BAGNODESIGN BAGNOSPA BDD-SPA-GEN9-3-A User manual

BDD-SPA-GEN9-3-A
BAGNOSPA STEAM GENERATOR 9KW 380V50HZ WITH DIGITAL CONTROL
PANEL, BLUETOOTH MUSIC BOX, 2X SPEAKERS, WIFI BOX AND 4 RGB LIGHTS
www.sanipexgroup.com

GEN9-3
Cataloge
Prologue------------------------------------------------------------------------------1
Users instruction---------------------------------------------------------------------1
Choosing a right location------------------------------------------------------------1
Installation drawing of the steam generator---------------------------------------2
Installation of pipeline------------------------------------------------------------3-4
Blueprint for the steam engine-----------------------------------------------------5
Electric requirements---------------------------------------------------------------6
Installation of the top light----------------------------------------------------------7
Choose your type of machine-------------------------------------------------------8
Maintenance of the steam engine--------------------------------------------------8
Configuration of steam generator--------------------------------------------------9
Cleaning of the steam generator---------------------------------------------------10
Cleaning process---------------------------------------------------------------------11
Trouble shooting---------------------------------------------------------------------11
Common troubles trouble shooting methods-------------------------------------12
Ampere Meter-----------------------------------------------------------------------13
Technical parameter----------------------------------------------------------------14
Figure(Heating element and Power line assemble illustration)---------------15-19

!
GEN9-3
Users instruction
!
We are not responsible for the malfunction and damage came from the installation
that not comply to the users manual.
1. Make sure the model and the accessories are correct, include the voltage input.
2. Make sure the steam power are matched with the sauna room' dimension. Pay much
attention to the steam room's cubage and construction. If you have any problem, please
refer to the Page 11 about the dimension selection.
3. Make sure to read this manual carefully for the secure and effective use.
4. We shall not be responsible for the product damage or malfunction caused by self-
installation or the operation procedures which is not operated by the users instructions.
5. GEN9-3 series are packaged with a case, please check the goods when it arrived to assure it
is in good condition, if you find any damage in the package, please contact the
transportation company or the supplier to claim for compensation.
6. This product must be used indoor.
Install an exhaust fan outside of the steam room in case that it can expel the
excessive steam from the shower room.
Some locations recommended to customers for the right installation.
1.The distance to the steam room less than 6m, the standard pipe which link the controller and
the steam generator should be 6.5m.
2.The steam generator should not be installed in the steam room
3.Not installed outdoor or in any places that will influence the security of the machine by the
environment.
4.Do not install it in the frigid loft or any places the water will freeze.
5.Do not install it near the burnable and caustic object or chemical(coal gas or dope
thinner etc.)
6.Installed in a dry place and the ventilation is good.
Choosing a right location
Welcome to use GEN9-3 series stream generator,this series contains a
steam furnace and a controller. You can adjust the temperature of the sauna room and
set the working time of the steam as you wish. And the system contains a
overheat/dry-burnt protection system and a security valve could
prevent the overheating and assure the steam furnace working at a regular air
pressure. It has the reasonable design and working very stable,very convenient
to install, healthy and comfortable,is the top grade sauna equipment for
the modern family, hotel,restaurant,meeting place and the clubhouse will be satisfied
with the noticeable effects on pain relief,weight control,skin stimulation and
stress reduction due to an increased blood circulation got from steam bath.
GS08M series in clued 9 types o f machines th at output
power varies in 4.5kW,6kw, 9kw, the users could choose it according to their
requirements.
Prologue
Important:

