AZ 9811 User manual

OPERATION MANUAL
MULTI-FUNCTION DATALOGGER
WITH PRINTER
MULTI-FUNCTION DATALOGGER
WITHOUT PRINTER
9811
9861
9871
9881
9882
9680
9812 9851
WITH
PRINTER WITHOUT
PRINTER
9831
98315
9832
9833
9835
9611
9661
9671
9681
9682
9660
9612 9651
9631
96315
9632
9633
9635

INDEX
Introduction
Material Supplied
Features
Comparison table
Meter keypad - with printer
Meter keypad - without printer
Accessory photo
Top cover of meter
Meter setting
Single measurement
Multiple measurement
Automatic logging
Diagram
9811/9611/9812/9612 IR thermometer
9871/9671 Anemometer +Psychrometer
9881/9882/9681/9682 Thermometer
9861/9661 pH/mV Meter
9680/9660 IrDAReceiver
983X /963X Manometers
9851 /9651 Hygo-thermometer
Software
File
Mode
Port
Commad
Print
Specification sheet
Trouble shooting
1
1
1
2
5
6
7
8
10
11
12
13
14
20
22
24
30
35
40
44
45
46
46
47
48
51
...............................
...................................
.........................
.........................
..............
..........
..........................
........................
...............................
.......................
.....................
..........................
.....
..................
....
........
........................................
...................
.............
.......................................
.......................................
...................................
...................................
.......................
..........................
...................

This meter designed with three measurement modes:
1)Single point measurement
2)Multiple points measurement ( Manually record)
3)Automatically Logging
INTRODUCTION
MATERIAL SUPPLIED
Features
Check for damaged or missing parts in your meter before starting.
Thank you for purchasing this multiple function printer! This unit
has been developed to meet your max.satisfaction by its user-
friendly design. Please review the entire manual for a complete
overview of how to operate this meter.
The complete meter set should contain
User friendly interface
RS232 cable and software enable to link with PC to download
Backlight function
Tripod mountable for long time use
Power off time selectable
Big Dot matrix LCD
Powered by 4pcs AA (98X1) orAAA (96X1) batteries or 9V adaptor
Measuring/Programming ....Anywhere, anytime
1
& upload
1. Meter
2. 4pcs AAbatteries
3. Printing Thermo-paper ( For printer models only)
4. Operation manual
5. Carry Case
6. PH probe & calibration solution (for 9861/9661) or fan (for 9871/
9671) or K Type thermo couple (for 9881& 9882/9681& 9682) or
RH probe (for 9851/9651) or tube ( for manometer meters)
7. RS232 cable
8. Software CD
Printing anywhere, anytime ( with printer models)

COMPARISON TABLE
Measured parameters of each meter:
Temperature
IR Thermometer
9811/
Temperature
TemperatureDiff.
Dual K Type Thermometer
9881/
pH value, Voltage
Temperature
pH meter
9861/
Velocity,
Temperature
Wet Bulb, Air Volume
Humidity
Anemometer
9871/
Dual K.J.T.R.S E Type
Thermometer
9882/
Compatible
with AZIrDA products
IrDA receiver
9680/
MODEL FUNCTION PARAMETERS
2
9812/ 6 IR + externalprobe Meter
9611
9681
9661
9871
9682
9680
9612
Temperature,DP
Humidity, Wet Bulb
9851/ 9651
Hygro-thermometer
9832/
9632
+/- 2 psiMamometer
Pressure Differential
9835/
9635
+/- 5 psiMamometer
98315/
96315
+/- 15 psiMamometer
9833/
9633
+/- 30 psiMamometer
9831/
9631
+/- 100 psiMamometer

Please refer to below for the difference of each measurement mode.
MEASUREMENT DESCRIPTION MEMORY POINT
Single Point
Measurement
Single point
measurement No Memory
Multiple Point
Measurement
File name editable
multiple point
measurement 99 points
Automatic
Logging Programmable
datalogging function
12000 points(9811/9611)
6000 points (9812/9612)
4000 points(9861/9661)
2400 points(9871/9671)
4000 points(9881/9681)
4000 points(9882/9682)
(At most)
12000 points(9680/9660)
3000 points(9851/9651)
12000 points(9832/9632)
12000 points(9835/9635)
12000 points(98315/96315)
12000 points(9833/9633)
12000 points(9831/9631)
3

