Biontech BTM-505N User manual

WATER IONIZER
Read this manual carefully for proper use of the product. Keep the manual in a safe place and refer
to the manual whenever necessary.
Our company will not be held responsible for any malfunction or accident resulting from incorrect installation or
improper handling.
Note : There is a protection film on the operation panel of this product.
Bion-tech
OPERATION MANUAL
Model : BTM-505N
Dedicated to runing water lines

Table of contents
Use this manual to install the product correctly.
Make sure that all plumbing and electric work comply with the regulations of your residence.
Discontinue and seek for professional help if you inspect a water leakage.
The performance of the unit will depend on the quality of water source.
Please check water condition before the installation of this product.
Biontech Co., Ltd. will not be held resposible.
Please keep this manual and other documents for future reference.
2
Table of contents
1. Name and description of each part of the product 4
2. Safety preparations 6
3. How to install 8
Installation precautions 8
How to install 9
4. Before using the product 13
Precautions for using the product 13
Using the product appropriately for each purpose 14
How to store and manage the product after it is used. Precautions for using it
16
5. How to generate ionized water 17
Selecting the alkaline ionized water 17
Selecting the acidic ionized water 17
Selecting the purified water 18
How to measure the pH value 19
6. When and How to replace the filter 19
When to replace the filter 18
How to replace the filter 20
Cleaning Filter 21
How to use cleaning filter 22
7. How to use ionized water 23
8. Before you think the system is malfunctioning 25
Questions and Answers (Q&A) 25
About after service (A/S) 27
9. Product Specifications 31

Components
The following components need to be checked before installation.
The illustration shows basic components, their shapes may appear different
from the actual components.
If malfunctioning is generated because genuine components designated by the
company are not used, the warranty service will not be provided.
3
Components
Wall-hanging Nails and Fuse
Hose
pH Comparison Sheet
Flexible Alkaline Faucet
Hose Band
pH Test Solution
7x9 PVC hoses: 70cm
1/4" standard hose: 2m (PE reinforced hose)
1 Fuse
2 Nails
2 Screws
2 Anchor Bolts
For Water Outlet
Installation Drawing
Safety Pins
For Mounted Wall
x1
x2
x1
x1
x1
For
Water
Outlet
(Optional)
x1
Valve Cover
Adaptor(Optional)
x1
x1
Water Supply Control Valve Set
x1 x1 x2 x1
Water outlet
x1
x1

4
Front Side
Source water inlet
Source water outlet
Number Name Function
1 Front Plate Where the circuit systems and devices are fixed
2 Operating Panel Operation and display of functions
3 Flexible Alkaline Faucet Outlet pipe from which the alkaline ionized water flows out
(Acidic ionized water flows out when the acidity is chosen)
4 Back Plate Protective cover for the internal circuits and components
5 Filter Cover Protective cover for the filter
6 Bottom Plate Where the transformer, electrical cords and devices are fixed
7 Acidic Water Outlet Outlet pipe from which the acidic ion0ized water flows out
(Alkaline ionized water flows out when the acidity is chosen)
8 Inlet Supplys the source water to the product
9 Wall-hanging Hole Hangs the product on the wall using nails
10 Fuse Holder Safety system (Rated fuse : According to the area’s electric power condition)
11 Speaker For voice guidance and buzzer sounds
12 Volume Adjustment Adjusts the volume of the voice guidance
13 Water Supply Adjustment Valve Controls the operation of the product and the volume of water
14
Water Supply Control Valve
Ionizer operation and water flow adjustment (on/off)
15 Fliter cover locking device Place where the fiter cover is safely locked
Rear Side
Bottom Side
Safety pin
Water supply valve one-touch fitting
Water supply valve
(One-touch)
[Inlet detailed picture]

