Atos BullSequana Edge User manual

-1
Installation Guide
BullSequana Edge
86 A1 67FR 06 - March 2020

The following copyright notice protects this book under Copyright laws which prohibit such actions
as, but not limited to, copying, distributing, modifying, and making derivative works.
Copyright ©Bull SAS 2020
Printed in France
Trademarks and Acknowledgements
We acknowledge the right of proprietors of trademarks mentioned in this manual.
All brand names and software and hardware product names are subject to trademark and/or
patent protection.
Quoting of brand and product names is for information purposes only and does not represent
trademark and/or patent misuse.
Bull Cedoc
357 avenue Patton
BP 20845
49008 Angers Cedex 01
FRANCE
March 2020
Hardware
The information in this document is subject to change without notice. Bull will not be liable for errors contained
herein, or for incidental or consequential damages in connection with the use of this material.

Contents i
Table of Contents
Preface p‐1...............................................................................
Intended Readers p‐1.................................................................
Chapter 1. Checking the delivery contents 1-1.....................................
1.1. Unpacking the server 1-2..................................................
1.2. Checking labels 1-4.......................................................
1.2.1. Identification and safety labels 1-4................................
1.2.2. MAC address label 1-7.............................................
1.2.3. Fan hazard safety label 1-7........................................
Chapter 2. Installing the server 2-1.................................................
2.1. Installing the antennas 2-2................................................
2.2. Installing the server in a rack cabinet 2-3..................................
2.2.1. Installing the rails in the rack cabinet 2-3..........................
2.2.2. Installing the brackets on the server 2-7...........................
2.2.3. Installing the server 2-8...........................................
2.3. Installing the server on a flat surface 2-10...................................
2.4. Installing the server on a DIN rail 2-11......................................
2.5. Installing the server on a VESA holder 2-13..................................
Appendix A. Screws and washers A-1................................................


p‐1
Preface
Preface
This guide explains how to install the server.
See The Bull support web site for the most uptodate product information,
documentation, firmware updates, software fixes and service offers:
http://support.bull.com
Intended Readers
This guide is intended for use by qualified personnel in charge of installing the
server.
D049 DANGER
D049:
The product must not be used in life support system or other
applications where failure could threaten injury or life, and any such use
voids the limited warranty associated to the product.


Chapter 1. Checking the delivery contents 1-1
Chapter 1. Checking the delivery contents
Important ATTENTION: Please read carefully the safety instructions
before you perform the procedures described in this
manual.
ATTENTION : Merci de lire attentivement les consignes de
sécurité avant d'effectuer les procédures décrites dans ce
manuel.
ACHTUNG : Bitte lesen Sie sorgfältig die angegebenen
Sicherheitshinweise, bevor Sie die Verfahren in diesem
Handbuch beschrieben durchführen.
Multilingual Safety Notices Guide, 86 X1 12FL

1-2 Installation Guide
1.1. Unpacking the server
Important Before unpacking the device inspect the device packaging
for damage.
W020 WARNING
W020:
The server drawer must not be unpacked before it has reached the
room temperature (24 hours in the computer room).
According to the device configuration, the following items are included:
•BullSequana Edge server with its front bezel or aesthetic covers
•Antennas
•Rack mount kit and brackets
•DIN rail kit
•Adhesive bump
•Screws and washers
Server with a front bezel

Chapter 1. Checking the delivery contents 1-3
Server with aesthetic covers

1-4 Installation Guide
1.2. Checking labels
Safety warning label, including safety notices and graphic symbols, are present
on the server. Check that the electrical installation in place complies with the
label details.
1.2.1. Identification and safety labels
Localization
The labels are underneath the server.

Chapter 1. Checking the delivery contents 1-5
Identification and safety label
Mark Description
AProduct name: MIPSE
BModel number
CSerial Number
DElectrical characteristics
ERecycling Symbol: Indicates the mandatory obligation to
reuse and recycle electronic and electrical equipment
properly.
FCE certification
W071 WARNING
W071:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received including
interference that may cause undesired operation

1-6 Installation Guide
Marketing labels
For marketing purpose only, the product name is BullSequana Edge (G).
Hazard electrical symbol
This label indicates risk of electric shock.
C051 CAUTION
C051:
This unit has one internal power supply. Disconnect power supply cable
from the unit before servicing.

Chapter 1. Checking the delivery contents 1-7
1.2.2. MAC address label
Localization
The label is on the right-hand of the server.
MAC address label
1.2.3. Fan hazard safety label
Localization
The labels are on the fans, inside the server.
Fan hazard safety label


Chapter 2. Installing the server 2-1
Chapter 2. Installing the server
C050 CAUTION
C050:
The device must be installed in a location where the transmitting
antenna is at least 20 cm from any people in order to comply with radio
frequency exposure regulatory requirements.
W079 WARNING
W079:
Devices and antennas must not be operated with other antennas or
transmitters. Only devices and antennas, tested and approved by the
manufacturer, should be used. It is prohibited to change the
configuration of devices or antennas. Any changes will violate safety
rules.
W080 WARNING
W080:
Use only antennas which have been provided and approved by the
manufacturer. Non-approved antennas may produce excessive radio
frequency transmitting power and may exceed FCC/IC limits.
Non-approved antenna use is prohibited.

2-2 Installation Guide
2.1. Installing the antennas
Note The pictures in the following procedure show a server with a front bezel
but the same procedure applies to a server with aesthetic covers.
1. Locate the antenna position
Rear view
Mark Description
AExternal antenna 2 : (Dual-band WiFi or LoRaWAN or LTE
3G/4G GSM
BExternal antenna 1 : Dual-band WiFi or LoRaWAN or LTE 3G/4G
GSM
CExternal antenna 0 : BMC WiFi
2. Turn the antenna to fix it to the server
Rear view

Chapter 2. Installing the server 2-3
2.2. Installing the server in a rack cabinet
Note A server with aesthetic covers cannot be installed in a rack cabinet.
Required screws, nuts and washers
See Appendix A Screws and washers
Required tools
T25 Torx screwdriver
T20 Torx screwdriver
T10 Torx screwdriver
2.2.1. Installing the rails in the rack cabinet
1. Prepare the rails
1. Loosen the four screws of each rail.

2-4 Installation Guide
2. Adjust the length of each rail.
3. Tighten the four screws of each rail.

Chapter 2. Installing the server 2-5
2. From the front, install the left rail

2-6 Installation Guide
3. From the front, install the right rail
Other manuals for BullSequana Edge
2
Table of contents
Other Atos Server manuals
Popular Server manuals by other brands

Lenovo
Lenovo ThinkServer RD530 Informacije o jamstvu i podršci

HP
HP D7171A - NetServer - LPr datasheet

Lantronix
Lantronix C 7/01 user guide

HP
HP P4522A - Traffic Management Server Sa8220 user guide

Dell EMC
Dell EMC PowerEdge T440 Getting started guide

HP
HP D5970A - NetServer - LCII Service & reference guide