Axiometrix Solutions imc MTP-NT User manual

imcTest & Measurement GmbH • Voltastr.5 • 13355Berlin • Germany
© 2023 imcTest & Measurement GmbH
imc MTP-NT
Manual
Edition 2 - 2023-11-09

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 2
Disclaimer of liability
The contents of this documentation have been carefully checked for consistency with the hardware and
software systems described. Nevertheless, it is impossible to completely rule out inconsistencies, so that we
decline to offer any guarantee of total conformity.
We reserve the right to make technical modifications of the systems.
Copyright
© 2023 imcTest & Measurement GmbH, Germany
This documentation is the intellectual property of imcTest & Measurement GmbH. imcTest & Measurement
GmbH reserves all rights to this documentation. The applicable provisions are stipulated in the "imc Software
License Agreement".
The software described in this document may only be used in accordance with the provisions of the "imc
Software License Agreement".
Open Source Software Licenses
Some components of imc products use software which is licensed under the GNU General Public License (GPL).
Details are available in the About dialog.
A list of the open source software licenses for the imc measurement devices is located on the
imcSTUDIO/imcWAVE/imcSTUDIO Monitor installation medium in the folder "Products\imc DEVICES\OSS" or
"Products\imc DEVICEcore\OSS" or "Products\imc STUDIO\OSS". If you wish to receive a copy of the GPL sources
used, please contact our Hotline.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 3
Notes regarding this document
This document provides important notes on using the device / the module. Safe working is conditional on
compliance with all safety measures and instructions provided. The manual is to be used as a kind of reference
book. You can skip the description of the modules you do not have.
Additionally, all accident prevention and general safety regulations pertinent to the location at which the device
is used must be adhered to.
These instructions exclusively describe the device, not how to operate it by means of the software!
If you have any questions as to whether you can set up the device / module in the intended environment, please
contact the imc hotline. The measurement system has been designed, manufactured and unit-tested with all due
care and in accordance with the safety regulations before delivery and has left the factory in perfect condition. In
order to maintain this condition and to ensure safe operation, the user must observe the notes and warnings
contained in this chapter and in the specific sections applicable to the concrete device. Never use the device
outside the specification.
This will protect you and prevent damage to the device.
Special notes
Warning
Warnings contain information that must be
observed to protect the user from harm or to
prevent damage to property.
Note
Notes denote useful additional information on a
particular topic.
Reference
A reference in this document is a reference in
the text to another text passage.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 4
Table of contents
Table of contents
1 General Notes ........................................................................................................... 6
1.1 imc Customer Support / Hotline .................................................................................................... 6
1.2 Legal notices ................................................................................................................................... 6
1.3 Explanation of symbols .................................................................................................................. 9
1.4 Document history ......................................................................................................................... 10
1.5 After unpacking ............................................................................................................................ 10
2 Safety ...................................................................................................................... 11
3 Start of operation .................................................................................................... 14
3.1 NT module firmware .................................................................................................................... 14
3.2 NT configuration software ........................................................................................................... 15
4 MTP-NT description ................................................................................................. 16
4.1 MTP-NT modules .......................................................................................................................... 16
4.2 Signal bandwidth and sampling rates .......................................................................................... 24
4.3 Connection cables ........................................................................................................................ 24
4.4 MTP-NT Bus connection ............................................................................................................... 27
4.5 Block diagram ............................................................................................................................... 30
4.6 Settings of parameters of MTP-NT-Controller ............................................................................. 32
4.7 Wireless solutions ........................................................................................................................ 33
4.8 Daisy-chain connection (bus cable) ............................................................................................. 35
5 Decoder ................................................................................................................... 36
5.1 Analog Decoder: MTP-NT-DEC8CH/16CH, 24CH, 32CH ............................................................... 36
5.2 Digital Decoder: MTP-NT-DIG-DEC-V2 ......................................................................................... 38
6 Measurement types ................................................................................................ 41
6.1 MTP-NT-STG2 - measuring bridges .............................................................................................. 41
6.2 MTP-NT-ANALOG2 ....................................................................................................................... 44
6.3 MTP-NT-IEPE2 connection options for sensors ........................................................................... 45
6.4 MTP-NT-VOLT2 - mesauring voltages .......................................................................................... 46
6.5 MTP-NT-POT2 ............................................................................................................................... 47
6.6 MTP-NT-XVDT2 ............................................................................................................................. 48
6.7 MTP-NT-THERMO2 ....................................................................................................................... 49
6.8 MTP-NT-CON-IND-Tx (controller connection) ............................................................................. 51
6.9 MTP-NT IND PWR 6V (power module connection) ..................................................................... 52
7 MTP-NT mounting ................................................................................................... 53
7.1 Mounting of second pick up at flat coil on shaft ......................................................................... 53
7.2 Mounting of second pick up at coil ring ....................................................................................... 54
8 Radio transmission .................................................................................................. 55
8.1 Decoder/Receiver box (radio transmission version) ................................................................... 55
8.2 HF-Tx - Radio transmitter incl. antenna (rotor side) .................................................................... 56
8.3 Installation of the radio transmitter on a shaft ........................................................................... 57
8.4 Position of receiving standard magnetic foot antennas .............................................................. 58