5
Indication light for
purified water
To be turned on when purified
water is chosen
Operating Panel
Indication light for
alkaline ionized water.
To be turned on when alkaline
water is chosen
Indication light for
acidic ionized water.
To be turned on when the acidic
water is chosen
[Acidic ionized water]
selection button.
Button for selecting
the acidic ionized
water
[Purified water]
selection button.
Button for selecting the
water purification function
only
[Alkaline ionized water]
selection button.
Button for selecting the
alkaline ionized water
Indicating the errors for
- Overheated
electrolytic bath
- Failed self-cleaning
- Excessive water
cleaning flow
Colume
- Not approved
filter
Indicating the filter
usage status.
The usage status of the
filter
Indication light for
flow volume.
High indication light.
Indicating when the flow
volume is higher than the
appropriate level
Standard indication
light
Indicating when the flow
volume is normal, and the
indication level is varies
depending on the flow
volume
Low indication light.
Indicating when the flow
volume is lower than the
appropriate level

6
- Caution - You should read the documents marked with the following symbols.
- Instruction
- Prohibition
Indicates the possibility of the product causing electric shocks if it is disassembled.
Indicates that deadly effect can be caused to the body if you use the product wrongly because of
your disregard for the items.
The following describes the precautionary items that can prevent the potential damage to
the body or the property. The cases of misapplication and resultant risks are divided into
Warning and Caution items. You are required to read thoroughly and comply with the
descriptions considering they are related to your safety.
Description of the symbol marks
Warning
Indicates that injury to the body or damage to the property can be caused. if you use the product
wrongly because of your disregard for the items.
Caution
Disassembly to
be prohibited
Indicates the possibility of the product causing electric shocks due to electric
leakage if it is submerged.
Showering to be
prohibited
Indicates the possibility of the product or components catching fires due to external
sources of fire.
Fire sources to
be prohibited
Indicates the general items to be prohibited.
General items to
be prohibited
Marks
Classification
Description
The plug needs to be disconnected from the wall socket if there is a
possibility of malfunctioning or lightening.
Disconnecting the plug from the
wall socket.
Items related to the general behaviors of users.General
Marks Classification Description

This application can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
7
- Warning - Should be followed for your safety.
Do not apply any different power voltage other than the indicated power voltage.
If not followed, fires or electric shocks can be caused.
The fuse capacity of the product is 3A. Do not use any other fuse with different capacity.
Stop using the product immediately when any malfunctioning is found.
Do not handle the electric plug or operate the power button with wet hands.
If not followed, electrical shocks can be caused.
Should hold the electric plug when inserting it into the wall socket or removing it from the socket.
Damage to the electric cord, fires or electrical shocks can be caused when if the cord is pulled.
Clean the wall socket after removing the electric plug.
- When there are lots of dusts settled on it, fire can be caused.
Do not connect multiple cords to one single wall socket.
When a wall socket is shared, abnormal heat can be generated, possibly causing a fire.
Electrical shocks, short-circuiting, ignition of fires can be caused if a damaged electric cord or plug is used
Do not damage, process or forcibly wind or pull the electric cord.
- The cord can be damaged, possible leading to fires or electric shocks.
Do not fix the electric cord by using a stapler.
- The cord can be damaged, possible leading to fires or electric shocks.
Should not arbitrarily modify, disassemble or repair the product.
If not followed, fires and electric shocks can be caused.
The company will not be held responsible for any accidents generated from such activities.
Electric shocks can be caused if the product is dropped into water by mistake.
The following measures need to be taken.
Remove the electric plug from the wall socket.
Recover the product from the water.
Contact the sales shop or the main office for advice.
WEEE Directive

8
Installation Precautions
Do not install the product in a place where the
sunlight comes in directly or the temperature
goes below zero.
If not followed, the case can be
transformed or broken due to freezing.
Precautions for connecting the acidic water
hose.
Install the acidic water hose lower than the main case.
If the hose is longer than necessary or higher
than the main case, the ion generation can
be affected, possibly leading to a change in
the taste of water.
Should connect the product to the cool water
pipe (If connected to the warm water pipe,
the purification filter and the electrolytic bath
can be damaged)
If not followed, the life span of the filter will
be shortened.
Avoid any place where heat of fire can be directly
contacted
If not followed, the case can be transformed,
possibly leading to water leakage
Do not modify the product arbitrarily.
Do not use the product in a place full of moisture
or dusts
If not followed, damage to the product or risk to
your safety can be caused.
If not followed, damage to the product or risk to
your safety can be caused.
Should hold the bottom plate of the main case.
It will be safe to move the product by holding the
product at the bottom plate.
Do not place any other objects on the product.
Do not install the product in the areas described as the following.
Caution
If the product is dropped, electric shocks can be caused due to the internal malfunction following the
impact from the dropping. The product needs to be taken to the sales shop or the main office in
order for you to request an inspection.
The purification filter can be broken due to freezing if the product is used in a place where it is
freezing cold, requiring the product, if not used, to be stored in a place where the breaking due to
freezing can be prevented, but after the purification filter is removed first.
Caution - Malfunction or accidents can be occured.
No warm water
Requiring you to check the rated voltage before
connecting the electric cord.

