Atlasen LEO v2 User manual

© 2022 atlasen | All rights reserved | www.atlasen.com
LEO v2
Wall-Mounted Type
Installation Guide

© 2022 atlasen | All rights reserved | www.atlasen.com 2
1. Product Components ---------------------------------------------------------------- 3
2. Dimension ---------------------------------------------------------------------------- 4
3. Management target ------------------------------------------------------------------ 5
4. How to install ------------------------------------------------------------------------ 6
5. Product specification ---------------------------------------------------------------- 7
6. Cautions ----------------------------------------------------------------------------------- 8
7. Safety Precautions --------------------------------------------------------------------------- 9
8. Warranty ----------------------------------------------------------------------------------- 10
Table of Contents

© 2022 atlasen | All rights reserved | www.atlasen.com
Part 1. Sensor Device
Part 2. AC/DC Converter
FRONT BACK
FRONT BACK
1. Product Components
3

© 2022 atlasen | All rights reserved | www.atlasen.com 4
2. Dimension

© 2022 atlasen | All rights reserved | www.atlasen.com 5
3. Management target
Category Indicies
Thermal 1 Temperature
2 Relative Humidity
Air
3 Carbon Dioxide (CO2)
4 Carbon monoxide (CO)
5 Total Volatile Organic Compounds (TVOC)
6 Particulate Matters (PM10)
7 Particulate Matters (PM2.5)
8 Particulate Matters (PM1.0)
9 Formaldehyde (HCHO)
10 Ozone (O3)
11 Nitrogen Dioxide (NO2)
12 Ammonia (NH3)
13 Hydrogen Sulfide (H2S)
14 Sulfur Dioxide (SO2)
15 Methane (CH4)
Lighting 16 Illuminance (Lux)
Acousitic 17 Sound level (dBA)

© 2022 atlasen | All rights reserved | www.atlasen.com
Install the junction box on the wall
1
WALL
Wall Wire
2
WALL
AC
Connect the wall wires to the WAGO
of the Part 2( AC/DC converter)
1. Push up the Orange valve
2. Put the wires all the way in
3. Push down the Orange valve
WAGO
Put the Part 2 into the junction box and
combine
3
WALL
Wall Wire
Connect the wire of the Part 1(Sensor
Device) to Part 2.
4
WALL
Wall Wire
5
Wall Wire
Fix the Part 1 by fitting it to the clasp
6
4. How to Install

© 2022 atlasen | All rights reserved | www.atlasen.com 7
Index Remark
Model No. LEO v2
Sensor Capacity Real-time IEQ Monitoring Device
Dimension Sensor Device: 94*94*25 (mm)
AC/DC Converter: 94*94*25 (mm)
Weight Sensor Device: 130g
AC/DC Converter: 100g
Operation Conditions Temperature: 0 to 50 °C, Humidity: 0 to 95 %
Storage Conditions Temperature: -20 to 70 °C, Humidity: 0 to 95 %
Warm Up Time @ Switch On < 20 sec
Power Supply Input: 100-240Vac, 50-60Hz, 1A
Output: 9Vdc/1A, USB Type C
Overvoltage category II
Pollution degree 2
IoT Connectivity
Wi-Fi: Wi-Fi 802.11 b/g/n (2.4 GHz)
Security: WPA/WPA2/WEP/TKIP/AES
LoRaWAN, BehrTech MYTHINGS, BACNet
RS485/RS422
Analyzing Tool RESTful, SOAP, SQL, Server Support
Interval Configurable, Default: 15 min.
System Requirement Android 4.1 or later, iOS 8 or later
atlasencontrol account
Certification FCC, KC, UL, ULC
Operating Life (Estimated) 5 years
5. Products Specification

© 2022 atlasen | All rights reserved | www.atlasen.com 8
6. Cautions
1. This product is for indoor use and is not waterproof.
2. Sensor readings may vary depending on the environment of use, installation, location,
calibration execution, etc.
3. Install the product on a level surface. There is a possibility of malfunction when it is
used tilted.
4. Internal sensors are sensitive to vibration and shaking, so please install in areas where
there is no vibration.
5.Please be careful not to be covered with dust in the vent hole of the sensor case for
accurate data measurement.
6.If the outside is contaminated by dust, please remove it with a dry towel.
7.If you open the sensor on your own, there is a risk of failure. Please make sure to
consult with the manufacturer.
8.If the LED on the rear panel is green, it is on normal operation;
if it is orange, it is malfunctioning.
If the orange light is shown, unplug the power and operate it again.
If the problem is not resolved, please contact customer service.
(Help Center: hello@atlasen.com)
9.In the case of malfunction or error, please contact customer service.

© 2022 atlasen | All rights reserved | www.atlasen.com 9
7. Safety Precautions
1. Avoid use in outdoor or condensed environments.
2. This equipment is permanently used equipment, and there is a risk of accidents if you
remove the product on your own after installation.
3. When disassembling for installation and repair, it must be performed by a manager
with professional knowledge.
4. Install only in spaces with UL certified Circuit-breaker. When installing or uninstalling,
you must power off with Circuit-breaker before working.
5. Circuit-breaker needs to be marked that circuit-breaker can disconnect power for this
product.
6. For DC supplied WIRE, it must be connected to a supply wire greater than 18 AWG.
7. The sensor automatically stops operating in the event of a short due to over-current.
Power off with Circuit-breaker and then perform uninstallation.
8.Do not disassemble or assemble the product while in use.
9.Please be aware of handling the product, as it may be damaged by falling or external
impact.
10.If the accessories (cables or power cables) are damaged or require replacement,
please contact us.
11.We are not responsible for any accidents or problems caused by failure to comply
with the safety precautions stated above.

© 2022 atlasen | All rights reserved | www.atlasen.com 10
8. Warranty
Product
Name
atlasen
IEQ IoT Sensor
Model
Name
atlasen
LEO
Serial
No.
Marked
on surface of the case
Date
of Purchase
MM
-DD-YYYY
Manufacturer
/Country
of Manufacture
atlasen,
Korea
Seller
Help
Center
hello@
atlasen.com
•The warranty period for this product is one year from the date of purchase. In the
case of a defect within the warranty period a free repair service will be provided.
•After the warranty period, service will be provided at a cost.
•However, in the case of service provided at a cost under Consumer Damage.
•Compensation Regulations(such as product damage due to user negligence), the
service is provided for a fee even during the warranty period.
•For shipping fees, for free of charge service, shipping fees will be charged for both
user and provider. For paid services, shipping will be charged on the user.
•This warranty will not be reissued.

© 2022 atlasen | All rights reserved | www.atlasen.com
Indoor Environmental Quality
CONTACT
Homepage
www.atlasen.com
E-Mail
Table of contents