Beghelli SanificaAria 30 User manual

INSTALLATION, USE AND MAINTENANCE MANUAL
(code 26700)
up to

The UVoxy®technology enables
air sanitization through a closed
chamber system saturated with
UV-C rays: the flow cell UVoxy®
draws in air from the environment and delivers sanitized
air.
In the SanificaAria 30 device, the UV-C chamber size
makes it suitable for small and medium-sized rooms (up
to 50m2).
OPERATION
The sanitization unit
consists of an axial fan
intake system that draws
air inside the closed
chamber containing the
UV-C source, where the
sanitization process takes
place. The UVoxy®
replaceable cartridge
is installed inside of the
module. Replacement is
quick and ensures the
sanitization characteristics
of the appliance are
maintained over time. Use
an original UVoxy® Beghelli
spare part (code 26720).

1
EXAMPLE OF AIR SANITIZATION
Room size
Surface area (m2)
Curvature (m3)
Sanitization time (h)
6
15
0.5
13
30
1
25
60
2
38
90
3
50
120
4
Germicidal effect of the UV-C lamp (ozone-free)
a) Optimal germicidal effect
between 250 and 270nm
b) DNA absorption curve
c) The radiation of a low-pressure
UV lamp consists almost
exclusively of a 254nm
spectral line, which is close to
the maximum germicidal
effect.
Testing and Certification
Test performed according to ISO15714, as applicable, on
sample microorganisms. The test details can be found on
geltinternational.it/technal/beghelli or by scanning the QR
CODE
Device conforming to
European Directives
2014/35/EU and
2014/30/EU.
COMMITMENT TO QUALITY
controlled by Independent Third Parties.
Want to know how?
Scan the QR CODE!

2
DEVICE USE:
Please read the maintenance instructions and
safety warnings carefully before use.
Its compact design and the different installation options
(wall-mounted, suspended, on a support or on a floor
stand with a bracket) make it particularly versatile. Pay
attention not to obstruct the correct air flow.
A B
H
H1
A1 B1
Dimensions mm
Sanitization
rate
A
B
H
A1
B1
H1
100
100
475
152
152
584
30m3/h

3
FLOOR-STAND INSTALLATION
-Take out the 2 screws from the back of the device
-Fix the bracket to the product by tightening the screws
-Connect the power cord to the mains
MOUNTED ON A SUPPORT
- Place the 4 rubber washers on the backside and fix the
device on the support
- Connect the power cord to the mains

4
WALL AND CEILING MOUNTING
- Fix the bracket (A) to the wall (centre to centre
distance:300mm)
- Attach the 2 riders (B) to the device
- Anchor rider B onto the bracket (A) (see detail) and fix
it in screws (C)
A
B
B
A

5
SUSPENDED MOUNTING
- Attach the bracket (A+B) to the device
- Fix the riders (D) in their seats (centre to centre distance:
300mm)
D
A-
B

6
MAINTENANCE
Before cleaning or maintenance, make sure the
device is turned off and disconnected from the
power supply.
CLEANING
Remove the dust that may have built-up on the outer
grids, using a brush.
When replacing the cartridge, remove the dust from the
internal deflectors.
uvOxy® 30 SANITIZING CARTRIDGE REPLACEMENT
Cartridge life: 12 months (continuous use). Replacing the
cartridge allows you to keep the germicidal performance of
the device in time.
The blue indicator light on the front
shows the UV-C lamp is turned on
properly. The lamp should be replaced if
the blue light is no longer lit when the
device is on.
1
3
2

7
- Takeout the 5screws from thebottom of the device (the
middle screwfirst)
- Take out the inside part(singlebody)andremovethecover
- Replace the cartridge only with an original UVoxy®
Beghelli spare part (code 26720)
- Put the cover back on, re-insert the device body into the
housing and tighten the 5 screws (the middle screw last)
SanificaAria 30 TECHNICAL FEATURES
Power supply: 230VAC ± 10%, 50÷60Hz (2m long cable)
Local switch on power cable
Power consumption: 24W
UV-C Lamp: TC 2G11 18W
UV-C wavelength: 254nm
Sanitization rate: 30m 3 /h UV-C
radiant power: 5.5W
Ozone-free UV-C lamp
Cartridge life: 12 months (continuous use). Replacing the
cartridge allows you to keep the germicidal performance
of the device in time.
Noise level: 40dB (A) at 1 meter
Weight: 3.5kg
Degree of protection: IP20
Insulationclass: I (appliance with protective grounding)
Automatic safety microswitch
4

IMPORTANT
SAFETY WARNINGS
- The device contains a UV-C emission lamp.
- WARNING: DO NOT activate the UV lamp when
removed from the protective casing of the appliance.
- This device must only be used for its intended use. Any
other use shall be deemed as nonconforming and
therefore dangerous.
- Usingthedeviceotherwise than as describedherein orifthe
housing isdamaged can result in UV-C radiation leaks.
- Even small doses of UV-C radiation can damage eyes
and the skin.
- Please read the maintenance instructions before
opening the device.
- The device must be turned off and disconnected from
the power supply before replacing the UVoxy® Beghelli
cartridge (code 26720).
- Do not insert small objects into the ventilation grid. They
could damage the fans and impair the device operation.
- If damaged, the device should not be used.
- If dropped from a height, check if the UV-C lamp turns
on correctly (front indicator blue light is on).
- In case of failure or malfunction, do not tamper with the
device. Please contact only an authorized technical
service centre for repairs.
- The device must be used exclusively indoors and not
outdoors. Any other use shall be deemed improper.
8

9
DISPOSAL
The packaging is made out of recyclable materials.
Dispose of it according to environmental protection
regulations, by separate collection.
According to European Directive 2012/19/EU, the
device fallen into disuse must be disposed of in a
compliant manner: It must not be discarded as
unselected municipal waste. It must be taken to recycling
centres or sent back to the Beghelli vendor.
Recyclable materials used in the appliance can be
recovered to avoid environmental pollution.
For more information, please contact your local disposal
authority or the appliance vendor.
- Children mustn't play with the device. Cleaning and
maintenance must not be done by children without adult
supervision.
- Make sure the device is connected to a grounded outlet.

334.901.994
SUPPORT AND WARRANTY
For repairs or spare parts, please contact Beghelli's
authorized customer support department: 800 626626
(toll-free number).
The appliance is covered by the manufacturer's warranty.
All parts found to be faulty due to negligence,
or careless use, failure to comply with operating
instructions, damage during transport or circumstances
that cannot be traced back to manufacturing defects shall
not be covered by warranty. The warranty is also
excluded in all cases of improper use. Failure to comply
with instructions given in this manual for device use, care
and maintenance shall cancel the manufacturer's
warranty.
BEGHELLI S.p.A. - Via Mozzeghine 13/15 - loc. Monteveglio
40053 Valsamoggia (BO) - ITALY - Tel. +39 051 9660411 - Fax +39 051
9660444
Technology tested at Tecnal laboratories
under the supervision of Gelt International.
For information on the effectiveness of cutting
down microbiologic load, scan the QR code or
visit
geltinternational.it/tecnal/beghelliwebsite
FOR
INFORMATION
Toll Free
This manual suits for next models
1
Table of contents
Popular Accessories manuals by other brands

PlaneWave Instruments
PlaneWave Instruments Secure fit CCD Spacer 3.8 Installation

Hama
Hama DS-200 Operating instruction

Philips
Philips SDW5061GN Specifications

Life Giving Warmth
Life Giving Warmth The Cozee user manual

National Instruments
National Instruments FIELDPOINT CFP-CB-1 operating instructions

Altinex
Altinex CNK212 user guide