote control towards the sensor.
Make sure the detection mode is unidirectional.
Increase the immunity filter.
In highly reflective
environments, the sensor
detects objects outside of its
detection field.
In airlock vestibules,
the sensor detects the
movement of
the opposite door.
Change the antenna angle.
Adjust the field shape.
Increase the immunity filter.
The door control setting (F2)
is set to value 3 (closed).
Change the door control setting (F2) to value 1
(automatic).
This product should be disposed of separately from unsorted municipal waste.
PLEASE KEEP FOR FURTHER USE - DESIGNED FOR COLOUR PRINTING
The service mode deactivates the detection during 15 minutes and can be useful during an installation, a
mechanical teach-in of the door or maintenance work.
To enter the service mode, push on the button for at least 4 seconds. When the sensor is in service mode,
the LEDs are off.
To exit the service mode, push any button.
SERVICE MODE
BEA hereby declares that the Eagle Artek is in compliance with European Directives 2014/53/EU (RED) and
2011/65/EU (RoHS).
The complete declaration of conformity is available on our website.
OR
> 4 seconds
RESETTING TO FACTORY VALUES:
Popular Accessories manuals by other brands

turck
turck NCLS Series Instructions for use

AMX
AMX Rack Rail Kit MMS Servers installation guide

Royal Catering
Royal Catering RCWI-88L user manual

Honeywell
Honeywell IntelliSense IS25100TC installation instructions

Wasserstein
Wasserstein Smart Window Vibration Sensor user manual

Scott
Scott MOTORSPORTS GOGGLE user manual