Aseko welldana 12086 User manual

HYDROSTATIC
LEVEL METER
EN
USER MANUAL
www.asekopool.com
For ASIN AQUA: Home, Salt, Oxygen, Pro and ASIN POOL
EN
2
Hydrostatic Level meter
The compact hydrostatic level meter contains a silicon tensometric sensor
and evaluation electronics in durable teflon housing. From the teflon housing
comes the original cable which contains the original connecting cables and
an atmospheric pressure sampling tube. At the end of the original cable is the
terminal box. The front side of the teflon housing is equipped with a removable
cover, preventing mechanical damage to the membrane.
The level meter monitors the water level based on hydrostatic pressure
measurements.
The length of the original cable is 4 meters.
Its measuring range is by default set to 0 - 200 cm.
The level meter is compatible with the ASIN AQUA series:
Home, Oxygen, Salt, Profi, and lan controller ASIN Pool.
Installation
Installation is done by securing the teflon probe of the level meter in
a vertical position in a:
buffer tank
or in a
blind nozzle (skimmer pools)
Use a non-hermetic junction box to connect the wiring. The original cable
includes an atmospheric pressure sampling tube.
The atmospheric pressure sampling tube must be passable at all times.
Never remove the terminal box.
When winding the excess cable, the diameter of the circle must be at
least 30cm!
Do not shorten the original cable or mechanically modify it in any way.
In the buffer tank where the water swirls due to a strong inflow, the level meter
teflon probe must be placed in a stilling pipe, or at least as far as possible from
the source of the swirl.
For correct connection with the ASIN AQUA and ASIN POOL follow the instruc-
tions in the manual of the device.
Hydrostatic Level meter #12086
1
2
EN 3
CHLORINE pH ALGICID FLOCC
Waterlevel
150
mg/l
0.5
Chlorine
7. 2
pH –
pH
Flocculant
10
Algicid
10
Temperature
cmml/m3hourml/m3day °C
30.0
29.0
air
water
ON
FILTRATION
0.5 7.2
ON
ON
TIMER
CHLORINE pH ALGICID FLOCC
Waterlevel
150
mg/l
0.5
Chlorine
7. 2
pH –
pH
Flocculant
10
Algicid
10
Temperature
cmml/m3hourml/m3day °C
30.0
29.0
air
water
ON
FILTRATION
0.5 7.2
ON
ON
TIMER
Place the terminal box
and the original cable
accessible for possible
disassembly.
The atmospheric pres-
sure sampling tube.
Extension connecting cable
(2x wire) maximum 50 m.
Always use the extension con-
necting cable for connection
to the ASINAQUA .
Never remove the terminal
box.
DO NOT SHORTEN
THEORIGINAL CABEL!
Do not place the level sensor on
the bottom of buffer tank.
Secure the level sensor in a vertical
position.
Installation in buffer tank
1
Wind the excess original
cable, the diameter of
the circle must be at
least 30 cm.
Ø min.
30 cm
+1 cm
OK
-1 cm
Installation into the blind nozzle
of the skimmer pool
2
EN
4
Actual
water level
Level
0 cm
Protection, safety and compatibility
The level meter is equipped with protection against reverse polarity of the sup-
ply voltage and against current overload.
Protection against dangerous contact is ensured by a small safe voltage ac-
cording to ČSN 33 2000-4-41
Electromagnetic compatibility is ensured according to the standards ČSN EN
55011/B, ČSN EN 61326-1, ČSN EN 61000-4-2 (8 kV), -4-3 (10 V/m), -4-4 (2 kV)
a -4-6 (10 V).
The function of the level meter
in the ASIN Aqua and the ASIN Pool
The water level is monitored in four levels. Levels are entered in centimeters in
the configuration of ASIN Aqua.
Levels:
High level ALARM too much water in a buer tank
After this level is reached, the following actions may start:
• If the automatic filter backwash is enabled, one filter backwash cycle starts
and drains the wastewater.
• If the automatic filter backwash is not enabled, relay 19 switches
on (filter backwash) for the period until the level is OK. The second
circulating pump can be connected to this relay.
• If the circulation pump is turned OFF it will be turned ON.
Refilling - OFF required level reached
Refilling stops.
Refilling - ON level at which refilling starts
Refilling starts if the water level stays for 10 seconds below this value (to prevent
oscillating).
Low level  ALARM
The circulation pump and the controlling system will be turned o.

Popular Measuring Instrument manuals by other brands

Gigahertz Solutions HF38B manual

Gigahertz Solutions

Gigahertz Solutions HF38B manual

Diehl Metering HYDRUS 171A Installation and user guide

Diehl Metering

Diehl Metering HYDRUS 171A Installation and user guide

PCE Instruments PCE-T 260 Operation manual

PCE Instruments

PCE Instruments PCE-T 260 Operation manual

LaserLiner 033.55A manual

LaserLiner

LaserLiner 033.55A manual

wtw TetraCon 325 operating manual

wtw

wtw TetraCon 325 operating manual

REED C-322 instruction manual

REED

REED C-322 instruction manual

RST Instruments MEMS Digital Inclinometer System instruction manual

RST Instruments

RST Instruments MEMS Digital Inclinometer System instruction manual

Joy-it JT-DMSO2D72 manual

Joy-it

Joy-it JT-DMSO2D72 manual

General EMHT40 user manual

General

General EMHT40 user manual

Sokkia iM-100 Series Quick manual

Sokkia

Sokkia iM-100 Series Quick manual

Hilti PD 30 operating instructions

Hilti

Hilti PD 30 operating instructions

FLIR CM55 Getting started

FLIR

FLIR CM55 Getting started

TST tm-507rv user manual

TST

TST tm-507rv user manual

Lancol CTE-4000 instruction manual

Lancol

Lancol CTE-4000 instruction manual

Dakota Digital MLX-9X04 Series manual

Dakota Digital

Dakota Digital MLX-9X04 Series manual

Fluidwell F118-P manual

Fluidwell

Fluidwell F118-P manual

Lanberg 4-CHANNEL ICS-0404-0020 user manual

Lanberg

Lanberg 4-CHANNEL ICS-0404-0020 user manual

Boso Bosch+Sohn classic merkur RS User instructions

Boso Bosch+Sohn

Boso Bosch+Sohn classic merkur RS User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.