Aruba 1 Series User manual

Aruba IntroSpect Analyzer 1XXX Series
Quick Start Guide
Preface
Table 1 lists the documents detailing the setup and installation process for the IntroSpect Analyzer appliances.
Refer to these documents in the order listed.
Step Category Document
1 Quick Start Guide Aruba IntroSpect Analyzer 1XXX Series Quick Start Guide*
2 Appliance Setup Guide Aruba IntroSpect Analyzer Appliance Setup Guide
3 Configuration Guide Aruba IntroSpect Log Sources Configuration Guide**
Aruba IntroSpect Analytics Configuration Guide**
Table 1: Related Documents
*This document.
**Future document release.
Figure 1 IntroSpect Analyzer 1XXX Series – Front View
This Quick Start Guide applies to the following models:
nAnalyzer Models with Copper Management Port
nAnalyzer Models with Fiber Management Port
Model Name JSKU #
AI-ANA-1000-AN Aruba IntroSpect Analyzer 1000 Analyzer Node Appliance (All HDD) JZ265A
AI-ANA-1000-CN Aruba IntroSpect Analyzer 1000 Compute Node Appliance (All HDD) JZ266A
AI-ANA-1500-AN Aruba IntroSpect Analyzer 1500 Analyzer Node Appliance (with SSD) JZ269A
AI-ANA-1500-CN Aruba IntroSpect Analyzer 1500 Compute Node Appliance (with SSD) JZ270A
Table 2: Analyzer Models with Copper Management Port
Revision 3 | June 2018 1

Model Name JSKU #
AI-ANA-1050-AN Aruba IntroSpect Analyzer 1050 Analyzer Node Appliance (All HDD) JZ267A
AI-ANA-1050-CN Aruba IntroSpect Analyzer 1050 Compute Node Appliance (All HDD) JZ268A
AI-ANA-1550-AN Aruba IntroSpect Analyzer 1550 Analyzer Node Appliance (with SSD) JZ271A
AI-ANA-1550-CN Aruba IntroSpect Analyzer 1550 Compute Node Appliance (with SSD) JZ272A
Table 3: Analyzer Models with Fiber Management Port
Analyzer Models with Copper Management Port
This section applies to models: AI-ANA-1000-AN | AI-ANA-1000-CN | AI-ANA-1500-AN | AI-ANA-1500-CN
Racking the Analyzer Appliance
Use the following steps to install Analyzer:
1. Locate Rails
2. Attach Outer Rails and Install Chassis
Locate Rails
1. The inner rail is pre-installed on the chassis.
2. Outer rail to be installed on the rack.
Figure 2 Locate Rails
2IntroSpect Analyzer 1XXX Series | Quick Start Guide

Attach Outer Rails and Install Chassis
1. Attach the outer rail to rack.
2. Align Analyzer's inner rails with the outer rails and slide unit until the lock clicks.
3. Install all other nodes similarly.
Figure 3 Attach Outer Rails and Install Chassis
Connecting and Configuring Analyzer Nodes
Use the following steps to configure Analyzer:
1. Connect Cables
2. Follow Wiring Diagram
3. Configure the Analyzer Cluster
Connect Cables
1. Power Supply (2)
2. IPMI LAN Port
3. ETH0: Mgmt Port
4. ETH1: Config Port
Figure 4 Analyzer Models with Copper Management Port – Back View
4
21 3
IntroSpect Analyzer 1XXX Series | Quick Start Guide 3

Follow Wiring Diagram
Use the following steps to connect the Analyzer appliances:
1. Connect ETH0 of AN Node to the corporate network. The Analyzer UI can be accessed from this network.
2. Connect ETH1 of AN Node to any port on the 10G switch.
3. Connect ETH0 of each Compute Node to any port on the 10G switch.
Use ethernet cables capable of 10G speeds.
All the ports on the 10G switch serve the same purpose. It does not matter which ones are used.
Refer to Figure 4 for a detailed back view of the appliance as you connect the cables in the wiring diagram.
Figure 5 Wiring Diagram for Analyzer Models AI-ANA-1000-AN, AI-ANA-1000-CN, AI-ANA-1500-AN, AI-ANA-
1500-CN with Copper Management Port
Compute Node N
Compute Node 2
Compute Node 1
AN Node
ETH0 ETH1
ETH0
ETH0
ETH0
24 Port 10G Switch – Part # JZ273A
To
Corporate
Network
Configure the Analyzer Cluster
1. Connect a laptop to a free port on the 10G switch.
2. Open a browser instance and connect to: https://192.168.1.254:8443.
3. Complete the IntroSpect setup wizard.
For detailed setup instructions, see the IntroSpect Appliance Setup Guide.
4IntroSpect Analyzer 1XXX Series | Quick Start Guide

