Balboa EL1500 v35 User manual

Page 1 EL1500 - 40916_01_C
EL1500 Tech Sheet
40916_01_C.pdf 04/24/2009
Template used: 4091
6
_01_C.pdf 04/24/2009
Software Version # 35
EPN # _____
Base PCBA – PN ______
PCB EL1500 – PN 22075 Rev B
HEX File – __________
Configuration Signature – __________
Base Panels
MLM990H – PN 54526
MLM990S – PN 54527
ML900 – PN 52654
ML700 – PN 52649
ML551 – PN 53502
ML550 – PN 53392
ML400 – PN 52684
ML260 – PN 53566
ML240 – PN 53643
ML200 – PN 52685
Aux Panels
AX40 – PN 54527
AX10-X
_____________
System PN ________
System Model # E2P-______-_CA_
EL1500 Tech Sheet v35 Template
This is not a shippable model.
This document template is merely a
starting point for custom models.
Customer;
Configuration Method (Check One)
N/A DIP Switch Configured
Software Configured
Configuration Signature ______________
See last page for Panel and
Overlay selection.
Main Panel PN ________
Main Panel Overlay PN ________
Aux Panel PN ________
Aux Panel Overlay PN ________
Optional Custom Box Overlay (Circle One)
- No
- Yes, Overlay PN _______
Redlines created by: _____________
Date: _____________

Page 2 EL1500 - 40916_01_C
System Revision History
System PN EPN Date Requested By Changes Made
This page is for listing the changes made to this system and will be filled in as the tech sheet are
created/updated.
This will provide a quick reference of what was changed from one system version to the next.

Page 3 EL1500 - 40916_01_C
Basic System Features and Functions
Setup 1 (As Manufactured)
s 60UMP3PEED
s 60UMP3PEED
s 60UMP3PEED
s 6"LOWER3PEED
s 6#IRC0UMP
s 6/ZONE
s 63PA,IGHT
s 6&IBER/PTIC,IGHTAND7HEEL
s 6AV (Stereo)
s 6K7(EATER
(EATERWATTAGEISRATEDAT67HENRUNNING6TOHEATEROUTPUTISAPPROXIMATELY
Power Requirements
s
6!#(Z!#LASS!'&#)PROTECTEDSERVICE#IRCUIT"REAKERRATING!MAX
s ORWIRESnHOTHOTOPTNEUTRALGROUND
System Outputs
A
J6
J7 J8 J13
J44
J60 J22
1 SP. EXT. RLY
TST
AUX. F
SEN. A SEN. B
W10
VAC
J48
J
17
GC
W
7
2-SP
EXT RLY
FUSE 20A 250V
K8
K9
F8
GC
GC
J20
J29
J12
J47
W2
J69
J70
W3
FUSE 3A 250V
F1
GC
U4
K5 J71
ADCM
MAIN
PANEL
MAIN ML PNL
REMOTE
CFG
J1
J2
J45
J82
J3
Additional Options
s &ULL&EATURE$OLPHIN2EMOTE
and Spa-only Dolphin Remote
s 3PA-ONITOR
Connects to Main Panel terminal J70 or J71
s )2OR2&$OLPHIN2ECEIVER-ODULE
Connects to Remote terminal J20
s !UXILIARY0ANEL#ONNECTIONS*AND*
s /ZONE'ENERATOR
Connects to terminal J29 or J17
s -OOD%&8,IGHTING
Connects to Spa Light terminal J12
s 3TEREO3YSTEM
Connects to A.V. terminal J50
s 2EAL4IME#LOCKOPTIONPLUGSINTO*
System Outputs (Circle Configurations)
Pump 1 240V 120V 1-Speed 2-Speed Disabled
Pump 2 240V 120V 1-Speed 2-Speed Disabled
Pump 3 240V 120V 1-Speed N/A Disabled
Pump 4 240V 120V 1-Speed N/A Disabled
Blower 240V 120V 1-Speed ___-Speed Disabled
Circ Pump 240V 120V N/A N/A Disabled
Ozone 240V 120V N/A N/A Disabled
Spa Light 12V 120V N/A N/A Disabled
Audio/Visual 240V 120V N/A N/A Disabled
Mister 240V 120V N/A N/A Disabled
Heater 240V 120V 5.5kW 4.0kW ____kW
Software Configured
Service - Input Power Requirements (Circle Letter Assignment)
Y
6!#(Z!#LASS!'&#)PROTECTEDSERVICE#IRCUIT"REAKERRATING!MAXWIRESHOTHOTNEUTRALGROUND
D
6!#(Z!#LASS!'&#)PROTECTEDSERVICE#IRCUIT"REAKERRATING!MAXWIRESHOTHOTNEUTRALGROUND
Z
6!#(Z!#LASS!'&#)PROTECTEDSERVICE#IRCUIT"REAKERRATING!MAXORWIRESHOTHOTOPTNEUTRALGROUND

