B.O.L.T VA 01 User manual

ONE-TOUCH WIRELESS HEALTH TRACKER
BODY LIFE TRACKER
User Manual
Model: VA 01
Document No : AMI-PRD-UM-B-VA01
Version : 4.0
Date : 08.03.2018

B.O.L.T User Manual Model No: VA 01
2
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Legal
Disclaimer
This publication/content contains proprietary information which is protected by copyright. No
part of this publication may be reproduced, transcribed, stored in a retrieval system, translated
into any language or computer language, or transmitted in any form whatsoever without the prior
written consent of the publisher. American Megatrends India Private Ltd. retains the right to
update, change or modify this publication at any time, without notice.
For Additional Information
Call American Megatrends India Private Ltd at 1800-200-8001.
Limitations of Liability
In no event shall American Megatrends India Private Ltd be held liable for any loss, expenses, or
damage of any kind whatsoever, whether direct, indirect, incidental, or consequential, arising
from the design or use of this product or the support materials provided with the product.
Limited Warranty
No warranties are made, either expressed or implied, with regard to the contents of this work, its
merchantability, or fitness for a particular use. American Megatrends India Private Ltd assumes
no responsibility for errors and omissions or for the uses made of the material contained herein
or reader decisions based on such use.
Trademark and Copyright Acknowledgments
Copyright © 2018 American Megatrends India Private Ltd. All Rights Reserved.
AMERICAN MEGATRENDS INDIA PRIVATE LTD.,
KUMARAN NAGAR,
SEMMENCHERY, OFF RAJIV GANDHI SALAI (OMR),
CHENNAI (TN) 600119.
All product names used in this publication are for identification purposes only and are
trademarks of their respective companies.

B.O.L.T User Manual Model No: VA 01
3
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Document History
Version
Date
Comment
1.0
31-12-2015
Initial Release
2.0
23-03-2015
Added battery care section
3.0
31-12-2015
Included FCC statement
4.0
08-03-2018
Updated the Images and related contents

B.O.L.T User Manual Model No: VA 01
4
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Table of Contents
1. Intended Use ...................................................................................... 5
2. Product Description ............................................................................. 5
3. Package Contents of BOLT VA 01 ............................................................. 6
4. Product Quality, Reliability and Safety ...................................................... 7
4.1 Warning....................................................................................... 7
4.2 Caution ....................................................................................... 9
4.3 Care and Maintenance ..................................................................... 9
4.4 Disposal ....................................................................................... 9
5. Contraindications ............................................................................... 10
6. Product Features................................................................................ 10
7. Operating Environment ........................................................................ 10
8. Prerequisites..................................................................................... 10
9. Using B.O.L.T Application ..................................................................... 11
10. Blood Pressure Measurement Procedure ................................................ 11
10.1 Blood Pressure measurement with B.O.L.T........................................ 12
10.2 Blood Pressure Classification for Adults ............................................ 13
11. Blood Oxygen Level Measurement Procedures ......................................... 14
11.1 Blood Oxygen Level measurement with B.O.L.T.................................. 14
11.2 Blood Oxygen Level Classification ................................................... 15
12. Temperature Measurement Procedures ................................................. 16
12.1 Body Temperature measurement with B.O.L.T ................................... 16
12.2 Temperature Classification ........................................................... 17
13. Body Mass Index (BMI) ....................................................................... 17
13.1 Measuring BMI with B.O.L.T........................................................... 17
13.2 BMI Classification........................................................................ 17
14. Battery Care................................................................................... 18
14.1 Replacement of Battery Pack......................................................... 18
15. Troubleshooting .............................................................................. 20
16. Explanation of Indicators/Symbols ........................................................ 22
17. Technical Specifications .................................................................... 24
18. Certifications .................................................................................. 25
Warranty Information................................................................................ 27
Customer Care Support.............................................................................. 27
Contact us.............................................................................................. 27

B.O.L.T User Manual Model No: VA 01
5
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Model VA 01 –NIBP Monitor (Systole, Diastole and Pulse Rate), Infrared
Thermometer (Temperature) and Pulse Oximeter (SpO2 & Pulse Rate)
1. Intended Use
B.O.L.T VA 01 is intended to measure Blood Pressure (BP), Body Temperature, Blood Oxygen
saturation (SpO2) of an adult user. The B.O.L.T device is controlled by a mobile device
(Smartphone / Tablet), and can be used by a physician, doctor in a hospital environment and
by users in a home environment.
2. Product Description
The B.O.L.T VA 01 device is a medical gadget with NiBP (Non-invasive Blood Pressure), Pulse
Oximeter (SpO2) and Infrared Thermometer (IRT) that gets controlled from a smartphone/
tablet. The B.O.L.T device is a cloud-enabled solution, where your health vitals can be stored
in your personal health cloud.
Know Your Unit
The base unit has an elegant look and feel with two LED indicators, an accessory connector
and a power ON/OFF sliding switch as shown below. Accessories like cuff, IR Thermometer
with dust cover, SpO2 probe and USB cable with power adapter are provided along with the
base unit.

