Connections
1. Mains voltage, 230 VAC
2. Fuse 230 VAC side
3. Alarm output, indicates mains voltage interruption
4. Battery connection, note
+
and
-
5. Battery fuse
6. 48 VDC output
7. Connectors with supply voltage for AX-Power Plus Switch Kit
8. Operating mode switch, must be in "Standard" mode.
9. RJ-45 ports without PoE (Ports 1-2)
10. RJ-45 ports with PoE (Ports 3-6)
11. Expansion space for AX-Power Plus Switch Kit.
12. The AX-Power Switch Kit is mounted in a free compartment
Installation of Switch Kit AX-Power Plus
The AX-Power 4 Plus can be expanded with one or two Switch Kit AX-Power Plus to eight and
twelve PoE ports, respectively.
1. Disconnect the 230 VAC supply to the unit
2. Bend the plate down into the relevant compartment and mount the angle. (12 in the section
connections)
3. Connect the cable to the back of the switch and to the DC socket on the connection board.
(7 in the section connections)
4. Push the switch into the slot and lock with the flaps on the front.
5. Connect the patch cable from the link socket (9 in the connections section) on the new
3 (4) ManualAX-Power 4 Plus