Page 4 EL1500 - 40916_01_C
Persistent Memory and Powering Up
!NYTIMEYOUCHANGE$)03WITCHESOR3OFTWARE#ONFIGURATION3ETTINGSTHAT
affect parameters the user can change (any filter settings, set temperature
default, Celsius vs Fahrenheit, 12-hour vs 24-hour time, reminders
SUPPRESSIONETCYOUMUSTRESET0ERSISTENT-EMORYFORYOUR$)03WITCH
or Software Configuration Settings changes to take effect. You should also
reset Persistent Memory after loading a new file into a board (using the ESM,
purchased seperately).
To reset Persistent Memory:
s0OWERDOWN
s3ET!/.3EEILLUSTRATIONBELOW
s0OWERUP
s7AITUNTILh vORh ” is displayed on your panel.
.OTE)Fh ” appears see section below.
s3ET!/&&4HISCANBEDONESAFELYWITHPOWERONIFYOUUSEA
nonconductive tool such as a pencil to push the switch back to the OFF
position. Otherwise, power down before setting A12 OFF)
s0OWERUPAGAINIFYOUPOWEREDDOWNINTHEPREVIOUSSTEP
s&ORALLOTHERPOWERUPSLEAVE!/&&
About Persistent Memory and Time of Day Retention:
This system uses memory that doesn’t require a battery to store a variety
OFSETTINGS7HATWEREFERTOAS0ERSISTENT-EMORYSTORESALLTHE5SER
Preferences, as well as all the filter settings, the set temperature, and the heat
mode.
Persistent Memory is not used for Time of Day. Time of Day needs to be
hKEPTRUNNINGvNOTJUSTSTOREDWHILETHEPOWERISOFFSOANOPTIONAL2EAL
Time-Clock (RTC) board keeps track of Time-of-Day while the unit is off.
Time-of-day retention, and time-of-day retention alone, is controlled by the
RTC Board. This board should be installed on any system that uses a control
panel that displays time-of-day. The RTC Board must be removed from any
system that does not have a panel installed that supports time-of-day.
message on power up:
)Fh vAPPEARSBEFOREANDINSTEADOFh ” or
hvYOUHAVENOTCONFIGURED$)03WITCHESANDOR
Software Configuration Settings in a valid manner. This must be corrected
before you can reset Persistent Memory.
4HESWITCHNUMBERSJUMPERSORCONFIGURATIONSETTINGSDISPLAYEDAFTER
h” are ones with which the system has found a configuration problem.
For example:
s h ” would mean that the combination of how you’ve
set A5 and how you’ve set B2 is not supported on this system.
s h vWOULDMEANTHATTHEREISAPROBLEMWITHJUMPER*
sh ” would mean that the combination of how
you’ve set pump 3 for 1-speed and blower for 1-speed is not supported on
this system.
s h ” would mean that the combination of how
YOUVESET$)0SWITCHESWHICHHAVEBEENASSIGNEDTOPUMPANDBLOWERIS
not supported on this system.
Power Up Display Sequence
5PONPOWERUPYOUSHOULDSEETHEFOLLOWINGONTHEDISPLAY
s 4HREENUMBERSINAROWWHICHARETHE33)$THE3YSTEM3OFTWARE)$
The third display of these numbers is the Software Version, which should
match the version of your system. For example, if these three numbers are
, that is a Mach 3 EL8000 at version 26.
s )FTHEREISA#ONFIGURATION%RRORTHE message (see above) will
appear at this point (and none of the messages below will display).
Otherwise what comes next is:
s !NINDICATIONOFEITHERTHEINPUTVOLTAGEDETECTED%,OR
THEHEATERWATTAGERANGESUPPORTED%,',',',
Heater wattage display:h ” means the system supports a heater
FROMK7TOK7h ” means the system supports a heater
FROMK7TOK7h vMEANSTHESYSTEMSUPPORTSAK7
heater only. (These ranges may be modified slightly in the case of special
heaters, which the next bullet covers.)
Input voltage display: !SYSTEMSHOWINGh vSUPPORTSK7
TOK7HEATERS!SYSTEMSHOWINGh ” supports the very same
heaters, although at 120V those heaters will function at only 1/4 of their
6RATEDWATTAGE4HESYSTEMSHOWSONLYEITHERh vORh
” as a general indication of input voltage; it does not show the
actual input voltage.)
s )FYOURSYSTEMISUSINGASPECIALTYPEOFHEATERADISPLAYSUCHAS
hvMAYAPPEARNEXT)FYOURSYSTEMISUSINGTHEGENERIC"ALBOAHEATER
no heater type display will appear.
s h vORh ” will appear to signal the start of
Priming Mode.
!TTHISPOINTTHEPOWERUPSEQUENCEISCOMPLETE2EFERTOTHE5SER'UIDE
for the ML Series panel on your system for information about how the spa
operates from this point on.
J
6
J7
J8
J1
3
J
44
J
6
0
J
2
2
1
S
P. EXT. RLY
TST
C
F
G
A
UX.
F
S
EN. A
S
EN. B VA
C
J
1
J
2
7
2-
S
P
E
XT
R
L
Y
K9
J
2
0
J
45
W2
J
69
J
7
0
U
4
K5
J
71
AD
C
M
MAIN
PAN
E
L
MAIN
ML
PNL
R
EM
O
T
E
J
8
2
J
3
Configuration
Settings
Enabled
RTC
Real-Time
Clock Board
Optional Real-Time-Clock board
plugs into J3.

