pg 6 of 12 ‡ SIGNET 5500 Flow Monitor
Menu Settings A - N:
(Factory default displays shown in menu column 1)
A. Sets flow units label (gpm) and timebase (gpm).
Flow units label: Aa - Zz, 0 - 9, /
Timebase options: h=hours, m=minutes, s=seconds,
d=days (timebase entry affects flow rate display and
4 to 20 mA output)
B. Sets Min→Max meter and dial range, 00.000 to
99999. (does not affect 4 to 20 mA output)
C. Sets flow K-Factor: 0.0001 to 99999. (see technical
notes below)
D. Sets 8-digit totalizer units label: Aa - Zz, 0 - 9, /
(does not affect totalizer display or outputs)
E. Sets totalizer K-Factor: 0.0001 to 99999. (see
techical notes below)
Menu items F - I repeat for relay 2 setup.
F. Sets relay operation mode Low or High, and flow rate
setpoint, 0.0000 - 99999. (sec. 8.5)
G. Sets relay hysteresis, 0.0000 - 99999. (sec. 8.5)
(Set to zero to disable hysteresis feature)
H. Sets relay pulse volume setpoint, 0.0001 - 99999.
(sec. 8.5). Set to 1.0000 to enable totalizer
function (sec. 8.5).
I. Sets relay pulse width, 0.10 - 999. seconds
(sec. 8.5)
J. Sets auxiliary output mode Low or High, and flow rate
setpoint, 0.0000 - 99999. (sec. 8.2).
K. Sets auxiliary output hysteresis, 0.0000 - 99999.
(Set to zero to disable hysteresis feature)
L. Sets auxiliary output pulse volume setpoint,
0.0001 - 99999. (sec. 8.2). Set to 1.0000 (factory
default) to enable totalizer function (sec. 8.2).
M. Sets auxiliary output pulse width, 0.10 - 999. seconds
N. Sets user defined setup date for maintenance records.
This feature is not an internal timer or calender
Technical Notes:
The flow and total K-Factors are independent of each other.
The K-Factor settings represent the number of pulses
generated by the +GF+SIGNET flow sensor for each
engineering unit of fluid measured (published in flow sensor
manual).
K-Factor
Flow K-Factor
Last calibration
quick
press
To return to
VIEW menu:
quick
press
To restore original value:
Flow units Unit + timebase: h,m,s,d
Flow range
Setup date
Meter Min→Max
- Display label only -
K-Factor
Total units
Total K-Factor
Mode & setpoint
Press keys in sequence
will appear during code entry.
to enter menu,
Mode & setpoint
Relay
Mode & setpoint
Aux output
Mode & setpoint
Aux output
Pulse width
Aux output
Hysteresis
Aux output
Relay
Hysteresis setting
Relay ENTER
Relay Low or High Mode Selected
Aux Output Low or High Mode Selected
Aux Output Pulse mode selected, step J
Relay Pulse Mode Selected, step F
A.
B.
C.
D.
E.
F.
G.
H.
Pulse width
Relay
I.
J.
K.
L.
M.
N.
"SAVING"
briefly
displays
123
Choose: Change: Save:
N↓
A↑
9.2 CALIBRATE Menu