9
How to install
1. Wall mounted water tap
Caution
Check whether the components to be installed at the water tap are appropriate.
Should use the standard hose (1/4"), supplied by the company for the connection.
Use the one- touch adapter to fasten the hose before fixing the safety pin as illustrated in Page 3.
- If the standard hose is not used, damage due to water pressure can be caused, possibly leading
to water leakage
Do not connect the product to a warm water pipe.
- Degradation of purification capacity and malfunctioning can be caused.
1. Disconnect the water tap from the water pipe.
2. Rotating the adapter into the water pipe. (Single-water tap)
3. Assemble the water tap back into the adapter. (Single-water tap)
4. Install the standard compliant adapter Included (Select between large and medium, small, 3/8” )
between the water pipe and the water branch pipe. Then install the adapter which needs to be
connected to the water ionizer to the cold water pipe, while connecting the balancing adapter to the
warm water pipe. (Water taps for cold and warm water)
5. Place the rubber gaskets between the water pipes, water tap, and adapter, and should apply the
Teflon tape to the connection parts to assemble them.
6. Insert the inlet hose into the one-touch fitting installed to the adapter and then fasten the safety pin.
7. Adjust the water pressure control screw to a appropriate level.
(Alkaline water flow standard: 1.5 0.5 /min)
Should use the standard inlet hose (1/4") and fix the valve cover in the direction of the hose to prevent
the hose from being bent or the fastening nut from being loosened.

10
2. Deck type sink mounted water tap
The following fools ate necessary for installation work
[Drawing 1]
Electric drill Hole cutter
Size:
Diameter1/4”
Pipe wrench
or spanner
General
screwdriver
1. Prepare the tools for installation as drawing : Electric drill,
Hole cutter, Pipe wrench or spanner, General screwdriver,
Teflon tape 1pc (Drawing 1.)
2. Turn off the water valves before installation under the
sinkdeck.
3. Disconnet the water tap from the cold water pipe.
4. Drill a hole for the 1/4" hose appropriate place
somewhere in sinkdeck and make the connection to the inlet
of the product
5. Find the cold water pipe inside the sink deck and connect
the adapter to the cold water pipe (Drawing 2.)
[Drawing 2]
[Drawing 3]
[Drawing 4]
6. Connect the standard connection hose (1/4") to the adapter
installed with one touch fitting of union. (Drawing 3~4)
Insert the inlet hose deepest into the one touch fitting and insert
the safety pin as in drawing.
( Pls check if the hose has been securely fitted to the end of one
thouch fitting. if not, it causes water leakage for water pressure )
7. After the connection, adjust the water pressure control screw
to an appropriate level
(Alkaline water flow standard 1.5 0.5 /min )
8. Check any possible water leakage at the connection parts
after the installation
Should use the standard inlet hose (1/4") and fix
the valve cover in the direction of the hose to
prevent the hose from being bent or fastening
nut from being loosened.
Water valve of Cold water
Water pipe
Steel Hose
Ring nut Groove
Cold water side Hot water side
Water pressure
adjustment screw (Spindle)
Running water line
connection
Adaptor(small)
Place of hole drilled
Teflon tape
Acidic Water Outlet

11
4.
Hose Connected Method
After finishing of connection, assemble the valve cover with screws completely
Nut
Tap water
Hose Safety pin
valve cover
Hose
Acidic Water Outlet
3. Water Supply Control Valve
How to assemble the valve to the faucet
Assembly method of valve for
Deck-sink water tap
Take the little screen out
Cold water inlet Nut
Cold water inlet Nut Cold water inlet Nut
Tighten the screws with screw
driver, after inserting the rubber seal
Water flows into ionizer when the lever is turned to side
Water flows down ward when the lever is turned to down
Screw
The Adapter
Screw
The Adapter
Tighten the screws with screw
driver, after inserting the rubber seal
Tighten the screws with screw
driver, after inserting the rubber seal
Water Supply
Control Valve