Page 5 EL1500 - 40916_01_C
T
OR
Q
UE
RAN
G
E
F
O
R TB1
:
27-30 IN. LB
S.
H
OT
BLA
CK
NEUTRAL
W
HITE
H
O
T
R
ED
K6
K
1
3
K
4
K2
K3
W
HT A
C
B
LK A
C
J
6
1
J
62
J
1
1
J
6
6
J
65
J
1
5
J
16
J
2
5
J
63
J
6
4
C
LA
SS
G
F
USE 30
A
F5
T
B1
H
TR
2
HTR1
J
101 F
2
J
10
0
B
a
l
boa
SWITCHBANK
A
S
1
J
6
J7
J8
J1
3
J
44
J
6
0
J
2
2
E.GN
D
1
S
P. EXT. RLY
TST
C
F
G
A
UX.
F
S
EN. A
S
EN. B
W
1
0
VA
C
R
ED A
C
J
32
J
33
J
34
J
36
J
3
7
J
35
T1
FUS
E .3A 250V
F4
E
L1500
P
/N 22075_B
CO
PYRIGHT 2008
G
C
K1
J
1
J
2
J
2
3
J
74 J48
J
46
W
1
J
5
0
J
17
G
C
W4
G
C
W7
2-
S
P
E
XT
R
L
Y
FUSE 20A 250V
K
8
K9
F8
G
C
G
C
J
2
0
J
45
J29
J
47
W2
J
69
J
7
0
W3
FUSE 3A 250
V
F1
G
C
U
4
K5
J
71
AD
C
M
MAIN
P
AN
E
L
MAIN
ML
PNL
R
EM
O
T
E
J
8
2
J
12
J
3
For 120V Systems,
DIP A2 and A3 must be OFF
and Jumper Wire added.
5.5kW
Heater rated @ 240V
(Approx. 1.4kW @ 120V)
Audio VisualAudio Visual
Do not remove Fuse F8 (20A)
12V
Light
G
R
B
W
J
1
W1
J7
J6
F
30A 480
V
X
-P33
2
P
N
5513
7
P/
N 22909 REV
B
Not Used
Ozone
Configuration
Settings
Enabled
2-Spd P1
Real-Time
Clock Board
NOT Installed
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
s 60UMP3PEED
s 60UMP3PEED
s 6"LOWER3PEED
s 6#IRC0UMP
s 63PA,IGHT
s 6/ZONE
s 6!<6(Stereo)
s 6K7(EATER
s -,-AIN0ANEL
Switchbank A
A4, Filters by Time
A6,
A5,
A8,
A9, Filter Duration 2 hr.
A7,
A11, Special Amp Rule OFF
A12, Memory ON
A10, No Edit
When the Logic Jumper is installed on J82 (CFG),
Software Config. Settings are enabled.
DIP Switches will operate as shown.
}
See Table 2
Circ Behavior
Pumps w/Heat
See Table 1
}
See Table 3
Pump 2
}
CFG
J2
J82
100
114
35
SSID #
120 Volt Connections
240 Volt Connections
Black AC Jumpers
12 Volt Connections
Relay Control Wires
Wiring Color Key
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
1
2
3
4
Board Connector Key
WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING: Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)
Indicate DIP positions needed for this system.
Special Connections/Notes:________________
________________________________________
________________________________________
Expander Boards (Select configuration)
Device Ex Board Model Voltage
Blower (2/3-Spd) X-B 120V
Pump 3 - 1 Spd X-TB 240V
Pump 4 - 1 Spd X-P
Mister X-P231
ADCM Splitter X-P332
Cables\Adapters
PS-34
HOzone on J17
HOzone on J29
HInclude Real-Time Clock capability

Page 6 EL1500 - 40916_01_C
DIP Switches and Jumpers Definitions
WARNING:
sSetting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
sContact Balboa if you require additional configuration pages added to this tech sheet.
DIP Switchbank A Key
A1 .............Test Mode (normally Off)
A2 .............See Table 1
A3 .............See Table 1
A10 .............When switched ON when spa is on, system will enter the Edit Menu
for Configuration Settings. Do not start spa with A10 turned on or CFE* error will occur
A11 .............
In “ON” position, enables Special Amperage Rule, see "SA" in Software
Configuration section for functionality with your system
..............In “OFF” position, disables Special Amperage Rule
A12 .............Persistent memory reset (used when spa is powering up) See "Persistent Memory and Powering Up" page
*CFE errors are illegal configurations such as a pump and a blower set to run on the
same output. The configuration must be corrected before the spa will operate.
Assignable DIP Switch Key
A4 .............
In “ON” position, Filter cycles are programmed by duration
..............In “OFF” position, Filter cycles are programmed by time
A5 and A6
........
See Table 2 for Circ Pump Behavior settings
A7 and A8
........
See Table 3 for Pump 2 Behavior settings
A9 .............
In “ON” position, Filter cycles duration is 3 hours
..............In “OFF” position, Filter cycles duration is 2 hours
Table 2 Circ Pump
A5 A6 Behavior
OFF OFF Non-circ
OFF ON 24-hour
ON OFF 24-hour w/3˚F
ON ON Like Pump 1 low
Table 1 # of Hi-Speed
Pumps/Blower
Before Heat Disabled
A2 A3
OFF OFF 0
ON OFF 1
OFF ON 2
ON ON Up to 4
Table 3 Pump 2
A7 A8 Behavior
OFF OFF No Pump 2
OFF ON 1-Spd Pump 2
ON OFF 2-Spd Pump 2
on X-P332
ON ON 1-Spd Pump 2
on X-P332
Software Configured
To be filled is as individual system requires.

