AUDAC R2 User manual

R2
User Manual
www.audac.eu

2

3
Index
Introduction 5
Environment 7
Safety requirements 9
Caution servicing9
Chapter 1: Pin connections and connectors 11
Attention 11
Chapter 2: Overview front and rear panel 13
Front description 13
Rear description 14
Audio in- and outputs 14
Priority, S/PDIF & Fiber link inputs 14
Peripheral interfaces 15
Control ports 15
Chapter 3: Wire up the system 15
Chapter 4: R2 Quick start guide 16
Connecting the R2 16
Configuring the R2 17
Chapter 5: User interface & configuration 19
Open the user interface 19
Login screen 19
Main screen 20
Zone settings 21
Sound settings 22
Test signals 23
Configuration screen 24
Digital input setection 24
Timer settings 25
Time settings 26
Network settings 27
Paging settings 27
Priority settings 28
Wall panel settings 29
R2 Address settings 30
Fiber settings 31
Amplifier bridging 32
Password settings 32
Factory settings 33

4
Lite User Interface 34
Login screen 34
Main screen 34
iPhone + iPad 35
Chapter 6: Peripheral interfaces 36
Wall mounted control panels 37
DW3018/4018 Basic wall panel 37
DW5065 All-in-one wall panel 38
Connection possibilities 39
Chapter 7: Paging 41
Chapter 8: Cascading the R2 46
Principle 48
Fiber audio flow 48
Setting up the project 50
Connection possibilities 39
Chapter 9: Additional information 53
IP Basics 53
Updating the R2 54
Technical specifications 55
Personal notes 56

5
Introduction
Multi-Zone Audio Matrix System
TheR2isaMulti-Zoneaudiodistributionsystemwhichisatrulypolyvalentsolutionforcommercial
andresidentialapplications,withtheflexibilityofamultizonerouter.Itdeliversacomprehensiveand
expandablepowerfulsolutionfornearlyeverysituation.Withitslargenumberofextensionmodules
andconfigurationmodes,itprovidesasolutionforanuncountableamountofinstallations–largeor
small,simpleorcomplex.
Ingeneral,itisan8x8digitalaudiomatrixsystem,whichisbasedonapowerfulDSPprocessor.It
isfullydigitallycontrollable,andthebuilt-indigitalmatrixmakesitpossibletopatchanyoftheinput
signalstoanyoftheoutputsignals.
Itisstandardequippedwith8analoglineinputsand8analoglineoutputs,buttheflexiblestructureof
thedevicemakesiteasytoextendthisnumbertoanappropriatesolutionforeachspecificsituation.
Ifdesired,itiseasytocascademultipleR2’swiththefiberinterconnectionmodules.Thismakesit
possibletotransferupto8stereochannelsandtoextendtoannearlyunlimitednumberofzones.
Butitismuchmorethanthat,duetotheextremelypowerfulDSPprocessor,itprovidesgreater
flexibility,higherreliabilityandlowerlatencythananyotheramplifierofitskind.Moreover,it’scapable
ofdoingcomplexcalculationsonthedigitalaudiosignals,whichmakesitpossibletointegratedigital
filtersintothesystemandgeneratecomplexaudiosignals.
Inaddition,areal-timeclockisprovidedwhichmakesitpossibletocreatetimescheduleswithup
to256pre-programmedevents,singleandrecurring.
EveryR2isstandardequippedwithanintegratedEthernetcontrolinterfacewhichmakesitpossible
toconfigureandcontroltheR2fromanyPC,laptoporPDAwhichisconnectedtotheinternet.Just
useyourbrowser,gototheappropriatewebsiteandyouhavecompletecontroloftheR2.
Anoptionaltouchscreencanbeinstalledinthefrontoftheamplifierandthereareoptionalwall
controlpanelswherebythedesiredmusicsourceandvolumecanbeselectedforaspecificzone.
AnRS232interfaceisprovidedforconfigurationandcontrolwithperipheralsfromothermanufacturers
whichmakeuseofanRS232connection,likeAMX,Crestron,…thecontrolcommandsarefreely
availablewhichmakesiteasytodevelopspecificapplicationsthatworkincombinationwiththeR2.

6

7
Environment
Donotplacethisunitinanenclosedenvironmentsuchasabookshelforcloset.Ensurethere
isadequateventilationtocooltheunit.Donotblocktheventilationopenings.
Donotplacetheunitinenvironmentswhichcontainhighlevelsofdust,heat,moistureor
vibration.
Donotusetheunitnearwaterorotherliquids.Makesurenowaterorotherliquidscanbe
spilled,drippedorsplashedontheunit.
Theunitisdevelopedforindooruseonly.Donotuseitoutdoors.
Donotplaceobjects(books,vases,…)ontopoftheunit.
Placetheunitonastablebaseormountitinastablerack.