B.O.L.T User Manual Model No: VA 01
6
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
3. Package Contents of BOLT VA 01
S. No
Packing List
Quantity
1
Base Unit
1
2
Cuff
1
3
IR Thermometer (IRT) Probe
1
4
Dust Cover
1 pack
5
SpO2 probe
1
6
Power Adapter
1
7
USB Cable
1
8
Warranty Card
1
9
Quick Reference Guide
1
10
Base Unit USB Plug
1
11
Lemo Connector Plug
1

B.O.L.T User Manual Model No: VA 01
7
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
4. Product Quality, Reliability and Safety
The device has been designed with an emphasis on quality, reliability and safety, but AMI can
only accept responsibility for these aspects, provided the following conditions are met
The device should be used as per the operating instructions mentioned in the user
manual provided by AMI.
All modifications and repairs to the device should be carried out by authorized AMI
personnel or their agents.
The user must follow the regulations specified in the below warnings, cautions and
care & maintenance.
4.1 Warning
If you encounter any problem while taking blood pressure measurement, such as
inflation does not stop or air leakage in the cuff, remove the cuff or pull out the air
tube from the base unit.
Do not wrap the cuff around the arm where an intravenous injection or transfusion is
being given to the patient.
Do not operate the gadget in places where inflammable gas, such as highly
inflammable anesthetic, may be generated or in a high-pressure oxygen room or in an
oxygen tent.
Keep the gadget away from infants, small children or anyone who is incapable of
using the gadget in a correct manner.
The device is designed for adults and not recommended for the neonates, pediatrics
and infants.
The user is recommended to insert the given USB plug in the USB port of the base
unit during battery mode operation.
Inserting USB Plug Zoomed View

B.O.L.T User Manual Model No: VA 01
8
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Removing USB Plug Zoomed View
The user can remove the USB Plug while charging the device.
The user is recommended to insert the given lemo connector plug in the accessory
connector port when accessories are not connected.
Inserting Lemo Connector Plug Removing Lemo Connector Plug
The user can remove the Lemo connector plug while connecting the accessory.
Keep the USB plug and Lemo connector plug safe and use as per the above
instructions to protect the device from dust and to meet the ESD requirements.
Please do not use the same cuff for patients who are highly infectious as this practice
may cause cross-infection.
Do not use the cuff other than arm area.
Use dust cover for the IR Thermometer probe during the temperature measurement.
Dust covers are meant for Single user / Single use only.
If the thermometer probe is ever accidentally used without a dust cover attached the
readings may be incorrect. In that case, clean the lens with a soft cloth or cotton swab
moistened with alcohol.
Place the finger inside the SpO2 probe properly during SpO2 measurement.

B.O.L.T User Manual Model No: VA 01
9
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
4.2 Caution
Do not use the gadget while moving in a vehicle as this may result in erroneous
readings.
Do not use any other branded cuffs as this may result in inaccurate measurements.
Do not use unauthorized parts and accessories.
Do not store or use this gadget in locations which are maintained above the specified
temperature and humidity ranges.
Nail polish or false fingernails may cause inaccurate SpO2 readings.
SpO2 measurements may be adversely affected in the presence of high ambient light.
Use only American Megatrends India Specified batteries and charging devices.
4.3 Care and Maintenance
Store the gadget and the accessories in a clean and safe location.
Changes or modifications not approved by the manufacturer will void the user
warranty.
Keep the accessories and gadget away from rain, sweat, and water.
Do not disassemble, repair, or modify the device by yourself, as this could affect the
safety, and voids the warranty of the device if the seal is broken.
Clean the rubber touching the finger inside the SpO2 probe gently by a soft cloth
dampened with 70% isopropyl alcohol before measurement.
Clean the IRT sensor window with a soft cloth dampened with 70% isopropyl alcohol
before measurement.
Unexpected mechanical damage of the device must be intimated to the manufacturer
immediately.
4.4 Disposal
Dispose the instrument, accessories and consumables according to local disposal and
recycling laws.
This symbol is applicable for EU member countries only.