Page 7 EL1500 - 40916_01_C
Output Features Quadrant
J23 + W1 – 2-Speed Pump 1 4-A
– OR 1-Speed Pump 1 when in Circ Mode
J50 + W4 – Audio Visual - always hot, no relay 6-A
J17 + W7 – 1-Speed Blower (W3 to J46) 6-A
– OR Single-Speed Pump 2 or Pump 3 (W3 to J62)
– OR Ozone (W3 to J46)
J47 + W2 – Circ Pump 8-A
J29 + W2 – Ozone (Same voltage as Circ Pump, if used) 9-A
– Note X-03 option board for retro fit
J12 – Spa Light (12V only) 9-A
Note: Some panels styles are not available depending on system
configuration. Consult your Balboa product representative for details.
Other Features Quadrant
J3 – Real-time Clock Board can be installed 8-D
– Allows programming by time of day
– Stores time settings for 30 days without power
120V Conversion Option - Add jumper from Red AC (J32) to
White AC (J11) and set DIP switch A10 to ON.
X-Mount P
5SEDFORMOUNTINGANY%XPANDER"OARD
INAPLASTICENCLOSURE
3TANDOFFSATTACHTOHEATERMOUNTINGBRACKET
PN 53933
A
B
C
D
E
A
B
C
D
E
123456789
123456789
TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.
HOT
BLACK
NEUTRAL
WHITE
HOT
RED
K6
K13
K4 K2
K3
WHT AC
BLK AC
J61 J62
J11
J66 J65
J15 J16 J25 J63 J64
CLASS G
FUSE 30A
F5
TB1
HTR2 HTR1
J101 F2
J100
Balboa
SWITCHBANK A
S1
J6
J7 J8 J13
J44
J60 J22
E.GND
1 SP. EXT. RLY
TST
AUX. F
SEN. A SEN. B
W10
VAC
RED AC
J32 J33 J34
J36 J37
J35
T1
FUSE .3A 250V
F4
EL1500
P/N 22075_B
COPYRIGHT 2008
GC
K1
J23 J74 J48
J46
W1
J50 J17
GC
W4
GC
W7
2-SP
EXT RLY
FUSE 20A 250V
K8
K9
F8
GC
GC
J20
J29
J12
J47
W2
J69
J70
W3
FUSE 3A 250V
F1
GC
U4
K5 J71
ADCM
MAIN
PANEL
MAIN ML PNL
REMOTE
CFG
J1
J2
J45
J82
J3
RED AC
PS-23
5SEDTOSPLITTHEOUTPUTFROMA3PEED#ONNECTORINTOA
SINGLESPEED0UMPANDSINGLESPEED0UMP7HITEWIRE
QUICKCONNECTGOESTO2ED!#OR7HITE!#ON-AIN0#"
PN 25089
Pump 3 Pump 2
To J1
on X-P332
White
Red
White
Green
Black
Green
To RED AC or WHITE AC
on Main PCBA to set Pump 3 Voltage
Configuration Options

Page 8 EL1500 - 40916_01_C
Expander Options
X-P
Used for a 1-speed Pump output.
s*ON80CONNECTSDIRECTLYTO"LACK!#USING*OR*
ONTHEMAIN%,0#"!
s*ON80CONNECTSTO*ONTHEMAINBOARD
s7ON80CONNECTSDIRECTLYTO2ED!#6OR
7HITE!#6ONTHEMAIN%,0#"!
X-P231
#ANREPLACETHE80INCASESWHEREBRANCHCIRCUITPROTECTION
ISNEEDEDFORHIGHAMPERAGEDEVICESTHATWOULDOVERBURDEN
POWERINPUTFUSE&!ONTHEMAIN0#"!
s*ONTHE80CONNECTSDIRECTLYTO"LACK!#BY
USING*OR*ONTHEMAINBOARD"
s#ONNECT*WIREONTHE80TOJ13ONTHEMAINBOARD%
s#ONNECT7ONTHE80TO2ED!#6OR
7HITE!#6ONTHEMAINBOARD
PN 53544
PN 53681 X-P332
5SEDFORANADDITIONALSPEED0UMPOUTPUT
s*ONTHE80CONNECTSDIRECTLYTO"LACK!#BY
USING*OR*ONTHEMAINBOARD"
s#ONNECT*WIREONTHE80TO*ONTHEMAIN
BOARD%
s#ONNECT7ONTHE80TO2ED!#6OR
7HITE!#6ONTHEMAINBOARD
#ANALSOBEUSEDWITHA03CABLE0.
TOCONTROLTWOSPEED0UMPS
PN 55137
0.?!
G
C
J6
J4
J2
W12
K1 G
C
J6
J3
J2
W12
K1
F10A 250V
F5
X-B
5SEDFORA3INGLE3PEED"LOWEROUTPUT/.,9
s*ON8"CONNECTSDIRECTLYTO"LACK!#
USING*OR*ONTHEMAIN%,0#"!!
s*ON8"CONNECTSTO*%ONTHEMAINBOARD
s7ON8"CONNECTSDIRECTLYTO2ED!#6OR
7HITE!#6ONTHEMAIN%,0#"!
PN 53310
G
RBW
J1
W1
J7
J6
T30A 480V
X-P231
PN 53681
P/N 22909 REV B
G
RBW
J1
W1
J7
J6
T30A 480V
X-P332
PN 55137
P/N 22909 REV B
X-TB
5SEDFORAMULTISPEED"LOWERREQUIRESVSOFTWAREANDhB,vSETTOhvORhv
/RCANBEUSEDFORASPEED"LOWER
s7CONNECTSTO2ED!#6OR7HITE!#6ON-AIN0#"!
s*CONNECTSTO*OR"LACK!#ON-AIN0#"!!
s*CONNECTSTO*%ON-AIN0#"!
PN 55344
G
RBW
J1
J3
J2
W1
RED/WHT
BLK/12VAC-A
PN 22051_A 2006
BLOWER
F1
Pb
Balboa
C