!
GEN9-3
7. Stable and horizontal.The steam generator has a hanging groove for immobility on wall. Make
sure the machine is steady and horizontally installed.
8. On both sides and the top of the steam generator need to reserve at least 12 inches space.
9. The place where the machine is installed must be easily cleaned up and convenient for the
disassembly of the machine.
10. The installation place must be convinent for the drain of water in inner pot.
11. The steam tube,safty valve, drain valve,water tube,steam outlet are still very heated after
the steam generator have stopped working for some time.Must take some measures for example
using the heat insulation tube to prevent the damage of the hot tube and keep the outlet
away from the people.
12. The controller must be installed in the steam room,please refer to the
chapterinstruction of the controller's installation and operation of the manual.
The steam generator(including the controller) are comply with the CE and UL
certificate, and are adaptive in the moisture environment.
!
Installation drawing of the steam generator
Attention:
The drawing is only for
explanation. As for practical design
of steam room, please consult with
qualified designer or architect.
Attention:
Control
panel
Supply
Steam
Outlet
Water
Inlet Pipe
Steam
generator
Water Drain
Valve
Steam
outlet
pipe
Pressure
relief valve
Manual
water drain

Installation of pipeline:
!
Warning: The installation of all the pipes should be operated by qualified plumbers with
corresponding operation certificate in accordanceance with national requirements:
1. Use joints when connecting pipes.
2. Use brass pipes or copper hoses only.
3. Do not use black and galvanized or PVC pipes.
Water supply pipe (1/2'')
1. Connect hot water or cold water pipes. It had better be hot water pipe with a temperature no
more than 70°C.
2. Install stop valve in the water supply pipe. The stop valve should be installed in a place where it is
easily operated in emergency.
3. Clean the water supply pipe completely before connecting the water pipe to the steam engine.
4. It is suggested that filter and anti-furring equipment in the water supply pipe.
5. The water pressure should be at best between 15 and 20 pounds/square inch. If necessary,
decrease the pressure accordingly.
6. If necessary, install equipment to prevent the water producing sound.
Steam pipe (4.5kW pipe size:1/2''; 6kw & above:3/4'')
1. Do not install any valves in the steam pipes. The steam can never be obstructed.
2. Install a brass steam pipe(4.5kW pipe size: 1/2''Ј6kw & above:3/4'') between the steam outlet
and the steam nozzle.
3. The heat insulation material used to insulate the steam pipe should be resistant to temperature as
high as 120°C or higher.
4. The horizontal part of the steam pipe should be installed inclining to the steam outlet or in the
direction of steam engine. Do not bend it in a hape to make sure that the cooled water will not
stay in the curved pipe of the steam pipe.
5. The shorter the steam pipe, the better. Try to decrease the number of elbows and avoid abrupt
turns.
!
Attention: Do not install the steam pipe in an upper or lower direction now and then, which will affect
the output of steam.
Steam nozzle (4.5kW pipe size: 1/2'' Ј6kw & above:3/4'')
!
Attention: Since the steam nozzle and steam outlet are very hot, try to avoid install the steam
nozzle in the position which will easily come into contact with the person in a bath in case the steam
should splash to scald the user.
1. Install the steam nozzle in the position 6-12 inches above the ground. If the steam bath is in the
bathtub or bathroom, install the steam nozzle 6 inches above the bathtub. If the steam room
above adopts materials like acryl or non-heat-resistant sheet, install additional heat insulator.
2. The steam spray outlet should be installed face down. Wind a few circles of green material belt
around the whorl of the steam pipe, install the steam nozzle and tighten with hands.
!
Attention: In order to protect the steam nozzle, do not use the spanner or other tools to tighten,
use a little soap water and soft sponge to wipe, and do not use erosive chemical solutions or crude
cleaning tool.