Comparison table of multiple points and datalogging measurements
Note 1: Eachrecord is designed to show withcurrent date and
time if userdoesn't edit any.
For example if the filename is "05-06 09:21:51" means thedate
is 6th May(or 5th June, based on yourdata mode
setting )and thetime is 09:21:51.
Note 2: Eachrecord is designed to show withthe current date
and time.
Note 3: a)To set upBegin-Date,Start-Time,End-Date,Suspend-
time and samplerate from the meter.
b)Each meter startsto record from Begin-Date & timewith
specified sample rateuntil Suspend-time.
c)Automatically start againnext day from Start-Time until
End-Date.
d)Logging stops recordingwhen End-Date or max.
memory points isachieved.
e)Logging can bestopped and start again with thesame
setting.
Note4:The total loggingmemory size is 12000 points, different
available parameters foreach meter:
Ex: 9871 has5 parameters, the total logging recordis
12000 .i.e. Eachparameter's capacity is 2400.
4
Editable or
Default with date
and time (Note 1)
Default (Note 2)
Press "ON/OFF" key to
measure and store
by pressing specified
keys
MEASURING /
SAMPLING
Automatically measure
and store according to
pre-set parameters
(Note 3)
MULTIPLE POINT
MEASUREMENT DATALOGGING
RECORD 99 points At most 12000 points
(Note 4)
FILE
NAME

METER KEYPAD-WITH PRINTER
5
ON/OFF
12
5
8
0
3
6
9
4
7
F2 F3 F4F1
SYM.
GHI
PQRS
DEF
MNO
WXYZ
ABC
JKL
TUV
LINE
FEED
Based on different functions, the
top cover connectorand color are
different.
TopCover
LCD
Keypad
Backlight
Up and Downkeys
Paper Roll cover
Welcome
MEAS MEM LOG SET
Function keys
Corresponding
1SYM stands for"1,*,.,:,$,+,-,="
2ABC stands for"2,a,b,c,A,B,C"
3DEF stands for"3,d,e,f,D,E,F"
4GHI stands for"4,g,h,i,G,H,I"
5JKL stands for"5,j,k,l,J,K,L"
6MNO stands for"6,m,n,o,M,N,O"
7PQRS stands for"7,p,q,r,s,P,Q,R,S"
8TUV stands for"8,t,u,v,T,U,V"
9WXYZ stands for"9,w,x,y,z,W,X,
Y,Z"
0 stands for"0 and space"
DC adaptor port
RS232 Port
External Probe Port(9812 only)

METER KEYPAD-WITHOUT PRINTER
METER KEYPAD
Welcome
MEASMEMLOGSET
ON/OFF
12
5
8
0
3
6
9
4
7
F2F3F4
F1
SYM.
GHI
PQRS
DEF
MNO
WXYZ
ABC
JKL
TUV
LINE
FEED
Big dot
matrix LCD
Toview
previous
/next record
Based on diff. functions,
the top coverconnector
and color aredifferent.
TopCover
Keypad
Backlight
1SYM stands for"1,*,.,:,$,+,-,="
2ABC stands for"2,a,b,c,A,B,C"
3DEF stands for"3,d,e,f,D,E,F"
4GHI stands for"4,g,h,i,G,H,I"
5JKL stands for"5,j,k,l,J,K,L"
6MNO stands for"6,m,n,o,M,N,O"
7PQRS stands for"7,p,q,r,s,P,Q,R,S"
8TUV stands for"8,t,u,v,T,U,V"
9WXYZ stands for"9,w,x,y,z,W,X,
Y,Z"
0 stands for"0 and space"
DC adaptor port
RS232 Port
External Probe Port
(9612 only)
Function keys
Press F1~
F4 key to select
the needed
function
Corresponding
MEM
MEAS
LOG
SET
6

