Baltech VP-3410 User manual

OPERATION MANUAL
Version 03
BALTECH
VP-3410
VIBRATION METER

CONTENT
1
1. Introduction .............................................................2
1.1.Appliedconventions.......................................................2
2. Requirements of security measures...........................3
3.Technical description.................................................3
3.1. Assignment.................................................................3
3.2. Technical characteristics................................................3
3.3. Structure of vibration meter...........................................5
3.4. Structure and functioning of vibration meter...................5
3.4.1. General principles of operation...................................5
3.5. Marking and packing.....................................................6
4. Commission of vibration meter.................................7
4.1. Operation conditions of vibration meter...........................7
4.2. Setting-up procedures...................................................7
4.2.1. Unpacking and exterior check of xture.......................7
4.2.2. Sensor installation......................................................7
4.2.3. Power supply connection............................................8
4.3. Application of vibration meter.........................................8
4.3.1. Measurement mode...................................................8
4.3.2. Choice of interval for frequency range.........................9
4.3.3. Execution of measurements......................................10
5. Maintenance support .............................................10
5.1. Replacement of batteries..............................................10
6. Storageandtransport..............................................11
7. Warranty liabilities..................................................12
8. Acceptance and packing certicate..........................13
9. Training....................................................................14

2
INTRODUCTION
The present operation manual (OM) is intended to introduce to
a user an application, structure, operation principle, operation
instructions, measurement procedure, safety requirements and
requirements to transportation and storage of vibration meters
BALTECH VP-3410.
All employees of BALTECH GmbH want our users to be satised
with operation of purchased xtures around here. That
is why, if required in the event of any questions connected
with operation of vibration meter, do not hesitate to contact
specialists of BALTECH GmbH.
1.1. Applied conventions
Conventions given below are used in this operation manual to
emphasize the associated text.
1
NOTE
Paragraphs emphasized with word Note contain special
comments or instructions.
ATTENTION
Paragraphs emphasized with word Attention alerts you about
actions, which could cause minor injuries and inuence on
the system.

REQUIREMENTS OF SECURITY
MEASURES
• Do not use the xture if there are any damages of its
units or parts.
• Apply vibration meter only its intended purpose.
TECHNICAL DESCRIPTION
3.1. Assignment
Vibration meter BALTECH VP-3410 is designed to perform
vibration measurement of a wide range of machines for the
purpose of checking their technical condition.
The vibration meter is a simple, portable measurement xture,
which allows to perform the following tasks:
•measurement of acceleration;
•measurement of velocity;
•measurement of displacement.
3.2. Technical characteristics
Technical characteristics of vibration meter BALTECH VP-3410
are given in the Table 3-1. Table 3-1
Measurement range of acceleration, m/s2 Pk from 1 to 199,9
Measurement range of velocity, mm/s RMS from 1 tо 199,9
Measurement range of displacement (amplitude),
mkm Pk-Pk from 1 tо 1999
Frequency range, Hz:
At measurement of acceleration from 10 to 1000;
from 1000 to 10000
At measurement of RMS velocity from 10 to 1000
At measurement of displacement from 10 to 500
2
ATTENTION
Nonobservance of requirements of security measures may
result in serious injury, death or failure of the xture. For this
purpose please follow
3
3

4
Absolute expanded uncertainity,
unit of measurement, up to:
Via measuring circuit of acceleration (on
frequency reference 160 Hz) and velocity
(on frequency reference 80 Hz)
±2 dgt
±(0,05 × x)
Via measuring circuit of displacement (on
frequency reference
45 Hz)
±2 dgt
±(0,06 × x)
где x – measured
value of vibration
characteristics
Deviation of xture reading within the range of operation
frequency from reading on frequency reference, %, up to:
Via measuring circuit of acceleration within
the range from 12,5 to 1000 Hz and from
1000 to 1000 Hz
±5
Via measuring circuit of velocity within the
range from 12,5 to 800 Hz ±5
Via measuring circuit of velocity on
frequencies 10 Hz and 1000 Hz -10
Via measuring circuit of displacement within
the range from 12,5 to 500 Hz -15; +5
Change of reading depending of
temperature within operation range of
temperatures, %/10oC, up to
3
Operation conditions:
Temperature range, oCот 0 до 50
Outside dimensions
(length, width, height), mm 138 × 68 × 30
Weight, g 270