12
6. How to install in different places
In case of power failures.
Turn off the water branch pipe in case of power failures.
(When letting water flow through, purified water will come out)
Use the product normally when the power is recovered.
In case of suspension of water supply.
Do not use the product.
Stop the water from flowing through when the water supply is suspended in the middle of using the product.
7. In case of power failures or suspension of water supply
When the water supplied is resumed, let the water flow sufficiently for direct water supply or showering in order to
help the inside air and other materials come out. Without going through such steps, the water still can be used
normally, but with the risk of drastic decrease of the life span of the filter when allowing air or other materials flow
through the main body.
A) When installing the product onto the wall
Apply water to the installation drawing and place it onto the wall while
keeping the horizontality
Of those nailing positions at the width (1~3) or the height
(2 ~4), choose the convenient ones for driving 2 nails
Place the hanging holes of the product onto the nails
: Positions of nails
B) When placing the product on the sink deck and its supports.
- Place the main case of the product on an appropriate position.
When the above steps are finished, use the hose to connect the valve cock
of the adapter to the inlet pipe at the bottom of the main case of the water
ionizer.
First of all, assembling the flexible pipe to the half-moon shaped alkaline water outlet at the
upper part by turning it clockwise.
1. Measure the distance between the place for installation and the adapter installed to the water tap and then
cut the hose with an extra length.
2. Cut the PVC hose for the acidic water into the length of 50~70cm and place it lower than the product.
The product can be used conveniently by placing it on any place by applying the wall mounting or stand type
(Turn table) depending on the place of installation.
After installation, connect the product to the AC120V power line.
When the water flows through the product, the power will be turned on automatically. Then, select Purified
Water menu to enable the water branch pipe to open and close repeatedly to allow the water to flow for 2~3
minutes freely. Then push the pH button to set the desired concentration and compare it with pH comparison
sheet. The black water that will come out is the filter dusts flowing with water, not dangerous to the body.
(Refer to How to measure the pH value in Page 18)
5. Steps for assembling the component before installing them
Should use the standard inlet hose (1/4") and fix the valve cover in the direction of the hose to prevent the
hose from being bent or the fastening nut from being loosened. The safety pin needs to be inserted before
using the water.
Caution
Do not install the product in the following areas:
- If not followed, malfunctioning can be caused.
You are required to contact the sales shop or the specialized installer for queries when you attach
the product to the wall.
Improper mounting may result in the product falling of, accident or mal-function.
If vibration and impact can be felt
If direct sunlight comes in
If there are lots of moisture or dusts
lf heat of fire can be felt
If horizontality can not be acquired
If bathroom is installed or winds and rains can affect
If there is a risk of breaking due to freezing
lf damage can be caused to the product

13
Danger - To reduce the risk of electrocutions.
Precautions for use
Warning - To reduce the risk of burns, electrocution, fire, or injury to persons.
Important safeguards

Precautions for using the product
Do not hold up the main case while holding the outlet flexible pipe. (Cause for breakage)
Do not operate the strong alkaline ionized water (Stage 5) continuously for a long period of time. If you use the
product in such manner, the system protective circuit (Temperature sensor) may be started, depending on the quality
of water, and the electrolysis can be suspended.
When using the product in a place where the water hardness is high.
Before using the water initially daily, push the acidic water button to allow the acidic water to flow
through for about 1 minute.
In case of tap water, in places where the water is used a lot. You need to push the acidic water button one time
daily to allow the water to flow through for the manual rinsing. (By selecting the acidic water button).
In places where the water hardness is high or compounds of calcium are abundant, there can be white
sedimentation inside the case, requiring additional purifying system to be used depending the level of the
sedimentation.
Use tap water only.
- This machine is manufactured for drinking water based on standard tap water.
Do not use the following water, as problems may arise:
Turbid and contaminated water Water with high hardness
Very salty water Water with high concentration of red rust
Caution
Caution
Do not fill the calcium container with no other substances than the designated.
- Glycerin acid calcium (Electrolysis facilitating calcium) or calcium sulfite (Removal of chloride).
Should turn off the water pipe when filling the calcium.
- If not followed, water leakage can be caused.
Check where the calcium container cap is surely fastened.
- If not fastened surely, water leakage can be caused when the water flows through.
14