8

9
Chapter 1
Safety requirements
Alwayshandletheunitwithcare.
Onlyuseagroundedsocketoutletandapowercordwithgroundingplugtoplugintheunit.
Thisunitisnotatoy.Itshouldnotbeoperatedbychildren.
DonotstickobjectsthroughtheventilationopeningsoftheR2.
Donotopentheunit.(riskforelectricalshock)
TheR2containsseveral‘jumpers’whichcanbeset.Thesesettingsmayonlybedoneby
qualifiedpeople.
CAUTION - SERVICING
Thisunitcontainsnouserserviceableparts.Referallservicingto
qualifiedservicepersonnel.Donotperformanyservicingunless
youarequalifiedtodoso.
NOTE
This produc t conforms to the following European Standards:
EN50081-1:1992,EN50082-1:1992,EN60065:1994

10

11
Chapter 1
Pin connections and connectors
Cinch (RCA):
Forlineinputconnections
Tip= Signal Sleeve= Ground
White= Left Red= Right
RJ45 (RS485, Digital Audio, +24V DC):
ForconnectiontoWallPanels
Pin 1 White-Orange AUDIOTXA
Pin 2 Orange AUDIOTXB
Pin 3 White-Green +24VDC
Pin 4 Blue RS485A
Pin 5 White-Blue RS485B
Pin 6 Green GND
Pin 7 White-Brown AUDIORXA
Pin 8 Brown AUDIORXB
ATTENTION
Thetwistedpaircablingmustalwaysbe‘straight’.Incaseofself
madecabling,itmustbewiredasdescribedabove,tomakethe
systemworkproperly.
RS232 (serial connection interface):
Forconnectionwithhomeautomationsystems,orotherremotecontrolequipment
Connection StandardRS232
PIN 2 R2TX
PIN 3 R2RX
PIN 5 GND
Settings 19200Baud
8Bit
1Stopbit
Noparity
NoHandshaking
RS232 / RS485 / TCP/IP
TheR2amplifierhasRS232,RS485andTCP/IPportswhichallacceptthesamecommands.
ThecompletecommandsettocontroltheR2amplifierisavailableintheR2commands
usermanualwhichisfreelyavailableonwww.audac.eu/download.

12

13
Chapter 2
Overview front & rear panel
R2
OnthefrontoftheR2amplifierareapowerbutton,fourUSBconnectionportsspaceforanoptional
touchscreen(R2DIS)provided.
Thepowerbuttonisalatchingtypeandshouldbeusedforpowering-upthesystem.Whenthepowerbutton
ispressed,theR2willstartup.Whenthestartupprocedureistakingplace,theLEDonfrontoftheamplifier
willblinkblue.Afterthestartupprocedureiscompleted,theLEDwilllight-upblue,andtheR2willbeready
foroperation.
Therectangularareaonthefrontoftheamplifieristhelocationwheretheoptionaltouchscreenshouldbe
installed(R2DIS).ThistouchscreencanbeusedforcontrollingandconfiguringallthefunctionsoftheR2
amplifier.Thisunitconsistsofa7”touchscreenwithaformatof16/9andaresolutionof800x480px.A
smallintegratedcomputercontrolsthefunctionsofthetouchscreen.
ThelowerUSBconnectionportonfrontoftheamplifierisdedicatedforsoftwareupdates.Whenthe
touchscreenisinstalled,theotherthreeUSBconnectionscanbeusedtoconnectseveralperipheralstothe
amplifierlikeanUSBkeyboardormouse.
Whentheoptionaltouchscreenisnotinstalledandthelowerusbconnectionisconnectedtoyourpc,the
otherthreeUSBportsactasahubtoyourcomputer.TheperipheralsconnectedtotheUSBportswillbe
connectedtoyourPC.
Front

