AutoFlo S2000 Service manual

FIG. 2
MANUAL WATER DRAIN
WATER PAN
TANK BAFFLE
BLOWER
INTERLOCK &
HUMIDISTAT CONN.
AUTO DRAIN CONN.
"T" ADAPTER STATUS LIGHTS
OVERFLOW
FOR DRAIN
VALVE DETAILS
SEE FIG. 8
WATER INLET
AUTOFLO ELECTRONIC STEAM UNIT - POWER HUMIDIFIER
MODELSS2000 ANDS2020
FOR GAS OR OIL FORCED AIR FURNACES, HEAT PUMPS AND ELECTRIC FURNACES
The AutoFlo Power Humidifier you have purchased has
been designed to be simple to operate and maintain.
Parts included in the Steam Humidifier package are:
1. Humidifier
2. Self Piercing Saddle Valve
3. Installation Instructions and Owners Manual
4. Mounting Template
5. Installation Hardware package
6. Insulation and tape
7. Automatic Drain Assembly
8. Humidistat - Autoflo Models 062000
Familiarizing yourself with the items listed in Figures 1
and 2 will assist you in installing and maintaining your
Steam Power Humidifier.
Options and additional parts recommended:
1. Overflow/drain lines - 5/8"ID & 3/8"ID high temperature hose
2. 2 hose clamps - 1" and 1/2"
3. Electrical wiring and connections
4. Water Hammer Arrester #WH 100
5. Zinc Anode #Z 100
Installation
Instructions &
Owner's Manual
This symbol on
the product means
the product is
listed by
Underwriters
Laboratories, Inc.
R
U
L
C
US
WATER INLET
WATER LEVEL
PROBE
HEATER
TEMPERATURE PROBE
FIG. 1

SIMPLIFIED INSTALLATION INSTRUCTIONS
DETAILED INSTALLATION INSTRUCTIONS
1. Insulate the water reservoir.
2. Select the mounting location on the duct and tape
on the mounting template.
3. Punch or drill the (8) 1/8" mountings holes.
4. Cut out the humidifier opening in the duct.
5. Insert the humidifier into the opening and screw in
place.
6. Connect the water line.
7. Connect an overflow line and automatic drain line.
8. Make 24 VAC electrical connections to blower
interlock.
9. Install and connect the humidistat.
10. Plug power cord into a grounded dedicated 120 VAC, 15
amp outlet for S2000 (240 VAC, 10 amp for S2020).
1.INSULATEWATERRESERVOIR
2.LOCATION
3.MOUNTINGTEMPLATE
4.DRILLHOLESANDCUTOPENINGS
With insulation foil side down, remove adhesive backing.
Align humidifier so that front side of unit meets long edge of
insulation. Fold insulation up onto sides of humidifier and
press firmly. Cut and apply 5 continuous strips from the tape
provided to seal the foil as shown. The tape will prevent the
sharpductedgesfromdamagingthefoil.
The steam humidifier can be installed in either warm air
supply or the cold air return ducts; however the preferred
location would be in the warm air supply duct of the heating
system. This humidifier does not require warm air to
evaporate the water in order to provide humidity, but it will
operate more efficiently in the warm air duct and less
condensateislikelytoform.
When selecting a location on the duct, be certain that there is
enough room in the duct for the water reservoir. There should
beatleastfive(5)inchesabovethe reservoirandthe reservoir
should not occupy more than about 25 percent of the duct
space.Ifthiscriteriacannotbemet,youshouldinstalltheunit
under the duct by means of the tank flange. A template is
provided for installing the unit under the duct, on the cold air
return.
If the humidifier is installed on fiberglass duct, the installer
mustprovidesomestructuralsupportforthe
mounting plate. The fiberglass duct alone will not support the
weight of the steam humidifier, which is 9 Lbs. empty and 15
Lbs.whenfullofwater.
NOTE: The Humidifier must be installed at a location
so that the 120 VAC (240 VAC for S2020) power
connections can be made without the use of an
extensioncord.
Two mounting templates are provided. Choose the correct
template for your mounting method. Tape the mounting
template to the duct. The template must be leveled using the
top of the cutout on the template. The template should be
locatedsothatthebottomofthereservoircut-outisflushwith
the inside of the bottom of the duct for horizontal duct. Since
most ducts are insulated this additional space, about one (1)
inch, must be accounted for when determining the location
for the bottom of the reservoir cut-out. If you are mounting it
undertheduct,makesuretheductislevel.
Use an electric drill, with grounded power cord, to drill eight
(8) mounting holes, 1/8" diameter, in the duct. These can be
drilled through the template at the locations indicated on the
template.
A saber saw or tin snips can be used to cut out the water
reservoiropening.
2
FIG. 3
USE TAPE TO SEAL
THE OUTSIDE EDGE
OF THE FOIL
(2 PLACES)
USE TAPE TO SEAL THE FOIL
TO THE FRONT MOUNTING PLATE
(3 PLACES-SIDES AND BOTTOM)
INSULATION
(FOIL SIDE OUT)
FRONT MOUNTING PLATE
FIG. 4
MOUNTING TEMPLATE
MODEL S2000 & S2020
1. TAPE TEMPLATE IN LEVEL POSITION.
2. DRILL (8) HOLES FOR SHEET METAL SCREWS
SHOWN ON TEMPLATE (DO NOT DRILL LARGER
THAN 1/8" DIAMETER.
3. CUT OUT SOLID LINE AREA AS MARKED.
4. MOUNT HUMIDIFIER PER INSTRUCTIONS.
CUT ON LINE
CUT ON LINE
CUT ON LINE
CUT ON LINE
P/N 094021B0037

