AZ 9811 User manual

OPERATION MANUAL
MULTI-FUNCTION DATALOGGER
WITH PRINTER
MULTI-FUNCTION DATALOGGER
WITHOUT PRINTER
9811
9861
9871
9881
9882
9680
9812 9851
WITH
PRINTER WITHOUT
PRINTER
9831
98315
9832
9833
9835
9611
9661
9671
9681
9682
9660
9612 9651
9631
96315
9632
9633
9635

INDEX
Introduction
Material Supplied
Features
Comparison table
Meter keypad - with printer
Meter keypad - without printer
Accessory photo
Top cover of meter
Meter setting
Single measurement
Multiple measurement
Automatic logging
Diagram
9811/9611/9812/9612 IR thermometer
9871/9671 Anemometer +Psychrometer
9881/9882/9681/9682 Thermometer
9861/9661 pH/mV Meter
9680/9660 IrDAReceiver
983X /963X Manometers
9851 /9651 Hygo-thermometer
Software
File
Mode
Port
Commad
Print
Specification sheet
Trouble shooting
1
1
1
2
5
6
7
8
10
11
12
13
14
20
22
24
30
35
40
44
45
46
46
47
48
51
...............................
...................................
.........................
.........................
..............
..........
..........................
........................
...............................
.......................
.....................
..........................
.....
..................
....
........
........................................
...................
.............
.......................................
.......................................
...................................
...................................
.......................
..........................
...................

This meter designed with three measurement modes:
1)Single point measurement
2)Multiple points measurement ( Manually record)
3)Automatically Logging
INTRODUCTION
MATERIAL SUPPLIED
Features
Check for damaged or missing parts in your meter before starting.
Thank you for purchasing this multiple function printer! This unit
has been developed to meet your max.satisfaction by its user-
friendly design. Please review the entire manual for a complete
overview of how to operate this meter.
The complete meter set should contain
User friendly interface
RS232 cable and software enable to link with PC to download
Backlight function
Tripod mountable for long time use
Power off time selectable
Big Dot matrix LCD
Powered by 4pcs AA (98X1) orAAA (96X1) batteries or 9V adaptor
Measuring/Programming ....Anywhere, anytime
1
& upload
1. Meter
2. 4pcs AAbatteries
3. Printing Thermo-paper ( For printer models only)
4. Operation manual
5. Carry Case
6. PH probe & calibration solution (for 9861/9661) or fan (for 9871/
9671) or K Type thermo couple (for 9881& 9882/9681& 9682) or
RH probe (for 9851/9651) or tube ( for manometer meters)
7. RS232 cable
8. Software CD
Printing anywhere, anytime ( with printer models)

COMPARISON TABLE
Measured parameters of each meter:
Temperature
IR Thermometer
9811/
Temperature
TemperatureDiff.
Dual K Type Thermometer
9881/
pH value, Voltage
Temperature
pH meter
9861/
Velocity,
Temperature
Wet Bulb, Air Volume
Humidity
Anemometer
9871/
Dual K.J.T.R.S E Type
Thermometer
9882/
Compatible
with AZIrDA products
IrDA receiver
9680/
MODEL FUNCTION PARAMETERS
2
9812/ 6 IR + externalprobe Meter
9611
9681
9661
9871
9682
9680
9612
Temperature,DP
Humidity, Wet Bulb
9851/ 9651
Hygro-thermometer
9832/
9632
+/- 2 psiMamometer
Pressure Differential
9835/
9635
+/- 5 psiMamometer
98315/
96315
+/- 15 psiMamometer
9833/
9633
+/- 30 psiMamometer
9831/
9631
+/- 100 psiMamometer

Please refer to below for the difference of each measurement mode.
MEASUREMENT DESCRIPTION MEMORY POINT
Single Point
Measurement
Single point
measurement No Memory
Multiple Point
Measurement
File name editable
multiple point
measurement 99 points
Automatic
Logging Programmable
datalogging function
12000 points(9811/9611)
6000 points (9812/9612)
4000 points(9861/9661)
2400 points(9871/9671)
4000 points(9881/9681)
4000 points(9882/9682)
(At most)
12000 points(9680/9660)
3000 points(9851/9651)
12000 points(9832/9632)
12000 points(9835/9635)
12000 points(98315/96315)
12000 points(9833/9633)
12000 points(9831/9631)
3