B.O.L.T User Manual Model No: VA 01
10
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
To avoid potential negative consequences for the environment and possibly human health,
care should be taken while disposing (i) for EU member countries - in accordance with WEEE
(Directive on Waste Electrical and Electronic Equipment), or (ii) for all other countries, in
accordance with local disposal and recycling laws.
The dust cover needs to be disposed after the single usage to avoid cross-
contamination.
The dust cover disposal after use should adhere to the local authority
guidelines/norms.
5. Contraindications
The B.O.L.T device is not recommended for people with serious arrhythmia. Consult your
doctor during pregnancy, arrhythmia and arteriosclerosis. The analyzed results from the
devices are not sufficient to make a correct diagnosis of the patient`s clinical condition. A
detailed clinical history of the patient is also required together with the results of any other tests
suggested by a doctor.
6. Product Features
Elegant design enables simple and easy use of the product.
Multiple Platform Support and same application for multiple users.
Secured Cloud application to share and manage trends with health data.
Monitor and share your health trends with the doctor and loved ones.
Safe and convenient to use.
7. Operating Environment
The B.O.L.T device has been designed for use in the hospitals, clinics or directly by the patient
at home to monitor the health conditions. The user or the physician is responsible for
ensuring that the device is stored and used in appropriate environmental conditions.
8. Prerequisites
Some basic requirements must be followed as mentioned below to ensure better operation
of the product.
B.O.L.T device is designed to be operated with applications like Android, iOS or
Windows.
The Android OS version of the Smartphone / Tablet should be 4.0 or higher.
The iOS version of the Smartphone / Tablet should be 7 or higher.
The Windows OS version of the Smartphone / Tablet should be 8 or higher.

B.O.L.T User Manual Model No: VA 01
11
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
9. Using B.O.L.T Application
Downloading and Installing B.O.L.T application on your mobile device
1. Download and Install B.O.L.T application from the Play store/Application
store/Windows application market.
2. On successful installation, launch the B.O.L.T application on the mobile device.
3. Create a User Name with your Email ID or use Facebook Credentials for login.
4. On successful Login, provide permission for cloud service by enabling the Save in
cloud option and enter near and dear details under settings panel at the left top
corner of the home view.
Note: You can also login as a guest user while internet unavailability
which might not store the measured vital parameters in the cloud storage
space on the measured parameters.
10. Blood Pressure Measurement Procedure
Mandatory instructions to be followed during blood pressure measurement
Relax yourself/user in a comfortable position.
Avoid eating, exercising and smoking for 30 minutes before taking a measurement.
Avoid taking measurements during stressful times.
Remove tight-fitting clothing from the right upper arm.
Sit in a chair with your feet flat on the floor and place the right arm on a table as
shown below.
Apply the cuff to the right upper arm so that the cuff is wrapped at the same level of
your heart.
Ensure that the arrow present in the cuff points towards the artery of the right hand
as shown below.

B.O.L.T User Manual Model No: VA 01
12
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
Stay calm without shaking the hand/body during the measurement.
10.1 Blood Pressure measurement with B.O.L.T
B.O.L.T enables connecting an air hose through which the pulses are picked-up and blood
pressure is monitored.
Connecting air hose with the gadget and launching B.O.L.T application
1. Insert the BP connector plug into the BP socket firmly as shown above.
2. Switch ON the gadget using the ON/OFF sliding switch.
3. Enable Bluetooth and Internet Connectivity on the mobile device.
4. Launch the B.O.L.T application on the mobile device.
5. Login with the User Name and Password which was used for the registration or use
Guest login.
Measuring BP with B.O.L.T
6. On successful login of the B.O.L.T application, Select “How is my health” option to
perform Master Health checkup or select “Check Vitals” option to perform the
individual test and continue.
7. Confirm the Bluetooth device to turn-on.
8. Select the B.O.L.T device from the list of available Bluetooth devices and confirm.
9. Provide default password (1234) for pairing your B.O.L.T device with the mobile
device on your first-time usage (only for Android).
10. Wrap the cuff around the upper arm of the right hand above the elbow.
11. Ensure that the arrow in the cuff points the artery along the middle finger of the right
hand.
12. Start the Blood Pressure measurement using the application screen.
13. Ensure that the person remains stable until the application displays the results.

