WARNING
1. Ensure that the installation is in the correct zone and that equipotential bonding is
carried out.
2. The new hose-sets supplied with the appliance are to be used and that old hose-
sets should not be reused.
3.
4. Pay attention to the drop height when go in or out of the appliance, to avoid
stumbling. Watch out the appliance with suds
5. Don't use acidic and strong alkaline detergent, acetone, ammonia and so on.
Clean with alkalescent detergent and soft cloth
6. Put on fluid sealant once it shed, to avoid water leakage.
7. Settings, configurations and details of the products are subject to be changed
or upgraded without prior notice.
8. For the maintenance, please contact the technicians appointed by the dealer and
don't disassemble and fix by yourself, or the supplier will be free from any
consequences that may occur.
This appliance is not intended for use by persons with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge (including children;
people with heart disease or high blood pressure), unless they have been given
supervision or instruction concerning use of the appliance by a person responsible
for their safety. Children should be supervised to ensure that they do not play with
the appliance.
Preparations
02
01
Please use tools to open the packing;
Make sure all accessories are in the packing
Drain 1pcs Handheld shower
hose 1pcs
Accessory Box
Handheld shower 1pcs Waterfall faucet 1pcs Drain cover 1pcs
A: Gradient B: Sealant C: Adjustable spanner D: Thread sealing tape
Installation Tools(no included)

A: Waterfall Faucet
B: Handheld Shower
C: Switch of Handheld Shower and Faucet
D: Water Regulator
E: Water Inlet(Cold/Hot)
04
03
Preparations
780mm
1800mm
450mm
500mm
Drain hole
Cold
Hot
1450mm
Bathtub Configuration
Installation of Electric Appliance
Rated Voltage Rated Frequency Max Rated Power Rated Current
220V 50Hz 2300W 11.5A
1. Electric Parameter
2. There should be creepage protector on the power supply. Earthed appliances must be
permanently connected to the fixed wiring with well protective ground wire.
2
The section of the electrical wire should not be less than 2.5m . The power supply
appliance should be tally with the National Safety Standard. And connect the protective
ground wire to the bathtub frame with groundwire sign (The creepage protector is
prepared and connected by yourself)
Installation of Water Supply
1. Hose Connecting Way
The fittings of bathtub were already connected before shipment. You only need to
connect the cold/hot water hose to the corresponding water supply tube, which should
be in the shadow of the bathtub back.
Water Inlet Faucet Connecting
2. Water Supply Chart
Hot Water
Cold Water
Water Regulator
Switch Valve
Handheld shower
Waterfall Faucet
Preparations
A B CD E
6Handheld Shower
7Back Jets
82# Pump Water Divider
91# Pump Switch
1# Pump Air Regulator
10
2# Pump Switch
2# Pump Air Regulator
Underwater Light Switch
11
12
13
14 Skirt
1Water-Inlet Switch
2Water-Inlet Waterfall
3Water Circulation
4Big Jets
5Bottom Jets
1400mm
500mm
PS: 1# Pump supplies water for big jets; and 2# Pump supplies water for back jets and
bottom jets.

06
05
Installation Process Installation Process
Installation of Bathtub
1. Overturn the bathtub(backside upturned), and wrap the drain hole with Thread sealing
tape. Then fasten the drain tube.
As picture show:
2. As the below picture: Turn back the bathtub. Then Install the water-inlet waterfall and
handheld shower on and connect to the water hose. Move the bathtub to the wall corner.
Put the downcomer into the drain hole. And use sealant around the hole. Adjust the
anchor screw to make the bathtub horizontal.
2# Pump1# Pump
C
Sealant

