auray SVRK Series User manual

Server Rack
(4/6/9/12U) (Shallow/Deep)
Owner’s Manual
SVRK SERIES

2SVRK SERIESOwner’s Manual
Thank you for choosing Auray.
Auray’s server racks come in shallow and deep 4-, 6-, 9-,
and 12-space configurations. Vented top and side panels
promote airflow throughout the rack, and all racks are
configured to accept optional rack fans. Front and back rack
rails are included to install rack shelves and large devices
that need four-corner support. Each model can be used as
stand-alone unit or wall mounted via the rack’s key holes or
an included wall-mount bracket. Side panels and a locking
door are included to limit access to the installed devices.

3SVRK SERIES Owner’s Manual
• Please read and follow these instructions,
and keep this manual in a safe place.
• Use only parts provided by the manufacturer.
• Do not exceed the weight capacity of this product.
• This product is for indoor use only.
• Make sure the mounting surface and the wall attachments
can support the weight of the rack and installed equipment.
• Make sure everything is secure before proceeding.
• Make sure that this product is intact and
that there are no missing parts.
• Keep this product away from water and
any flammable gases or liquids.
• Do not stack the rack on top of another rack.
• This rack requires an earth ground connection. Do not
use this product without an earth ground connection.
• Do not overtighten or improperly thread
any of the threaded fittings.
• All images are for illustrative purposes only.
Precautions

4SVRK SERIESOwner’s Manual
Bottom panel 1
Top panel 2
Side bracket (×2) 3
Side panel (×2) 4
Right angle vertical rail (×2)
5
Left angle vertical rail (×2)
6
Front door 7
Back panel 8
Cable port cover (×2) 9
Wall mount bracket 10
Overview
1
2
3×2
8
10
7
4×2
5×2
6×2
9×2

5SVRK SERIES Owner’s Manual
M6×11 screws (×16)A
M6×12 screws (×8)B
M6 cage nuts
Rubber pads (×10)
Small plugs (×8)
M4×10 screws (×10)C
Door hinge plugs (×2)
Small washers (×3)
Lock cylinder
Plastic lock washer
Metal hex washer
Door latch
Door latch screw
Keys (×2)
Side door plugs (×2)
Assembly and Mounting Hardware
M6×14 screws (silver) (×10) M6 cage nuts (silver) (×10)
For Rack Equipment
Phillips screwdriver
Tools Required for Assembly
IMPEDANCE PROTECTED
AC 50/60Hz , 110 V/0 .15 A
80CFM, 48 dBA , 13W
RKFN-1 / Rack Fan
Made in C hina
QG1010
Screw Identifier
M6×11 M6×12 M4×10
A B C

6SVRK SERIESOwner’s Manual
Assembling the Rack
1. Lay the bottom
panel on a flat
surface. The
slotted edge is the
front of the rack.
2. Insert the side
brackets onto
the bottom panel
so the mounting
keyholes are at the
back, and the depth
adjustment rails
are on the inside of
the chassis.
Important! The depth adjustment rails should not be
flush against the sides of the bottom panel. If they are,
switch the left and right side brackets so the depth
adjustment rails are about an inch inside the edges of
the bottom panel.
If the side doors are preinstalled into the side
brackets, press the two locking tabs inward and
remove the doors to perform the next step.

7SVRK SERIES Owner’s Manual
3. Determine where
the vertical rails
will go inside the
rack, and attach
cage nuts to the top
and bottom depth
adjustment rails.
To install cage
nuts, fit one of
the clamps into
the hole, apply
pressure until
the other clamp
fits into the hole,
and release.
Cage nuts can be
installed by hand
or with the help
of a screwdriver
or cage nut
tool (available
separately).
The front vertical rails will attach flush to the
front of the rack. However, if you want to attach
the door, you need to measure how far back you
need to place your gear so the door can close.

8SVRK SERIESOwner’s Manual
To install a rack shelf or a large device that needs
back-side support, measure the distance you
need, and use the same method to attach the
rear vertical rails at the appropriate depth.
Once you have determined where to attach the cage
nuts, attaching the vertical rails in the next step might
be easier by removing the side brackets and attaching
the rails before proceeding with assembling the rack.
4. Attach the vertical
rails to the depth
adjustment rails
by screwing them
into the cage nuts
with M6×12 screws.
Install the front vertical rails with the printed
U-space guide and square holes facing front.
Attach the rear rails with the printed U-space guide
facing front or back, depending on your needs.