Analyzer Models with Fiber Management Port
This section applies to models: AI-ANA-1050-AN | AI-ANA-1050-CN | AI-ANA-1550-AN | AI-ANA-1550-CN
Racking the Analyzer Appliance
Use the following steps to install Analyzer:
1. Locate the Rails
2. Attach Outer Rails and Install Chassis
Locate the Rails
1. The inner rail is pre-installed on the chassis.
2. Outer rail to be installed on the rack.
Figure 6 Locate Rails
Attach Outer Rails and Install Chassis
1. Attach the outer rail to rack.
2. Align Analyzer's inner rails with the outer rails and slide unit until the lock clicks.
3. Install all other nodes similarly.
Figure 7 Attach Outer Rails and Install Chassis
IntroSpect Analyzer 1XXX Series | Quick Start Guide 5

Connecting and Configuring Analyzer Nodes
Use the following steps to configure Analyzer:
1. Connect Cables
2. Follow Wiring Diagram
3. Configure the Analyzer Cluster
Connect Cables
1. Power Supply (2)
2. IPMI LAN Port
3. ETH0: Mgmt Port
4. ETH1: Config Port
Figure 8 Analyzer Models with Fiber Management Port – Back View
4
21 3
6IntroSpect Analyzer 1XXX Series | Quick Start Guide

Follow Wiring Diagram
The wiring diagram in Figure 9 applies to Analyzer Models AI-ANA-1050-AN, AI-ANA-1050-CN, AI-ANA-1550-AN,
AI-ANA-1550-CN.
Refer to Figure 8 for a detailed back view of the appliance as you connect the cables in the wiring diagram.
Figure 9 Wiring Diagram for Analyzer Models AI-ANA-1050-AN, AI-ANA-1050-CN, AI-ANA-1550-AN, AI-ANA-
1550-CN with Fiber Management Port
Compute Node N
Compute Node 2
Compute Node 1
AN Node
ETH1 ETH0
ETH1 ETH0
ETH1 ETH0
ETH1 ETH0
Customer-supplied 10G Fiber Switch
To
Corporate
Network
Configure the Analyzer Cluster
1. Connect a laptop to a free port on the 10G fiber switch.
2. Open a browser instance and connect to: https://192.168.1.254:8443.
3. Complete the IntroSpect setup wizard.
For detailed setup instructions, see the IntroSpect Appliance Setup Guides.
IntroSpect Analyzer 1XXX Series | Quick Start Guide 7

Copyright Information
© Copyright 2018 Hewlett Packard Enterprise Development LP.
Open Source Code
This product includes code licensed under the GNU General Public License, the GNU Lesser General Public
License, and/or certain other open source licenses. A complete machine-readable copy of the source code
corresponding to such code is available upon request. This offer is valid to anyone in receipt of this information
and shall expire three years following the date of the final distribution of this product version by Hewlett
Packard Enterprise Company. To obtain such source code, send a check or money order in the amount of US
$10.00 to:
Hewlett Packard Enterprise Company
Attn: General Counsel
3000 Hanover Street
Palo Alto, CA 94304
USA
Contacting Support
Main Site www.arubanetworks.com
Support hpe-aruba-introspect-support@hpe.com
Airheads Social Forums and Knowledge
Base
community.arubanetworks.com
North American Telephone 1-800-943-4526 (Toll Free)
1-408-754-1200
International Telephone arubanetworks.com/support-services/contact-support/
Software Licensing Site hpe.com/networking/support
End-of-life Information arubanetworks.com/support-services/end-of-life/
Security Incident Response Team Site: arubanetworks.com/support-services/security-bulletins/
Email: sirt@arubanetworks.com
Table 4: Contact Information
Revision History
The following table provides the revision history of this document.
Revision Change Description
Revision 3 Updated Table 1: Related Documents.
Revision 2 Added Preface and Revision History.
Revision 1 Initial release.
Table 5: Revision History
IntroSpect Analyzer 1XXX Series | Quick Start Guide 8
This manual suits for next models
8
Table of contents
Popular Measuring Instrument manuals by other brands

LogiCO2
LogiCO2 MkVII user manual

Kyoritsu Electrical Instruments Works, Ltd.
Kyoritsu Electrical Instruments Works, Ltd. KEW SNAP Series instruction manual

Centech
Centech 93297 Assembly & operating instructions

B+K precision
B+K precision 2650 instruction manual

S.E. International
S.E. International RADIATION ALERT Sentry manual

KICK ASS
KICK ASS KABTRYSHUNT user manual