KEEP
THIS
MANUAL
FOR
FUTURE
REFERENCE.
Follow
all
instructions
carefully
for
installation,
maintenance
&
operation
of
the
DO
110
&
DO
180
boilers.
«•
CAUTION
•»
DO
NOT
TAMPERWITH
THE
UNIT
OR
CONTROLS
-
CALL
A
QUALIFIEDSERVICE
TECHNICIAN.
DO
NOT
LEAVECOMBUSTIBLEMATERIALAROUND
THE
UNIT.
DO
NOT
stackitems
onor
around
the
unit
-
checkrequiredclearances
on
page
2.
DONOT
start
a fireinthe
boileruntil
all
installationrequirements
are
complete
andthe
operating
instructions
are
understood.
DO NOT use
automaticstoking
or
sawdust
fueling
withthisunit.
DO
NOT
BURNGARBAGE,PAPER(except
to
start
fire),
FLAMMABLELIQUIDS,DRIFTWOOD,
TREATEDWOOD(CREOSOTE,PRESERVATIVES,PAINT,STAIN,ETC.)
IN
YOURBOILER.DAMAGE
WILL
RESULT
AND
VOIDYOURWARRANTY.
DO
NOT
allow
anyonethat
is
unfamiliarwith
the
boiler,
to
attend
it.
DONOT
loadwoodabove
the
smoke
flap
inside
the
door,over-firing
may
result.
DO
NOT
adjust
the
draft
regulatorabove
- .05
"
W.C.,
if
thissetting
is
exceeded
it
couldcause
thefireto
burn
out
of
control.
DO
know
the
location
ofthe
emergencydisconnectswitch
forthe
unit.
DO
contact
a
qualified
service
technician
before
remodeling,
for
annual
service/maintenance,
before
extendedperiods
of
shutdown
and
beforestart-up.
-PRE
INSTALLATION
CONSIDERATIONS-
FUEL
Burn
onlyclean, untreatedhardwood,
and
softwood.
Forthe
bestperformance,
we
recommendusingseasoned(below
25%
moisture)hardwood.Store
the
wood
in
neat,
wellsupportedpiles,
at
least
4'
from
the
boilerloadingdoor.
BOILER
In
thefirebox
install
ashor
sand
to
within
1
1A"
ofthe
bottom
door
frame
or
burnsoftwood
atfirst,
which
creates
ash
quickly.Thiswillimprove
theairflow
through
the
wood.
The
boilermust
be
installed
bya
qualified
technician
currentlyactive
inthe
heatingtrade.
The
installationshouldmeet
or
exceed
all
local
and
national
codes
having
jurisdiction,including
C.S.A.
B365,
the
InstallationCode
for
SolidFuelBurningAppliances
&
Equipment.
The
boiler
has
beenthoroughlytestedwithmodernbaseboardradiation.
UNDERFLOOR
&
CAST
IRON
RADIATORS
Specialconsiderationmust
be
taken whenconnecting
the
boiler
to
underfloor
systemswithoutoxygenbarrier
pipe
or
whenhooked
to
castironradiators,
to
preventthermalshock
or
excesstemperaturewater
from
entering
underfloor
heatingloops.Pleaseconsultwithyoursystemdesigner.
CHIMNEYSYSTEM
The
specification
ofthe
chimney
tobe
usedcomplieswith
the
requirementthat,otherthan
solid-fuel/oil
combinations
and
add-ons,woodburningappliancesshall
notbe
connected
toa
venting
system
serving
an
appliancevented
by
anothertype
of
fuel.
Connect
the
furnace
toan
approvedsolid
fuel
factory-built
chimney
(CANADA-CAN/ULC
S629standard
for
650°chimney,UNITED
STATES-UL103
'
Chimneys
for
ResidentialType
and
BuildingHeatingAppliances,Factory
Built)
ora
safe,
clean,
sound
condition,
masonrychimneyequipped
with
an
approved
liner
(CANADA-CAN/ULC-S635-M90
Standard
for
LiningSystems
for
existingmasonry
or
Factory
Built
Chimneys
and
Vents,
UNITED
STATES-UL1777
Chimney
Liners)(e.g.,
stainlesssteel,clay,etc.)
The
chimneymust
be
capable
of
maintaining
a
negative
updraft
atall
times
andinall
conditions.
Carefully
inspect
the
chimney
for
safety
before
making
a
connection.Locate
the
boiler
as
close
tothe
chimney
as
possible.
DONOT
pass
the
smoke
pipethrough
the
ceiling,wall
or
floor
to
reach
the
chimney.
Installation
of
this
equipment
shall
be
in
accordancewithregulations
of
authorities
having
jurisdiction
and(in
Canada)
CSA
Standard
B139
"Installation
Code
forOil
BurningEquipment"
andCSA
B365
Installation
Code
for
Solid
Fuel
Burning
Appliances
and
Equipment,(in
UnitedStates)
UL
391
SolidFuel
and
Combination
Fuel
Central
and
Supplementary
Furnaces.
-1-