5.WATERCONNECTIONS
8.WIRINGTHESTEAMHUMIDIFIER
6. MOUNTING THE STEAM HUMIDIFIER
7.STEAMOPERATION
A.WATERSUPPLYUSINGTHESADDLEVALVE
FURNISHEDWITHUNIT
A.INSTALLINGANDWIRINGTHEHUMIDISTAT
B.FIELDWIRING
IMPORTANTNOTE:
B.OVERFLOW&DRAINLINES
Installationinstructionsforthesaddlevalveareprintedon
the plastic bag containing the saddle valve and its
components. Tap into a 1/2” or 3/4” domestic hot water
line for best results, but a cold water line will do. Avoid
connectingtowaterlinesfromaReverseOsmosissystem.
NOTE:Neverinstallthesaddle valveonthebottomofthe
water pipe. Sediment in the water pipe may clog the
saddle valve. When tightening the hex compression nut,
tightenonlyenoughtoassuretherearenoleaks.
NOTE: Saddle valves do not meet plumbing codes in
some areas. A “T” fitting with a valve may be required to
meet code or, if low water pressure causes frequent water
alertsonthesteamhumidifier.
NOTE: Do not use any line which is served by a water
softener. If your home has a water softener, make the
waterconnectionsto awaterline upstream fromthe water
softener.A watersoftener isnotademineralizer.It merely
exchanges various hard ions for soft ions in the water.
These soft ions, or minerals, will build up in the
humidifier, causing the need for frequent servicing. The
evaporation of softened water may also produce a white
powder which may be carried into the duct system and,
ultimately,intoyourhome.
Note: Use a water hammer arrester (WH-100) if water
spikesoccurduringoperation.
A temperature sensor is mounted in the water reservoir of the
humidifier. As the water temperature increases to about 170
degrees F, the computer closes a set of blower relay contacts.
When the water cools to about 140 degrees F, the computer
willopentherelaycontacts.
A humidistat, such as the AutoFlo Models 052000 or
062000, is required to control the Steam Humidifier. The
humidistatmaybe installed on thewall in the livingspace
oron thereturnairduct.NOTE: Continuosfan operation
should be initiated if the humidistat is installed on the
returnairduct!Instructions for installation are packaged
withthehumidistat.
DONOTconnectanyforeignvoltagetothe“H”terminals
of the humidifier. The unit supplies it’s own 24 volt
control voltage. Simply connect the two “H” terminals
straighttothehumidistatterminals.
All wiring must be made in accordance with local codes
and ordinances. DO NOT cut off the grounded plug
and/orhardwirethisunittolinevoltage.
Figures 5 & 6 describes the suggested interlock wiring
arrangement for HVAC systems. Interlocking may be
performed on heating systems that provide a 24 VAC NEC
Classllterminalforblowercontrol.
Theblowerrelay(G)circuitisconnectedtothelowvoltage
terminals on the humidifier, Figure 5. The relay contacts
mustbeusedtointerlockthesystemblower.
If the Steam Humidifier is removed and
disconnected from the system, the blower
interlockcircuitmustberestoredtoit'soriginal
configuration.
Placethehumidifierreservoirintotheopeningintheductand
securewitheight(8)sheetmetalscrews.
NOTE:Iftheductworkwillnotsupporttheunitinalevel
position with the water pan full of water, the duct-work
must be reinforced. Both steam models weigh
approximately 9 Lbs. empty and approximately 15 Lbs.
fullofwater.
Because of the high output of this Humidifier, it must not
be operated in ducts or plenums without the blower
operating. The steam humidifier is designed to be
"Dominant" over the Heating-Air Conditioning System
Blower. The "System" blower will be operated by the
humidifier when humidity is required to meet the
humidistatsetting.
The use of an overflow line and drain line is always
required.
Use 5/8" ID high temperature tubing, such as automotive
heater hose or dishwasher drain hose. Slip the hose over
the 5/8" drain fitting and use a hose clamp to secure. Use
3/8" high temperature tubing for the automatic drain
connection.Slipthe hose over the 3/8"adaptorfitting and
useahoseclamptosecure.
Route the hoses to a suitable drain. DO NOT route the
hoses above the humidifier. Failure to install the drain
lines will result in water leaks during normal operating
conditions.
3
S2000 & S2020 Typical Wiring
and Blower Interlock Diagram
Furnace
S2000 & S2020 Humidifier
Humidistat
G1 R G2 H H
Typical
Thermostat
G YWR
G YWR
FIG. 5 Heat & Cool System

