AusClimate AU1910DD User manual

USER MANUAL
Ausclimate Cool Seasons Premium 10L
Desiccant Dehumidifier
Model: AU1910DD
Please read this user manual before operating

IMPORTANT SAFETY INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
WARNING - This appliance is intended for use in a domestic or office environment only.
Any other use is not recommended by the manufacturer and may cause fire, electrical
shocks or other injury to person or property.
When using electrical appliances, basic safety precautions should always be followed:
1.
Do not operate the unit with a damaged power supply cord or power plug, or after it
malfunctions or has been dropped or damaged in any way. If the supply cord or plug is
damaged, it must be replaced by the manufacturer, the distributor, its service agent or
similarly authorised qualified persons in order to avoid a hazard.
2.
This unit should always be kept in an upright position to avoid any damage. Place the
unit on a flat stable surface.
3.
Check the household voltage to ensure it matches the unit’s rated specification before
operating.
4.
Operate this unit in an ambient temperature between 1°C and 40°C.
5.
Ensure that the air inlets and outlets are not blocked or covered.
6.
Do not place the unit too close to curtains or other furnishings - min 20cm.
7.
When using the "LAUNDRY MODE" to speed up the drying of wet clothes in the room,
please keep the clothing at a safe distance from the unit to prevent water from dripping
onto the unit.
8.
Never place anything on top of the unit and do not cover with any kind of material while in
use.
9.
This product is intended for domestic and office use ONLY and not for commercial,
industrial or outdoor use.
10.
To protect against electrical shocks, do not immerse unit, power cord or power plug in
water, or spray with liquids.
11.
Never unplug the power cord without pressing the "ON/OFF" key to “OFF” first, as this could
damage the unit.
12.
Always unplug the unit when not in use or moving it to a new location. To disconnect from the
power supply, grip the plug to pull from the power socket. Never pull by the cord.
13.
Always empty the water tank before storing the unit away.
14.
Close supervision is necessary when any appliance is used near children and pets.
15.
Do not run power cord under carpet, or cover the power cord with rugs or runners. Arrange
the power cord away from areas where it may be tripped over.
16.
Never operate or store the unit in direct sunlight.
17.
If authorised by the distributor, repairs may be undertaken by a qualified service
technician. Repairs carried out by unqualified people may cause damage to the unit, damage to
property or injury to persons and void the warranty.
18.
Where possible, don’t use an extension power lead as the cable may overheat and cause
a risk of fire. Only use an extension lead after ensuring it is in perfect condition.
19. Do not use the unit without the air filter and make sure that the filter is kept clean to avoid
malfunction and invalidating the warranty.
SAVE AND READ THESE IMPORTANT SAFETY INSTRUCTIONS
1
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.

FEATURES
(Non) Compressor dehumidifier ~ uses desiccant rotor technology
Environmentally friendly with no harmful gasses & quiet operation
Moisture removal ~ 10 litres/day (20 C, 60% RH)
Water tank capacity ~ 3 litres
Nano-silver embedded in the air filter
~
kills bacteria on contact improving the quality of air in your home or office
~ Anti-bacterial nano-silver embedded in each filter string
~ Over 99% anti-bacteria performance
~ The filter may be cleaned by use of vacuum cleaner
~ The filter may also be washed by water and still retain performance
Laundry mode ~ includes power saving setting for warm
temperatures & turbo setting for winter
Up to 12-hour timer ~ for added convenience
Temperature range for use ~ 1 C - 40 C
Light & portable with carry handle
Removable water bucket with handle
Auto restart after power cut
~ Once the power is restored after a power failure,
the appliance will continue to operate at the selected
settings prior to the power failure.
Automatic louver wide range (max 150o)
~ 3-stage automatic air swing to meet your needs.
2
leave the clothes
more than 40cm
away

TIMER LAUNDRY
MODE
DRY
MODE
SWING ON/OFF Check
Full
Wide
Front
UP
8H
12H
4H
2H
Turbo
Saving
High
Low
Auto
PRODUCT DESCRIPTION
THE CONTROL PANEL
3
Control panel
Bucket
Air outlet
Auto louver
Water level
indicator
Air intlet
Filter
Handle
Drain hole
Dry Mode
indicator
Laundry Mode
indicator
Timer
indicator
Swing
indicator
Louver Swing
key
Laundry Mode
key
Timer key Dry Mode key
Water full
indicator
Check
indicator
Power key

UNIT SETUP
Place the unit in an upright position on a stable, flat surface.
Ensure the unit is a safe distance away from a
wall or furniture (see the right graphic).
Keep clothes at a safe distance from
air outlet of the unit and prevent water
dripping into the unit.
Where to position your
dehumidifier?
For best results position the
dehumidifier somewhere central,
such as the middle of the room or
a hallway. Do not position in front
of a radiator or in direct sunlight.
TO OPERATE SAFELY
4
Air inlet
Air outlet
Top
above 60cm
above 20cm
above 20cm
above 50cm
above 20cm
Do not insert small
objects into the unit as
this way may caused
damage or possible
hazard.
Keep suitable space
as above.
Ensure bucket is fitted correctly.
If the bucket is full or is not in
place, the “FULL” lights up and
the unit stops.
Do not remove
bucket when running
or water may leak.