14
8linelevelin-andoutputsareprovidedinitsstandardconfiguration.Each
lineinputisfittedwithstereoRCAinputconnectorsandaclippingLEDwhich
illuminateswhenthesignalreachestheclippinglevel.Bymeansofthegaincontrol
potentiometers,theleveloftheinputsignalscanbecontrolled.
EachzoneoutputisfittedwithRCAstereoconnectorsfortheconnectionofexternal
amplifiers.Whentheoptionalpoweramplifierkitisinstalled(R2POW),eachoutput
zonehasanamplifiedstereowithapowerof2x40Watt@4Ohmor2x20
Watt@8Ohm.Theamplifiedzoneoutputscanbebridgedinthegraphicaluser
interfacetoobtainapowerof80Watt@8Ohmforeachoutputzone.
Audio in- and outputs
Priority, S/PDIF & Fiber
Twoaudiopriorityinputsandtwoprioritycontactinputsprovided.Dependingofthe
configuration,4prioritysignalscanbeused.Theactionsthatneedtohappenwhen
aprioritysignaloccurscanbefreelyprogrammed.Therecanbeautomatically
switchedtothepriorityaudioinputswhenaaudiosignalisapplied,ortheinternal
routingcanbeadaptedwhenasignalisavailableonthecontactinputs.
AdigitalS/PDIFin-andoutputconnectionisprovided,whichisbothcoaxialand
opticalimplemented.Thedigitalinputsignalscanberoutedjustliketheanalog
inputstothedesiredoutputzone.Thedigitaloutputscanbeprogrammedinaway
thatthereisafreelyselectablezoneoutputavailableonthischannel,withouta
volumecontrol.Thiscanbeusefulformakinglosslessrecordings.
Thelinkin-andoutputsareopticalfiberconnectorswhichcanbeusedfor
cascadingmultipleR2’s.Forthisfeature,theoptionalfiberinterconnectionmodule
hastobeinstalled..
Rear

15
Peripheral interfaces
10RJ45connectorsforexpansionwithadditionalwallpanelsandin-andoutput
modulesareprovided.AlltheseconnectorscarryRS485signals.Thisallowsthe
controloftheamplifierfrom10differentlocations.
8oftheseconnectorsareabletocarrydigitalaudiosignals(PI1toPI8)for
expansionwithadditionalwalllineinputunits.
TheRJ45remotecontrolinputshouldbeconnectedtoaLANnetwork.Thismakes
itpossibletocontroltheR2systemoverEthernet,bymeansofaweb-browser
oranyotherdevicesupportingEthernet.
TheRS232connectioncanbeusedtocontroltheR2withexternalcontrol
equipmentsupportingRS232.ThisallowstocoupletheR2withyourhome
automationsystem,andcontrolitthroughhardwareofothermanufacturers,like
AMX,Crestron,….
Control ports
Chapter 3
Wire up the system
Thewiringofthesystemmustbedoneaccordingtothefollowingrules,toguaranteeaproperfunctioning
ofthesysteminallcircumstances.
1. Speakercableforamplifiedzoneoutputs:minimum2x1.5mm²
(distance>15m:2x2.5mm²)
2. WallMountedInput&Controlunits: DW3018/4018 UTP/FTPCat5cableorbetter
DW5065 UTP/FTPCat6cableorbetter
APM UTP/FTPCat6cableorbetter
3. Musicsourcesandlinelevelzoneoutputs:mustbeconnectedwithhighqualityaudiocableand
connectors.
4. Ethernetconnection:UTP/FTPCat5cableorbetter

16
Chapter 4
R2 Quick start guide
This chapter guides you through the setup process of a basic project with one R2 audio matrix
and 8 standard DW3018/4018 wall panels.
Overview of the R2 setup
Connecting the R2
1) Connecting audio sources
Connectallyouraudiosources(CD-players,tuners,...)tothelineinputs(RCAconnectors)ontherear
paneloftheR2.Adjustallinputgainstotheappropriatelevelsonoclippingoccurs.
2) Connecting amplifiers and/or speakers
Connectamplifiers(100Vorlowimpedance)tothelineoutputs(RCAconnectors)ontherearpanelofthe
R2.Whentheoptionalpoweramplifierkitisinstalled,lowimpedanceloudspeakerscanbeconnectedto
theloudspeakeroutputs(Euroblockterminalconnectors)ontherearsideoftheR2.
3) Connecting wall panels
ConnecttheDW3018/4018wallpanelstothePI(PeripheralInterface)inputs(RJ45connectors)onrear
paneloftheR2.MultipleDW3018/4018wallpanelscanbeconnectedtoonesinglePIinputbyusingbus
cabling(connectingallthewallpanelsinparallel),oreachwallpanelcanbeconnectedtoanPIinputby
aseparatecable.Itdoesn’tmatterwhichPIportisusedforwhichzone,thesettingsforwhichwallpanel
shouldcontrolwhichzonecanbemadeintheuserinterface.
4) Connecting a computer
AcomputercanbeconnectedtotheR2throughtrueethernet.Ifthecomputerisdirectlyconnectedtothe
R2,acrossednetworkcableisnecessary.IftheR2isconnectedtoalocalLANnetwork(connectedtoa
router/switch/hub)astraightnetworkcableisnecessary.AskyourITadministratorforhelp.
Togetaccesstotheuserinterface,enterthefollowingaddressinyourinternetbrowseraddressbar:
“http://192.168.0.191”(ThisisthefactorydefaultIPaddressoftheR2,canbechangedintheuser
interface).Thedefaultadministratorpassword(givesyouaccesstoallfunctions)is“R2”andthedefault
userpassword(givesyouonlyaccesstothebasicfunctions)is“user”.Ifyouwanttomakeanychangesto
thesettings,youshouldlog-inwiththeadministratorpassword.
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Prog.
Vol
+
-
+
-
Audiosources
Amplifiers
Wallpanels