9.SETTINGTHEHUMIDISTAT
ConnectfieldwiringasshowninFigures5or6.
It is recommended that humidistat settings of 30-40% not be
exceeded. If condensation is noticed on windows during
very cold outside temperatures, the humidistat setting should
belowered.
4
RELATIVE HUMIDITY CHART
Outside
Temperature
Outside
Relative
Humidity
Indoor Relative
Humidity
When Outside
Air Is Heated To
72 Degrees F
Maximum Safe
Recommended Indoor
Relative Humidity
-10 Deg. F
10 Deg. F
20 Deg. F
30 Deg. F
0 Deg. F
40%
40%
40%
40%
40%
60%
60%
60%
60%
60%
80%
80%
80%
80%
80%
1%
2%
2%
5%
8%
13%
2%
4%
6%
8%
2%
5%
7%
11%
17%
20%
25%
30%
35%
35%
FIG. 6
Furnace
S2000 & S2020 Humidifier
Humidistat
G1 R G2 H H
Heat only
Thermostat
WR
GWR
Heat Only System
The maximum recommended relative humidity for your
home depends upon factors such as outdoor air temperature,
type and placement of insulation, vapor barriers,
effectiveness of weather stripping, type of windows and
doors(including framesandjambs)andwhether ornotstorm
windows and doors are used. With all these variables it is
nearly impossible to recommend a proper humidity setting.
The best humidistat setting is one that you are comfortable
with. Also, as the outdoor temperature fluctuates, it may be
necessary to adjust the humidity level of your system a few
timesduringtheheatingseason.
Refer to the "Relative Humidity Chart" as a starting point for
your proper humidistat setting. Generally, in a tighter and
better insulated house, the humidistat may be set higher than
inadrafty,un-insulatedhouse.
IMPORTANT: If the humidistat, controlling the
humidifier, is installed on the return air plenum, it must be
located at least three (3) feet upstream from the furnace or
heat pump. If the humidifier is installed in the return air
plenum the humidistat must be located at least three (3) feet
upstreamfromthehumidifier.
The humidistat has two (2) screw terminals which should be
connectedtothelow-voltageinterlockplug.(Figure5).