B.O.L.T User Manual Model No: VA 01
13
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
14. On successful measurement, the Blood Pressure and Pulse rate are displayed and a
copy of reading will be mailed to your Near & Dear mail IDs on saving the data.
15. Multiple BP readings can be taken with 1-minute interval by selecting the auto-
reading option.
Note: On Successful pairing of the mobile device, Blue LED stops blinking
in the gadget. Ensure that the save option is enabled for storing the data
in the cloud.
10.2 Blood Pressure Classification for Adults
The World Health Organization (WHO) has created the following classification for assessing
high blood pressure (Hypertension). Please note that this table can give only a generic view
as other factors such as Age, diabetes, obesity, and smoking, also needs to be considered for
understanding the different ranges. Consult with your physician for accurate assessment.
Blood Pressure Classification
Systole
Diastole
Low
<110
<75
Normal
110-120
75-80
Pre-Hypertension (mild)
120-139
80-89
Stage 1 Hypertension (high)
140-159
90-99
Stage 2 Hypertension (severe)
>159
>99

B.O.L.T User Manual Model No: VA 01
14
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
11. Blood Oxygen Level Measurement Procedures
Mandatory instructions to be followed during blood oxygen level measurement
Remove nail polish or dirt present on the finger before the measurement.
Clean the surface of the fingertip before the measurement.
Relax yourself/user in a comfortable position.
Remain stable during the measurement.
Place the index finger properly inside the SpO2 probe.
11.1 Blood Oxygen Level measurement with B.O.L.T
B.O.L.T enables connecting a SpO2 probe through which the blood oxygen level is measured.
Connecting SpO2 probe with the gadget
Insert the SpO2 connector into the socket firmly as shown below.
Measuring Blood Oxygen Level with B.O.L.T
1. Clean the rubber pad of the SpO2 probe touching the finger gently with a soft cloth
dampened with 70% isopropyl alcohol and let air dry or use a soft dry cloth to clean
before measurement.
2. Clean your hands with hand wash before the measurement.
3. Select “Check Vitals” option to perform the individual test and continue.
4. Clip the SpO2 probe in the index finger of the person to be measured in right/left
hand as displayed above.
5. Select the Blood Oxygen option from the application screen.

B.O.L.T User Manual Model No: VA 01
15
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
6. On successful measurement, the SpO2 value and Pulse rate will be displayed and a
copy of reading will be mailed to your Near & Dear mail IDs on saving the data.
Note: Ensure to clean your hands before taking a SpO2 measurement. For some
readings, fluctuations may occur below 85% of SpO2 for certain ethnicity
group.
If the SpO2 values are deviated below 70% or above 100%, ensure that the
user is stable and positions his finger properly as shown below.
This is a continuous measurement procedure. Hence readings SpO2 will
continue to be displayed until the user stops the measurement/test.
11.2 Blood Oxygen Level Classification
Please note that this table can give only a generic view. Consult with your physician for
accurate assessment.
SpO2 Classification
Range
Hypoxemia (low)
< 95 %
Normal
95-100 %

B.O.L.T User Manual Model No: VA 01
16
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
12. Temperature Measurement Procedures
Mandatory instructions to be followed during temperature measurement
Relax yourself/user in a comfortable position.
For persons wearing hearing aids or earplugs, remove the device and wait 20 minutes
prior to taking a temperature measurement.
Use new dust cover for each measurement.
Place the thermometer probe firmly into the ear canal for accurate measurement.
Remain stable during the measurement.
Wait until the application displays the measured temperature.
12.1 Body Temperature measurement with B.O.L.T
B.O.L.T enables connecting an IR Thermometer probe through which the temperature is
measured.
Connecting IR Thermometer probe with the gadget
Insert the IR Thermometer connector into the socket firmly as shown below.
Measuring Body Temperature with B.O.L.T
1. Select “Check Vitals” option to perform the individual test and continue.
2. Use dust cover over the tip of the thermometer.
3. Place the thermometer inside the ear horizontally as such the pointer maintains a
horizontal position as displayed above.
4. Select the Body temperature option from the application screen.
5. On successful measurement, the temperature value is displayed and a copy of the
reading will be mailed to your Near & Dear mail IDs on saving the data.
6. Select the required unit (°C/°F) using the slide button in the application.