17
Configuring the R2
1) Changing the IP address
YoucanskipthisstepwhenthedefaultIPaddress“192.168.0.191”isnotusedbyanotherdeviceinyour
network,andisOKforyou.IfyouliketochangetheIPaddress,gotothe“Setup”menu(clicktheicon
intheupperrightcornerofthemainscreen)andclick“NetworkSettings”.NowyoucanchangetheIP
address,andclick“OK”toapplythechangesandsave.Afterwards,yourbrowserwillbeautomatically
redirectedtothenewIPaddressoftheR2,andthedefaultIPaddressisnotlongervalid.
2) Changing the password
Youcanskipthisstepifthedefaultpassword“R2”foradministratorand“user”forusersisOKforyou,
buywealwaysrecommendtochangethesepasswords,especiallywhenyourR2isconnectedtoapublic
networkwhereexternalusershaveaccessto.Ifyouliketochangethepassword,gotothe“Setup”menu
andclick“Passwordsettings”.Hereyoucanchangethepasswords.First,theoldpasswordneedstobe
entered,andsubsequentlythenewpasswordneedstobeenteredtwice(Max10characters).Pressthe
“OK”buttontosavethenewpassword.Now,youalwaysneedtolog-inwiththenewpasswordsandthe
defaultpasswordsarenotlongervalid.
3) Configuring wall panels and sources
Gotothe“Setup”menuandclick“Systemconfiguration”.Nowyouhavethepossibilitytochoosebetween
“Paging”,“DW5065”and“DW3018/4018”.ToconfigurethesettingsfortheDW3018/4018wallpanels,
clickthecorrespondingbutton.Bythedropdownlistontheleftside,youcanchooseforwhichzoneyou
wanttoconfigureawallpanel.Afterthedesiredzoneisselected,youcanassignoneoftheconnected
wallpanelswiththatparticularzonebyclicking“SetAddress”.Thedisplaysonallwallpanelswillstart
blinkingwiththeselectedzonenumber.Pushthe“Program+”buttononthewallpanelifyouwantto
assignthatparticularwallpanelwiththeselectedzone.Afterthe“Program+”buttonispressed,thewall
panelwillbelinkedwiththeselectedzone,andthedisplaywillstopblinking.
TheR2containsmanydifferentinputswhichcanbeselectedtolinkwithazone.8ofthoseinputsare
accessiblethroughthe“Quickmenu”(dropdownlistonthemainpage).Thesameinputswhichare
availableinthe“Quickmenu”canbeselectedontheDW3018/4018wallpanels.Theotherinputsare
accessiblethroughthesettingsmenuifyouarelogged-inasadministrator.
Youcanchoosetheinputswhichareselectableinthe“Quickmenu”andbymeansoftheDW3018/4018
wallpanelsinthewallpanelsettingsmenu(Standardarelineinputs1to8selected).Simplyselectthe
desiredinputsignalsbythedropdownlistsnexttothecorrespondingnumbersontherightsideofthe
window.Afterthedesiredinputchannelsareselected,clickthe“Setwallpanelinputs”buttontosavethe
changes.Theselectedinputsarenowselectableinthe“Quickmenu”andbymeansofthewallpanel.
Ready
Yoursystemisnowreadyforusewiththewallpanels.