!
Important:
1. Please consult your distributors of building materials like acryl, fiber glass or other anti-heat
sheet about the installation position of steam nozzle.
2. In the entire steam room, it is required that steam can not leak out. The pipes, its accessories
and the holes in the wall should be air proof by applying air proof glue so that no steam will
enter the holes in the wall.
If non-heat-resistant material like acrylic
is used as building material, reserve a gap
no smaller than 1/4'' and fill with
heat-insulated material.
Airproof green material belt
Use airproof silicon gel or
or r e s p o n d i n g a i r p r o o f
material to fill in the gaps in the
wall to achieve the water-proof
and damp-proof effect. Inside wall in the steam room
Drainpipe (1/2'')
According to national or local rules, the steam engine drainage valve should be equipped with drainpipe.
The steam engine drains the water by using weight.
!
Attention: The drainpipe should not incline upwards so as to facilitate the drainage of water.
Safety valve
1. Safety valve is a piece of safe equipment in order to prevent too much steam pressure in the
interior steam engine due to various reasons.
2. The pressure limit range of safety valve is 15 PSI and the pressure will begin to decrease if
pressure should come over this value.
3. If it is allowed by local codes, provide the safety valve with exterior drainpipe.
!
Warning:
1. Do not dismantle the pressure decrease valve at random in case any danger should happen.
2. To maintain the proper and automatic operation of safety valve, make sure the safety valve
connection pipe is smooth.
GEN9-3

GEN9-3
Blueprint for the steam engine
4.5KW
264.5mm
372mm
6KW/7.5KW/9KW
372mm
264.5mm
333mm
372mm
162mm
333mm
372mm
200mm
Safety valve
Steam outlet
Water inlet
Water drain
162mm
333mm
Manual water
drain
200mm
333mm
Water inlet
Safety valve
Steam outlet
Manual
water drain
Water drain
!
provided is limited, do not operate on the pipeline and electric equipment arbitrarily as shown
in the figure for proportion.
Caution
: To avoid damage to the equipment, do not connect strong electric current
directly to the components
To facilitate maintenance, keep the steam engine clean. If the information
Attention
:
!

GEN9-3
Electrical requirements:
Electricity supply circuitry:
1. Test the voltage of electricity supply and make sure steam engine with suitable electric
voltage should be used..
2. Insulated copper wire should be used with an anti-heat temperature of 90℃ and a specified
voltage of 500V. Refer to national or local electricity consumption code for the
specifications. Refer to the ammeter for the ampere.
3. Choose steam engine with suitable item number, and plug the ground wire into the ground
terminal.
4. Install an independent circuit breaker between the power supply and the steam engine so as to
provide an electricity supply with overflow protection and electricity leakage protection.
!
All the connection must be in accordance with national and local electricity
consumption code and be installed by professional electricians.
Attention:
Installation of the top light
Light is available in 12V/220V/230V outputs. Before connect to the light, please consult with
manufacturer to know what voltage the light is, so as to avoid generator damage or cause
danger.
If the light output is 12V, the power of the light should not be more than 35W,othwise,
transformer will be burned and cause danger. If light input is 220v~240V,light power
should not more than 100W.
The light should be installed on the top of the steam room or the places where are not
access to the children.
OO N N I T
!
I U
A
T C U A C
The illustration is just for explaination, the practical installation must comply
with the nation's electric criterion,and processed by the professional
!
The steam control panel
(Possible location)
The steam
generator
Light
T
he steam outlet
The steam place under
the wash parr (Possible
location)
!
CAUTION:
CAUTION:
Take some moisture proof measures in process of installation.
Can not let the electrical components be exposed to moisture or, it will cause
damage or short circuit.
CAUTIO N:

Choose your type of machine
!
Important:
The calculation formula for selecting the type of steam engine is for
reference only. Due to the variability of the building, the specifications and size
illustration are used as guidelines only. If we have complete information, including actual
blueprint, project instruction and building details, we can select the type of machine
once again. Otherwise, the manufacturer will not be responsible for the selection of
the type of machine.
Measure the length, width and height (foot) of the current steam shower or bathtub room.
Example;
L:7xW:5xH:8 = 280 Cubic Feet
You would need Model s-900 (it is that simple)
However, if you shower materials are;
ADD 75%
ADD 75%
ADD 75%
ADD 75%
A:Natural Stone(Granite or Marble etc.)
B:Exterior walls
C:Celia Heights exceeding 8 FT.
D:Ceramic tile
E:Glass (2 walls) ADD 75%
!
1. Wait for the completion of automatic water discharge after each time of using the steam
engine to make sure the water in the tank is discharged completely before cutting off
power supply.
2. There should not be any leakage or damage among the steam engine, steam nozzle,
components and pipes. They should be checked and repaired annually.
3. Clean the water supply pipes of the steam engine once a year.
4. Check all the connections, faucets and connection terminal to see whether they become
loose or are damaged due to overheat.
5. Check the furring accumulated in the water tank and electric heating tube. If the
furring is thick, dispose it in time (use diluted lemon acid to soak for 15-30 minutes).
6. Remove the water level sensory needle once a quarter to clean the furring in the needle.
Maintenance of the steam engine
Important: Perform water discharge operation after each use.
GEN9-3

1
3
5
11
10
14
13
16
9
9KW
2
4
6
18
12
17
15
8
Configuration of steam generator
GEN9-3
1Exclosure
2Insulation bracket
3Circuit board
4Steam Outlet
5Pressure relief valve
6Water fill valve
7Water drain valve
8 Subsidiary water tank
9Main water tank
10
Heating Element
105OC Hi-limit
Transformer
11
12
Terminal block
Fuse
Earth wire connector
16
17
15
14
13
18
Relay
Water level sensor
Manual water drain
7

Cleaning of steam generator
GEN9-3
Manual cleaning
1. Before cleaning the water tank, please be sure to drain water inside tank completely.
2. Power off the steam generator, put some oxalic acid (crystal state) via steam outlet, for example,
GEN9-3 9KW water tank need about 220g oxalic acid with 500-800ml hot water; pls be sure that
the manual water drain ball valve switch off this time.
3. After putted the oxalic acid inside tank, get power supply to steam generator but no turn it on.
Pressing Fly shuttle button for 2seconds, system will enter into the cleaning procedure, water will
fill the water tank automatically. TEMP window on panel shows “hot”, 59 minutes countdown time
begins and show on Timer window. steam generator will heat up water inside water tank two times
in this period automatically and get water scale peeling off, when from element and water tank.
When timer window shows countdown time is “00:00”,TEMP window shows “opl” from “hot”, pls
switch on the manual drain ball valve at this time to drain the water from water tank. When system
detect lack of water for 1 minute,system will switch on the water inlet valve to get water supply to
water tank so as to continue cleaning water scale inside tank for 1 minute and drain water from
manual water ball valve. After finishing cleaning, system quite the cleaning mode automatically.
When TEMP window shows “opl”, if you don't switch on the manual water drain ball valve, the
control panel keeps waiting till the ball valve switch on or press the power on/off to quit cleaning
function.
4. Water tank of steam generator should be cleaned in every 3 months, if the water is hard, suggest
to clean it every 2 months so as to extend the lifespan of heating element and water tank.
5. The cleaning water must be drained through manual water drain ball valve, otherwise, scale will
jam the Auto. water drain valve.

GEN9-3
Cleaning process
Make sure no water in water tank
Dissolve the oxalic acid with hot water
put oxalic acid via steam outlet
Open the cleaning mode and wait
OPL shows on screen, switch off the
manual water drain ball valve
Finish cleaning
Trouble Shooting
E0: The temperature sensor open circuit.
Water level sensor failure, checking the control cable connection between the control panel to
steam generator is loose or not.
E02: The temperature sensor is Short circuit
E03: Signal transfer fault between main panel and sub-panel .
E04: Signal transfer fault between control panel and steam generator.
E12, E22, E32, E42: water inlet takes over 2 minutes
E13, E23, E33, E43: water inlet tank block.
E15, E25, E35, E45: Auto. high limit trips.