Page 9 EL1500 - 40916_01_C
Program Filter Cycles by Duration nY
n=Start and stop times; for time capable panels.
Y=Duration; for non-time capable panels =1 DIP Switch
Pump 1 in Filter (w/Circ Pump) nY (This feature is used in Circ Mode only.)
Allows Pump 1 Low to operate in Filter Cycles to add extra filtration.
n=Normal; Y=Pump 1 with Circ
24-Hour Time* nY
n=12-hour (am/pm); Y=24-hour (military\European); =
1 DIP Switch
*Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Celsius** nY
n=Fahrenheit; Y=Celsius; =1 DIP Switch
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up
Timeouts 1 F2 3 4 5 6
1-6 = 10, 20, 30, 40, 50, 60 minutes; F=15 minutes
Pump 1 Low Timeout d 1 23 4
d = Use “Timeouts” value above; 1-4 = number of hours; =
3 DIP Switch
Light Timeout d 1 2 3 4
d = Use “Timeouts” value above; 1-4 = number of hours
Scrunch Panel nY
n=Normal panel layout;
Y=Alternate panel layout (ML900 scrunching enabled - ML550/700
Jets 3 replaces Blower;
=1 DIP Switch
Circ Type (behavior) nA 3 P
n=Non circ or circ pump not plumbed with heater; A=24-hour;
3=24-hour with 3ºF shutoff outside filter;
P = Acts like Pump 1 Low (filter cycles, polls, etc.); =2 DIP Switch
Software Configuration Settings
OEM Setting (Green circle)
n =

Page 10 EL1500 - 40916_01_C
Pump 1 Speeds 1 2
1=1 speed; 2=2 speed; =1 DIP Switch
Pump 2 Speeds 01 2 E
0=Disabled; 1=On/Off on main board; 2=2 speed on X-P332 Board;
E=On/Off on X-P or X-P231; =2 DIP Switch
Pump 3 Speeds 0E H Y
0=Disabled; E=External X-P or X-P231 board;
H=On/Off on pin 1 of X-P332 board;
Y=On/Off on pin 2 of X-P332 board; =3 DIP Switch
Pump 4 Speeds 0Y
0=Disabled;
Y=On/Off on pin 2 of X-P332 board;
=
3 DIP Switch
Blower Speeds 01 2 3
0=Disabled; 1=On/Off on main board; 2=2 speeds on X-TB board;
3=3 speeds on X-TB board; =2 DIP Switch
Mister 1 nY
n=Disabled; Y=On/Off on X-P or X-P231 board; =1 DIP Switch
Mister 2 nY
n=Mister Disabled;
Y=Mister Enabled on pin 1 of X-P332 board; =1 DIP Switch
Mister 3 nY
n=Mister Disabled;
Y=Mister Enabled on pin 2 of X-P332 board; =1 DIP Switch
Software Configuration Settings Continued
PUMP SPEEDS

Page 11 EL1500 - 40916_01_C
Option 1* nY P
n=Disabled; Y/P =Enabled on J17; = 2 DIP Switch
Option 3* nY P
n=Disabled; Y/P =Enabled on pin 1 of X-P332 board; = 2 DIP Switch
Option 4* nY P
n=Disabled; Y/P =Enabled on pin 2 of X-P332 board; = 2 DIP Switch
*Note: Options 3-4: Y = On/Off w/ no timeout (toggle) mode; P = Pulse (momentary) mode
Cleanup Cycles** 01 2 3 4
0=Disabled; 1-4 =Number of hours
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Cleanup Cycles as User Preference
nY
n=Only in Configuration Settings;
Y=Over-rideable by User via User Preferences
Ozone Operation AF
A= Operates with Heater Pump (Pump 1 Low or Circ Pump);
F = Operates in Filter and Cleanup Cycles only; =1 DIP Switch
Ozone Suppression nY
n=No Suppress; Y=1-hour suppress on button press; =
1 DIP Switch
Ozone Icon n Y
n=O3Icon on Panels Disabled; Y=O3Icon on Panels Enabled
Ozone Location ob
o=Ozone on J29 (Shares relay with Circ Pump in Circ Mode.)
b=Ozone on J17 (Neither a 1-Spd Blower or 1-Spd Pump 2 can be used.)
Software Configuration Settings Continued
OZONE OPTIONS

