manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ATTO Technology
  6. •
  7. Adapter
  8. •
  9. ATTO Technology Celerity FC-22XH User manual

ATTO Technology Celerity FC-22XH User manual

This manual suits for next models

4

Other ATTO Technology Adapter manuals

ATTO Technology UL25 User manual

ATTO Technology

ATTO Technology UL25 User manual

ATTO Technology FastFrame Series User manual

ATTO Technology

ATTO Technology FastFrame Series User manual

ATTO Technology R30F User manual

ATTO Technology

ATTO Technology R30F User manual

ATTO Technology ATTO ExpressPCI FC 2600 User manual

ATTO Technology

ATTO Technology ATTO ExpressPCI FC 2600 User manual

ATTO Technology Express SAS R348 User manual

ATTO Technology

ATTO Technology Express SAS R348 User manual

ATTO Technology EPCI-UL4D User manual

ATTO Technology

ATTO Technology EPCI-UL4D User manual

ATTO Technology ThunderStream User manual

ATTO Technology

ATTO Technology ThunderStream User manual

ATTO Technology Celerity FC-24XL User manual

ATTO Technology

ATTO Technology Celerity FC-24XL User manual

ATTO Technology ThunderLink FC 3322 User manual

ATTO Technology

ATTO Technology ThunderLink FC 3322 User manual

ATTO Technology ATTO Celerity FC-81EN User manual

ATTO Technology

ATTO Technology ATTO Celerity FC-81EN User manual

ATTO Technology ExpressSAS User manual

ATTO Technology

ATTO Technology ExpressSAS User manual

ATTO Technology Celerity FC-21PS User manual

ATTO Technology

ATTO Technology Celerity FC-21PS User manual

ATTO Technology Celerity FC-164E User manual

ATTO Technology

ATTO Technology Celerity FC-164E User manual

ATTO Technology FC 3300 User manual

ATTO Technology

ATTO Technology FC 3300 User manual

ATTO Technology ATTO Celerity FC-41XS User manual

ATTO Technology

ATTO Technology ATTO Celerity FC-41XS User manual

Popular Adapter manuals by other brands

Mini Gadgets BB2Outlet user manual

Mini Gadgets

Mini Gadgets BB2Outlet user manual

LSI LSISAS3442E-R Quick installation guide

LSI

LSI LSISAS3442E-R Quick installation guide

Moeller BBA -16 Series installation instructions

Moeller

Moeller BBA -16 Series installation instructions

Acer MWA3 quick start guide

Acer

Acer MWA3 quick start guide

Connect Tech ADG095 user guide

Connect Tech

Connect Tech ADG095 user guide

cable matters 604002 user manual

cable matters

cable matters 604002 user manual

Solwise PL-85PEW Easy start

Solwise

Solwise PL-85PEW Easy start

HP Photosmart 7100 user guide

HP

HP Photosmart 7100 user guide

HP E2494A installation guide

HP

HP E2494A installation guide

StarTech.com USB150WN1X1 quick start guide

StarTech.com

StarTech.com USB150WN1X1 quick start guide

Lindy 43198 user manual

Lindy

Lindy 43198 user manual

A&D AD-8527 instruction manual

A&D

A&D AD-8527 instruction manual

Motorola WU830G user guide

Motorola

Motorola WU830G user guide

Hawking HUF2 Specifications

Hawking

Hawking HUF2 Specifications

Allen-Bradley E3 Plus installation instructions

Allen-Bradley

Allen-Bradley E3 Plus installation instructions

Trust BT-2210Tp manual

Trust

Trust BT-2210Tp manual

HP NC7170 overview

HP

HP NC7170 overview

Uconnect BLE-485C user manual

Uconnect

Uconnect BLE-485C user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

155 CrossPoint Parkway • Amherst, NY 14068 • 716.691.1999
attotech.com
Storage Adapter
Dual-channel 2-Gigabit Fibre Channel Storage Adapter with
Four External Hub Ports Featuring ADS™ Technology
ATTO Celerity FC-22XH Storage Adapter
• Dual-channel 2.125-Gigabit Fibre
Channel storage adapter
• 400 MB/sec. throughput per channel
in full-duplex mode
• Onboard hub provides connectivity,
design flexibility and scalability
• Unique four-port, dual-channel design
maximizes value of expansion slots
• Exclusive Advanced Data Streaming
(ADS™) Technology
• Proven industry interoperability
with support for SNIA HBA API
• Driver support for Linux, Windows®
and Mac® OS X
• On-demand, automatic negotiation
between 2-Gig and 1-Gig
Fibre Channel
• 2-year standard product warranty
TECHNICAL
HIGHLIGHTS
ATTO Celerity storage adapters are an integrated
family of advanced storage connectivity
solutions. The Celerity FC-22XH uses embedded
hub technology that provides four external
connections from two independent FC ports.
It simplifies SAN fabric design and provides
more capabilities than other dual-channel
adapters.
The Celerity FC-22XH provides high performance
and reliability through award-winning hardware
design. When using the FC-22XH in SAN
configurations, precise signal quality and low
emissions improve the data link and reduce
overall consumption of fabric bandwidth.
