Bellhowell SONIC BREATHE 8662 User manual

ULTRASONIC PERSONAL HUMIDIFIER
INSTRUCTIONS MANUAL
BELL + HOWELL® SONIC BREATHE ITEM NO.8662
Distributed Under License By EMSON® NY, NY, 10001
©Copyright 2011 EMSON® All Rights Reserved.
BELL + HOWELL® is a registered trademark of BHH LLC.

CONTENTS
IMPORTANT SAFEGUARDS............................................................................................................. 3
PARTS AND FEATURES ................................................................................................................... 7
OPERATION...................................................................................................................................... 9
CLEANING AND MAINTENANCE .................................................................................................. 11
SPECIFICATIONS ........................................................................................................................... 12
2

3
Before using the electrical appliance, the following basic precautions should always
be followed including the following:
1. Read all instructions.
2. Keep humidier out of reach of children.
3. Before use check that the voltage of wall outlet corresponds to the one shown on the
rating plate.
4. Do not operate any appliance with a damaged cord or plug or after the appliance
malfunctions, or is dropped or damaged in any manner. Return appliance to the nearest
authorized service facility for examination, repair or electrical or mechanical adjustment.
5. If the supply cord is damaged it must be replaced by the manufacturer or an authorized
service agent or a qualied technician in order to avoid a hazard.
6. Do not let cord hang over edge of table or hot surface.
7. Do not immerse plug, cord or housing into water due to the risk of electric shock.
8. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
9. Use only bottled bottle, distilled or tap water. DO NOT use sparkling water or the humidier
will not work normally. To avoid white dust, the use of distilled water is recommended.
10. To avoid re or shock hazard, plug into the humidier with AC Adaptor then plug the
humidier direct to a 120 VAC or 240 VAC electrical outlet.
11. Keep AC adaptor out of heavy trac area. To avoid re hazard, NEVER put AC adaptor
under rugs, heater, replace, radiator or stove.
12. The humidier should be at least 6 inches (15 cm) away from the wall for best result.
13. Never place humidier in the area where it is accessible to children.
14. Never use humidier in a closed room, particularly where children may be sleeping,
resting or playing. A closed room might result excessive humidity.
IMPORTANT SAFEGUARDS IMPORTANT SAFEGUARDS
4
SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD USE ONLY.
15. Do not attempt to rell or clean the humidier without rst unplugging the unit from its
electrical outlet. Failure to follow this warning may cause personal injury.
16. Never place anything over mist outlet/nozzle when the humidier is running.
17. Never insert or drop any object into any openings.
18. DO NOT operate humidier with a damaged cord or plug.
19. DO NOT use outdoors.
20. DO NOT ll hot water in the bottle.
21. Always place humidier on a rm, at, level surface. A waterproof mat or pad is
recommended for under the humidier. NEVER place it on rug or carpet, or on a nished
oor that may be damaged by exposure to moisture or water. Bell+Howell will not accept
responsibility for property damage cause by water spillage.
22. DO NOT allow mist outlet/nozzle direct face to the wall. Mist could cause damage,
particularly to wallpaper. Bell+Howell will not accept responsibility for wall or wallpaper
damage cause by mist output.
23. Humidier should be unplugged when not in use.
24. NEVER tilt, move, or attempt to empty water bottle while it is running. Switch o and
unplug from electrical outlet before removing the water bottle and moving the unit.
25. DO NOT use humidier where the humidity level exceeds 50%, excessive moisture
could cause damage.

IMPORTANT SAFEGUARDS IMPORTANT SAFEGUARDS
IMPORTANT:
To improve the eciency of your humidier and reduce the possibility of health hazard, it is
recommended that you take the following precautions:
1. Follow the manufacturer’s recommended cleaning and maintenance instructions.
2. The amount of minerals and impurities in the water source is varied; therefore periodical
cleaning the humidier is necessary.
3. During the heating season, check the lm or scale built up on the humidier and all moving
parts every 2 weeks basis, and establish a proper cleaning schedule.
4. Do not allow lm or scale build up on the humidier or any moving parts, it will reduce the
eciency or life span of the humidier.
5. At the end of winter humidier season, drain and thoroughly clean your humidier as part
of the summer shut down.
Like your heating system or air conditioning unit, periodic cleaning and maintenance are
required to ensure the safe and ecient operation of your humidier.
ACID
5 6