7
ACCESSORY
9871
9671
The temperature and humidity
sensors are built in thefan, so
remember to rotate the cover
before using to get accurate
reading.
9861
9661
9881/9882/9681/9682
When first time using or the probe
hasn't been used for a long time,
please calibrate the probe first
by following the procedure in
page 20.
Please always keep the pH glass
bulb wet by using the cap to
protect and store the electrode.
Always rinse the pH eletrode in
de-ionized water or rinse solution
(tap water.....) before next use.
pH connector Temp.connector
9881/9882 both aredual-input
thermometers. Please plugthe
thermocouple probe intothe top
cover with correctpolarity "+" / "-"
and T1/T2 symbols.

TOP COVER -CONNECTOR
9871/9671 Anemometer
9851/9651
9881/9681 K Thermometer
9882/9682 KJTRSE thermometer
9811/9812/9611/9612
Infrared Thermometer
9680/9660 IrDAprinter9861/9661 pH meter
9832/9835/98315/9833/9831
Manometer
9632/9635/96315/9633/9631
The following illustrations are the connectorsfor different
printers:
REMARKS:
Welcome any OEM for different kind ofparameters .
9821 Sound LevelMeter connector's illustration is provided
when require .
8
Hygro-thermometer

9680/9660 IrDA RECEIVING METER
9
An IrDAlike module is built in themeter 9680/9660 at the top ,
better target theIrDA within 30 degree angletoward any
of AZIrDA meters for receiving data.
Make sure youhave disabled Auto power off from both
AZ IrDAmeter (transmitter )and IrDA receiver when
you need tohave long-term measurement.
IrDA port
IrDA port
IrDA meter
example:
8726 Psychrometer

LCD Cont.(1-5): LCD brightness. From darkest 1 to brightest 5
Prn Cont. (1-9): Printing darkness. From lightest 1 to heaviest 9
Unit: The unit could be metric or imperial / or
Auto Off: The selectable time frame is 1 to 20 min.
CF
Set Clock: To choose the date mode and set your local time.
Date mode:MM-DD-YY or DD-MM-YY or YY-MM-DD
Set ID: If choose "Disable", the ID will not be printed out.
ID: To edit an ID of this printer , the ID will be printed out at
printing mode.
Descriptions :
Select item: To select which measured parameters need to be
showed on the LCD. The unit of each parameter
could be selected from here as well.
Pressing or key to shift the cursor.
Pressing EDIT to enter modification mode.
Pressing PRN to enter printing mode.
Pressing NEXT/BACK to enter next or previous page.
Pressing EXIT to return to main menu
METER SETTING
Before measuring, pleasecheck the meter setting first toconfirm
the basic settingsof the meter are what youneed.
Toenter each command, just press thecorresponding F1 to F4
key.
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
SET
F4 :Meter Setting
10

There are threemeasurement modes :
1. Single measurement(MEAS)
2. Multiple measurement(MEM)and 3. Auto logging (LOG).
Press ON/OFF key to measure the temperature for 9811 and
9611( No printer function ).
Press F1 (MEAS) to proceed single measurement for other
meters .
On 9812/9612, the external probe temp. is displayed on LCD
once the probe is plugged.
After entering measurement mode , press F4 (PRN) to enter
printing mode. The printing can be stopped any time by press
F1(STOP or EXIT) key while it is printing .
PH & external probe calibration mode introduction are in the
mode of Single measurement .
Definition
SINGLE MEASUREMENT
MEAS
F1 :Single Measurement
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
11
Operating the singlemeasurement as a general meter.
The printing contrastcan be changed by pressing HIGHor
LOW key .