Additionally, the FC-22XH automatically
bypasses unused / malfunctioning ports,
increasing fabric integrity.
Unique FC-22XH hardware features extend the
capabilities of other SAN software and hardware,
relieving them from their data management
burdens. The onboard hub provides four external
connections. This allows the adapter to be used
as a standard dual channel product, or users
can take advantage of the extra ports to increase
the number of available connections per expansion
slot. This decreases the cost of connectivity.
This exclusive design eliminates the need for
fabric hubs, simplifies the fabric design and
reduces hardware costs.
The FC-22XH is part of ATTO’s Celerity family of
storage connectivity products. These products
are designed to provide reliable connectivity,
intelligence and scalability. Meeting tomorrow’s
connectivity needs today, Celerity FC adapters
extend the capabilities of software and hardware,
relieving them from their data-management
burdens.
Increase overall system performance and drive
intelligence all the way to the edge of
the SAN. Celerity, a platform for
advanced storage
connectivity.
Storage Adapter
Hardware Specifications
©2005 ATTO Technology, Inc. Specifications subject to change without notice.
attotech.com
Fibre Channel Interface
• Four external ports connect to two
independent FC ports
• 2.125-Gigabit data-transfer rates per chan-
nel
• 400 MB/sec. maximum full-duplex
throughput per channel
• Supports all FC topologies: direct fabric,
arbitrated loop and point-to-point
• ANSI Fibre Channel: FC-PH, FC-FCP, FC
FCP2, FC-AL, FC-AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer Credits: 8 @ 512 bytes; 8 @ 2k bytes
Advanced FC Capabilities:
• Supports SNIA HBA API
• Supports Target and Initiator modes
• LUN masking
• Interupt coalescing
PCI Bus Specifications:
• 64-bit, 133 MHz PCI-X (backward compatible
to 32-bit and 33MHz)
• PCI-X 1.0a compliant
• PCI 2.2 compliant
• 3.3V PCI signaling only
External Connectivity:
• Easy-to-install full height connection bracket
• Up to four Short Wave optical LC SFP
pluggable transceivers
• External LEDs for on-line and speed status
for each channel
• Two (2) transceivers included
Software Specifications:
Driver Support:
• Windows Server 2003
• Windows XP
• Windows 2000
• Linux (Red Hat, SUSE)
• Mac OS X (10.4.x Tiger)
• Universal boot support
• Advanced Data Streaming (ADS™) Technology
Agency Approvals
• FCC Rules, part 15, Class B
• CE Mark: CISPR 22:2002/EN55022:2002,
Class B
Dimensions:
• Conforms to PCI standard height,
half length form factor specifications
• Length: 6.600”
• Height: 3.800”
Operating Environment:
• Temperature: 0-45ºC (32º-
113ºF)
• Humidity: 5 to 95% non-condensing
ATTO Celerity FC-22XH Storage Adapter
Storage Environment:
• Temperature: -40º to 70ºC (40º to 158º F)
• Humidity: 5 to 95% non-condensing
Power: 3.3V @ 2.0A max
Airflow: 100 lf/m (minimum)
recommended
Optical Cabling:
• 50/125µm up to 300m @ 2-Gb
• 50/125µm up to 500m @ 1-Gb
Environmental & Physical Specifications
Rev 9/05
Celerity FC Product Family
1 ATTO’s onboard hub technology allows for up to four external connections to two FC channels
2 Performance ceiling is constrained by 133 MHz PCI-X bus transfer speed
3 Backward compatible to 32-bit and 33 MHz PCI; FC-24XL and FC-22XH are 3.3V; FC-21PS is 3.3V/5V Universal
4 ATTO ExpressStripe for OS X available; other software RAID supported
FC-41XS FC-22XH FC-21PS
PRODUCT FEATURES
FC-24XL
FC-42XS
FC-44ES
Fibre Channel Ports 4 2 2 1 4 4/211
Fibre Channel Protocol 4-Gb 4-Gb 4-Gb 4-Gb 2-Gb 2-Gb 2-Gb
Maximum Transfer Rate 1.6 GB/sec. 800 MB/sec. 800 MB/sec. 400 MB/sec. 800 MB/sec. 400 MB/sec. 200 MB/sec.
(half duplex)
Maximum Transfer Rate 2 GB/sec. 1 GB/sec. 1 GB/sec.2 800 MB/sec. 1 GB/sec.2800 MB/sec. 400 MB/sec.
(full duplex)
Bus Type PCIe PCIe PCI-X PCI-X PCI-X PCI-X PCI
Bus Characteristics38 lane 8 lane 64-bit, 133 MHz 64-bit, 133 MHz 64-bit, 133 MHz 64-bit, 133 MHZ 64-bit, 66 MHz
Optical Interface SFP LC SFP LC SFP LC SFP LC SFP LC SFP LC SFF LC
Maximum Cable Length 300m @ 2-Gb 300m @ 2-Gb 300m @ 2-Gb 300m @ 2-Gb 500m @ 1-Gb 500m @ 1-Gb 500m @ 1-Gb
150m @ 4-Gb 150m @ 4-Gb 150m @ 4-Gb 150m @ 4-Gb 300m @ 2-Gb 300m @ 2-Gb 300m @ 2-Gb
Advanced Data Streaming • • • • • • •
(ADS™) Technology
Software RAID Support4• • • • • • •
Developer’s Kit • • • • • • •
(Target Mode & API)
Developer’s Kit (Advanced)
- - - - •- -
Integrated Offload & - - - - •- -
Processing Center (IOPC)
Onboard Memory for - - - - •- -
Direct Memory Transfers
Integrated Hub Technology
- - - - - •-
Windows Driver Support • • • • • • •
Linux (Red Hat, SUSE)
• • • • • • •
Driver Support
Mac OS X (Tiger)
- - • • • • •
Driver Support