Mdel JGBR
Type Wired system receiver designed for
230v AC heating applications
Cntr l O-OFF control
Envir nment Ratings
Operating Temperature 0ºC to +50ºC
St rage Temperature -20ºC to +60ºC
Operating Humidity 5-95 %RH
Switch V ltage 0-230v AC 16AMP
P wer S urce 230v AC 50Hz
User Interface Slide switch, Bi Colour LED, RED/GREE
Operating Temperature 0ºC to 50ºC
St rage Temperature -20ºC to 60ºC
Frequency 2.4 GHz
Terminal Functi n
COM Common Contact (volt free input)
NO ormally Open Contact (volt free output)
Earth Parking
LIncoming Mains - Live
NIncoming Mains - eutral
Use schematics to wire up, selecting
RX1 or RX2.
Clip the front of the unit back on by
aligning the fittings and pushing into place.
Securely screw the front of the receiver
in place.
Loosen the screws at the bottom of the
receiver unit.
Unclip the front of the unit.
Fit the back of the receiver unit to the
wall using the fittings supplied.
www.speedfitUFH.co.uk
For models:
JGSTATW2W
JGSTATW2B
JGSTATW1W
JGSTATW1B
Installation Manual
Wireless Thermostats
230v and Battery Operated
Ensure Coordinator is powered up
and ready for pairing.
Power up the receiver.
The red light will flash.
When the receiver has successfully
joined the Zigbee network, the red
LED will go steady.
Please refer to JGSTATW1
/JGSTATW2 Installation Manual for
system pairing.
Once your system setup is
complete, remember to take the
coordinator out of pairing mode.
Electrical Connection Power Up
The JGBR Receiver should be mounted in a suitable location that is both
accessible for the connection of mains and control wiring, and allows good
reception of the wireless signal. The Receiver needs a 230v AC mains
supply to operate, and this should be fused appropriately (16A max.).
The Receiver should be mounted in a location where it will not come into
contact with water, moisture or condensation. There are few electrical
connections required to the JGBR, and these connections should be made
to the terminal block inside the Receiver. o Earth connection is required
for the correct and safe operation of the JGBR, but a parking terminal is
provided to connect an Earth wire if one is present.
Installer NotesInstaller Notes
Tec nical Detail
Installation
2
3
4
5
1
65
43
21
J hn Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233
Fax: 01895 420321
www.speedfitUFH.co.uk
Technical Help Desk: 01895 425333
,
The above namestyles are all trademarks of John Guest International Limited.
©John Guest International Limited 2014. All rights reser ved.
Z2105/420/1114
and
www.speedfitUFH.co.uk
For model:
JGBR
Instruction Manual
Boiler Receiver
Instruction Manual Boiler Receiver JGBRScrews x 2
and Wall Plugs x 2
For latest PDF Instruction Manual please go to
www.speedfitUFH.co.uk
230v AC
Warning. Always isolate the AC Mains supply before installing or working
on any components that require 230v AC 50Hz supply.
Sources of danger. The JGBR must be disconnected from mains
supply before removing the cover.
Emergency. Switch off the voltage to the individual thermostat, wiring
centre or complete system.
Warning. This product must be fitted by a competent person, and
installation must comply with the guidance, standards and regulations
applicable to the location where the product is installed. Failure to comply
with the requirements of the relevant guidance, standards and regulations
could lead to injury, death or prosecution.
Introduction. Thank you for purchasing the Speedfit Aura JGBR System
Receiver. This unit is designed to work with JG Aura range of Zigbee network
products.
The JGBR can be configured as remote boiler switch or a simple single channel
output to control, a thermal actuator or zone valve. Please note the two
configuratons above can be used together in the one system.
These instructions are applicable to the Aura model stated on the front cover
of this Instruction Manual only.
Product Compliance. This product is CE compliant and meets the
following EC Directives:
RoHS2 directive 2011/65/EU, Electro-Magnetic Compatibility directive
2004/108/EC and Low voltage directive 2006/95/EC.
The unit can be switched internally to use one of two channels, RX1 (boiler
receiver) or RX2 (single room receiver). Ensure the unit is not powered
during setting of the RX1/RX2 slide switch.
The unit is supplied with the switch in the RX1
position (Boiler Receiver). In this mode, the unit
can be wired to the boiler to switch it on or off
using the wireless signals it receives from other
Aura products on the Aura Zigbee network.
With the unit is switched to RX2, the unit will act as a single room receiver.
Switching of the unit will be controlled by a paired Aura
JGSTATW1/JGSTATW2 Thermostat. Depending on its intended use, the
unit can be used to switch a motorised valve, thermal actuator or pump.
As well as being used in this way, the RX2 can be
used in conjunction with another unit set up as an
RX1 (Boiler receiver). When there is a call for heat
from the thermostat paired to the RX2 both of the
wireless receivers will operate turning on both the
boiler and the motorised valve / pump.
Please note: Only one RX1 and one RX2 can be
used as part of a network.
System Receiver configured to boiler receiver RX1.
Refer to reverse side for wiring.
System receiver configured as stand alone receiver RX2.
Refer to reverse side for wiring.
User Interface
AUTO – The botom slide switch is
not active. System receiver output
will switch on and off in relation to
the command from the Aura
transmitter. The bottom slide switch
in active.
Manual - System receiver output is
controlled by the bottom slide
switch. Either permanently O or
OFF. The LED status in manual is
the same as AUTO.
RED and Green LED in AUTO -
There is an output from the
receiver. The device that the
receiver is connected to will be
switched on.
RED led nly in AUTO - There is
no output from the receiver.
JGSTATW1/
JGSTATW2
JGUFHA(240V)/2
JGBR configured
as Boiler Receiver RX1.
Switc Boiler
Switc Valve
JGBR configured as stand
alone receiver RX2.
JGWCW
2
3
4
1
JGTRV
Product Compliance & Safety Information System OverviewContents
System Overview - Aura System Configured as RX2System Overview - Aura System Configured as RX1
Icons used in t is manual:
Safety
Important info
Instruction Manual:
• Box contents
• Product Compliance
• User Interface
• Installation
• Technical Detail
• RX1 and RX2 Configuration
and System Overview
• Installers notes
Box Contents:
JGCO
NO (OUT)
COM (IN)
LL NN
LIVE
BOILER IN
BOILER OUT
LIVE SUPPLY
230v AC 50Hz
]
COM (IN)
NO (OUT)
NNLL
LIVE SUPPL
]
YLIVE SUPPL
BOILER OUT
BOILER IN
LIVE
230v AC
LIVE SUPPL
]
50Hz230v AC
YLIVE SUPPL
COM (IN)
NO (OUT)
OUT IN LNE
LLNN
*REMOVE THE LINK
(IF APPLICABLE)
LIVE SUPPLY
230v AC 50Hz
BOILER
THERMOSTAT
CONNECTION
NO (OUT)
COM (IN)
NO (OUT)
COM (IN)
LNNL
OUT
CONNECTION
THERMOST
ENL
INOUT
CONNECTION
T
A
ERMOST
A
BOILER
COM (IN)COM (IN)
50Hz230v AC
LIVE SUPPL
(IF APPLICABLE)
THEREMOVE
*
50Hz
YLIVE SUPPL
(IF APPLICABLE)
LINKTHE
Reset Butt n - If for any reason the system receiver stops
operating, press reset and check system operation.
Configured as RX1 Configured as RX2
Replacing the System Receiver - If for any reason the
system receiver needs to be removed/replaced, press the
delete from network buttom.
Please n te - Grey and orange wires are used for boiler switching and
connected to the Boiler Thermostat terminals. If RX2 Receiver is used in
conjunction with an RX1 Wireless Receiver then these connections can be
discarded as there will be communication between RX1 and RX2.
Sc ematics