10.INITIALSTART-UP
11.OPERATINGSEQUENCE
Once the Steam Humidifier has been installed and the
water, humidistat and blower interlock connections
completed,thehumidifiermaybeinitiallystarted.
A.Turn"ON"thewatersupplytothesteamHumidifier.
B.Setthehumidistattoahighor"ON"position.
C. Plug the S2000 Humidifier line cord into a 120
VAC,15ampsource.(240VAC,10ampforS2020).
D. The Green "POWER" LED should slowly blink
and the "FILL" LED should be illuminated. Water
should begin to fill the Water Pan. (If the unit is
equipped with an automatic drain valve, the "POWER"
LED will blink rapidly and the drain valve will open
momentarilyuponinitialstartup).
E. When the water has reached the probe level the
"FILL" lamp and fill valve will be turned off, and the
"HEATER" LED and heater element will be turned
on.
F. Once the water reaches 170 deg. F. the "BLOWER"
LEDwillilluminateandtheblowerwillturnon.
G. If the above steps have been successfully
completed,thehumidifierisoperatingproperly.
A. POWER: In normal standby mode, when the
humidistat is not calling for humidity and the power
cord is plugged in, the "POWER" LED should be
blinking slowly. If the green "POWER" LED is not
flashing, when there is power to the unit, there has been
amalfunctioninthemicroprocessorcircuit.
B. FILL: When the humidistat closes, on a call for
humidity, the "FILL" LED is illuminated, the Solenoid
Valve isopenandthewaterreservoirisfilling.
C. HEATER: When the water reaches it's proper level
the valve closes, the "FILL" LED goes out, the
"HEATER" LED is illuminated, and the Heater begins
toheatthewater.
NOTE: If the humidifier is unplugged while in
operation and then plugged back in, A rapid flashing
of the “POWER” LED will occur and all other
functions will stop! The unit wants to perform a probe
test but cannot perform this test until the water cools
down. Simply wait until the unit cools down and it will
resumenormaloperations.
D.BLOWER: Whenthewater in the reservoir reaches
approximately 170 deg. F. the "BLOWER" LED will
be illuminated and the interlock wiring should turn the
system blower on. Depending upon the water and
ambient temperatures, it may take anywhere from
fourto twelve minutes forthe water to heat to 170 deg.
F. If the humidistat remains closed the "HEATER" and
"BLOWER" LED's will both be illuminated at the same
timeandthe"POWER"LEDwillbeblinkingslowly.
E. The "FILL" LED will illuminate and the water
reservoir will refill at irregular intervals, depending on
the boil off rate. Depending upon the water
temperature, the "BLOWER" LED may remain
illuminated or maygo offwhenthe reservoir isfilling.
The "HEATER" LED should remain illuminated
unless the humidistat opens or the humidifier enters a
draincycleorfailuremode.
F. DRAIN: This LED will be illuminated when
the microprocessor cycles the humidifier into a
Maintenance Mode. This mode will last about one hour
and the microprocessor will automatically restart
the unit afterwards. This will occur once every twelve
hours to let the heater cool-down and contract so that
thermal expansion will shed any deposits that have
built up on the heater. If the unit is equipped with a
drain kit, the reservoir is drained of water and most
loose deposits. The drain valve will then close and the
fill valve will open to refill the reservoir and resume
normal operation. NOTE: The "POWER" LED will
blinkrapidlyduringMaintenancemode.
G. FAILURE LED'S: When service is required,
these LED's will illuminate. If the humidifier enters a
failure mode, it must be manually reset by
disconnecting the powerand then reconnectingit.
WATER: Thiswill occur when the reservoir is not
filling up with water, not filling fast enough or the
microprocessor cannot recognize that the water is
touchingtheprobe.
HEATER: This will occur if the humidifier is not
boilingoffenough waterduringthe "HEATER" cycle.
Water in reservoir is not reaching 170 deg. F.
temperature. Both LED’s will illuminate in this
condition.
THERMISTOR: This will occur if a short or open is
detectedinthetemperatureprobe.
NOTE:A unique featureof the “S”series humidifiers
iscalled“Fillon Request”. Theunitwillnotrefill with
water after a maintenance cycle, unless there is a
demand for humidity from the humidistat. This
ensures that the unit will not sit idle with standing
water,whichcanstagnateovertime.
5