Comparison table of multiple points and datalogging measurements
Note 1: Eachrecord is designed to show withcurrent date and
time if userdoesn't edit any.
For example if the filename is "05-06 09:21:51" means thedate
is 6th May(or 5th June, based on yourdata mode
setting )and thetime is 09:21:51.
Note 2: Eachrecord is designed to show withthe current date
and time.
Note 3: a)To set upBegin-Date,Start-Time,End-Date,Suspend-
time and samplerate from the meter.
b)Each meter startsto record from Begin-Date & timewith
specified sample rateuntil Suspend-time.
c)Automatically start againnext day from Start-Time until
End-Date.
d)Logging stops recordingwhen End-Date or max.
memory points isachieved.
e)Logging can bestopped and start again with thesame
setting.
Note4:The total loggingmemory size is 12000 points, different
available parameters foreach meter:
Ex: 9871 has5 parameters, the total logging recordis
12000 .i.e. Eachparameter's capacity is 2400.
4
Editable or
Default with date
and time (Note 1)
Default (Note 2)
Press "ON/OFF" key to
measure and store
by pressing specified
keys
MEASURING /
SAMPLING
Automatically measure
and store according to
pre-set parameters
(Note 3)
MULTIPLE POINT
MEASUREMENT DATALOGGING
RECORD 99 points At most 12000 points
(Note 4)
FILE
NAME

METER KEYPAD-WITH PRINTER
5
ON/OFF
12
5
8
0
3
6
9
4
7
F2 F3 F4F1
SYM.
GHI
PQRS
DEF
MNO
WXYZ
ABC
JKL
TUV
LINE
FEED
Based on different functions, the
top cover connectorand color are
different.
TopCover
LCD
Keypad
Backlight
Up and Downkeys
Paper Roll cover
Welcome
MEAS MEM LOG SET
Function keys
Corresponding
1SYM stands for"1,*,.,:,$,+,-,="
2ABC stands for"2,a,b,c,A,B,C"
3DEF stands for"3,d,e,f,D,E,F"
4GHI stands for"4,g,h,i,G,H,I"
5JKL stands for"5,j,k,l,J,K,L"
6MNO stands for"6,m,n,o,M,N,O"
7PQRS stands for"7,p,q,r,s,P,Q,R,S"
8TUV stands for"8,t,u,v,T,U,V"
9WXYZ stands for"9,w,x,y,z,W,X,
Y,Z"
0 stands for"0 and space"
DC adaptor port
RS232 Port
External Probe Port(9812 only)

METER KEYPAD-WITHOUT PRINTER
METER KEYPAD
Welcome
MEASMEMLOGSET
ON/OFF
12
5
8
0
3
6
9
4
7
F2F3F4
F1
SYM.
GHI
PQRS
DEF
MNO
WXYZ
ABC
JKL
TUV
LINE
FEED
Big dot
matrix LCD
Toview
previous
/next record
Based on diff. functions,
the top coverconnector
and color aredifferent.
TopCover
Keypad
Backlight
1SYM stands for"1,*,.,:,$,+,-,="
2ABC stands for"2,a,b,c,A,B,C"
3DEF stands for"3,d,e,f,D,E,F"
4GHI stands for"4,g,h,i,G,H,I"
5JKL stands for"5,j,k,l,J,K,L"
6MNO stands for"6,m,n,o,M,N,O"
7PQRS stands for"7,p,q,r,s,P,Q,R,S"
8TUV stands for"8,t,u,v,T,U,V"
9WXYZ stands for"9,w,x,y,z,W,X,
Y,Z"
0 stands for"0 and space"
DC adaptor port
RS232 Port
External Probe Port
(9612 only)
Function keys
Press F1~
F4 key to select
the needed
function
Corresponding
MEM
MEAS
LOG
SET
6

7
ACCESSORY
9871
9671
The temperature and humidity
sensors are built in thefan, so
remember to rotate the cover
before using to get accurate
reading.
9861
9661
9881/9882/9681/9682
When first time using or the probe
hasn't been used for a long time,
please calibrate the probe first
by following the procedure in
page 20.
Please always keep the pH glass
bulb wet by using the cap to
protect and store the electrode.
Always rinse the pH eletrode in
de-ionized water or rinse solution
(tap water.....) before next use.
pH connector Temp.connector
9881/9882 both aredual-input
thermometers. Please plugthe
thermocouple probe intothe top
cover with correctpolarity "+" / "-"
and T1/T2 symbols.

TOP COVER -CONNECTOR
9871/9671 Anemometer
9851/9651
9881/9681 K Thermometer
9882/9682 KJTRSE thermometer
9811/9812/9611/9612
Infrared Thermometer
9680/9660 IrDAprinter9861/9661 pH meter
9832/9835/98315/9833/9831
Manometer
9632/9635/96315/9633/9631
The following illustrations are the connectorsfor different
printers:
REMARKS:
Welcome any OEM for different kind ofparameters .
9821 Sound LevelMeter connector's illustration is provided
when require .
8
Hygro-thermometer
This manual suits for next models
25
Table of contents