Other Aura Receiver manuals

Aura AMH-320BT User manual

Aura

Aura AMH-320BT User manual

Aura AMH-79DSP User manual

Aura

Aura AMH-79DSP User manual

Aura AMH-520BT User manual

Aura

Aura AMH-520BT User manual

Popular Receiver manuals by other brands

Icom IC-PCR1500 Service manual

Icom

Icom IC-PCR1500 Service manual

Icom IP100H quick guide

Icom

Icom IP100H quick guide

UGREEN CM523 user manual

UGREEN

UGREEN CM523 user manual

Delphi SkyFi2 SA10102 user manual

Delphi

Delphi SkyFi2 SA10102 user manual

Zte ZXSDR RSUC user manual

Zte

Zte ZXSDR RSUC user manual

Intermatic ML815TK Setup instructions

Intermatic

Intermatic ML815TK Setup instructions

Kongsberg Simrad SR70 installation manual

Kongsberg

Kongsberg Simrad SR70 installation manual

ViewSonic HDMR-2000 user guide

ViewSonic

ViewSonic HDMR-2000 user guide

Pioneer VSX-D514 operating instructions

Pioneer

Pioneer VSX-D514 operating instructions

Hi-Target V60 Getting started

Hi-Target

Hi-Target V60 Getting started

Sennheiser SET 820 S RF Technical data

Sennheiser

Sennheiser SET 820 S RF Technical data

Magnetek MHR manual

Magnetek

Magnetek MHR manual

Sony STR-DG500 - Multi Channel Av Receiver Specifications

Sony

Sony STR-DG500 - Multi Channel Av Receiver Specifications

Pioneer MVH-1450UB owner's manual

Pioneer

Pioneer MVH-1450UB owner's manual

PCB Piezotronics JM353B15 Installation and operating manual

PCB Piezotronics

PCB Piezotronics JM353B15 Installation and operating manual

Denon AVR-488 owner's manual

Denon

Denon AVR-488 owner's manual

Denon AVR-987 Specifications

Denon

Denon AVR-987 Specifications

ComNav SinoGNSS M300 Mini(G) QuickTour

ComNav

ComNav SinoGNSS M300 Mini(G) QuickTour

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.