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 5
Table of contents
9 Inductive transmission ............................................................................................ 59
9.1 Inductive Pick-up head ................................................................................................................. 60
9.2 IND-PICKUP-HEAD 45 MHz ........................................................................................................... 61
9.3 Inductive powering ....................................................................................................................... 65
Index .......................................................................................................................... 91

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 6
imc Customer Support / Hotline Chapter 1
1 General Notes
1.1 imc Customer Support / Hotline
If you have problems or questions, please contact our Customer Support/Hotline:
imcTest & Measurement GmbH
Hotline
(Germany):
+49 30 467090-26
E-Mail:
hotline@imc-tm.de
Internet:
https://www.imc-tm.com
International partners
For our international partners see https://www.imc-tm.com/imc-worldwide/.
Tip for ensuring quick processing of your questions:
If you contact us you would help us, if you know the serial number of your devices and the version info of the
software. This documentation should also be on hand.
·
The device's serial number appears on the nameplate.
·
The program version designation is available in the About-Dialog.
1.2 Legal notices
Quality Management
imcTest & Measurement GmbH holds DINENISO9001 certification since May
1995 and DINENISO14001 certification since November2023. You can download
the CE Certification, current certificates and information about the imc quality
system on our website:
https://www.imc-tm.com/quality-assurance/.
imc Warranty
Subject to the general terms and conditions of imcTest & Measurement GmbH.
Liability restrictions
All specifications and notes in this document are subject to applicable standards and regulations, and reflect the
state of the art well as accumulated years of knowledge and experience. The contents of this document have
been carefully checked for consistency with the hardware and the software systems described. Nevertheless, it
is impossible to completely rule out inconsistencies, so that we decline to offer any guarantee of total
conformity. We reserve the right to make technical modifications of the systems.
The manufacturer declines any liability for damage arising from:
·
failure to comply with the provided documentation,
·
inappropriate use of the equipment.
Please note that all properties described refer to a closed measurement system and not to its individual slices.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 7
Legal notices Chapter 1
Guarantee
Each device is subjected to a 24-hour "burn-in" before leaving imc. This procedure is capable of detecting almost
all cases of early failure. This does not, however, guarantee that a component will not fail after longer operation.
Therefore, all imc devices are granted liability for a period of two years. The condition for this guarantee is that
no alterations or modifications have been made to the device by the customer.
Unauthorized intervention in the device renders the guarantee null and void.
Notes on radio interference suppression
The imc MTP-NT telemetry system satisfy the EMC requirements for an use in industrial settings.
Any additional products connected to the product must satisfy the EMC requirements as specified by the
responsible authority (within Europe1) in Germany the BNetzA - "Bundesnetzagentur" (formerly BMPT-Vfg. No.
1046/84 or No. 243/91) or EC Guidelines 2014/30/EU. All products which satisfy these requirements must be
appropriately marked by the manufacturer or display the CE certification marking.
Products not satisfying these requirements may only be used with special approval of the regulating body in the
country where operated.
All lines connected to the MTP-NT telemetry system should not be longer than 30m and they should be shielded
and the shielding must be grounded.
Note
The EMC tests were carried out using shielded and grounded input and output cables with the exception of
the power cord. Observe this condition when designing your setup to ensure high interference immunity
and low jamming.
1 If you are located outside Europe, please refer the appropriate EMC standards used in the country of operation.
Cables and leads
In order to comply with the value limits applicable to Class B devices according to part 15 of the FCC regulations,
all signal leads connected to the MTP-NT telemetry system must be shielded.
Unless otherwise indicated, no connection leads may be long leads (<30m) as defined by the standard IEC
61326-1. LAN-cables (RJ 45) and CAN-Buscables (DSUB-9) are excepted from this rule.
Only cables with suitable properties for the task (e.g. isolation for protection against electric shock) may be
used.
ElektroG, RoHS, WEEE, CE
The imcTest & Measurement GmbH is registered with the authority as follows:
WEEE Reg. No. DE 43368136
valid from 24.11.2005
Reference
https://www.imc-tm.com/elekrog-rohs-weee/ and https://www.imc-tm.com/ce-conformity/

