Benewake TF03 User manual

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page1
TF03 LiDAR
4-20mA
User Manual

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page2
Product
Product Number:TF03 version 4-20mA
Product name:TF03 LiDAR
Manufacturer
Company: Benewake (Beijing) Co., Ltd.
Address:NO.28 Xinxi Road, Haidian District, Beijing, PRC
Copyright
The Copyright of this document is protected. All the rights involved herein belong to Benewake
(Beijing) Co., Ltd. Any copy activity of this document, no matter in whole or in part, should be in
conformity of the Copyright Law. The actives of modification, omission or translation of this
document are not allowed unless a written permission from Benewake (Beijing) Co., Ltd.
All rights reserved © Benewake (Beijing) Co., Ltd.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page3
Forward
Dear users:
Thanks for choosing Benewake products, and it is our pleasure to help you to solve any technical
question.
For offering a better operation experience to you, we hereby write this manual for an easier and
simpler operation of our product, hoping to solve the common problems in better way you may meet.
Please contact us if you have any questions. ([email protected])
This operation manual covers the product operation introduction and common problem solutions, but
it is hard to cover all the problems you maybe meet. So if you have any further questions or problems,
please feel free to consult our technical support service ([email protected]). We will do our best to
solve any problem related to the product. If you have any other good advice or suggestions, welcome to
visit our official website and offer us your feedback there (http://www.benewake.com/feedback.html), and
we are looking forwards to your participation.
We are Benewake who dedicated to making the best “Robotic Eyes” worldwide!

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page4
Table of Contents
1 ATTENTIONS ............................................................................................................................................ 5
1.1 A
BOUT THIS
D
OCUMENT
............................................................................................................................ 5
1.2 U
SAGE OF THE
P
RODUCT
............................................................................................................................ 5
1.3 C
ONDITIONS WITH
P
OTENTIAL
P
RODUCT
F
AILURE
............................................................................................ 5
2 PHYSICAL INTERFACE ............................................................................................................................... 6
2.1 D
ESCRIPTION ABOUT THE LINE SEQUENCE AND CONNECTION
.............................................................................. 6
2.2 E
LECTRICAL
C
HARACTERISTICS
...................................................................................................................... 7
3 INSTALLATION INSTRUCTIONS ................................................................................................................. 7
3.1 P
RODUCT
O
VERVIEW
................................................................................................................................. 7
3.2 P
RODUCTS
S
TRUCTURE
.............................................................................................................................. 7
3.3 D
ETECTION
A
NGLE
D
ESCRIPTIONS
................................................................................................................ 8
4 COMMUNICATION PROTOCOL AND DATA FORMAT ................................................................................. 9
4.1 C
OMMUNICATION
P
ROTOCOL
...................................................................................................................... 9
4.2 C
USTOM PARAMETER CONFIGURATION
........................................................................................................ 10
4.2.1 I
NSTRUCTION GENERAL FORMAT DESCRIPTION
.................................................................................................. 10
4.2.2 C
OMMANDS
............................................................................................................................................... 11
5 QUICK TEST PROCEDURES ...................................................................................................................... 12
5.1 T
EST EXAMPLE
........................................................................................................................................ 12
5.1.1 T
EST
R
ANGE WITH
D
IFFERENT
R
EFLECTIVITY
.................................................................................................... 12
5.1.2 T
ESTING
A
CCURACY OF
D
IFFERENT
M
ATERIALS
................................................................................................. 12
5.1.3 R
EFLECTIVITY OF
C
OMMON
M
ATERIALS
.......................................................................................................... 13
6 FREQUENTLY ASKED QUESTIONS ........................................................................................................... 14

