US01 006 05/12
Technical data
Technology: Active infrared, 40 kHz
Operating temperature: -20°C to 40°C
6
Status Display Beeper function
(if turned on - see section 4.2)
No Safety curtain spot detected reen No beeping
Safety curtain spot detected Red Constant beeping
Declaration of conformity
7
Bircher Re lomat
870 Pratt Avenue N
Schaumburg, IL 60193
Phone: 847-952-3730
Toll-Free: 800-252-1272
Fax: 847-952-2005
Web: www.bircherreglomat.com
Manufacturer: Bircher Reglomat A , Wiesengasse 20, CH-8222 Beringen, Switzerland, www.bircher-reglomat.com
Importer: Bircher America, Inc. 870 Pratt Ave N, Schaumburg, IL 60193, USA, www.bircherreglomat.com
Standards taken into account: EN 61000-6-2, EN 61000-6-3
Important note: Bircher Reglomat reserves the right to change any information in this document without notice.
For the latest version, please visit www.bircherreglomat.com or call 800-252-1272 to request a copy.
Use sensor scan mode to determine available sensor addresses.
Use the 2” width mark on the RC Duo 2 to determine e.g. when the infrared
safety curtain is 2” from the face of a sliding door.
2” (5 cm)
Beeper function
4.2
LED Green Red
On Continuously Idle Safety curtain spot detected
Blinkin Low battery Safety curtain spot detected AND low battery
BEEPER ON: Press and hold Bfor 2 seconds
BEEPER OFF*:Press and hold Bfor 2 seconds
Remote must be turned on to access beeper function
*Beeper function turns off when remote turns off. This setting must be
re-activated each time the remote is turned on.
Sensor scan mode
4.3
LED indicator
4.1
Safety curtain spot detector
4.4
Additional functions
4
Max. air humidity: 90%, non-condensing
Batteries: 3 AAA (1.5 V) batteries
Press Ffor 2 seconds to
enter sensor scan mode.
All addresses assigned to
sensors in proximity are illu-
minated on the keypad.
The active address is now
illuminated on the keypad.
Select the corresponding ad-
dress to establish communi-
cation with a specific sensor.
Safety instructions
5
Only use this remote for it’s intended purpose.
Do not point the IR beam towards your eyes or those of others!
Observe all national and international door safety regulations.
Only trained, qualified personnel may install sensors.
This unit may only be opened and repaired by Bircher Reglomat.
Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system.
The installer is responsible for carrying out a risk assessment and installing sensors and door systems correctly.
Page 2