USER MANUAL
Keys:
> 1 – Audible Beep ON/OFF Switch.
> 2 – Audible Beep Interval set up button
> 3 – Reset Button (RAZ).
> 4 – Average Speed Update Button (MAJ).
> 5 – Rotary Switches
How to Use LA SOLUTION ?
1. Please note that LA SOLUTION must be
connected to your VHTRIP, VHTRIP TWIN or
MINITrip to work.
Note : The display will start counting using the
average input set up when LA SOLUTION was switch
on.
2. Program target Average speed with the rotary
switches (5)
(Example: 59.99 Km/h = 5999) ;
3. Press MAJ (4) button. Unit will beep once to confirm
entry of the new average.
4. On the Stage start line, keep the RAZ button (3)
pressed during the countdown. Release it as the
car is given the “go”. Display will then start
counting.
Why the BIP (2) button?
This button allows you to chose when LA
SOLUTION will give you an audible beep.
For example:
If you want to drive with an advance of 50m on
the average, press the BIP button when the
display reads 0.05 KM. This value will not be
saved in the memory when the unit is switched
off. The unit is set up at default value 0.00
How to respect the target average speed?
You are on target average speed when LA SOLUTION
displays 0.00 km.
> If the value displayed is lower than 0: SPEED UP
> If the value displayed is higher than 0: SLOW
DOWN.
Nota : The average will be only accurate if your
tripmeter is correctly calibrated and if you
respect the itinerary…
How to change the average in the middle of a stage?
1. Before arriving to an average speed change, input the
new target average speed with the rotary switches (5)
but DO NOT PRESS the Average Speed Update
Button MAJ (4) (LA SOLUTION will keep on using the
previous average speed).
2. At the exact point in the stage where the average
speed change is taking place, press the Average
Speed Update Button MAJ (4). LA SOLUTION will
then start using the new average speed programmed.
.
(subject to modifications)
- Manufacturer’s Warranty :
o12 months. Manufacturer Return To Base.
- Dimensions:
Black ABS housing
oHeight: 57 mm
oWidth: 80 mm
oDepth: 25 mm
- Power Supply: Taken from the VH TRIP
- Units: Kms or Miles.
- Display:
o4 digits high density LCD
- Range:
oAverage: 0.01 to 99.99
oDistance: Unlimited;
oDisplay: – 9.99 to 99.99.
- Use:
oNo Calibration required.
oAverage programming by simple rotary switches.
oAudible Beep ON/OFF Switch.
oAverage Speed Update Button
oDistance reset button
oAudible Beep interval set up button
- Connection:
Lead connection to the Tripmeter.