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 8
Legal notices Chapter 1
FCC-Notice
This product has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment
on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
·
Reorient or relocate the receiving antenna.
·
Increase the separation between the equipment and the receiver.
·
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
·
Consult our imc Hotline or an experienced technician for help.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this product that are not
expressly approved by imc may void the user's authority to operate this equipment.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 9
Explanation of symbols Chapter 1
1.3 Explanation of symbols
CE Conformity
see CE chapter 1.2
No household waste
Please do not dispose of the electrical/electronic device with household waste, but at the
appropriate collection points for electrical waste, see also chapter 1.2 .
Potential compensation
Connection for potential compensation
Grounding
Connection for grounding (general, without protective function)
Protective connection
Connection for the protective conductor or grounding with protective function
Attention! General danger zone!
This symbol indicates a dangerous situation;
Since there is insufficient space for indicating the rated quantity at the measuring inputs,
refer to this manual for the rated quantities of the measuring inputs before operation.
Attention! Injuries from hot surfaces!
Surfaces whose temperatures can exceed the limits under certain circumstances are
denoted by the symbol shown at left.
ESD-sensitive components (device/connector)
When handling unprotected circuit boards, take suitable measures to protect against ESD
(e.g. insert/remove ACC/CANFT-RESET).
Possibility of electric shock
The warning generally refers to high measurement voltages or signals at high potentials and
is located on devices suitable for such measurements. The device itself does not generate
dangerous voltages.
DC, Direct Current
Supply of the device via a DC voltage source (in the specified voltage range)
6
6

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 10
Explanation of symbols Chapter 1
RoHS of the PR China
The limits for hazardous substances in electrical/electronic equipment applicable in the PRC
are identical to those in the EU. The restrictions are complied with (see chapter 1.2 ). A
corresponding "China-RoHS" label is omitted for formal/economic reasons. Instead, the
number in the symbol indicates the number of years in which no hazardous substances are
released. (This is guaranteed by the absence of named substances).
Labeling integrated energy sources
UxxRxx are integrated in the symbolism. "U" stands for the installed UPS energy sources,
if0=notinstalled. "R" stands for the installed RTC energy sources, if0=not installed. You
can download the corresponding data sheets from the imc website:
https://www.imc-tm.com/about-imc/quality-assurance/transport-instructions/
Observe the documentation
Read the documentation before starting work and/or operating.
On/Off
On/Off button (no complete disconnection from the power supply)
1.4 Document history
Additions and bug-fixes in Edition 2
Chapter
Inductive powering
Updated description and pin configuration, currently available in a separate document.
The content of this separate document "Initial operation for inductive powering" will be
included in the next Edition of this manual.
1.5 After unpacking
Check the delivered system immediately upon receiving it for completeness and for possible transport damage.
In case of damage visible from outside, proceed as follows:
·
Do not accept the delivery or only accept it with reservations
·
Note the extent of the damage on the packing documents or on the delivery service's packing list.
·
Begin the claims process.
Please check the device for mechanical damage and/ or loose parts after unpacking it. The supplier must be
notified immediately of any transportation damage. Do not operate a damaged device.
6

