Ateco AT-301 User manual

AT - 301
Manual
Before attempting to connect or operate this product, please read these instructions completely!
Version:1.00

Contents
1. ATECO AT-30 1 General Introduction..........................................................................................1
1.1 Functional Components........................................................................................................ 1
1.11 AT-3 01sensor............................................................................................................... 1
1.12 Control Box.................................................................................................................2
1.2 Technical Specifications........................................................................................................3
1.3 Sharing the Sensor Between Rooms..................................................................................... 3
1.4 Using the different Positioning Systems..............................................................................3
2. Imaging Software General Introduction........................................................................................ .4
2.1 Computer System Requirements...........................................................................................4
2.2 Imaging Software................................................................................................................. .4
3. Driver Installation.......................................................................................................................... .5
4. Software Installation...................................................................................................................... .7
5. Register Key.................................................................................................................................. 11
6. Install Calibration File...................................................................................................................12
6.1 Install to Atecotech.........................................................................................................12
7. Software Operation......................................................................................................................13
8. Acquiring an Image....................................................................................................................... 20
8.1 Preparing the AT-30 1sensor................................................................................................ 20
8.2 Preparing for Acquisition.................................................................................................... 20
8.3 Launching the X-Ray.......................................................................................................... 21
9.Ateco Image..................................................................................................................................22
10. Troubleshooting Images.............................................................................................................. 33
11 Maintenance................................................................................................................................. 36
11.1 Visual Inspection............................................................................................................... 36
11.2 Periodic Maintenance........................................................................................................36
11.3 Cable Care........................................................................................................................36
11.4 Damaged or Non-Functioning Sensor..............................................................................36
12. Warranty...................................................................................................................................... 37
13. Notice.......................................................................................................................................... 37
13.1 Indication of Use............................................................................................................... 37
13.2 Brief Introduction of this Manual..................................................................................... 37
13.3 Manufacturer..................................................................................................................... 37
13.4 Packinglist......................................................................................................................... 37
13.5 Symbols............................................................................................................................. 38
14. Safety issue..................................................................................................................................39
14.1 Check Sensor and controller before using them............................................................... 39
14.2 Protect Sensor from Potential ESD Damage.................................................................... 39
14.3 Do Not Touch Exposed Connectors on Non-Medical Equipment and the Patient at the
Same Time.................................................................................................................................39
14.4 Ensure Proper System and PC Workstation Installation and Operation...........................39
14.5 Safety Classifications........................................................................................................40
14.6 Conditions required in operation, transportation, and storage......................................... 40

14.6.1 Operating conditions..............................................................................................40
14.6.2 Transport and Storage conditions.......................................................................... 40
15.Waste Electrical and Electronic Equipment................................................................................41
15.1 Background....................................................................................................................... 41
15.2 WEEE Marking................................................................................................................. 41
15.3 Reporting...........................................................................................................................41
15.4 WEEE from Users other than Private Households........................................................... 42
15.5 Information for Reuse Centers, Treatment and Recycling Facilities............................... 42
15.6 Warning and Safety Instructions....................................................................................... 42
15.7 Hygiene and Disinfection Instruction............................................................................... 43

1
1. ATECO AT-301 General Introduction
Dental digital x-ray imaging system is consisted of sensor, image controller, image
capture system and connection cable (USB port) , connected with PC or notebook via
USB cable. The power of controller and sensor is supplied by USB port, require no
battery or power charge system. The whole equipment need to work together with
imaging software.
1.1 Functional Components
1.11 AT-301 sensor
The sensor and control box is connected already, please check the light on control box,
before taking x-ray image. The power indicator on the control box displays yellow
light and working indicator flash green light.

2
The sensor active surface is flat including the size 1 and size 2.
Size1, universal sensor---Use for regular procedures, both for children and adult .
Size2 sensor---Use for bitewings procedures.
The sensor non-reactive to X-Rays surface, contains the cable attachment.
Figure 2 AT-301Sensor
1 Sensor non-reactive to X-Rays surface
2 Sensor active surface
1.12 Control Box
The sensor control box contains all the electronics of the sensor. The two LED light
shows whether the sensor is workable.
Figure 3
1.2 Technical Specifications
Sensor: APS CMOS sensor
External dimension (mm) :44×32() ; 40×26(AT-301)
Sensor Active Area : 36×27() ; 30×22.5(AT-301)
Sensor Thickness : 6mm
Dynamic Range : 0~4,096
Power : 5V±0.5V
Image Transfer :USB2.0
Cable Length :.≥3m
1.3 Sharing the Sensor Between Rooms
You can share the sensor between several rooms to provide access for several dentist