Common troubles trouble shooting methods
To facilitate your use and maintenance of sauna room, the following common troubles trouble
shooting methods are listed for identification.
Troubles Causes of troubles Trouble-shooting methods
The machine does
not start when
electrified
1. The fuse is burned.
2. The wire connection terminal
become loose.
3. Not good contact in the connection
wire between the controller and the
steam engine.
1.
Change the fuse (on the shell 0.8A/ 250V)
2.
Plug tight the wire connection terminal
3.
Make sure the steam engine and the
controller come into good contact
Electricity leakage
switch
breaks
automatically
1. The wire connector is dampened
or damaged.
2. The heating tube breaks
1. Check whether the wire connector is
dampened or damaged, and dry with
dryer if dampened.
2. Change a heating tube.
When the machine is
started, hot water
comes out with little
or no steam
1. The water drainage valve is broken. 1. hange a water drainage valve.
The display screen
on the control panel
does not display
1. The power wire is not connected
well or not in good contact. The
connection plug between the
control panel and the electrically-
controlled box becomes loose.
2. Trouble with plugboard.
1. Check whether the connection plug
between the control panel and the
electrically-controlled box has become
loose, and whether the power circuitry
has good contact.
2. change a plugboard.
Water leakage
1. The water pipe connector becomes
loose or the pipe breaks
2. Water leakage in the water input
valve or the water drainage valve
1. Tighten the loose connector, and change
the broken pipe.
2. Change the water input valve or the
water drainage valve.
No steam when
starting the
machine
1. No electricity.
2. No water.
3. The set temperature is too low
4. Trouble with wire.
1. Check the power supply
2. Check the water input pipe and water
input valve
3. Reset the temperature
4. Contact the distributor
The steam does not
come out, the water
sounds in the
machine
1. The steam pipe is jammed. 1. Cut power supply to check whether
the steam pipe is smooth.
The light can not
be turned on
The display box
displays normally
with no steam
input
1. Too much pressure inside the steam
engine, so the system breaks for
heat protection.
2. Wire is broken for heat protection.
1. Check the steam transport pipe and
restore automatically after heat
protection becomes cool.
2. Check the heat protection wire to make
sure the connection is good.
1. The fuse is burned.
2. The light is broken
3. The wire is broken
4. The plug does not have good contact
1. Change the fuse (on the shell 1A/250V)
2. Change a light bulb.
3. Change wire.
4. Cake the contact good.
GEN9-3

Ampere Meter
Type
Applicable
space of the
room (m3)
Electricity supply Specifications for
power wire
Max. Electric
current (A)
GEN9-3
GEN9-3-4.5KW 12# or 4.0mm2
20.5A
220-240V (1PH/2PH)
4 7
27.3A
16.7A
9A
220-240V (1PH/2PH)
GEN9-3-6KW
GEN9-3-9KW
5 8
10 12
41A
25A
13.7A
208 V (3PH)
380-415V (3PH)
220-240V (1PH/2PH)
208V (3PH)
380-415V (3PH)
10# or 6.0mm2
12# or 4.0mm2
12# or 2.0mm2
8# or 8.0mm2
12# or 4.0mm2
12# or 2.0mm2
The data provided above are for 220-240V(1PH/2PH), 208V(3PH) and 380-415V(3PH).
Within the eyeshot of the steam engine, install an independent circuit breaker so as to provide an
electricity supply with overflow protection and electricity leakage protection.
Important:
The list above is for reference only. In actual checking and repairing, based on
the national and local codes, ask professional service personnel to operate.
Technical parameter
Steam Volume
ml/min
Steam Production Time
(S)
TYPE GEN9-3
Power Output
Potency Error
Duration
Resistance
Steam Pressure
Applicable space of the
room (m3)
Water Tank Volume
4.5KW
±10%
>1500V
>20MΩ
0.12Pa
160
180-240
2.5L
4~7
6KW
±10%
>1500V
>20MΩ
0.14Pa
180
150-220
3.5L
5~8
7.5KW
±10%
>1500V
>20MΩ
0.14Pa
220
140-200
3.5L
7~9
9KW
±10%
>1500V
>20MΩ
0.14Pa
260
130-190
3.5L
10~12
10.5KW
±10%
>1500V
>20MΩ
0.16Pa
300
200-260
7.5L
12~14
12KW
±10%
>1500V
>20MΩ
0.16Pa
360
180-240
7.5L
14~16
15KW
±10%
>1500V
>20MΩ
0.16Pa
450
150-240
7.5L
18~20
18KW
±10%
>1500V
>20MΩ
0.16Pa
500
130-190
7.5L
20~24