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 11
Chapter 2
2 Safety
This section provides an overview of all important aspects of protection of the users for reliable and trouble-free
operation. Failure to comply with the instructions and protection notes provided here can result in serious
danger.
Responsibility of the operator
The MTP-NT telemetry system is for use in commercial applications. The user is therefore obligated to comply
with legal regulations for work safety.
Along with the work safety procedures described in this document, the user must also conform to regulations
for safety, accident prevention and environmental protection which apply to the work site. If the product is not
used in a manner specified by the manufacturer, the protection supported by the product may be impaired.
The user must also ensure that any personnel assisting in the use of the MTP-NT telemetry system have also
read and understood the content of this document.
Operating personnel
This document identifies the following qualifications for various fields of activity:
·
Users of measurement engineering: Fundamentals of measurement engineering. Basic knowledge of electrical
engineering is recommended. Familiarity with computers and the Microsoft Windows operating system. Users
must not open or structurally modify the measurement device.
·
Qualified personnel are able, due to training in the field and to possession of skills, experience and familiarity
with the relevant regulations, to perform work assigned while independently recognizing any hazards.
Warning
·
Danger of injury due to inadequate qualifications!
·
Improper handling may lead to serious damage to personnel and property. When in doubt, consult
qualified personnel.
·
Work which may only be performed by trained imc personnel may not be performed by the user. Any
exceptions are subject to prior consultation with the manufacturer and are conditional on having
obtained corresponding training.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 12
Chapter 2
Special hazards
This segment states what residual dangers have been identified by the hazard analysis. Observe the safety notes
listed here and the warnings appearing in subsequent chapters of this manual in order to reduce health risks and
to avoid dangerous situations. Existing ventilation slits on the sides of the device must be kept free to prevent
heat accumulation inside the device. Please operate the device only in the intended position of use if so
specified.
Danger
Lethal danger from electric current!
·
Contact with conducting parts is associated with immediate lethal danger.
·
Damage to the insulation or to individual components can be lethally dangerous.
Therefore:
·
In case of damage to the insulation, immediately cut off the power supply and have repair
performed.
·
Work on the electrical equipment must be performed exclusively by expert electricians.
·
During all work performed on the electrical equipment, it must be deactivated and tested for
static potential.
Injuries from hot surfaces!
·
Devices from imc are designed so that their surface temperatures do not exceed limits
stipulated in EN 61010-1 under normal conditions.
Therefore:
·
Surfaces whose temperature can exceed the limits under circumstances are denoted by the
symbol shown at left.
Industrial safety
We certify that the MTP-NT telemetry system in all product configuration options corresponding to this
documentation conforms to the directives in the accident prevention regulations in "Electric Installations and
Industrial Equipment" (DGUV Regulation 3)*. This confirmation applies exclusively to the MTP-NT telemetry
system, but not to all other components included in the scope of delivery.
This certification has the sole purpose of releasing imc from the obligation to have the electrical equipment
tested prior to first use (§ 5 Sec. 1, 4 of DGUV Regulation3). This does not affect guarantee and liability
regulations of the civil code.
*
previously BGV A3.

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 13
Chapter 2
Magnetic radiation
·
The MTP-NT telemetry system should only be applied by qualified personnel.
·
The telemetry system (see chap. "Inductive transmission" ) emits strong magnetic radiation at 30-60kHz to
a distance of 20cm. Therefore, persons with cardiac pacemakers should not work with this telemetry system.
·
Magnetic data storage media should be kept in a distance of at least 3m from the power head to avoid data
loss. The same is valid for electromagnetic sensitive parts, devices and systems.
·
Do not place the telemetry system in the switched-on state near metallic objects, because this results in eddy
currents, which could overload the device and strongly heat up small objects. In addition, the probe could be
destroyed.
·
No metallic objects should be located in the air gap of the telemetry system. The same applies to metallic
parts within a radius of up to 15 to 20mm in all directions.
·
Never touch the rotating shaft itself or rotor electronic contacts during operation.
Observe notes and warnings
Devices from imc have been carefully designed, assembled and routinely tested in accordance with the safety
regulations specified in the included certificate of conformity and has left imc in perfect operating condition. To
maintain this condition and to ensure continued danger-free operation, the user should pay particular attention
to the remarks and warnings made in this chapter. In this way, you protect yourself and prevent the device from
being damaged.
Read this document before turning on the device for the first time carefully.
Warning
Before touching the device sockets and the lines connected to them, make sure static electricity is diverted
to ground. Damage arising from electrostatic discharge is not covered by the warranty.
61