9SVRK SERIES Owner’s Manual
5. Fit the top panel over the assembly. Make sure
the beveled vented edge is in the front.
6. With the assembly in the upright position, use the M6
screws to attach the top panel to the side panels.
ATop screws
(×4)
BTop front and
back screws (×4)
CBottom front
and back (×4)
A
C
B

10 SVRK SERIESOwner’s Manual
7. Place the assembly on its side, and attach the side
panels to the bottom panel with M6 screws. (×4)

11SVRK SERIES Owner’s Manual
Attaching the Fans
The Auray RKFN-1 (sold separately) is a dedicated fan
for this server rack. It installs inside the top panel and
can be used as exhaust or to blow air into the rack.
Air flows toward the fan’s label.
To attach the fan inside the rack, use the mounting screws
that are included with the fan, and follow these steps:
1. Determine the air flow
direction, and place
the fan inside the top
panel. Align the fans
with the mounting
holes inside the top
panel.
2. Screw in the fans
from the outside of the
top panel until secure.
IMPEDANCE P ROTECTED
AC 50/6 0Hz, 110V/0 .15 A
80CFM , 48dBA, 13W
RKFN-1 / Rack Fan
Made in Chi na
QG1010
IMPEDANCE P ROTECTED
AC 50/6 0Hz, 110V/0 .15 A
80CFM , 48dBA, 13W
RKFN-1 / Rack Fan
Made in Chi na
QG1010
IMPEDANCE PROT ECTED
AC 50/60Hz, 110 V/0.1 5A
80CFM, 48dBA , 13W
RKFN-1 / Rack Fan
Made in C hina
QG1010
Important! A ground cable is attached
to the front side of the fan and is set to
be installed for exhaust. If you want the
fan to blow air into the rack, unscrew
the ground cable, and attach it to the
other side of the fan. This will allow the
fan to mount flush to the top panel.
IMPEDANCE PROTECTED
AC 50/60Hz, 110 V/0.15A
80CFM, 48dBA, 13W
RKFN-1 / Rack Fan
Made in China
QG1010
IMPEDANCE PROTECTED
AC 50/60Hz, 110 V/0.15A
80CFM, 48dBA, 13W
RKFN-1 / Rack Fan
Made in China
QG1010

12 SVRK SERIESOwner’s Manual
Installing Devices
When installing equipment, install the heaviest devices
at the bottom of the rack first, and continue to install
the lighter devices as you work your way up.
1. Determine the U-space of your device and where in
the rack you want to install it. Use the U-space guides
printed on the rails to determine where to install the
silver M6 cage nuts.
2. Use the included silver M6×14 screws
to secure the devices in place.

13SVRK SERIES Owner’s Manual
Completing the Rack Assembly
Determine if cables will run through the top and bottom
cable ports or the back of the rack. If these openings
are not going to be used, you can cover them to create
a complete enclosure for your installed equipment.
1. Attach the back panel with the M4×10 screws.
2. Attach the top and bottom cable port
covers with the M4×10 screws.

14 SVRK SERIESOwner’s Manual
Side Panels
1. Press the
rubber pads
into the holes
on the side
panels.
(×4 per side)
2. Place the small plugs
in the top and bottom
holes on the side
panels. (×4 per side)
3. Attach the side
panels by placing the
bottom tabs into the
slots, and pressing
in the top until it
locks into place.
4. If needed,
press the
door plugs
into the side
door holes.

15SVRK SERIES Owner’s Manual
Attaching the Mounting Bracket
1. Slide the mounting bracket into the back of the rack
so the indented tabs are inside the rack, the bracket
should be flush against the back of the rack.
2. Attach the bracket with M4 screws (×2)
Attaching the Door
The door attaches to the
rack to open from the left.
1. Place the door hinge
plugs into the door holes
on the right side of the
top and bottom panels.

16 SVRK SERIESOwner’s Manual
2. Place the three
washers onto the
bottom door pin.
3. Fit the bottom door pin into
the hinge plug on the bottom
panel. Pull down the top door
pin, slide it into position
under the top hinge plug,
and release the door tab.
The door should smoothly
swing open and closed.