3
based on ATECO Server software. The computer must have the ATECO Dentist
dental imaging software, and ATECO Server must installed in one computer.
To share the sensor between several computers, move it from room to room. When
you connect the sensor to aUSB 2.0 port on the computer, the sensor is recognized
automatically and is operational.
To share data between rooms, you can connect them to remote data---ATECO Server
database. The ATECO Dentist dental imaging software needs only to access a shared
database on the same computer or on a remote computer, which means ATECO Server
database.
1.4 Using the different Positioning Systems
There are two ways to position the sensor in the patient mouth to get an classic
radiology. You may spend some time to adapt due to the rigidity of the sensor.
One method is angular bisector technique, the other method is paralleling technique. It
is just the way to position sensor, which can be chosen by practitioner’s experience.
X-Ray Generator Compatibility
Normally, the sensor is compatible with all generators which meets the present
standard of intraoral radiology. You can use a high frequency or conventional
generator. To achieve gaining better images, the generator must operate with a voltage
of 65 to 70kV.
1.5 Attentions
1As a precision devices, avoid flop,pulling and long-time disinfectant soak
2.Put disposable plastic jackets before used, avoid cross infection and allergy
3.No bite, for fear that the sensor or the jacket been broken
4.Caution for epileptic or psychopath
5.Learn the user manual carefully before use
6.User should be the professional dental or technician

4
2. Imaging Software General Introduction
2.1 Computer System Requirements
Processor: Intel 1.2GHz chip or above;
Memory: Above 1G ;
Hard disk: Above 40G;
Interface: USB 2.0;
Display: Resolution 1024 × 758 (15") or above
Operating System: Windows XP
The computer connected to system shall be in accordance with IEC 60950-1:6005.
2.2 Imaging Software
The Ateco AT-301 dental imaging system operates with the following software:
Atecotech
Atecotech Server for sharing information between workstations.
Atecotech Software is a user-friendly working interface that was designed and
developed specifically for radiological diagnosis. It is the common imaging platform
for all our digital systems for dentistry.

5
3. Driver Installation
1. Insert the CD into CD-ROM or DVD drive ,browse CD then double click on the
icon to continue. It will show
2. Click ,it will show
3. Click ,it will show

6
4. lick ,it will show
5. Cl

7
ick ,the driver is installed.
Then connect the sensor to computer via USB cable, the computer will recognize it, and will show
it is ready to use.
4. Software Installation
Double-click on the My Computer icon on your desktop, then open the CD-ROM
drive by double clicking.
1. Click the button on the interface of the CD or double-click the icon in
the CD, and then it shows:

8
2. Choose the required language.
3. Click on the button ,
4. The default destination folder is “D: /Atecotech”. If you want to change the route,
please click on the button of to select the folder you want.
Then click on , and then it shows

9
5. Click on , then it shows. There are two selections for creating the icon,
please make the selection according to your needs click , then it shows:
6. Click on the button , then it shows:

10
7. Click on the following window will be shown:
8. When the installation is finished, the following window will be show:

11
9. Then click on the button , the whole installation was completed and the
software will be launched automatically, and there will be a shortcut on the
desktop.
5. Install Calibration File
Install To Atecotech
Provided with every sensor is a disk containing the sensor calibration file. Each
calibration file is unique to the sensor it was shipped with and the file must be
installed on every computer systems before using that sensor. Every calibration file is
consisted of 3 files , copy these 3 files from the CD and then paste into software
installed destination folder , the default destination folder is
D
:\Atecotech\Sensor
.And then the calibration files installation is finished .
Copy the 3 files under “Calibration file”in CD and paste them into the correct
installation path file folder, then it’s finished.

12
6. Register Key
30 days later since the date of software installation, the software will ask for register.
Double click on the target frame, register key windows will come.
Please remember to register the software within 30 days of installation.
Click on Help in menu bar then select Register .
Input the information in the frame, and then click on Send Registration button, in
normal situation, there will be a auto-run email jumping out.
If your computer have no email support server, you may meet the following notice.
Please click on OK and then click on the button of Export Req file .

13
7. Software Operation
User interface
Double click on the icon to launch the software, the Atecotech window will
be shown:
Example Screen:
1.System menu of the program windows
2.Menu bar
3.Tool bar
4.Patient account list
5.Teeth chart
6.Target frame
7. Image information
Menu Bar
Each item contains a drop-down menu, and some of function can be achieved directly
from the icon in toolbar
Change language
Click on Tools(T) on the menu bar and select Option.

14
Click on Display, then select the your target language.
In Recent history part, there are two options, it arranges the order of First name and
Last, this depends on countries custom .
Please click on OK, it will show
Click OK, the software will be restarted automatically and switch to be the language
you selected.

15
Toolbar
Each button contains a icon and will show a short message to explain corresponding
function by moving the mouse pointer to the icon.
Establish Patient account
1. Click the icon in the toolbar or select new patient in file of menu bar
Then it will show
Input patient information ,select picture series and you can also input study comments
in the frame and then click on OK . The new patient account has been created .

16
Target frame (18 pcs)
If the first one is full (Maximum 20 images for each account )
Click on for creating another account under the same patient.
For establishing a account for another patient , please select “ new patient ” in this
windows
A new patient case has been created successfully.
Table of contents
Popular Dental Equipment manuals by other brands

AMD Lasers
AMD Lasers PICASSO Operating instructions manual

DCI Edge
DCI Edge SERIES 5 Instructions for use

iM3
iM3 Endo-A-class Vet LED Instructions for use

Straumann
Straumann SC CARES Instructions for use

DentalEZ
DentalEZ Star TITAN 3 5K MOTOR instruction manual

Durr Dental
Durr Dental Primo Installation and operating instructions