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 14
NT module firmware Chapter 3
3 Start of operation
3.1 NT module firmware
Please download the firmware setup file nt_update.exe from the imc web page:
https://www.imc-tm.com/download-center/product-downloads/mtp-nt/software/
MTP-NT firmware for all MTP-NT systems
All MTP-NT modules are supported by the same firmware. Therefore, with one single operation a complete
MTP-NT system can be updated to the latest firmware version.
To change the COM port click on the COM
port settings box that is located on the top
left corner (marked in red).
In the COM port settings window you can
change the COM port number. The default
communication setting for all MTP-NT
systems is displayed in the Screenshot:
115200,E,8,1.
Note
This setting never has to be changed,
but you must be sure that this setting is
correct. In case of connection problems,
you should check the Device Manager
to see if the COM port used is available.
16

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 15
NT configuration software Chapter 3
3.2 NT configuration software
Please download the configuration software file ntconfiginstaller.exe from the imc web page:
https://www.imc-tm.com/download-center/product-downloads/mtp-nt/software/
Reference
Please find a detailed description of the configuration software in the chapter: "TBD".

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 16
Chapter 4
4 MTP-NT description
The MTP-NT telemetry is a miniaturized measurement system suitable for sophisticated industrial measurement
tasks and rotating applications. Each 2-channel sensor module is equipped with signal conditioning, anti-aliasing
filters, analog-to-digital converters (16 bit) and a digital communication bus connection. All these up to 128
modules (=256 channels) will be controlled by the MTP-NT-Controller module via a daisy-chain system bus
(extendable to several meters). By this concept it's possible to install the acquisition modules close to the sensor
to have short connections for the analog sensor lines. This avoids undesired interferences in noisy environments.
The MTP-NT Controller outputs a PCM bit stream signal in NRZ format with data rates up to 5000kbit/s. The
inductive transmitter module transfers the signal over distances of up to 50 mm and the radio transmitter is able
to cover ranges of 10 m, depends of application.
4.1 MTP-NT modules
MTP-NT-STG2
Acquisition module for 2
strain gauges
MTP-NT-XVDT2
Acquisition module for 2x
LVDT/RVDT sensors
Ø
Full or half bridge (≥120 Ω)
Ø
Quarter bridge (120 Ω or 350 Ω)
Ø
Fixed excitation 4 V DC
Ø
Offset compensation by auto zero
Ø
Manual offset shifting after auto zero
Ø
Signal bandwidth, see chap. signal bandwidth
Ø
ADC Resolution 18 bit
imc article no.: 13220263, order code: MTP-NT-STG2-SET
Set includes: acquisition module (standard housing: standard
temperature range: -40°C to +85°C), sensor cable 500mm
with open end (2x 4-pin), bus cable for MTP-NT modules
length 120mm
Ø
Excitation voltage 4.096 Vpp
(rounded rectangle)
Ø
Excitation frequency 8 kHz
(adjustable via software)
Ø
Sensor impedance ≥ 100 Ω (@ 8 kHz)
Ø
Signal bandwidth, see chap. signal bandwidth
imc article no.: 13220170, order code: MTP-NT-XVDT2-SET
Set includes: acquisition module (standard housing: standard
temperature range: -40°C to +85°C), sensor cable 500mm
with open end (2x 4-pin), bus cable for MTP-NT modules
length 120mm
MTP-NT-VOLT2
Acquisition module for 2x high
level voltage inputs
MTP-NT-IEPE2
Acquisition module for 2
IEPE/ICP® sensors
Ø
Input ranges ±10 to ±0.08 V
Ø
4 V sensor excitation max. 20 mA
Ø
Signal bandwidth, see chap. signal bandwidth
Ø
ADC Resolution 18 bit
Ø
Excitation current EXC. 4 mA
Ø
Input ranges 20 to ±0.3 Vpp
Ø
Signal bandwidth, see chap. signal bandwidth
Ø
ADC Resolution 18 bit
24 24
24 24