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page5
1 Attentions
1.1 About this Document
This Manual provides information necessary for the use of this product.
Please read this Manual carefully before using this product and make sure that you have
fully understood its contents.
1.2 Usage of the Product
Qualified professionals can only maintain this product and only the original spare
parts can be used to ensure its performance and safety.
The product itself has no polarity and overvoltage protection. Please complete
wiring and supply power correctly according to the contents of the Manual.
The working temperature of the product is -25°C~60° C; please do not use it
beyond this temperature range, to avoid risks.
The storage temperature of the product is -40°C~85°C; please do not store it
beyond this temperature range, to avoid risks.
Do not open its enclosure for assembly or maintenance beyond this Manual;
otherwise, it will affect the product performance.
1.3 Conditions with Potential Product Failure
When the product transmitter and receiver lens is covered by dirt, there will be a risk of
failures. Please keep the lens clean.
The product will have a risk of failure when immersed completely in water. Do not use it
underwater.
When detecting objects with high reflectivity, such as mirrors and smooth tiles, the
product may have a high risk of failures.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page6
2 Physical Interface
2.1 Description about the line sequence and connection
Wiring terminal model: MH1.25-7P.
Figure 1:TF03 Line Sequence
Table 1 TF03 Pin functions and connection instructions
No Color Pin Function
1 Red VCC Voltage Input
2 White / /
3 Green / /
4 Blue I_out 4-20mA output
current
5 Brown TTL_RXD UART Receiver
6 Yellow TTL_TXD UART Transmitter
7 Black GND Ground

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page7
2.2 Electrical Characteristics
This product has no overvoltage or polarity protection. Please ensure that the wiring and
power supply are normal, and the supply voltage is allowed to fluctuate by ±0.5V.
Table 2 main electrical parameters
Parameter Typical Value
Power supply voltage 12-24V
Average
≤
140mA @ 12V
≤
80mA @ 24V
Peak current
≤
140mA @ 12V
≤
80mA @ 24V
Average power
≤
2W
3 Installation Instructions
3.1 Product Overview
Figure 2: Exterior of TF03
3.2 Products Structure
The LiDAR mounting holes are applicable to M3 screws. Note that the length of the screw
entering the enclosure shall be no more than 3.5mm.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page8
Figure 3: TF03 structure dimensions(Left 1:top view,Left 2:vertical view,Left 3:front view)
3.3 Detection Angle Descriptions
TF03 has a 0.5-degree detection angle and rectangular light spots; see Table 3 for
simulated,diagrams of the light spots. Therefore, at different distances, the spot size, namely
detecting range, is different as shown in Figure 4.
Note: The side length of common objects detected should be greater than that of the detection
range of TF03; when the side length of the detected object is less than that of the detection
range, the LiDAR effective range will be reduced
Figure 4: Detection angle schematic of TF03
Table 3: Spot simulated diagrams and sizes at different distances

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page9
Spot 20m away Size
:
20cm*6cm Spot 50m away Size
:
50cm*14cm
Spot 100m away Size
:
100cm*28cm Spot 150m away Size
:
150cm*42cm
Note:In the light intensity distribution of the spot, red is the strongest, green is weak, dark
blue is the background, and the spot size is the length and width of the green in the figure.
4 Communication protocol and Data format
TF03 4-20mA version supports current analog output, TTL serial port is used fir debugging
purpose.
4.1 Communication Protocol
TF03 outputs 4-20mA analog quantity, the current size represents the distance size, divided
into two modes, forward mode and reverse mode, the default is forward mode, see
Table 4 for details. The sampling resistance of the user is limited to less than 300 ohms. The
distance value represented by 20mA current can be modified by the command to configure the
over range value. For details, see 4.2.2.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page10
Table 4 1.1 4-20mA analog version data description
Mode Current Value Distance Value Description
Forward mode
4mA 0m
Default
20mA 180m
Reverse mode
4mA 180m Can be modified by
serial commands
20mA 0m
4.2 Custom parameter configuration
4.2.1 Instruction general format description
Custom parameters configurations are open in order that problems could be solved
conveniently. Parameters, such as output data format, output frame rate could be changed by
sending command. Parameter will be stored in flash and need not to be configured again if
restart after configured successfully.
Please change the configuration according to the real demands and never try uncorrelated
command frequently thus unnecessary loss from wrong command; please configure the product
according to the demands of the manual and never send unstated command.
The Format of Command is:
Byte byte0
byte1
byte2
byte3~ byteN-2
byteN-1
Descriptions
Head
Len ID Payload Check sum
Head:fixed to 0x5A
Len:the length of the entire instruction frame (unit: Byte)
ID:identifies the function of each instruction
Payload:have different meanings and lengths in different ID instruction frames
Check sum:the lower 8 bits of the Len-1 byte data.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page11
4.2.2 Commands
Function Command Response Remark Default
Setting
Obtaining
version number 5A 04 01 5F 5A 07 01 V1 V2 V3 SU
Version number V3.V2.V1
SU is check sum,the same
below
/
System reset 5A 04 02 60
success
:
5A 05 02 00 61
Failed:there isn’t any
reaction over 1s
/ /
Frame rate 5A 06 03 LL HH SU
Success
:
same as
command
Failed:there isn’t any
reaction over 1s
/ 100fps
Reset to factory
settings 5A 04 10 6E Success
:
5A 05 10 00 6F
Failed
:
5A 05 10 ER SU Fail(when ER is not 0) /
Save settings 5A 04 11 6F Success
:
5A 05 11 00 70
Failed
:
5A 05 11 ER SU Same as above /
Configuring
over range
threshold value
5A 06 4F LL HH SU
Success
:
5A 05 4F 00
AE
Failed:there isn’t any
reaction over 1s
over range threshold value
=(HH << 8) + LL,unit cm 18000
Enabling
rain-fog
algorithm
Enable:5A 05 64 00 C3
Disable:5A 05 64 01 C4
Success
:
5A 05 64 00 C3
Failed:there isn’t any
reaction over 1s
/ Enable
Configuring
offset 5A 06 69 LL HH SU
Success
:
5A 05 69 00 C8
Failed:there isn’t any
reaction over 1s
Offset = (HH << 8) + LL,
unit cm 0
4-20mA version
configuration
forward and
reverse
Forward:5a 05 71 00 d0
Reverse:5a 05 71 01 d1
Success:5a 05 71 00 D0
Failed:there isn’t any
reaction over 1s
Forward
Interpretation:
1) The supported output frame rate is as follows:
1、2、…9、
10、20、…90、
100、200…900、
1000、2000…9000、10000;
2) When using the trigger mode, you need to disable data output, and then use the trigger
command;