18

19
Chapter 5
User interface & configuration
Togetaccesstothecontrolandconfigurationsettings,theR2shouldbeconnectedtoacomputeroran
EthernetLANnetwork.Formoreinformationaboutnetworkconnectionsandsettings,seeIPbasicsin
chapter8.
Thestandard(factorydefault)IPaddressoftheR2is192.168.0.191,makesurethisaddressiswithin
theIPrangeoftheconnectedEthernetLANnetwork(subnetmask255.255.255.0).Ifthedefaultnetwork
addressisnotwithinrangeofyourLANnetwork,contactyournetworkspecialist.Thenetworkaddress
canbechangedwiththeStandardWebBasedUserInterfacebutthereforeanetworkconnectionhastobe
madefirst!
Anydevice(PC,Laptop,PDAorevenaSmartphone)withawebbrowserandtheMacromediaFlash8.0
plug-in(orhigher)installed,canbeusedtocontrolthewebbaseduserinterface.
Formobiledevices,suchasPDA’s,smartphonesoreveniPhonesoriPads,specialapplicationsare
developedtocontrolthestandardfunctionsoftheR2Matrix.
Open the user interface
Start your default web browser and enter in the address bar the IP address of the embedded web server of the
R2. (The factory default IP address is http://192.168.0.191).
If multiple R2’s are cascased with each other through the fiber interconnection interface, first a selection screen
will be displayed whereby the R2 should be selected which you want to control.
Login screen
Firsttheloginscreenwillbedisplayed.
ApasswordshouldbeenteredtogetaccesstothewebinterfaceoftheR2amplifier.
Therearetwodifferentaccesslevels,administratorlevelanduserlevel.
Ifyoulog-inusingtheadministratorpassword,yougetaccesstoallfunctionsandconfigurationoptions
oftheR2Amplifier(Thefactorydefaultpasswordforadministratoraccesis“R2”).
Whenyoulog-inusingtheuser password,youonlygetaccesstothebasicfunctionsoftheR2Amplifier,
suchaschangingthevolumeandchangingtheroutingforaparticularoutputzone.(Thefactorydefault
passwordforuseraccesis“user”).
Aftertherightpasswordisentered,clickthe“OK”button,andyouwillberedirectedtothemainscreenof
theR2interface.
NOTE
ThepasswordscanbechangedintheConfiguration>>Passwordsettingsmenu(Onlyadministrator)

20
Main screen
Themainscreendisplaysall8outputzonesoftheR2withfadervolumecontrols.
Volume control
Thevolumeofeachchannelcanbesetbymovingthefaderofthecorrespondingchannelupordown.
Atthetopandbottomsideofeachfaderisabuttonwithanarrowdisplayedwherebythevolumecanbe
raisedorloweredinstepsof1dB.Atthebottomisa“Mute”buttonprovidedwhichmutesthevolumeof
thecorrespondingoutputchannelinoneclick.Afterthevolumeismuted,thismutebuttonwillbecome
Red,andthevolumecanbeunmutedafterclickingitagain.
Assign zone names
Forabetteroverviewofalloutputchannels,everyfadercanbeassignedbyaspecificzonenameas
shownintheexamplebelow.Thenameofthezonecanbechangedbydoubleclickingonthenamewhich
isdisplayedabovethecorrespondingfader(indicatedinthepicturebelowwith“ZoneName”).Whena
cursorcomesup,removetheexistingnamewiththebackspacekey,andjustchangethenameinthe
desiredname.Clickonthe“SaveZoneSettings”buttonandconfirmtosavethechangedzonesettings.
Thenameofthecorrespondingzonewillbechanged,andnexttimeyoulogintothewebbaseduser
interfaceoftheR2thesamezonenamewillbedisplayed.
Connection status
Inthetopleftcornerofthewindowisthe“ConnectionStatus”displayed.Tohavecommunicationwiththe
R2,theconnectionstatusmustbe“ONLINE”.
Input channel selection
Thedesiredinputsignalforaparticularzonecanbeselectedbyusingthedropdownlistboxbelowthe
zonename.Thisdropdownlistshows8audioinputsignalswhichareselectedasstandardinputsinthe
“SystemConfiguration”menu,togetherwiththenoptions“Off”and“Other”.Whennoinputsignalis
selected,theoption“Off”willappear.Whenaspecialinputneedtobeselectedwhichisnotselectedas
oneofthe8standardinputsinthe“SystemConfiguration”menu,thisshouldbedonebymeansofthe
“Settings”menu,whichcanbeobtainedbyclickingthe“Settings”buttonbelowthe“InputSelection”
dropdownlist.Inthiscase,theoption“Other”willappear.Inthe“Settings”menu,othersettingssuchas
tonecontrolordigitalfiltersettingscanbemadetoo.
Configuration menu
Inthetoprightcornerisa“Setup”buttondisplayed.Afterclickingthisbutton,youwillberedirectedtothe
generalconfigurationmenuoftheR2.
R2 Main screen
Other manuals for R2
2
Table of contents
Other AUDAC Matrix Switcher manuals