3./ Voltage will auto set to 45V max, this can be checked by switching the display from
Amperes to Volts.
4./ Set by rotating “Hot Start” knob between 30%-50% of the full scale.
5./ Set Arc Force knob to maximum.
6./ Ensure that the Brazing Gun is plugged into the positive terminal and the Earth is plugged
into the negative Terminal.
7./ Fire off several test Brazing Pins in accordance with the Pin Brazing Gun Operation
manual. If required make necessary adjustments using the Output Current and/or the Hot
Start knob. Do not set output Current higher than 245 amperes.
8./ Once the Brazing Pins are firing to the required standard make a note of the settings for
future reference.