OPERATING INSTRUCTIONS
ON and OFF
Connect the power plug to the appropriate electrical socket outlet.
Press the ON/OFF button to turn the unit ON.
Press the ON/OFF button again to turn the unit OFF.
Note: In the event of a power failure
Once the power is restored after a power failure, the unit will
continue to operate at the selected settings prior to the power
failure. This includes the drying mode, swing function and time
remaining in timer mode.
Note: After turning the appliance OFF
After turning the unit OFF using the ON/OFF button, the fan will
continue to run for a two-minute period. This is a normal procedure
and helps to cool & protect the internal components.
During this two-minute period, DO NOT remove the power plug from
the power socket outlet; wait for the fan to stop running.
DRY MODE
Press the "DRY MODE" key for dehumidification (general drying of your home or office).
Note: There may be times when the fan speeds are the same for AUTO and LOW.
AUTO itself is not a fan speed but a target relative humidity set point that uses
either the low or high fan speeds to reach its target of 50-55%RH.
If the relative humidity of the room is close to or within this range, then switching
between LOW and AUTO will make no difference to the fan speed.
A
UTO LOW HIGH
MODE
AUTO
DESCRIPTION
To keep the room at a comfortable relative humidity (RH)
level
The unit automatically keeps room humidity around
50~55%RH with automatic high or low fan speed.
LOW
To run low fan speed
The unit automatically keeps room humidity around
50~55%RH with low fan speed and low heater.
HIGH
Super dry mode to prevent damp, condensation & mould
The unit automatically keeps room humidity around
40~45%RH to achieve quicker and efficient drying with
high fan speed and high heater.
5

OPERATING INSTRUCTIONS
LAUNDRY MODE
Press the "LAUNDRY MODE" key for drying clothes.
MODE DESCRIPTION
SAVING
Suitable for warmer temperatures to save power
The unit automatically provides high speed warm dry air to
assist in clothes drying with lower power, potentially achieving
room humidity levels of 50%~55%RH.
TURBO
Suitable in cooler winter temperatures to dry clothes faster
The unit automatically provides high speed warm dry air to
assist in clothes drying with higher power, potentially
achieving room humidity levels of 35%~40%RH.
AUTO SWING LOUVER
Press the "SWING" Key to select the preferred air louver angle.
UP FRONT
HOLD (LED OFF)
The louver modes are useful for speeding up the drying of washing, wardrobes and
walls because it directs the airflow towards the surface of these areas - water
molecules will be forced out faster.
SAVING TURBO
MODE DESCRIPTION
UP The automatic louver swings in an upward
range of approx. 100 .
0
The automatic louver swings in a front
range of approx. 50 .
0
FRONT
WIDE The automatic louver swings in a wide
range of approx. 150 .
0
HOLD The automatic louver stops swinging when you press
"SWING" key - turns the LED light off.
6
WIDE
TOP
FRONT
WIDE

OPERATING INSTRUCTIONS
TIMER
Press the "TIMER ” key to select your desired running time (2, 4 ,8 or 12 hours).
The unit will automatically switch off at the end of the selected time period.
As the time counts down the LED lights (8, 4 or 2 hours) will indicate the time remaining.
When no "TIMER" is set (the LED light is off), the unit will run continuously unless the
bucket is already full.
4hrs
continuous
(LED OFF)
The Timer mode is useful if you want to dry a load of washing in ‘Turbo’ laundry mode
and you know that it will take say, 4 hours and you wish to just run the unit at full
power for that time period.
7
2hrs 8hrs 12hrs

TO EMPTY THE WATER BUCKET
Clean the water bucket with clean water if needed. Do not
use solvents, abrasive materials or hot water.
Do not remove or damage the float in the bucket, or the unit
The bucket cover must be correctly fitted into position.
The "FULL" LED lights up if the bucket is not correctly fitted
TO DRAIN WATER
You may use 2 methods to remove the collected water: water
bucket or drain hose.
A drain hose with an inner diameter of 12mm is quite suitable for
continuous drainage (1.2M drain hose is included):
1. Use a screwdriver to remove the ‘knockout’ at the back of
the unit. Attach the tubing to the connector through the hole.
2. The drain hose should lead downwards away from the unit,
with no sharp bends to ensure uninterrupted drainage.
8
cannot work correctly.
into position.
1. When the water bucket is full, the "FULL" LED lights up and the unit stops in
a few minutes.
2. Do not move the unit or remove the water bucket if the machine is still operating.
Water may leak and cause damage to the unit or cause an electric shock.
3. To remove the water bucket, pull it out by gripping the bottom of the bucket, and
lift carefully.
4. Remove the cover of water bucket first, then pour the water away. Clean the
bucket and return the cover and the bucket to the correct position.
Lift by the handle
Pull bucket out
ABPour water away Restore the bucket
CD

