In the screensaver, it will switch to DMX mode in response to the channel sent from the
console whenever the master or slave receives the DMX512 signal.
4. Manual Control
Select the Manual Control menu, Press the UP/DOWN button to select which function
to operate. The right number after pressing the SET button is selected. Then press the
UP/DOWN button to modify the value, long press to continuously modify, and press the
SET button to change the options on the left. Press the MODE button to exit and return
to the main menu. It will not exit the manual mode in this state. It’s need to enter other
modes for switching. For example, if you set the DMX address, then will enter the DMX
mode.
5. Settings
1) Curve Select
To choose one of linear dimming/square curve dimming/inverse square curve
dimming/S-curve dimming. The characteristic of linear dimming is that the light output
brightness maintains a linear relationship with the channel value; square curve dimming
is relatively linear dimming, and the channel value range occupied in the low brightness
area is more, that is the low brightness area is more abundantly adjusted; the low
brightness area occupies few channels. When the channel value increases from 0 to up,
the brightness quickly becomes very bright, and it allocates more channel value ranges
in the high brightness area; the S-shaped curve is in the low brightness area Both the
high-brightness area and the high-brightness area are allocated, and the medium-
brightness area is few.
2) DMX Fail
“OFF” (No DMX, lighting is off.), “HOLD” (No DMX, lighting keeps the original state).
3) Display
The display reverse is used when the fixture is upside down.
4) Key Lock
When using the key lock function, not key operation after 30 seconds, the key is locked.
Pressing the key in the locked state is invalid. It needs to press the MODE+SET key
combination for 3 seconds to unlock.
5) Back Light
Select always on or 60S off if no operation
6) Reset
In order to verify whether the motor is working normally, and whether to save it after
modifying the parameters, it can be perform a reset operation, like re-powering on.
7) Default