1/19
Dear Bioland Blood Glucose Monitoring System Owner:
Thankyouforchoosingthis
system!
Thismanualcontainsimportantinformationyou
must
knowaboutthe
system.
Pleasereaditthoroughlyand
carefully.
Th
e
syste
m
provides
No
Code
functio
n
which
means
that
youdon'tneed
to
calibrateyour
metermaking
it
easier
fortheuser
to
monitorbloodglucoseat
home.
IMPORTANT SAFETY
INSTRUCTIONS
Themeterandlancingdeviceareforsinglepatientuse.Donotsharethemwithanyone
includingotherfamilymember!Donotuseonmultiplepatients!
AlIpartsofthekitareconsideredbiohazardousandcanpotentiallytransmitinfectious
diseasesevenafteryouhaveperformedcleaninganddisinfection.
Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliance
couldvoidtheuser’sauthoritytooperatetheequipment.
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo
conditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust
acceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital
device,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,
usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions,maycauseharmfulinterferencetoradiocommunications.However,
thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.
ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolled
environment.EndusermustfollowthespecificoperatinginstructionsforsatisfyingRF
exposurecompliance.Thistransmittermustnotbeco‐locatedoroperatinginconjunction
withanyotherantennaortransmitter.
Theportabledeviceisdesignedtomeettherequirementsforexposuretoradiowaves
establishedbytheFederalCommunicationsCommission(USA).TheserequirementssetaSAR
limitof1.6W/kgaveragedoveronegramoftissue.ThehighestSARvaluereportedunderthis
standardduringproductcertificationforusewhenproperlywornonthebody
Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcan
bedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrect
theinterferencebyoneormoreofthefollowingmeasures:
‐‐Reorientorrelocatethereceivingantenna.
‐‐Increasetheseparationbetweentheequipmentandreceiver.
‐‐Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver

2/19
isconnected.
‐‐Consultthedealeroranexperiencedradio/TVtechnicianforhelp.
READ THIS BEFORE USING
DANGER‐Misuseofthiselectricaldevicecancauseelectrocution,burns,fireandother
HAZARDS.
Basicsafetyprecautionsshouldalwaysbetaken,includingallthoselistedbelow.
Closesupervisionisnecessarywhenequipmentisusedby,on,ornearchildren,
handicappedpersonsorinvalids.
Thefollowingbasicsafetynoticeshouldalwaysbetaken:
1.Donotplacethedeviceinliquid,norputitwhereitcouldfallintoliquid.
2.Thefollowingbasicsafetynoticeshouldalwaysbetaken.
3.Usethedeviceonlyfortheintendedusedescribedinthismanual.
4.Donotuseadjunctwhicharenotsuppliedbytheproducer.
5.Donotmakethedevicecomeintocontactwithsurfaceswhicharetoohottotouch.
6.Donotusethedevicewhereaerosolspraysarebeingused.
7.Donotusethedeviceifitisnotworkingproperly,orifithasbeendamaged.
8.Readallthemanual,andpracticethetest,andthenusetheproducttotestyourblood
glucose.Doallqualitycontrolchecksasdirectedandconsultwithadiabetesexpert.
KEEPTHESEINSTRUCTIONINASAFEPLACE

3/19
Table of Contents
BEFOREYOURBEGIN.........................................................................................................................4
INTRODUCTIONTOTHESYSTEM.......................................................................................................4
IndicationsforUse....................................................................................................................4
Caution......................................................................................................................................5
Testprinciple.............................................................................................................................5
ABOUTALTERNATIVESITETESTING(AST).........................................................................................5
CONTENTSOFTHEKITS.....................................................................................................................6
BloodGlucoseMeter.................................................................................................................7
MeterScreenDisplayMessage.................................................................................................7
TestStrip....................................................................................................................................8
SETTINGTHEMETERANDDELETINGTHEMEMORY........................................................................8
THETWOMEASURINGMODES.......................................................................................................10
TESTINGWITHBLOODSAMPLE......................................................................................................10
OverviewoftheLancingDevice..............................................................................................10
SettingUptheLancingDevice.................................................................................................11
Preparingthepuncturesite....................................................................................................12
PerformingaBloodGlucoseTest ............................................................................................12
ComparingMeterandLaboratoryResults..............................................................................14
CONTROLSOLUTIONTEST...............................................................................................................14
VIEWINGRESULTSONTHEMETER.................................................................................................15
CAREANDSTORAGEFORYOURSYSTEM........................................................................................16
CleaningandDisinfection........................................................................................................16
METERSPECIFICATION....................................................................................................................17
Limitationsofuse:...................................................................................................................17
DISPLAYMESSAGE...........................................................................................................................18
Problems.................................................................................................................................19

4/19
BEFOREYOURBEGIN
Installingthebattery
1.Openthebatterycoveronthebackofmeter.
2.Ifreplacingthebatteries,pleaseremovetheused
batteries.
3.Insert2new(AAA)batterieswithcorrect+/‐direction.
4.Closethebatterycover.
EnvironmentProtection–Wasteelectricalproductsshouldnotbedisposedofwith
householdwaste.Pleaserecyclewherefacilitiesexist.CheckwithyourlocalAuthorityor
retailerforrecyclingadvice.
INTRODUCTIONTOTHESYSTEM
IndicationsforUse
TheBloodGlucoseMonitoringSystemisintendedtobeusedforthequantitative
measurementofglucose(sugar)infreshcapillarywholebloodsamplesdrawnfromthe
fingertip.TheBloodGlucoseMonitoringSystemisintendedtobeusedbyasinglepatientand
shouldnotbeshared.
TheBloodGlucoseMonitoringSystemisintendedforself‐testingoutsidethebody(invitro
diagnosticuse)bypeoplewithdiabetesathomeasanaidtomonitortheeffectivenessof
diabetescontrol.TheBloodGlucoseMonitoringSystemisnottobeusedforthediagnosisof
orscreeningofdiabetes,orforneonataluse.
TheTestStripsareforusewiththeBloodGlucoseMetertoquantitativelymeasureglucose
drawnfromthefingertips.
Table of contents