MAINTENANCE
Cleaning the unit
1. Turn off the unit, wait for the fan to stop and unplug from the power socket.
2. Clean the surface with a soft damp cloth.
3. Dry thoroughly with a towel after cleaning.
4. To avoid damage, do not wash or splash the unit with water, or let water
drip into the air inlet or air outlet.
Cleaning the nano-silver air filter
If the filter is covered with dust, the airflow and the performance of the unit will
be affected. It is recommended to check and clean the pre-filter every month
or as required.
1. Turn off the unit and remove the filter from the unit.
2. The pre-filter can be washed and wiped gently.
3. Replace the filter in position.
Before placing into storage
1. Turn off the unit, wait for it to stop and unplug from the power socket.
2. Clean and dry the bucket, as well as the filter and the rest of the unit.
3. Clean the filter and the unit. Cover the unit to prevent it from gathering dust.
4. Store upright in a cool dry place.
5. Do not expose to direct sunlight.
9
pre-filter

TROUBLE-SHOOTING
Check the following before contacting technical support:
Problem Cause Solution
The unit does not
operate.
The power is not connected. Insert power plug into the power socket.
Power cord or power plug may be
damaged.
Inspect power cord and power plug for
damage. If damaged, do not use - contact
the retailer or distributor for advice.
Set the DRY MODE to ‘High’ or run
LAUNDRY MODE, which may further
reduce the humidity to 35-40% relative
humidity.
The device does
not dehumidify.
The water container is full. Empty the water from the container.
The water bucket has not been
replaced correctly.
Return the water bucket into the correct
position.
The air filter is clogged. Clean the air filter.
The temperature in the room where
the dehumidifier is operating is too
low.
The machine does not dehumidify below
1°C. Note: at such low temperatures, the
moisture in the room will be very low
anyway.
The relative humidity in the room
where the dehumidifier is operating is
too low.
The unit dries down to the target
relative humidity, then goes into ‘fan
only’ mode until the relative humidity
goes above the set point again.
The unit is not
drying quickly
enough.
The unit may have already reduced the
humidity in the room to one of the
targets of 50-55%.
The unit works,
but reduces the
relative humidity
insufficiently /
there is little
water in the water
tank.
The room/house is too large. This
dehumidifier can dry to about a medium
3 or 4 bedroom house.
We recommend using a dehumidifier
with a greater capacity, or ‘compressor’
dehumidifier.
There are too many sources of
moisture: showers, washing, clothes-
drying and cooking all puts moisture
into the air. Un-flued gas heating can
also add too much moisture into the air
for a dehumidifier to remove.
We recommend using a dehumidifier
with a greater capacity, or ‘compressor’
dehumidifier.
Consider using a different heat source to
an un-flued gas heater.
The air filter is blocked - the reduced
air flow is effecting performance.
Clean the air filter.
Unit is blowing
out warm air. Air is passed over a heating element
within the unit, prior to being blown
into the room. This is part of the
dehumidification process.
This is normal, a dehumidifier is not an
air cooler.
The unit is
noisy.
The air filter is blocked or the unit is
on an uneven surface.
Clean the filter and or put the unit on a
flat surface. A dehumidifier will also be
noisier on wooden floors than carpet.
The fan still runs
after I have
turned the unit
off.
The fan is cooling the internal heater. This is normal. The fan will run for
about 2 minutes after you press the
power button off. Wait for the fan to
stop, then turn the unit off at the wall.
The “Check” LED
is illuminated.
The unit may not be working properly
.
Clean the filter and leave to stand for 20
minutes. Ensure that the dehumidifier is
not in front of a hot radiator. If the
problem remains, then please contact
the retailer or distributor.
There is an odour
coming from the
unit.
The zeolite desiccant material may be
returning various household odours
back into the room during the
dehumidification process.
This odour is not harmful to humans or
pets. It
will not last long and is not a sign
of a fault.
10

11
SPECIFICATIONS
Model AU1910DD
Power supply AC 220-240V, 50Hz
Power input Low 420watts / High 730watts
Dehumidifying capacity 10 litres/day (20°C@60%RH)
Recommended room size 50m2or 125m3
Capacity water container 3 litres
Operating range 1 – 40°C
Dimensions (w x d x h) 317(w) x 213(d) x H499(h)mm
Noise levels Low 38, High 49 dBA
Power control Easy soft touch
Desiccant Zeolite
Drain hose 1.2M provided
Net weight 6.8kgs
For all after-sales enquiries and warranty details please visit our website
for contact information, or call 1800 122 100
This manual suits for next models
2
Table of contents
Other AusClimate Dehumidifier manuals