17SVRK SERIES Owner’s Manual
Installing the Door Lock
1. Remove the metal hex washer and the plastic
washer from the cylinder, and unscrew the
Phillips screw from the end of the cylinder.
2. Fit the cylinder through the hole.
3. Slide the plastic washer over the cylinder
threads. Then screw the metal washer onto the
threads, making sure the textured side faces
the plastic washer. Tighten until secure.
4. Place the latch onto the end of the cylinder, and
attach it with the screw.
When you attach the latch, use
the key to make sure it’s oriented
toward the edge of the rack so the
door will lock.

18 SVRK SERIESOwner’s Manual
Form Factor: 19 in. rack
Load Capacity: 132.3 lb. (60 kg)
Cooling: Optional fan
Dimensions: SVRK-4U-S: 23.6 × 17.7 × 10.9 in. (60 × 45 × 27.7 cm)
SVRK-6U-S: 23.6 × 17.7 × 14.4 in. (60 × 45 × 36.7 cm)
SVRK-9U-S: 23.6 × 17.7 × 19.7 in. (60 × 45 × 50 cm)
SVRK-12U-S: 23.6 × 17.7 × 24.9 in. (60 × 45 × 63.3 cm)
SVRK-4U-D: 23.6 × 23.6 × 10.9 in. (60 × 60 × 27.7 cm)
SVRK-6U-D: 23.6 × 23.6 × 14.4 in. (60 × 60 × 36.7 cm)
SVRK-9U-D: 23.6 × 23.6 × 19.7 in. (60 × 60 × 50 cm)
SVRK-12U-D: 23.6 × 23.6 × 24.9 in. (60 × 60 × 63.3 cm)
Weight: SVRK-4U-S: 27.5 lb. (12.5 kg)
SVRK-6U-S: 32 lb. (14.5 kg)
SVRK-9U-S: 37.4 lb. (17 kg)
SVRK-12U-S: 41.9 lb. (19 kg)
SVRK-4U-D: 32 lb. (14.5 kg)
SVRK-6U-D: 37.4 lb. (17 kg)
SVRK-9U-D: 44.1 lb. (20 kg)
SVRK-12U-D: 51.8 lb. (23.5 kg)
Specifications

19SVRK SERIES Owner’s Manual
This Auray product is warranted to the original purchaser to be free from
defects in materials and workmanship under normal consumer use
for a period of one (1) year from the original purchase date or thirty (30)
days after replacement, whichever occurs later. The warranty provider’s
responsibility with respect to this limited warranty shall be limited solely to
repair or replacement, at the provider’s discretion, of any product that fails
during normal use of this product in its intended manner and in its intended
environment. Inoperability of the product or part(s) shall be determined by
the warranty provider. If the product has been discontinued, the warranty
provider reserves the right to replace it with a model of equivalent quality
and function.
This warranty does not cover damage or defect caused by misuse, neglect,
accident, alteration, abuse, improper installation or maintenance. EXCEPT
AS PROVIDED HEREIN, THE WARRANTY PROVIDER MAKES NEITHER ANY
EXPRESS WARRANTIES NOR ANY IMPLIED WARRANTIES, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE. This warranty provides you
with specific legal rights, and you may also have additional rights that vary
from state to state.
To obtain warranty coverage, contact the Auray Customer Service
Department to obtain a return merchandise authorization (“RMA”) number,
and return the defective product to Auray along with the RMA number and
proof of purchase. Shipment of the defective product is at the purchaser’s
own risk and expense.
For more information or to arrange service, visit www.aurayaudio.com or
call Customer Service at 212-594-2353.
Product warranty provided by the Gradus Group.
www.gradusgroup.com
AURAY is a registered trademark of the Gradus Group. © 2023 Gradus Group LLC. All Rights Reserved.
One-Year Limited Warranty

GG2
Table of contents
Other auray Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Whalen
Whalen Mainstays MS18-D2-1011-06 manual

AmazonBasics
AmazonBasics B0735CV8MB Welcome guide

Digital Watchdog
Digital Watchdog DWC-MTTWM quick start guide

Satco
Satco Nuvo 65-497 Installation and safety instructions

PROAIM
PROAIM SnapRig GP205 Assembly manual

InFocus
InFocus LP 740 LiteMount installation guide