13. SERVICEINDICATORS
Seven LED lamps provided on the front panel indicate the
functionalstatusofthehumidifierasshowninFigure7below.
6
A.
L.
M.
N.
O.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
Unplug the power cord from the 120 volt source for
S2000(240voltforS2020)andallowthewatertocoolfor
atleast30minutespriortoremoval.
Turnoffthewatersupplyatthesaddletappingvalve.
Remove the cable assembly wire plug from the top of the
plasticcontrolhousing.
Drain the water with the manual drain valve. NOTE: The
drain valve will be hot if the humidifier has not been
allowedtocool.
Disconnectthewater and drain lines. NOTE:Somewater
may drain out of the water line. Have a small container
readytocatchthewater.
NOTE: Although the water has been drained, some water
may still remain in the humidifier reservoir along with
sediment. Be careful not to tip the unit over when
removingthescrewsinthefollowingstep.
Remove the eight (8) screws from the front mounting
plate.
Slidethehumidifieroutoftheduct.
Remove the two (2) screws holding the tank baffle to the
pan flange and remove the baffle from the unit. Scrape all
mineral deposits from the baffle and wash baffle off as
described in step J. Remove the Anode from the baffle
plate and scrape it clean for next season, or discard it and
purchase a new one. Operating the unit without the anode
willdegradetheperformanceandincreasemaintenance.
Useaputtyknifetoscrapethemineralsfromthesidesand
bottom of the water reservoir. DO NOT scrape on the
small temperature probe. Use a soft emory cloth if
necessary.
Carefully scrape the Water Level Probe to remove
mineraldeposits.Usesoftemoryclothifnecessary.
Clean the Water Probe Insulator, inside the pan, with a
cloth and 50-50 mixture of water and vinegar, rinse with
freshwater.Inspectforanymineraldepositsontheplastic
insulator. Repeat cleaning if necessary and thoroughly
dry.Useasmallnonferrousbrushtocleandepositsoffthe
heater element and thermistor probe. Be careful not to
damageanyofthecomponents.
Rinseoutthe reservoir. Becarefulto keep water offof the
wiringcompartmentortheoutsideofthehumidifier.
Reinstallthetankbaffleandtightenthetwo(2)screws.
Re-installtheunit intheduct and connectthewater line,the
drainlinesandthecableplug.Storetheunitinthiscondition
forthesummer,orcontinuetothenextstep.
Turn on the water supply. Inspect the water con-nections
anddrainfittingsforleaks.
Plug-inthe S2000powercordtothe120VAC (240VACfor
S2020)groundedoutlet.DONOTuseanextensioncord.
a.ThegreenPOWERlightshouldblinkslowly.
b.Ifthehumidistatiscallingforhumiditythewater
valvewillenergizeand thewaterpanwillbegin
to fill.
Maintenance and inspection of the unit requires removal of
the humidifier from the duct. This can be done following
thesesteps.
12.MAINTENANCE/SPRINGSHUTDOWN
Proper maintenance and removal of mineral deposits is still
required on your steam humidifier in order to optimize
performance. Annual cleaning is a must and more frequent
cleaning may be necessary depending on the mineral content
ofthewaterinyourarea.
A post winter cleaning and shutdown, will prevent hard
deposits from accumulating inside the bin, while the
humidifierisidle over thesummer. Do notallowthe unit tosit
idle for long periods without a proper draining, cleaning, and
shutdown.Failuretodoso,willaffecttheperformanceofyour
steamhumidifier.
FIG. 7
LED LIGHT EXPLANATION
IMPORTANT NOTE
POWER - GREEN - BLINKING SLOWLY-IF POWER TO UNIT
SERVICE THERMISTOR - RED - ON STEADY
SERVICE HEATER -RED - ON STEADY BOTH LED'S
SERVICE WATER - RED - ON STEADY
BLOWER - AMBER - ON STEADY WHILE PAN ABOVE 170 DEG F.
HEATER - AMBER - ON STEADY WHILE HEATING (BOILING)
FILL - AMBER - ON STEADY WHILE FILLING PAN
DRAIN - AMBER - ON STEADY WHILE DRAINING PAN
ON THE INITIAL FILL AFTER INSTALLATION OR ANY TIME THE WATER PAN IS DRAINED THE PAN
MUSTFILLWITHABOUTTHREE (3) TIMESTHE AMOUNT OFWATERAS REQUIRED INTHE NORMAL
CYCLE OF FILLING. THE 'FILL TIMER' MAY TIME OUT BEFORE THE WATER LEVEL REACHES THE
WATER LEVEL PROBE CAUSING THE 'SERVICE CYCLE' TO BE STARTED. IF THE WATER FAILURE
ILLUMINATES, UNPLUG THE UNIT FROM ITS POWER SOURCE, WAIT ABOUT 15 SECONDS AND
RECONNECT THE POWER SOURCE. THE SERVICE LIGHT WILL GO OUT AND THE UNIT WILL
CONTINUEFILLINGTO THE CORRECTLEVEL.