Page 12 EL1500 - 40916_01_C
Software Configuration Settings Continued
REMINDERS AUXILIARY BUTTONS
Aux Button 1 (Bank A) 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Aux Button 2 (Bank A) 1 23 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Aux Button 3 (Bank A) 1 2 3 4 5 6 bg F E o t d P n A U r O H 9 L 8 7
Aux Button 4 (Bank A) 1 2 3 4 5 6 b g F Eo t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
Aux Button 1 (Bank B) 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Aux Button 2 (Bank B) 1 23 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Aux Button 3 (Bank B) 1 2 3 4 5 6 bg F E o t d P n A U r O H 9 L 8 7
Aux Button 4 (Bank B) 1 2 3 4 5 6 b g F Eo t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
Aux Button Bank Select Ab
A=Bank A; b=Bank B; =1 DIP Switch
Suppress all Reminders n Y
n=Display Reminders; Y=Suppress all Reminders; =1 DIP Switch
Check pH Reminder Period 0 12 3 4 5 6 7 8 9 t
Check Sanitizer Reminder Period 0 12 3 4 5 6 7 8 9 t
Clean Filter Reminder Period 0 1 2 34 5 6 7 8 9 t
Test GFCI Reminder Period 0 1 2 34 5 6 7 8 9 t
Drain Water Reminder Period 0 1 2 3 4 5 67 8 9 t
Change Mineral Cartridge 01 2 3 4 5 6 7 8 9 t
Clean Cover Reminder Period 0 1 2 3 4 5 6 7 89 t
Treat Wood Reminder Period 0 1 2 3 4 5 6 7 89 t
Change Filter Reminder Period 0 1 2 3 4 5 6 7 8 9t
0 = Off; 1 = 7 days; 2 = 14 days; 3 = 30 days; 4 = 45 days; 5 = 60 days; 6 = 90 days;
7 = 120 days; 8 = 180 days; 9 = 365 days; t= 21 days

Page 13 EL1500 - 40916_01_C
Lowest Set Temperature* 87
8 = 80˚F/26.0˚C; 7 = 70˚F/21.0˚C
*Setting LS at 7 and Fr at 5 will cause a CFE error.
Default Set Temperature** 5 6 7 8 9 01 2 3 4 E F n
5 = 95˚F/35.0˚C; 6 = 96˚F/35.5˚C; 7 = 97˚F/36.0˚C; 8 = 98˚F/36.5˚C; 9 = 99˚F/37.0˚C; 0 = 100˚F/38.0˚C;
1 = 101˚F/38.5˚C; 2 = 102˚F/39.0˚C; 3 = 103˚F/39.5˚C; 4 = 104˚F/40.0˚C; E = 80˚F/26.5˚C; F = 85˚F/29.5˚C
n = 90˚F/32.0˚C
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Uppermost Set Temperature 5 6 7 8 9 0 1 2 3 4E F n
5 = 95˚F/35.0˚C; 6 = 96˚F/35.5˚C; 7 = 97˚F/36.0˚C; 8 = 98˚F/36.5˚C; 9 = 99˚F/37.0˚C; 0 = 100˚F/38.0˚C;
1 = 101˚F/38.5˚C; 2 = 102˚F/39.0˚C; 3 = 103˚F/39.5˚C; 4 = 104˚F/40.0˚C; E = 80˚F/26.5˚C; F = 85˚F/29.5˚C
n = 90˚F/32.0˚C
Freeze Temperature Threshold 3 49 5
3 = 39˚F
/3.9˚C
; 4 = 44˚F
/6.7˚C
; 9 = 49˚F
/9.4˚C
; 5 = 54˚F
/12.2˚C
;
Set Temperature Lock tS
t=Temp Lock Only; S=Temp + Settings Lock
Software Configuration Settings Continued
TEMPERATURE SETTINGS

Page 14 EL1500 - 40916_01_C
Light Cycle Programming nY
n=Disabled; Y=Enabled
Filter 1 Start Hour (Set 1)* -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 1 Duration (Set 1)* -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Start Hour (Set 1)* -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Duration (Set 1)* -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
-= Standard Defaults; 0= 0 (12 am, 24); 1-9 = 1-9; A= 10; b= 11; C= 12; d= 13 (1 pm); E= 14 (2 pm);
F= 15 (3 pm); g=
16 (4 pm);
H= 17 (5 pm); J= 18 (6 pm); L= 19 (7 pm); n= 20 (8 pm); o= 21 (9 pm);
P= 22 (10 pm); r= 23 (11 pm)
These settings allow customization of the filter defaults. If any of these four settings is "-", the standard filter
defaults are used. 1d and 2d cannot both be set to 0.
When Fd.n is selected, 1d and 2d are Filter 1 and Filter 2 Duration specifically.
When Fd.y is selected:
If 1d is set to 0, 2d is the duration; otherwise 1d is the duration.
If 1d is set to 0, only the Night cycle runs.
If 2d is set to 0, only the Day cycle runs.
If neither 1d nor 2d is set to 0, both the Day and Night cycles run.
*Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Filter 1 Start Hour (Set 2)** -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 1 Duration (Set 2)** -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Start Hour (Set 2)** -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
Filter 2 Duration (Set 2)** -0 1 2 3 4 5 6 7 8 9 A b C d E F g H J L n o P r
-= Standard Defaults; 0= 0 (12 am, 24); 1-9 = 1-9; A= 10; b= 11; C= 12; d= 13 (1 pm); E= 14 (2 pm);
F= 15 (3 pm); g=
16 (4 pm);
H= 17 (5 pm); J= 18 (6 pm); L= 19 (7 pm); n= 20 (8 pm); o= 21 (9 pm);
P= 22 (10 pm); r= 23 (11 pm)
These settings allow customization of the filter defaults. If any of these four settings is "-", the standard filter
defaults are used. 3d and 4d cannot both be set to 0.
When Fd.n is selected, 3d and 4d are Filter 1 and Filter 2 Duration specifically.
When Fd.y is selected:
If 3d is set to 0, 4d is the duration; otherwise 3d is the duration.
If 3d is set to 0, only the Night cycle runs.
If 4d is set to 0, only the Day cycle runs.
If neither 3d nor 4d is set to 0, both the Day and Night cycles run.
**Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Filter Default Start Time Set*** 12
1= Set 1; 2= Set 2; = 1 DIP Switch
***Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Filter Default Duration Set* 12
1= Set 1; 2= Set 2; = 1 DIP Switch
*Sets default for user preferences - only applies when persistent memory is reset (A12 On) during power-up.
Software Configuration Settings Continued
FILTER CYCLES