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page12
3) The Pixhawk data format is output as “x.yz\r\n”. For example, if the measurement
distance is 1.21m, the string 1.21 will be output, followed by the escape character \r\n.
5 Quick Test Procedures
5.1 Test example
5.1.1 Test Range with Different Reflectivity
As shown in Figure 5, the 180m version of TF03, red and blue curves represent the
relationship between the reflectance and range of the target under different ambient light
intensities indoors and outdoors, respectively.
Figure 5 TF03 the relationship between TF03 range and reflectance (version 180m)
5.1.2 Testing Accuracy of Different Materials
The test accuracy of TF03 at different distances and reflectivity is shown in Figure 9. Two
typical background boards(blackboard and whiteboard), are selected. The reflectivity of
whiteboard is 90% and that of blackboard is 10%.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page13
Figure 6: TF03 Error curves of TF03 at different distances and reflectivity
5.1.3 Reflectivity of Common Materials
The reflectivity of common materials is listed below, ranging from low to high. According to
the test target and the corresponding reflectivity, we can measure whether the range of TF03 and
other parameters meet the requirements.
S. No.
Material Reflectivity
1 Black foam rubber 2.4%
2 Black cloth 3%
3 Black rubber 4%
4
Coal (varies from coal to coal)
4~8%
5 Black car paint 5%
6 Black paper 10%
7 opaque black plastic 14%

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page14
8 Clean rough board 20%
9 News papers 55%
10 translucent plastic bottles 62%
11 packing case cardboard 68%
12 Clean pine 70%
13 opaque white plastic 87%
14 white card 90%
15 Kodak standard whiteboard 100%
16 Unpolished white metal surface 130%
17 Shiny light metal surface 150%
18 stainless steel 200%
19
Reflective board, reflective
adhesive tape
>300%
6 Frequently asked questions
Q1:Can TF03 support other voltage input.
A1:At present, other voltage input are not supported. If you have other needs, you can
contact our sales staff for further inquiries about customization.
Q2:Can TF03 changes the data output frequency. Can the output be switched?
A2 :TF03 has currently opened custom parameter configuration and output mode
adjustment. The switch function needs to be customized according to the needs. You can consult
our sales or technical support for details.
Q3:: Can TF03 work normally in rain, snow and fog?
A3:TF03 has a firmware version of the algorithm that penetrates the rain and fog. Contact
the sales or technical support personnel for firmware upgrade. The algorithm is turned on by
default in V1.11.15.

TF03 4-20mA User Manual V1.1
Benewake(Beijing)Co., Ltd.
Page15
C o n t a c t d e t a i ls
Headquarters:
010-57456983
bw@benewake.com
suppor[email protected]
Technical Support:
Other manuals for TF03
6