7
A.
G.
B.
C.
D.
E.
F.
Thegreen"Power"lightdoesnotblinkoffandon.
1.TheS2000 isnotconnectedtoanactive120
VAC15Amppowersource. (S2020,240VAC,
10AMP).
2. CalltheTechnicalSupportHotline.
The "HEATER"LED doesnotilluminate.
1. The humidistat is not closed, calling for humidity or the
humidistatiswiredincorrectly.
2.Theunitisinthemaintenancecycle.
The HVAC Blower will not operate, but the "Blower"
LEDison.
1. The blower "Field" wiring and/or interlock circuitry is
incorrect.
2.TheHVACelectricpowerisdisconnected.
3.The humidifier internal "Blower" relay is defective. Call
theTechnicalSupportHotline.
4.TheHVACBlowermotorhasfailed.
The HVAC Blower will not operate and the "Blower"
LEDisnoton.
1.Thewaterpantemperaturehasnotreachedahighenough
temperature to activate the "Blower" relay, about 170
degrees Fahrenheit. This takes several minutes after the
"HEATER" LED is illuminated. Depending on the water
temperature and the surrounding condition, this may take
up to 12 minutes. If the problem continues, the heater
elementmaybe defective,thethermistortemperatureprobe
maybedefective.ContacttheTechnicalSupportHotline.
RedServiceLight(error#1)isonconstantly.
THERMISTOR...Thisis an indicationthatthe temperature
probe is open or shorted to ground. May also indicate the
probe has detected a pan temperature in excess of 230
degrees, resulting in a total shutdown. Call Technical
Support.
RedServiceLight(error#2)isonconstantly.
WATER ...This is an indication that the water fill time has
been exceeded. The water level did not reach the probe tip
in the given amount of time. It may also indicate an
unsuccessfuldraincycle.
1.Thewaterlineisshutoffatthesaddlevalve.
2.Thewaterlineiscrimpedorpinched.
3.Thewatervalveinletscreenisplugged.
Remove the waterlinefromtheunitandcheckthe
screenfoundinsidetheinletsideofthevalve.
4.Thewatervalvemaybe defectiveandmust
bereplaced-seereplacementparts.
5.Thedrainvalveisunpluggedordefective.
6.Debrisiscloggingthedrainvalveordrainline.
7.CalltheTechnicalSupportHotline.
BothRedServiceLights(error#3)areon.
HEATER FAILURE...This is an indication that the water
temperature is not increasing or reaching the boiling
point.
1.Faultyheaterelementorfaultywireconnection.
2.Theunit hasdetected awater pantemperaturein excess
of 230 degrees Fahrenheit, and has shut down all the
humidifieroperations.
3. This can happen if the unit is operated without water
in the pan as a result of a water level probe malfunction,
due to lack of maintenance. The pan boils dry and over-
heats the water pan. If this condition occurs, call the
TechnicalSupportHotline.
4. The unit has operated for 45 minutes without a request
for water, due to a leaking water fill valve, which is filling
thetankcontinuously.
Ifthehumidifierseemstooperateinarandommanner
that doesn't seem to fit any of the pre-described
conditions,checkthefollowing:
1. Check to make sure that the wires used to connect the
humidifier to the humidistat are separate wires and not
part of a multi-wire bundle used to hook up the furnace
thermostat or any other device. The associated close
wires may create an induced voltage in the humidistat
wiring.
2. Make sure that the water level probe and plastic
insulator are clean and free of mineral build-up. It may
become electrically conductive to ground, sensing a false
indicationthatthewaterleveliscorrect.
3.If theelectricsolenoidvalvemakesaloud noisewhen it
closes,installanoptionalwaterhammerarrester toabsorb
the spike. Frequent or erratic water fill cycles can be due
toairturbulence,whenmountedinthesupplyairplenum.
4. The water probe uses the natural conductivity of the
water,todetermine the proper water levelin the reservoir.
Water that has been de-mineralized or over treated may
not allow the unit to function properly. Add
approximately 1-2 tablespoon of salt to the tank, to
remedythisproblem.
5. These steam humidifiers must be connected to
dedicatedoutletsofthepropercurrentandvoltageratings.
Theuseofextensioncordsisnotrecommended.DONOT
cutoffthegroundedplugand/orhardwirethishumidifier
tolinevoltage.Thiswillvoidthewarranty.
H.
SERVICE INDICATORS