Page 15 EL1500 - 40916_01_C
Software Configuration Settings Continued
PURGE DURATION
Pump Purge Duration 3 12 5 t
3= 30 seconds; 1-5= 1 - 5 minutes; t = 10 minutes
Blower Purge Duration 5 1 2 34 6 t F
5 = 5 seconds; 1= 10 seconds; 2= 20 seconds; 3= 30 seconds;
4= 45 seconds; 6= 60 seconds (1 minute); t= 2 minutes; F= 5 minutes
Mister Purge Duration 51 2 3 4 6 t F
5 = 5 seconds; 1= 10 seconds; 2= 20 seconds; 3= 30 seconds;
4= 45 seconds; 6= 60 seconds (1 minute); t= 2 minutes; F= 5 minutes

Page 16 EL1500 - 40916_01_C
Remote Button 1 (Set A) 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 2 (Set A) 1 23 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 3 (Set A) 1 2 34 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 4 (Set A) 1 2 3 4 5 6 bg F E o t d P n A U r O H 9 L 8 7
Remote Button 5 (Set A) 1 2 3 4 5 6 b gF E o t d P n A U r O H 9 L 8 7
Remote Button 6 (Set A) 1 2 3 4 5 6 b g FE o t d P n A U r O H 9 L 8 7
Remote Button 7 (Set A) 1 2 3 4 5 6 b g F E ot d P n A U r O H 9 L 8 7
Remote Button 8 (Set A) 1 2 3 4 5 6 b g F E o td P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
1
12
54
45
23
678
DOLPHIN REMOTE
ROUND REMOTE
Remote Button 1 (Set B) 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 2 (Set B) 1 23 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 3 (Set B) 1 2 34 5 6 b g F E o t d P n A U r O H 9 L 8 7
Remote Button 4 (Set B) 1 2 3 4 5 6 bg F E o t d P n A U r O H 9 L 8 7
Remote Button 5 (Set B) 1 2 3 4 5 6 b gF E o t d P n A U r O H 9 L 8 7
Remote Button 6 (Set B) 1 2 3 4 5 6 b g FE o t d P n A U r O H 9 L 8 7
Remote Button 7 (Set B) 1 2 3 4 5 6 b g F E ot d P n A U r O H 9 L 8 7
Remote Button 8 (Set B) 1 2 3 4 5 6 b g F E o td P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
1
12
54
45
23
678
DOLPHIN REMOTE
ROUND REMOTE
Remote Button Bank Select Ab
A=Bank A; b=Bank B; =1 DIP Switch
Software Configuration Settings Continued
REMOTE BUTTONS SET AREMOTE BUTTONS SET B

Page 17 EL1500 - 40916_01_C
ML90x Custom Button 1 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 2 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 3 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 4 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 5 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 6 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 7 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML90x Custom Button 8 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
ML90x Series
1234
8765
Ti
me
WarmWarm
Mode
e
C
oo
l
ML90x Custom Buttons Enable nY
n=Disabled; Y=Enabled; = 1 DIP Switch
ML75x/MX75x Custom Button 1 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML75x/MX75x Custom Button 2 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML75x/MX75x Custom Button 3 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML75x/MX75x Custom Button 4 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML75x/MX75x Custom Button 5 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML75x/MX75x Custom Button 6 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
ML75x Series
MX75x Series
654
123
Ti
me
Warm
m
m
W
W
Mode
e
e
C
oo
l
ML750/MX750 Custom Buttons Enable
nY
n=Disabled; Y=Enabled; = 1 DIP Switch
Software Configuration Settings Continued
ML75X/MX75XSERIES BUTTONS ML90XSERIES BUTTONS