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 17
MTP-NT modules Chapter 4
MTP-NT-POT2
Acquisition module for 2
potentiometer sensors
MTP-NT-THERMO2
Acquisition module for 2
temperature sensors
Ø
Potentiometer resistance ≥ 120 Ω
Ø
Fixed excitation voltage: 4.0 V DC
Ø
Input resistance: 667 kΩ
Ø
Signal bandwidth, see chap. signal bandwidth
Ø
ADC Resolution: 18 bit
Ø
Sensor types:
RTD, Thermocouple, NTC,
(& customer-specific types)
Ø
Inputs galvanically isolated
(max. potential difference 32 V DC)
Ø
Measuring range:
-273.15 °C to +1635.2 °C
Ø
Lowpass filter: 1 Hz to 32 Hz
(programmable)
MTP-NT-BLUE
Bluetooth module to transfer
RS232 wirelessly*
MTP-NT-CONTROLLER
Controller for 1 to 128
acquisition modules
Ø
Remote On/Off* (concerns battery powered versions)
Ø
Range 5 to 20 m, depends on application and antenna
Ø
Power supply: 6 to 9 V DC
Ø
Current consumption: 37 mA (average)
* Required is the
KMT COMMUNICATOR
handheld remote control Blue-
tooth device with USB connector)
Ø
Output: PCM
built-in inductive transmitter
Ø
Programmable via RS232/USB adapter and remote
software
Ø
Power supply: 6 to 9 V DC
Ø
Current consumption: 100 mA
24

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 18
MTP-NT modules Chapter 4
coming soon
MTP-NT-RF-Tx
Radio transmitter
MTP-NT-ANALOG2
Two Channel Acquisition
Module for:
strain gauges*,
high level voltage signals*,
potentiometer sensors*,
IEPE/ICP® sensors*,
Sensor supply (12 V typ.)
Ø
RF output power: 10 mW / 50 mW
Ø
Modulation: FM (GMSK)
Ø
Frequencies: 300 MHz up to S-Band*
Ø
Data rates: 300 kBit/s to 10 Mbit/s*
Ø
Modulation input: TTL and RS422
Ø
Power supply: 5 to 9 V DC
Ø
Current consumption: 100 mA
*depends on version
*The functionality is programmable by the NT control
software: ntconfig.exe.
imc article no.: 13220141, order code: MTP-NT-ANALOG2-
SET
Set includes: acquisition module with sensor supply for
2channels for VOLT, IEPE, STG, POT (standard housing:
standard temperature range: -40°C to +85°C), sensor cable
500mm with open end (2x 4-pin), bus cable for MTP-NT
modules length 120mm
Common characteristics / Environment
Dimension
Weight
60 x 40 x 10 mm
42 g
Vibration (random)
Vibration (sine)
Shock (½ sine)
Static Acceleration
0.1 g²/Hz (20 Hz to 2 kHz)
20 g (20 Hz to 2 kHz)
10000 g peak (11 ms)
3000 g (depends of
mounting!)
Operating temperature
optional
Storage temperature
Humidity
-40 to +85°C
-40 to +125°C
-40 to +125°C
100 %
Table 1: Common specifications of MTP-NT modules

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 19
MTP-NT modules Chapter 4
4.1.1 Pin configuration

© 2023 imcTest & Measurement GmbH imc MTP-NT - Manual, Edition 2 - 2023-11-09
Page 20
MTP-NT modules Chapter 4
Table of contents
Other Axiometrix Solutions Data Logger manuals

Axiometrix Solutions
Axiometrix Solutions imc CRONOS-SL User manual

Axiometrix Solutions
Axiometrix Solutions imc CRONOS-XT User manual

Axiometrix Solutions
Axiometrix Solutions imc SPARTAN User manual

Axiometrix Solutions
Axiometrix Solutions imc CRONOSflex User manual

Axiometrix Solutions
Axiometrix Solutions imc C Series User manual