Figure(Heating element and Power line assemble illustration)
1
1
4
2
Black
3.0mm²
N
L
3
2
3.0mm²
2.0mm²
2.0mm²
Yellow
Red
Red
Black
Red
Yellow
3.0mm²
3.0mm²
3.0mm²
3.0mm²
2.0mm²
12:30
01
Light
12V~/5-20W
Color Light
12V /10W
G B VCC R
Control Panel
Music box
WIFI box
Sub-Control
Panel
Horn2
Horn1
aroma pump
Temp2
Temp1
25 c
Real timeReal time
Internal wiring diagram of steam generator
4.5kw(220-240V/1phase)
!
I
m
p
o
r
t
a
n
t
:
The parameter listed in the table will be varied from different place and
temperature,please consultate to the qualificatory designer and architect for the more
detailed use.

GEN9-3
Figure(Heating element and Power line assemble illustration)
12:30
01
Control Panel
Music box
WIFI box
Sub-Control
Panel
Horn2
Horn1
Temp2
Temp1
25 c
Real timeReal time
Internal wiring diagram of steam generator
6kw(220-240V/1phase)
1
1
4
2
Black
2.0mm²
N
L
3
2
2.0mm²
2.0mm²
2.0mm²
Yellow
Red
Red
Black
Red
Yellow
2.0mm²
2.0mm²
2.0mm²
2.0mm²
2.0mm²
Light
12V~/5-20W
Color Light
12V 10W
G B VCC R
aroma pump
3
4
2.0mm²
2.0mm²

GEN9-3
Figure(Heating element and Power line assemble illustration)
12:30
01
Control Panel
Music box
WIFI box
Sub-Control
Panel
Horn2
Horn1
Temp2
Temp1
25 c
Real timeReal time
Internal wiring diagram of steam generator
7.5-9kw(220-240V/1phase)
1
1
6
2
Black
2.0mm²
N
L
3
2
2.0mm²
2.0mm²
2.0mm²
Yellow
Red
Red
Black
Red
Yellow
2.0mm²
2.0mm²
2.0mm²
2.0mm²
2.0mm²
Light
12V~/5-20W
Color Light
12V 10W
G B
VCC R
aroma pump
3
4
2.0mm²
2.0mm²
5
6
4
5
2.0mm²
2.0mm²
2.0mm²
2.0mm²
copper short
circuit board

1
4
3
2
2.0mm²
2.0mm²
2.0mm²
2.0mm²
2.0mm²
GEN9-3
Figure(Heating element and Power line assemble illustration)
12:30
01
Control Panel
Music box
WIFI box
Sub-Control
Panel
Horn2
Horn1
Temp2
Temp1
25 c
Real timeReal time
Internal wiring diagram of steam generator
6-9kw(380-415V/3phase)
1
2
Black
2.0mm²
N
L1
L2
L3
2.0mm²
2.0mm²
2.0mm²
Yellow
Red
Red
Black
Red
Yellow
2.0mm²
Light
12V~/5-20W
Color Light
12V 10W
G B VCC R
aroma pump
3
4
2.0mm²
2.0mm²

Note:

IND-SPA-GEN9-3-A-12-21
www.sanipexgroup.com
Table of contents
Other BAGNODESIGN Iron manuals