High
Alkaline
Low
Low
Acidity
High
15
Use the product appropriately for each purpose
The pH value instructed is acquired by taking into consideration the source water based or Seoul, Korea
concentration of pH 7.0 0.5 based on the Alkaline water flow standard of 1.5 /m ( 0.5 ).
The pH values of the alkaline and acidic ionized water may not fall into the range of the pH value instructed of the
table above depending on the water quality and water flow volume.
Caution - Usage of the product
Do not use flammable materials like benzene or sprays for the product.
- Malfunctioning can be caused.
Sufficient attention needs to be paid when a child of young age uses the product.
Use the water initially daily after letting the water flow through for 10 ~ 15 seconds by opening the
water tap completely.
Use the water after letting the water flow through for more than 30 seconds when using the product
after not using it for a few days.
Contact the sales shop or the main office for advice when the generated water smells.
Do not drop the product or apply strong impact to it.
- Dropping or impact can cause malfunctioning.
Do not block the water outlet. If blocked, water leakage or malfunctioning can be caused.
Should place the outlet hose (Acidic water outlet) below the main case.
Do not use the water which is above 30 C If not followed, malfunctioning can be caused.
pH level selection
pH value instructed
Indicated
10.5 0.5
9.5 1.0
9.0 1.0
9.5 1.0
7.5 1.0
5.5 1.0
3.5 1.0
When infusing vegetables to remove their bitter taste
When washing soak vegetables
to eliminating Agricultral chemical.
Use it for drinking after consulting the doctor
Recommended for skin care an astringent
For washing dishes
Strong acidic sanitary or rinsing water can come
out when the water volume is adjusted
Rising with Acid water to elimininating Viruses Bacilli and
wash with Alkali water.
Recommendable for medical and culinary usage
Recommendable for drinking and cooking
Recommendable for daily drinking
Recommendable for initial drinking or dissolving
powdered milk
Purify

16
How to store and manage the product after it is used.
Precautions for using it
1. How to store and manage the product after using it.
Turn off the power before moving the product
Do not let water come inside the main body.
Do not block the outlet nozzle or the drainage hose arbitrarily. Do not bend or twist the hose arbitrarily.
Turn off the source water supply valve when the system will not be used for a long period of time.
Disconnect the electric cord from the wall socket when the system will not be used for a long period of time.
Clean the surface of the main body with soft cloth soaked with soap water.
2. Precautions for using it.
(1) Precautions to be taken when using the Alkal Life.
Pay attention to the following items when drinking the alkaline ionized water generated through the electrolysis.
Consult a doctor before drinking the strong alkaline water of stage 5.
Those people with achlorhydria need to take the advice from a doctor for drinking the treated water
Do not use any type of water that can not meet the water quality requirements for the drinking water
The product is designed exclusively for the water of normal temperature, so warm water should not be used.
Do not drink the alkaline ionized water together with medicine.
Those people who just started using the water need to begin with small amount of nearly pH neutral water.
They need to consult a doctor for drinking the strong alkaline water.
Stop drinking the water and consult a doctor if you feel abnormality after drinking the water, or if there is no alleviation
of symptoms felt in the stomach even after continuously drinking the water.
Those people who currently go through medical treatment by a doctor, especially because of problems with the kidney
or the body, need to consult a doctor before drinking the water.
Those people with problems with the kidney, such as renal failure, calcium excretion failure, should not drink the water.
Those people who drink the alkaline ionized water need to check, once a month since after the initial drinking, whether
the pH value is still within the range for drinking, through utilizing a glass electrode type pH device or colorimetry
before they continue to drink the water.
Drink after let the initial alkaline water flow through.
Avoid any metal container if possible and drink the water within a day while keeping it cold.
(2) Pay attention to the following items regarding the use environment and conditions.
Should keep the water flow volume at an appropriate level in order to prevent the alkaline ionized water from being
generated with difference in the pH value compared with the set pH value due to the difference in the water flow volume.
Do not use the product in a place, like a bathroom, where temperature or moisture is high.
Use the product in a place where there is no slope.
Cap
Non-woven fabric
UF Membrane Filter
General activated carbon
Calcium sulfite
Water Outlet
Non-woven fabric
General activated carbon
Special Fiber Pad
Non-woven fabric
Calcium Container(Optional)
General activated carbon
Water Outlet
Non-woven fabric
Sediment
Calcium Container cap