MULTIPLE MEASUREMENT
This is tomanually record what you measured withreal time
, and filename (a note or identification forthe record )is edit-
able to memorizeor recognize .
There are total99 memorize capacities in this measurement.
Press ON/OFF ( IR models 9811/9611/9812/9612) or MEAS
(other models) to measure the parameters.
Select F1(ABORT) or F4(SAVE) to exit the measurement
or memory the record .
Press F3 ( Edit ) to edit the file name of recorded value .
While editing the file name, select from the keys 1SYM, 2ABC,
3DEF, 4GHI...., Press and hold one of the key to select from
the displayed letters by releasing the key .
Press CLR shortly to delete one data or press for over 2 seconds
to delete the whole memory.
Before printing, select the printing range by pressing EDIT
key,then press START to print.
Definition
12
F2 :Multiple measurement
MEM
F2 F3 F4F1
Welcome
MEAS MEM LOG SET

AUTOMATIC LOGGING
Press SET to set needed setting first. The Date mode is
based on the mode you set under SET (see page 10). The
sampling rate is from 1 to 7200 seconds. "Expect" means
total memory of this meter, "Remain" means how many
memory left in meter.
Press START to begin the logging function. While logging:
Press VIEW to see the data ( more than one ) in the screen,
or press MEAS to see a real-time data,
or press STOP to quit logging.
Press P-PG or N-PG to review previous or next 100 points.
After stopping, press START to begin again. The sampling rate
and previous record are remained if the previous setting
has not been changed.
"Suspend" is the stop time of each day during setting date.
If you want to record 24 hours a day, you have to set :
00:00:00 as "Start" , and 23:59:59 as "Suspend" .
Definition
F2 F3 F4F1
Welcome
MEAS MEM LOG SET
F3 :Datalogging
LOG
This is toautomatically record what you set upbefore
measurement with realtime, first to set records start/stop
date and time,sample rate , memory points. The screen
content shows Expectmemory points and Remain memory
points while insetting.
13

14
9811/9611 Infrared thermometer Setting / Singlemeasurement
1.No PRN function is existing for model 9611 IR meter.
2.Emi. Rate: Emissivity. The range is 0.30 to 1.00
3.Laser: To enable or disable laser targeting. While in
single /multiple measurement, user could also press
ON/OFF + F3 buttons to power on /off the laser.
EDIT PRN
EXIT BACK
Set Clock:
MM-DD-YY HH:MM:SS
Set ID:
- - : :20
06 30 05 18 29
Disable
ID:
User Name
EDIT PRN
EXIT NEXT
Emi. Rate:
LCD Cont.(1-5):
Prn Cont. (1-9):
Unit:
Laser:
Auto Off:
0.95
3
5
Enable
20mins
Enable
C
MEAS MEM LOG SET
Welcome
C
EXIT PRN
Press ON toMeasure
T:30.5
YES NO
Press ON toMeasure
Print?
HIGH LOW
Press ON toMeasure
Cont 5
STOP
Remarks:

15
9812/9612 IR meterw/ probe Setting / Single measurement
1.No PRN function is existing for model 9612 IR meter.
2.Emi. Rate: Emissivity. The range is 0.30 to 1.00
3.Laser: To enable or disable laser targeting. While in
single /multiple measurement, user could also press
ON/OFF + F3 buttons to power on /off the laser.
4. See page 19 for the external probe calibration.
EDIT PRN
EXIT BACK
Set Clock:
MM-DD-YY HH:MM:SS
Set ID:
- - : :20
06 30 05 18 29
Disable
ID:
User Name
EDIT PRN
EXIT NEXT
Emi. Rate:
LCD Cont.(1-5):
Prn Cont. (1-9):
Unit:
Laser:
Auto Off:
0.95
3
5
Enable
20mins
Enable
C
MEAS MEM LOG SET
Welcome
C
EXIT PRN
Press ON toIr Meas
Ext:30.5
Ir:
Remarks:
CALI
Press on/off key
C
EXIT PRN
Press ON toIr Meas
Ext:30.5
Ir: 29.8
CALI
C

EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
T:-0.3C
02:06-30 02:28:45
T:26.7C
03:06-30 02:28:55
T:111C
01:06-30 02:28:29
T:-0.3C
02:USER name 1111 :USER name 1111
T:26.7C T:26.7C
YES NO
Press ON toMeasure
Clear?
01:06-30 02:28:29
T:-0.3C
02:
YES NO
Press ON toMeasure
Clear All?
From Point:
From Point: 99
1
EDIT
ESC START
EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
T:-0.3C
02:USER name 1111
T:26.7C
03:06-30 02:28:55
T:111C
Short press
EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
T:-0.3C
02:
T:
03:06-30 02:28:55
T:111C
Long press
MEAS MEM LOG SET
Welcome
9811/9611 Infrared thermometer Multiple measurement
Remarks:
1.No PRN function is existing for model 9611 IR meter.
2.Short press CLR to clear the highlighted value and file
name. Long press CLR to clear all the data ( values and
file names ) in the meter. Make sure by pressing YES ,or
you won't be able to recall any data anymore .
16

EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
Ext:-0.3C
Ir: 15.0C
02:06-30 02:28:45
01:06-30 02:28:29
02:USER name 1111 :USER name 1111
YES NO
Press ON toMeasure
Clear?
01:06-30 02:28:29
02:
YES NO
Press ON toMeasure
Clear All?
From Point:
From Point: 99
1
EDIT
ESC START
EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
USER name 1111
Short press
EDIT CLR
Press ON toMeasure
EXIT PRN
01:06-30 02:28:29
Long press
MEAS MEM LOG SET
Welcome
9812/9612 Infrared thermometerMultiple measurement
Remarks:
1.No PRN function is existing for model 9612 IR meter.
2. If the probe is not plugged, press ON/OFF key to get IR temp.
If the probe is plugged, press MEAS to get external probe only
or press ON/OFF key to get both IR and externaltemperature.
3.Short press CLR to clear the highlighted value and file
name. Long press CLR to clear all the data ( values and
file names ) in the meter. Make sure before pressing YES,or
you won't be able to recall any data back anymore .
17
Ext:
Ir:
Ext:-0.3C
Ir: 15.0C
02: Ext:
Ir:
Ext:-0.3C
Ir: 15.0C
Ext:-0.3C
Ir: 15.0C
Ext:-0.3C
Ir: 15.0C
02:06-30 02:28:45
Ext:
Ir:

START
One Page = 100 points
EXIT
00001:
T:-0.3C
06-30 02:28:55
00002:
T:-0.5C
06-30 02:29:55
00003:
T:-0.6C
06-30 02:30:55
SET NEXT
One Page =100 points
00001:
T:-0.3C
06-30 02:28:55
00002:
T:-0.5C
06-30 02:29:55
00003:
T:-0.6C
06-30 02:30:55
N-PG PRN
P-PG BACK
EDIT VIEW
EXIT NEXT
Begin:
Start:
End:
Suspend:
Rate:
Expect:
Remain:
30-06-05
02:28:55
02-07-05
03:28:55
60Sec(s)
12000Point(s)
11997Point(s)
Begin:
Start:
30-06-05
02:28:55
CLR PRN
START BACK
End:
Suspend:
Rate:
Expect:
Remain:
02-07-05
03:28:55
60Sec(s)
12000Point(s)
11997Point(s)
STOP VIEW
Logging...
STOP ESC
00004:
T:-0.3C
06-30 02:31:55
00005:
T:-0.5C
06-30 02:32:55
00006:
T:-0.6C
06-30 02:33:55
YES NO
Begin:
Start:
End:
Suspend:
Remain:
30-06-05
02:28:55
02-07-05
03:28:55
12000Point(s)
Clear All?
18
MEAS MEM LOG SET
Welcome
9811/9611/9812/9612 IR Thermometer Datalogging measurement
Remarks:
1.No PRN function is existing
for model 9611 IR meter.
2. "Start" is the start time of
each date during setting date.
4."Begin" is the start date of automatically recording.
5."End" is the stop date of datalogging.
6. Ext. is valid for model #9812 & 9612.
(EX:9811)
3."Suspend" is thestop time of each
date during settingdate.If you want to record 24hours a day,
you have toset : 00:00:00 as "Start" ,and 23:59:59 as
"Suspend" .
This manual suits for next models
25
Table of contents