B.O.L.T User Manual Model No: VA 01
17
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
7. Kindly dispose the dust cover in the disposable container.
12.2 Temperature Classification
Please note that this table can give only a generic view. Consult with your physician
for accurate assessment.
Temperature Classification
Range
Hypothermia
<36.3 °C (< 97.5 °F)
Normal
36.4 –37.5 °C (97.6- 99.5 °F)
Hyperthermia
>37.5.°C (>99.5 °F)
13. Body Mass Index (BMI)
The Body Mass Index (BMI) is a measure of relative weight based on an individual's mass and
height. BMI provides a simple numeric measure of a person's thickness or thinness, allowing
health professionals to discuss overweight and underweight problems more objectively with
their patients.
13.1 Measuring BMI with B.O.L.T
1. Choose Body Mass Index option from the application screen.
2. Enter your height (feet/cm) and weight (lbs/kg) of the person to be measured in the
application.
3. On successful measurement, the BMI value is displayed which can be compared with
the above BMI range classification table.
13.2 BMI Classification
Please note that this table can give only a generic view. Consult with your physician for
accurate assessment.
BMI Range
Category
<20
Under Weight
20-25
Normal Weight
25-30
Over Weight
>30
Obesity

B.O.L.T User Manual Model No: VA 01
18
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
14. Battery Care
The power adapter is included in the pack and the specifications are mentioned
below.
AC input: 100-240V, Frequency: 50Hz to 60Hz, 0.35A Max, DC output: +5V @ 2A
Connect the power adapter to the power source and micro USB port to the base
unit`s USB Power Socket.
Charge the base unit for minimum two hours during the first time usage.
The mobile application indicates the battery low status when the battery level goes
below 25% and shows critically low status when the battery level goes below 10%.
Charge the base unit using the power adapter and view the charge level in the mobile
application software.
Even though Over-charging is mitigated in the design, it`s recommended to unplug
the power adapter from the power source when the charge level reaches 100%.
When charging is needed, please connect the base unit to the power source using the
power adapter.
The base unit can be operated by connecting to power source directly using the
power adapter or using the charged inbuilt battery (adapter not required).
The device can also work normally while charging.
14.1 Replacement of Battery Pack
It is highly recommended changing the battery of the base unit for every 1 year at the AMI
authorized service center. Use AMI recommended battery for replacement.
Replacement procedure
1. Switch off the base unit before removing the back cover for the battery replacement.
2. Remove the single screw on the upper portion of the battery cover as shown below.

B.O.L.T User Manual Model No: VA 01
19
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
3. Press and remove the battery cover in the recommended direction as shown below.
4. Disconnect the battery pack from the connector and replace with new one.
5. Install the battery cover and fasten with the screw.
6. Connect the base unit with AC adapter and then charge for more than twelve hours
before use.

B.O.L.T User Manual Model No: VA 01
20
© Copyright 2018, All Rights Reserved. American Megatrends India Private Ltd.
15. Troubleshooting
PROBLEM
POSSIBLE CAUSE
SOLUTION
Application not installing from
the App store/Play
store/Windows market
1. Internet/Data
disconnection
2. Memory space
unavailability
1. Check your Internet
connectivity
2. Move some of the
application from
Phone storage to
SD card
3. If the issue persists,
delete some
unwanted
application and try
to install B.O.L.T
application
Application Login problem
Internet/Data
disconnection
Enable Internet connection
through mobile data or Wi-
Fi and try to login
Change Password is not getting
updated
Internet/Data
disconnection
Enable internet connection
through mobile data or Wi-
Fi and try again
Device requests for Bluetooth
pairing password
Bluetooth pairing
permission required
Give the password as
1234/0000
Bluetooth communication
disconnected while measuring
vitals and Bluetooth indicator
starts blinking
Bluetooth
communication error
Close the application.
Restart the B.O.L.T device
and restart the entire
process again
B.O.L.T device switched ON, but
not showing in List of available
Bluetooth device in the
application
Bluetooth pairing
problem
Restart the B.O.L.T device,
Then try to connect again
B.O.L.T device switched ON, but
Bluetooth (Blue) LED not
blinking.
B.O.L.T device not
booted properly
Connect the respective
power adaptor to the
device and power ON, if
still blue LED is not glowing
kindly get it repaired in the
authorized service center.
Table of contents
Popular Measuring Instrument manuals by other brands

Varian
Varian FRG-700 series instruction manual

EarthLinked
EarthLinked FMK-1872 installation manual

ITRON
ITRON SHARPFLOW SWB7 quick start

Endress+Hauser
Endress+Hauser Master Meter System operating instructions

Polar Electro
Polar Electro 7700-0001 instruction manual

Savant
Savant SmartEnergy SEM-1024 Quick reference guide

Ruskin
Ruskin AIRFLOW-IQ Start-up & Commissioning Guide

PCB Piezotronics
PCB Piezotronics IMI Sensors TO625B01 Installation and operating manual

GE
GE EPM6000 instruction manual

Itm
Itm 89088 instruction manual

PCB Piezotronics
PCB Piezotronics 214B Installation and operating manual

AS
AS TFmini Plus quick start guide