17
Selecting alkaline ionized water
Selecting acidic ionized water
1. Open the water supply control valve to let the water
flow in.
2. Use the pH button to select a stage.
- The value of selected pH stage is indicated.
- In case of “Alkaline”, any value between stage 1~5
will be indicated.
- When normally started, the system provides the
alkaline ionized water with previously set alkaline
value.
3. The product is ready to be used.
Voice guidance: “Alkaline Ionized Water on process.”
When the water supply control valve is turned off after
selecting and using “Strong” “alkaline”, the setting
will be restored back to the previously set value of
“Alkaline”.
Do not use the product in the “Strong alkaline” state
for a long period of time.
The power can be turned off due to the operation of
the system protective circuit depending on the
quality of water.
Indication light for water inflow.
When the tap water flows in, the water inflow indication light indicates Low when the
water pressure is low and High when it is high.
You are required to adjust and keep the water pressure to make the indication light stay
on at the center of the standard level.
When the indication light stays on at the standard level, about 1.5 0.5 /Min.
of water will flow through.
Operation indication panel Alkaline pH
indication button
When the acidity pH selection button for the operation is pushed, the acidic
ionized water will flow through the alkaline ionized water outlet.
1. Open the water supply control valve to let the water flow in.
2. Use the acidity pH selection button for selecting.
(Melody comes out while the product is being used)
Voice guidance: Acidic Ionized Water on process.
3. Push the pH selection button to select the 1st stage or 2nd stage to obtain
the water. When the water supply control valve is turned off in the middle of
the water being used, the setting will be restored back to the previously set
value of Alkaline . In order to stop the operation in the middle of the use,
other selection buttons need to be pushed to select other functions.
Indication light for water inflow.
Refer to the Selecting the alkaline ionized water.
Acidity pH indication
button
Indication of operation
in progress
Indication of operation
in progress

18
Selecting purified water -
Only processed through purification treatment, the water will go through the electrolysis process.
Indication of operation
in progress
Purified water indicating button
1. Open the water supply control valve to let the water flow in to generate the alkaline ionized
water of the set value.
2. Push the purified water indicating button.
- Indication light for purified water selection
Voice guidance: Crystal clear water on production.
3. Use the purified water.
4. When the water supply control valve is turned off in the middle of the water being used, the
selection of the purified water is called off and the setting will be restored back to the
previously set value of Alkaline . In order to stop the operation in the middle of the use,
other selection buttons need to be pushed to select other functions.
When the indication light for the purified water is turned off.
When there is a change in the water pressure leading to the lowering of the water level,
the indication light will be turned off and the setting will be restored back to the previously
set value of ‘Alkaline’. Use the product by setting the value again after adjusting the
water pressure.
Caution
Acidic ionized water is not for drinking, so do not drink it.
Use the water after letting the water flow through for about 5 seconds right after the generation is initiated.
Use the water initially daily after letting the water flow through for 10 ~ 15 seconds by opening the
water tap completely.
Use the water after letting the water flow through for more than 30 seconds when using the product
after not using it for a few days.
Should not remove the purification filter when letting the water flow through the main case.
Do not drink the drained water following the automatic Self-Cleaning, and the acidic water.