7
PARTS AND FEATURES PARTS AND FEATURES
8
8
7
1
4
2
6
9
1. Bottle Adaptor
2. Mist Nozzle
3. ON/OFF dial (MIN/MAX)
4. Ultrasonic Nebulizer
5. Germicidal UV LED
6. LED Light (Blue)
7. Air Vent
8. AC Adapter Connector
9. Fold-out Feet
10. Cleaning Brush
11. Storage Pouch
12. AC/DC World Travel Adapter
3
10
11
12
5
UNIT
FRONT
3
8
UNIT BACK

9 10
OPERATION (Refer to pp. 7 & 8 for Parts Identication) OPERATION (Refer to pp. 7 & 8 for Parts Identication)
7. Turn the Dial Switch to the lowest setting (see Figure D),
the humidier will begin to operate within a few seconds.
A blue LED light inside the unit will illuminate when the
unit is working.
8. UV LED will illuminate within a few seconds after the unit
is turned on (see Figure E). UV LED provides add on germicidal
protection.
9. When the dial switch is turned further to the right, the mist
output will be set to the maximum level. You may notice a ne
mist of water around the unit when dial is set to the maximum
level. To eliminate that, simply turn the dial to the left to set
to a lower level.
10. When the desired humidity level is reached (50%), the
dial switch can be set to a lower level by turning to the left.
11. When the water bottle is almost empty, it will slightly tip
to the side. This is normal. Just remove the empty water bottle.
Then unscrew the bottle adapter and ll up the bottle with
water (you may use tap water). Then place the adaptor back
on and place the bottle upside down. Turn the unit back on
to the desired level.
12. In case there is no water in the bottle, the humidier will
automatically shut o. Blue LED will remain illuminated when
there is no water in the bottle; it will be o when the unit is
turned o. Once the water is relled, the humidier will start
working again.
Figure D
Figure E
Germicidal
UV LED
OPERATION
NOTE: Before the humidier is used, check all accessories
are included:
• 120~240VAC Adaptor
• cleaning brush
•storage pouch.
1. Fold out the feet under humidier and make sure
feet are rmly opened and xed under the humidier
(see Figure A). The feet stabilize the humidier with a
bottle on the top.
2. Ensure the mist/nozzle outlet is in the open position,
otherwise humidier will not work.
4. 17oz / 0.5 liter water bottle is recommended.
You may also ll the empty water bottle with tap
water.
5. Insert water adaptor into the water bottle,
then quickly place the other side of water adaptor
into the humidier (see Figure B+C). DO NOT
over tighten the water adaptor. The water bottle
should not be squeezed since it will cause the
humidier to overow.
6. Plug AC adaptor directly into wall outlet.
Figure A
Figure B Figure C

11 12
CLEANING AND MAINTENANCE
1. Turn o the humidier and unplug the unit
from its electrical outlet before cleaning.
2. To prevent mold, bacteria, lm and scale from
forming, it is recommended the upper part, the
mist outlet/nozzle, water adaptor, the water bottle,
and ultrasonic nebulizer be cleaned once every
two weeks (see Figure E).
3. Clean the inner parts with a soft cloth. DO NOT
use any aggressive cleaning agent or detergent
to clean the humidier.
4. Only use the included brush to clean ultrasonic
nebulizer. This should be done once a week
(see Figure F).
5. Use water only to clean.
6. Do not immerse humidier in the water when
cleaning.
7. No water should come into the contact with
the air vents.
8. NONE of the parts are dishwasher safe –
so it cannot be cleaned in a dishwasher.
CLEANING AND MAINTENANCE SPECIFICATIONS
max.
Cleaning Brush
Ultrasonic Nebulizer
Figure F
Electrical Voltage
Power Consumption
Recommended Bottle Size
Dimensions (L x W x H)
Weight
Operation Noise Level
100~240 VAC 50-60Hz 0.5 A
DC 24V 0.65A 15.6W (Max)
17 oz / 0.5 liter
4.36” x 2.88” x 4.53”
0.8 lbs (including Adaptor)
< 30 dB
Figure E
Table of contents