R
C
EW
CONTROLS INC.
385 Highway 33 Englishtown, NJ 07726
Tel. (800) 446-3110 Fax:(800) 635-8646
14. SERVICE AND REPLACEMENT PARTS ITEM
1 120 VOLTHEATER ASSEMBLY
240 VOLTHEATER ASSEMBLY
24 VOLT SOLENOID VALVE ASSEMBLY
WATER LEVEL PROBE ASSEMBLY
THERMISTOR PROBE ASSEMBLY
CIRCUIT BOARD ASSEMBLY
DRAIN VALVE ASSEMBLY
TANK BAFFLE
WATERHAMMERARRESTER(notshown)
ZINC ANODE
INSULATION KIT (not shown)
2002
2003
2007
2008
WH 100 WH 100
Z 100 Z 100
2004
2006
2120
2001
2240
2002
2008
2005
2006
2003
2007
2001
1
2
3
4
5
6
7
8
9
10
DESCRIPTION OF PART
S2000 S2020
PART NO. PART NO.
107
3
2
4
235
6
1
3
4
1
8
P/N 094021A0099

AUTOFLO HUMIDIFIERS
Automatic Drain Assembly
Parts List:
* 24 volt solenoid drain valve
* 1/4" x 7/8" brass nipple
* 1/4" x 3/8" barb brass 90* adaptor
* 1/4"m x 1/4"f x 1/4"f brass street "T" fitting
INSTALLATION INSTRUCTIONS & OWNER'S MANUAL
AUTOMATIC DRAIN ASSEMBLY
SUPPLEMENT TO THE AUTOFLO ELECTRONIC STEAM
POWER HUMIDIFIERS MODEL # S2000 AND S2020
INSTALLATION:
1. Unplug the power cord from the 120 volt source for the S2000. (240 volt for the S2020).
2. Allow the water in the pan to cool for at least 30 minutes.
3. Open the manual drain valve and drain the water bin completely. Have a container ready to
catch the water. CAUTION: The water may still be hot!
4. Unscrew and remove the manual drain valve when the bin is empty.
5. Apply teflon tape to the threads of the manual drain valve and install into the bottom of the "T" fitting.
6. Apply teflon tape to the male threads of the "T" fitting. Screw and tighten into the drain connection
where the manual drain valve was removed.
7. Apply teflon tape to the threads of the short (1/4"x7/8") brass nipple.
8. Screw and tighten the brass nipple into the "T" fitting.
9. Screw and tighten the short nipple onto the solenoid valve, and then screw and tighten the assembly
onto the brass street "T" fitting. IMPORTANT: Observe the direction of flow on the solenoid valve.
10. Apply teflon tape to the threads of the brass elbow adaptor.
11. Screw the elbow adaptor into the solenoid valve, and tighten to a position with the barb fitting
pointing down. NOTE: Do not use the top of the solenoid valve as leverage when making connections.
12. Connect 3/8" I.D. high temperature rubber or plastic tubing, to the barb fitting and use a hose
clamp to secure it.
13. Route the drain tubing to a suitable drain. Do not route the tubing above the humidifier!
14. Insert the solenoid wire plug, into the molex connector on the side of the steam humidifier.
15. Plug in the power cord and set the humidistat to call for humidity.
16. The drain valve will open momentarily, the water fill valve will open, and the bin will fill with water.
17. Inspect for leaks and repair as necessary.
OPERATION:
18. The humidifier will resume normal operation.
19. The control panel will automatically detect the presence of the new drain valve.
20. The control panel will initiate a drain and flush cycle every 12 hours.
21. This will reduce the amount of mineral build up inside the water bin, and extend the life
of the heater element and optimize performance.
22. The automatic drain kit does not take the place of routine manual cleaning,
preventive maintenance and storage shutdown.
23. A properly installed drain kit, and regular preventive maintenance and cleaning, will keep your
power steam humidifier working for many years.
24. Contact the Autoflo technical support line if you have any questions or need assistance.
Required tools and materials:
* Adjustable wrenches
* Drain bucket
* 3/8" high temperature hose.
* Hose clamp
* Teflon tape
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 800-635-8646 E-Mail- [email protected]
9