19
When to replace the filter
When the water tastes changes or the water flow volume decreases dramatically, you need to check whether the
life span is overdue.
When the filter usage status indicating number becomes 999 , it will blink.
It is recommended to replace the filter even before the end of life span is reached, if the water smells or the water
flow volume decreases, considering the life span can be different depending on the quality of water in individual areas
How to measure the pH value (Ion concentration)
Do not let the pH regent contact the eyes and do not drink it.
- In case of drinking it by mistake, you need to drink lots of water. In case of the test solution
contacting the eyes, you need to clean your eyes with sufficient water and then consult a doctor.
Do not place it near any heat of fire. If not followed, fire can be caused.
Do not store the regent in a place where it can be reached easily be children.
Avoid any place where the temperature or moisture level is high.
The pH test solution is an expendable item. It can be purchased at the sales shop or the main office.
Caution
The pH values (Ion concentration) of the generated alkaline or acidic ionized water can be measured.
Check the generated water after adjusting the water pressure to meet the standard water flow volume (1.5
0.5 /Min.) according to the ionized water generation method.
(The pH values can varies depending on the quality of water and the flow volume)
Materials to be prepared: The pH Regent - components
How to measure
1. Let the generated water (Alkaline or Acidic ionized water) flow through for about 10 seconds.
2. After filling a transparent glass water cup 1/3 with the water, drop 2~3 droppings of the pH Regent into the
water and shake it.
3. Compare it with the pH colorimetry.
Items that require your understanding
The color of the test solution will change as time goes by.
(Compare the color of the test solution with the pH colorimetry before too much time passes by after dropping the
test solution into the water)
When disposing of the undiluted test solution, you need mix it with water to make it light before letting it flow out.
When the pH concentration is measured, the color of the test solution can come out differently compared with the
pH colorimetry due to the effect of various substances dissolved in the water such as carbonic acid gas.
The pH color of the alkaline or acidic ionized varies depending on the pH level.
In the following cases, the replacement period can be shortened drastically:
When there is rusty water due to aged pipes
Lots of impurities in the water for a short period of time
If the product is used in a place where the water pressure is low.
Caution - Precautions for the pH test.

20
Do not disconnect the electric plug.
(When the plug is disconnected, the system can be restored when the reset button is pushed)
How to replace the filter
1.Open the cover and remove the filter. (Picutre1~3)
Be careful of the possible water coming out of the filter. (It is not leakage)
2.Replace with a new filter. (Picture 4)
Should remove the sealing sticker of the filter.
Check whether the O-ring is attached well at the bottom of the new filter first. Then, place the filter
into the hole securely and turn it clockwise to insert it into the connection part. If a unbranded filter
is installed, there will be a voice guidance saying Filter rejected, mount correct one. , and the
power will be turned off after 20 seconds.
3.Let the water flow through after selecting the purified water function.
Let the water flow through for about 2~3 minutes.
(Dusts of activated carbon which is the filtering medium may flow mixed together with water during
the initial flow after the filter is replaced.)
Check whether there is any water leakage at the installation section of the filter.
4. Push the reset button. (Picture 5)
Check whether the filter usage status indicating number becomes. [000]
5. Close the cover. (Picture 6)
Items that require your understanding
.
When you get the alkaline ionized water in a cup after the filter is replaced, there can be
white bubbles.. That is not abnormal.
The ion concentration (pH value) can become slightly higher after the filter is replaced (For
about 1 week). That is not abnormal.
Follow the steps mentioned above even when replacing the filter earlier than the time for
the replacement.
The filter without our company logo is not a genuine product. When a genuine filter is not used, the quality
cannot be guaranteed and the normal after sales service(A/S) will not be available.
(Picutre 1) (Picutre 2) (Picutre 3)
(Picutre 4) (Picutre 5) (Picutre 6)
Table of contents
Other Biontech Water System manuals
Popular Water System manuals by other brands

Culligan
Culligan Mark 100 owner's guide

ClayTech
ClayTech CMS B3A1 owner's manual

ProMinent
ProMinent ProMaqua Dulcodes A Assembly and operating instructions

Duda Solar
Duda Solar SC5815 Operation and maintenance manual

Everpure
Everpure Sediment Filter Wrap EV9799-04 Specification sheet

Daikin
Daikin Solaris EKSH26P quick start guide

Atlantic
Atlantic Oasis Filterfall instruction manual

US Water Systems
US Water Systems L1-200 manual

Johnson Controls
Johnson Controls YORK YLCA Series Quick installation guide

Zazen
Zazen Alkaline Water installation guide

Everpure
Everpure Kleensteam CT EV9617-11 Specification sheet

Everpure
Everpure Filter Cartridge i20002 Specification sheet