08
07
Installation Process Installation Process
3. .Seal the gap between the bathtub side and the wall with sealant, to avoid water leakage
Usage
1. Switch on the power supply.
2. Turn on the cold/hot water switch, and adjust to the suitable temperature. Use the switch
to choose the faucet or handheld shower to let water in.
3. Don't press the pneumatic switch unless the water level in the bathtub goes beyond the
jets position.
4. Use air regulator to adjust the massage power.
5. Rotate the handheld shower to adjust the massage effect.
6. Use light switch to turn on/off the underwater light.
7. Adjust the water divider to use back jets or bottom jets. When the divider handle is in the
middle position, you can use both back jets and bottom jets at the same time.
8. Press pneumatic switch, turn off the pumps, and drain the water after use.
9. Turn off the power supply.
Troubleshooting
Trouble Possible Reason Try this to solve
Water pump
Don't work.
Power supply is not well connected,
the creepage protector disconnect .
Turn on the power supply, and connect
the creepage protector.
Clean the water pump impeller.
Water pump impeller was stuck
by sundries.
Press the water pump switch.
The water pump switch is off.
Plug the power supply in.
Power supply plug don't insert or no
enough power supply.
Repair or replace the water pump.
Water pump trouble.
Air pump don't
work.
(this version
include )don't
No enough power supply. Check the circuitry and plug the power
supply in.
Press the air pump switch.
Switch is off.
Plug the power supply in.
Power supply plug don't insert or the
power supply is abnormal.
Massage power
can't be adjusted.
Voltage problem. Check voltage.
Adjust switch is off or has problemis
broken.
Water Circulation is blocked.
Check, replace the switch.
Clean the water circulation.
Bathtub don't
stand horizontally.
Adjustable foot is not well-adjusted. Adjust the Adjustable foot.
Water leakage.
Obturating ring is not good. Replace the obturating ring.
Nut is loose.
Connect part is not well connected.
Screw down the nut.
Pay attention to the connect part
conglutination.

09
Installation Process
Cleaning & Maintenance
1. Use general liquid detergent and soft cloth for daily cleaning. Don't use detergent that
with acetone or ammonia. Disinfector with formic acid and formaldehyde is forbidden
during disinfection.
2. If there is scratch on the bathtub surface, use 2000# waterproof abrasive paper to
polish it and lay toothpaste on. Then use soft cloth to furbish it.
3. Scale deposit can be wiped off with warm citric acid or vinegar by a soft cloth.
4. Screw off the Water Circulation and jets for cleaning when plug up by litter, such as hair
5. Frequent cleaning is not necessary for the parts gilded and silver-gilt
6. Don't clean the tub with hard or coarse material to avoid any scratches; and don't clean
the tub by detergent with chemical menstruum to avoid any damages.
7. Be sure to drain off the water and disconnect the power supply after use
8. Don't hit and score the bathtub by hard or keen-edged material. And don't touch the
bathtub by cigarette end or heat source that over 70
9. Water massage system cleaning: fill the bathtub with 40 hot water, and add
detergent(2g/L). Then run the water massage system for 5 minutes. After that, stop the
pump and drain the water. Fill the bathtub with cold water, and run the water massage
system for 3 minutes. Clean the bathtub after stopping the pump and draining off the
water.
1. The installation should be carried out by a qualified technician, and should be according
to the manual.
2. The appliance electric parameter should be tally with the National Safety Standard. And
there should be creepage protector on the power supply. Make sure the ground wire is
safe. Don't touch the switch, electrical outlet and plug with water.
3. Don't use overheated water. Put cold water first, then hot water. Don't run the appliance
until the water level is higher than the jets.
4. The rated voltage of this appliance is 220V. Don't run it when the voltage is over 235V
or under 190V.
5. Disconnect the power supply after use
6. Don't take a bath for a long time. Recommended time: less than 30 minutes
7. Please restart the appliance for occasional system halt
8. If the supply cord is damaged, it must be replaced by the manufacturer, its service
gent or similarly qualified persons in order to avoid a hazard.
9. This manual is attached with the product. Before installation, please read it carefully. All
he installation and use should conform to this manual, to avoid damage or other accident.
Precautions
Caution:
1. When the bathtub can't work, please check according to the troubleshooting list. If you can't judge
the reason or unable to repair it, please contact the seller or Bellagio Luxury's maintenance center
2. To insure the customers' safety, the installation should be carried out by a qualified technician.
Please use eligible creepage protector. The ground wire should be well connected to the ground.
Table of contents
Other BELLAGIO Bathtub manuals
Popular Bathtub manuals by other brands

Whirlpool
Whirlpool Ariel ARL-702 installation manual

Kohler
Kohler K-1151 Homeowner's guide

American Standard
American Standard 3052OD.X0X Installation instructions and owner's manual

Kohler
Kohler K-1111-H2 Roughing-In Guide

Kohler
Kohler K-1158 Roughing-In Guide

Kohler
Kohler Hourglass K-1209-LA Roughing-In Guide