3.3. Structure of vibration meter
The delivery set is listed in the Table. 3-2. Table. 3-2
№Name Qty
1 Measurement unit 1
2Vibration sensor with cable and
magnet clamp and chip shield 1
3 Battery, 9V, type D 1
4 Operation manual 1
5 Packing 1
3.4. Structure and functioning
of vibration meter
3.4.1. General principles of operation
The vibration meter BALTECH VP-3410 consists of electronic
unit and piezoelectric acceleration sensor (further piezosensor).
Piezosensor is connected to the xture via cable (Pic. 3-1).
The xture case is made of ABS plastic and has one sensor input
for sensor and display, reecting changes and current settings.
5
1. Electronic unit
2. Piezosensor
3. Magnet clamp
4. Cable
5. Chip shield
Рiс. 3-1. Visual appearance of vibration meter BALTECH VP-3410
4.
5.
2.
1.
3.
Measurement and setting
control is performed with
buttons of membrane
keyboard on the front side
(Picture 3-2). Battery is inside
the case in a battery pack.

Рiс. 3-2. Front panel of vibration meter BALTECH VP-3410
3.5. Marking and packing
Marking of xture is made in the form of the nameplate on the
back side of electronic unit. On the nameplate it is indicated the
name of xture, power supply, capacity, article, serial number
and name of manufacturer.
Рiс. 3-3. Appearance of vibration meter BALTECH VP-3410
Packing of the xture is done in special cartoon.
6
1. Display
2. ON/OFF
3. Choice of measurement mode
4. Change of frequency range

COMMISSION OF VIBRATION METER
4.1. Operation conditions of vibration meter
• environmental temperature, °С - from 0 to +50
• relative humidity at 25 °С: to 95%
4.2. Setting-up procedures
4.2.1. and exterior check of xture
To unpack the xture you just need to draw it out of the
packing cartoon.
Before starting the measurements it is necessary to make
exterior check of the xture on absence of mechanical damages
and contaminations.
To check the delivery set of the xture according to division 3.3.
«Structure of vibration meter».
In the presence of contaminations it is necessary to make
technical service according to division 5 of the present OM.
7
4
ATTENTION
In the presence of any mechanical damages please make
sure that they do not inuence on xture reading, otherwise
send the xture for repair.
4.2.2. Sensor installation
Vibration meter BALTECH VP-3410 uses an acceleration sensor,
which is connected to the electronic xture with a help of low-
noise cable.
Sensor installation on the object is done with the help of magnet
clamp, shipped with the sensor.
The place of installation need to be cleaned
and put consistent lubricant for resonance
lowering. (Pic. 4-1)
Рiс. 4-1. Sensor with magnet clamp

4.2.3. Power supply connection
Just press the measurement button to switch on the fixture.
(Pic. 4-2)
Рiс. 4-2. Switching on the power supply
4.3. Application of vibration meter
Before making measurements make sure that the battery is not
discharged. If it is necessary, change the battery according to
division 5.1.
4.3.1. Measurement mode
Press the button «A•V•S» for the choice of measurement mode
(Pic. 3-2): acceleration, velocity or displacement. Selected
measurement mode is indicated by arrow in the right part of the
screen. (Pic. 4-3).
8
ATTENTION
Before sensor installation it is necessary to remove chip
shield.
ATTENTION
Before operation please make sure that the sensor rmly
connected to magnet clamp.
NOTE
The vibration meter switches off automatically in a minute
without pressing the button of measurement.

9
Рис. 4-3. Indicator of measurement mode
4.3.2. Choice of interval for frequency range
While measuring of acceleration it can be used button of change
for frequency range «HI*Lo» (Pic. 3-2). Selected frequency
range will be indicated by arrow in the left part of the screen.
(Pic. 4-4).
Рiс. 4-4. Indicator of range (HI/Lo*)
*- where HI: 1 kHz -10 kHz is used for measurement of high-frequency vibration.
Lo: 10 Hz-1 kHz is used for measurement of common vibration.
А-Аcceleration
V-Velocity
S-Displacement
Measurement
mode indicator
NOTE
The choice of frequency range is possible only for
measurement of acceleration.
Other manuals for VP-3410
1
Table of contents
Other Baltech Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Powerfix Profi
Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot
Test Equipment Depot GVT-427B user manual

Fieldpiece
Fieldpiece ACH Operator's manual

FLYSURFER
FLYSURFER VIRON3 user manual

GMW
GMW TG uni 1 operating manual

Downeaster
Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments
Hanna Instruments HI96725C instruction manual

Nokeval
Nokeval KMR260 quick guide

HOKUYO AUTOMATIC
HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke
Fluke 96000 Series Operator's manual

Test Products International
Test Products International SP565 user manual

General Sleep
General Sleep Zmachine Insight+ DT-200 Service manual