R
C
EW
CONTROLS INC.
385 Highway 33 Englishtown, NJ 07726
Tel. (800) 446-3110 Fax: (800) 635-8646 Tech. (800) 526-4048
FIG. 8
DRAIN COCK VALVE
P/N 094020A0055
"T" ADAPTER, 1/4" NPT
P/N 094021A0038
NIPPLE (CLOSE), 1/4" NPT X 7/8"
P/N 094021A0039
SOLENOID VALVE, 24/60 VAC
P/N 094021A0040
ELBOW FITTING,
1/4" NPT X 3/8" BARB
P/N 094021A0036
JUMPER WIRE,
20GA. X 1.50" LONG
MOLEX PLUG
P/N 205113A0098
BLACK WIRES
18GA. X 18" LONG
P/N 501052A0002
10

AUTOFLO HUMIDIFIER
Z100 ASSEMBLY
INSTALLATION INSTRUCTIONS & OWNER'S MANUAL
Z100 REPLACEMENT INSTRUCTIONS
SUPPLEMENT TO THE AUTOFLO ELECTRONIC STEAM POWER HUMIDIFIERS
MODEL # S2000 AND S2020
APPLICATION NOTE
AN 131
The AUTOFLO steam humidifier now comes equipped with a factory installed Z100, which acts as a
sacrificial metal. Put simply, the chemicals in the water will attack and cling to the . The chemicals
will not attack the other components inside the humidifier as long as the s present and active.
This results in a dramatic decrease in chemical and scale build up on the stainless steel components
inside the tank. In particular, it means less scale build up on the heating element which is subject to
damage from excessive scaling and over heating. This also means that efficiency stays high and
preventive maintenance is and .
The is positioned on the baffle plate inside the tank and is easily removed and replaced.
Remember that the ’s job is to become the target of chemical attack, so it will be heavily covered
with scale and should be replaced annually for best results.
To remove the you must have already unplugged and shutdown your steam humidifier and
allowed it to cool. The water tank has been drained, the water supply, drain lines and electrical wiring
have been disconnected and the unit has been removed from the duct.
Using a phillips screwdriver, remove the two screws that hold the
baffle plate to the tank. Lift the baffle slightly back to clear the water probe and then straight up and
out of the tank. You can then see the round , or rather what is left of it after a single season.
Notice the heavy scale build up on the that would have been on your element, if the was
not there. Use a rag or pliers to grasp the edges of the and simply unscrew it from the baffle
plate. Rinse off or wipe away any residual scale from the baffle plate and install the new . Leave
a slight gap between the bottom of the and the baffle plate. Now re-insert the baffle plate into
the tank and secure with the two screws that were removed previously. It’s that simple.
The can also benefit the older model steam humidifiers. Simply lay the down into the baffle
plate in the same location as the factory installed model. DO NOT lay the down into the main
tank. It may come in contact with the heating element and damage it. The dimensions of the baffle
plate prevent the from falling down into the tank.
The Z100 is just the latest innovation in the AUTOFLO Steam Humidifier line as we continue in our pursuit
of Excellence Without Compromise.
Z100
Z100 i
faster easier
Z100 Z100
Z100
Refer to the blow up view on Page 8.
Z100
Z100 Z100
Z100 Z100
Z100
Z100 Z100
Z100
Z100
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-635-8646 E-Mail- [email protected]
11
P/N 094021A0099 Rev. B
Other manuals for S2000
1
This manual suits for next models
1
Table of contents
Other AutoFlo Humidifier manuals
Popular Humidifier manuals by other brands

Condair
Condair GS series Installation and operation manual

Scarlett
Scarlett SC-AH986E16 instruction manual

pureguardian
pureguardian H1510 Use & care instructions

Devatec
Devatec ElectroVap MC Series manual

Hamilton Beach
Hamilton Beach True Air 04700 user manual

Black & Decker
Black & Decker HM6000-B5 manual