Page 18 EL1500 - 40916_01_C
ML70x Custom Button 1 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML70x Custom Button 2 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML70x Custom Button 3 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML70x Custom Button 4 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
ML70x Series
43
12
Ti
me
WarmWarm
Mode
e
C
oo
l
ML70x Custom Buttons Enable nY
n=Disabled; Y=Enabled; = 1 DIP Switch
ML55x Custom Button 1 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML55x Custom Button 2 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML55x Custom Button 3 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML55x Custom Button 4 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
ML55x Custom Button 5 12 3 4 5 6 b g F E o t d P n A U r O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled; r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir; 7 = Option 5
ML550
ML551/
ML554
1
123
5234
45
ML553
1
3
4
C
oo
l
C
oo
l
C
ool
W
arm
WarmWarm
Warm
Warm
M
o
d
e
Mode
e
Mode
e
ML55x Custom Buttons Enable nY
n=Disabled; Y=Enabled; = 1 DIP Switch
Software Configuration Settings Continued
ML70XSERIES BUTTONSML55XSERIES BUTTONS

Page 19 EL1500 - 40916_01_C
ML40x/ML2xx Custom Button 1 12 3 4 5 6 b g F E o t d P n A Ur O H 9 L 8 7
ML40x/ML2xx Custom Button 2 12 3 4 5 6 b g F E o t d P n A Ur O H 9 L 8 7
ML40x/ML2xx Custom Button 3 12 3 4 5 6 b g F E o t d P n A Ur O H 9 L 8 7
1-6 = Assigns Pump Number (Pump 1, Pump 2, etc); b = Blower; g = Spa Light; F = Fiber-Optic wheel/light;
E = EitherLight;
o = Option 1; t = Mister 1; d = Mister 2/Cool; P = Mister 3/Elec Heat; n = Ext Heat; A = Sound Mode Select;
U = Button Disabled (DO NOT USE); r = Air Valve; O = Option 2; H = Option 3; 9 = Invert; L = Option 4; 8 = Stir ; 7 = Option 5
ML400
12 3
ML200
321
ML260
321
ML240
321
TempTemp
TempTemp
TempTemp
TempTemp
ML40x/ML2xx
Custom Buttons Enable
nY
n=Disabled; Y=Enabled; = 1 DIP Switch
Special Amperage Rule* 12 3 4
1=Blower off when 2nd high-speed pump on; 2=Max 1 high-speed pump
3=Max 2 high-speed pumps;
4=Max 2 high-speed pumps + Blower off when 2nd high-speed pump on
*Note: DIP A11 must be ON to use Special Amperage Rule.
DR Mode nY
n=Disabled; Y=Enabled
Demo Mode nY
n=Disabled; Y=Enabled
GFCI Test Enable n1 2 3 4 5 6 7
n= Disabled; 1= Auto after 1 day; 2= Auto after 2 days; 3= Auto after 3 days; 4= Auto after 4 days;
5= Auto after 5 days; 6= Auto after 6 days; 7= Auto after 7 days
Software Configuration Settings Continued
ML40X/ML2XX SERIES BUTTONS

Page 20 EL1500 - 40916_01_C
Ozone Connections
W10 J48
J46
J50 J17
GC
W4
GC
W7
FUSE 20A 250V
K8
K9
F8
GC
GC
J29
J12
J47
W2
J70
W3
FUSE 3A 250V
F1
GC
K5 J71
MAIN
PANEL
MAIN ML PNL
CFG
J1
J45
J82
Use this slot for the leftover Red conductor
Line - Black conductor
Balboa Ozone connector configuration for 120V 60Hz
Ground (Green) conductor
Flat sides of sockets as shown
Common - Install the White conductor here for 120V ozone
Use this slot for the leftover White conductor
Line - Black conductor
Balboa Ozone connector configuration for 240V 60Hz
Ground (Green) conductor
Common - Install the Red conductor here for 240V ozone
B
G
B
G
Use this slot for the leftover conductor
Line - Black conductor
Ground (Green) conductor
Common - Red for 240V or
White for 120V ozone (See W2 wire)
W2 wire determines voltage
Ozone Connector Voltage: The EL circuit board is factory configured to deliver a preset voltage (120V
or 240V) to the on-board ozone connector (J29 or J17). See the ratings table on the wiring diagram
attached to the cover of the enclosure for the configured voltage and output connector. For 240V output,
W2 (J29) or W7 (J17) connects to Red AC. For 120V output, W2 or W7 connects to White AC.
The voltage to the ozone connector can be changed in the field if required. W2 or W7 just need to be set
for the required voltage.
Balboa Ozone Generator: If the board is set up to operate a 120V ozone generator, the connector on the
ozone generator is likely to be configured correctly, but should be compared to the illustration below.
If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the
connector next to the green ground wire as described below.
Note: A special tool is required to remove the pins from the connector body once they are snapped in
place. Check with your Balboa Account Manager for information on purchasing a pin-removal tool.
Table of contents
Other Balboa Water System manuals
Popular Water System manuals by other brands

flamco
flamco Logotherm LogoFresh XL-Line Installation and operating instruction

Water Protec
Water Protec LED 13 owner's manual

Filtrete
Filtrete 4US-MAXS-S01 Installation and operating instructions

Conel
Conel CLEAR 2.0 RD 1.5 operating instructions

Monitor
Monitor MFH-5398 instructions

Zip
Zip HydroTap G5 Touch-Free Wave installation instructions

Condair
Condair RO-U Installation, operation and maintenance

WaterLogic
WaterLogic WL3FW user manual

Carrier
Carrier 50YA Installation and start-up instructions

Kemper
Kemper FK-5 installation instructions

Energie
Energie EcoTop Stainless 250i owner's manual

Reclaim
Reclaim REHP-CO2-160GL Owners & installation manual