Bircher Reglomat RC Duo 2 User manual

RC Duo 2
Turning on the remote
Communication with the sensor
2
3
Bidirectional remote control
Once the remote has been powered on, Gwill illuminate in red and begin to blink. To establish a connection with a particular sensor, aim
at the sensor and press G. The sensor’s address (1 - 7) will illuminate on the keypad. The sensor’s LED will briefly illuminate to confirm
communication. The RC Duo 2 is now ready to program the sensor. For help in selecting a particular sensor out of several, see section 4.3,
sensor scan mode.
The connection between the RC Duo 2 remote control and the sensor can only be established while the sensor is in confi uration mode.
Configuration mode is activated when the sensor is switched on. For safety reasons, this mode is exited automatically 30 minutes after the
last setting has been made, and the connection between the remote control and the sensor is interrupted.
The connection can be re-established in one the following ways:
- Pressin a button on the sensor OR
- Interruptin the electrical power supply to the sensor OR
- Using the "access code" function on the remote control (only available on some sensor models)
Please refer to the sensor user manual for more information.
Quality
international
level
EN ISO
9001
Transmitter/receiver (infrared)
Status indicator LED
Safety curtain infrared spot detector
Numerical keys (1 to 9)
2” (5 cm) spacing for safety curtain infrared spot finder
Function keys (A to F)
Start button - power on (2 sec) & establish connection
Battery compartment
Battery compartment cover
Quick reference guides
(stored in slot on battery compartment cover)
General information
1
A
B
C
D
F
A
B
C
D
F
G
H
E
H
Page 1
I
J
E
G
I
J
BTurns beeper function on/off (hold for 2 sec) F
12
Scans for available addresses/sensors (hold for 2 sec)
On/Yes (only for certain parameters) Off/No (only for certain parameters)
The RC Duo 2 must be powered on before it can communicate with the sensor.
POWER ON: Press and hold Gfor 2 seconds
POWER OFF*:Press and hold Gfor 2 seconds
*The remote will automatically turn off after 2 minutes if no button is pressed.
Power ON: Press Gfor 2 sec
Ensure remote is
powered on (section 2)
and sensor is in confi-
guration mode (section
3.1)
Once Gblinks, press
Gagain to establish
connection.
To address the desired
parameter
EXAMPLE: mounting
height - F4
Press Fimmediately
followed by 4
2
1
The sensor ack-
nowledges it’s current
set value by illumina-
ting it on the keypad.
EXAMPLE:
4= 13-16 ft (4- 4.9 m),
factory default
The new setting is im-
mediately saved and
displayed on the key-
pad.
Programming of this
parameter is now
complete. Repeat for
other parameters.
Establishing connection with the sensor
3.1
Setting sensor parameters
3.2
Now press desired
new value.
EXAMPLE: 10-13 ft
(3.0-3.9 m) -3)
Press 3
The RC Duo 2 functions bidirectionally with the sensor. This means that changes to the settings on the sensor are immediately signalled back
by the sensor to the remote control.
EXAMPLE: the steps for setting the Hercules sensor mountin hei ht (parameter F4) are shown below:
Parts of the remote
1.1
Shortcut buttons
1.2
2’’ (5 cm)
The sensor’s ad-
dress illuminates on
the keypad.
EXAMPLE: address
1(factory default)
Note: If any keys are blinking, programming failed. In this case, repeat programming.

US01 006 05/12
Technical data
Technology: Active infrared, 40 kHz
Operating temperature: -20°C to 40°C
6
Status Display Beeper function
(if turned on - see section 4.2)
No Safety curtain spot detected reen No beeping
Safety curtain spot detected Red Constant beeping
Declaration of conformity
7
Bircher Re lomat
870 Pratt Avenue N
Schaumburg, IL 60193
Phone: 847-952-3730
Toll-Free: 800-252-1272
Fax: 847-952-2005
Email: [email protected]
Web: www.bircherreglomat.com
Manufacturer: Bircher Reglomat A , Wiesengasse 20, CH-8222 Beringen, Switzerland, www.bircher-reglomat.com
Importer: Bircher America, Inc. 870 Pratt Ave N, Schaumburg, IL 60193, USA, www.bircherreglomat.com
Standards taken into account: EN 61000-6-2, EN 61000-6-3
Important note: Bircher Reglomat reserves the right to change any information in this document without notice.
For the latest version, please visit www.bircherreglomat.com or call 800-252-1272 to request a copy.
Use sensor scan mode to determine available sensor addresses.
Use the 2” width mark on the RC Duo 2 to determine e.g. when the infrared
safety curtain is 2” from the face of a sliding door.
2” (5 cm)
Beeper function
4.2
LED Green Red
On Continuously Idle Safety curtain spot detected
Blinkin Low battery Safety curtain spot detected AND low battery
BEEPER ON: Press and hold Bfor 2 seconds
BEEPER OFF*:Press and hold Bfor 2 seconds
Remote must be turned on to access beeper function
*Beeper function turns off when remote turns off. This setting must be
re-activated each time the remote is turned on.
Sensor scan mode
4.3
LED indicator
4.1
Safety curtain spot detector
4.4
Additional functions
4
Max. air humidity: 90%, non-condensing
Batteries: 3 AAA (1.5 V) batteries
Press Ffor 2 seconds to
enter sensor scan mode.
All addresses assigned to
sensors in proximity are illu-
minated on the keypad.
The active address is now
illuminated on the keypad.
Select the corresponding ad-
dress to establish communi-
cation with a specific sensor.
Safety instructions
5
Only use this remote for it’s intended purpose.
Do not point the IR beam towards your eyes or those of others!
Observe all national and international door safety regulations.
Only trained, qualified personnel may install sensors.
This unit may only be opened and repaired by Bircher Reglomat.
Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system.
The installer is responsible for carrying out a risk assessment and installing sensors and door systems correctly.
Page 2