General
Blueair 500/600 series
Blueair 500/600 series air purifiers are Wi-Fi
enabled and are available in two models. The
680i/690i/580i/590i models have built-in
sensors for PM2.5, VOC, temperature/humidity,
and the 605/505 models with no built-in sensors.
Adjustments to the air purifiers can be made
manually anywhere and at any time, either via
the touch buttons on the control panel located
under the flip-up lid, or remotely via the Blueair
FriendTM mobile app.
The air purifier can also be automatically
regulated based on the air quality readings from
the built-in sensors (680i/690i/580i/590i), or
the optional external air quality monitor Blueair
AwareTM (605, 505)
For more information on how to use your air
purifier together with the Blueair Aware air
quality monitor, please see the Blueair Aware
owner’s manual and the support information.
605/505 model680i/690i/580i/590i model
Wi-Fi FILTER AUTO PM 2.5VOC
Wi-Fi
FILTER

5
2
1
3
6
7
10
11
9
5
4
8
Adjusting fan (air flow) speed
Please refer to the table below to see the dierent options available for controlling your air purifier.
Overview of unit
Maximum speed is recommended for fast initial cleaning, during the day or when the air is heavily
polluted. Minimum speed is recommended for nighttime use.
1. Control panel
2. Blue LED
3. Front cover
4. Air inlet
5. Air outlets
6. Sensor placement
(680i/690i/580i/590i)
7. Back view
(580i/590i/505)
8. Back view
(680i/690i/605)
9. Particle filter, or
10. SmokestopTM filter
11. Kit box
- welcome card
- user manual
Control options 680i/690i/580i/590i 605/505
Manual control via touch buttons on control panel
Remotely via the Blueair Friend mobile app.
Automode based on air quality readings from the built in
sensors. This function may be activated either via the
touch button on the control panel or via the Blueair
Friend mobile app.
Automode based on air quality readings from the external
air quality monitor Blueair Aware. This function is
activated via the Blueair Friend mobile app.
Min Speed 1 Speed 2 Max Speed 3
Min Speed 1 Speed 2 Max Speed 3

6
Safety information
The Blueair 605/505 and 680i/690i/580i/590i air purifiers are electrical appliances. Please read the
safety instructions before use and take the necessary precautions to reduce the risk of fire, electric
shock or injury.
The Blueair Limited Warranty applies only if the unit is used according to these instructions.
WARNING: Indicates a hazardous situation that, if not avoided, could result in death or
serious injury.
CAUTION: Indicates a hazardous situation that, if not avoided, could result in minor or
moderate injury.
General
WARNING: To avoid a hazard, a damaged supply cable must always be replaced by the
manufacturer, service agent or similarly qualified person.
Use the grounded power cable provided with your Blueair air purifier unit to plug directly
into an appropriate, grounded electrical outlet. (Refer to the rating label on your unit)
Do not alter the plug in any way.
Intended use
CAUTION: Supervise children to ensure that they do not play with the appliance.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Hereby, Blueair AB, declares that the radio equipment type YXXZ-CC is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the
following internet address: www.blueair.com/customer-support

7
WARNING: Changes or modifications to this unit not expressly approved by the party responsi-
ble for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
FCC ID: 2AEX3-5XXZ-CC/2AEX3-6XXZ-CC
IC: 20267-505/IC: 20267-605
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment o and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause
undesired operation.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-003.
FCC RF Radiation Exposure Statement Caution: This Transmitter must be installed to provide a
separation distance of at least 20 cm from all persons.

8
4 ins
10 cm
Place the unit in a location where air can
circulate freely in, out and around the unit.
Do not place the unit closer than 4” (10 cm)
from another object.
Do not place the unit directly on or against
soft furnishings such as bedding or linen.
Do not place the unit near sources of heat,
such as radiators, fireplaces or ovens.
Do not place the unit near wet areas, such
as bathrooms or laundry rooms where it
may come into contact with water.
Do not place the unit outdoors
Step 1
Plug the fixed power cable into a
grounded wall outlet. If you have a unit
with a removable power cable, then
plug the cable firmly and completely
into the recessed power cable socket
located at the bottom of the unit
before plugging the other end of the
power cable into a grounded wall
outlet.
Step 2
Download the Blueair Friend mobile app to your smartphone from your app store (Apple App Store
or Google Play).
Step 3
Connect your unit to your Blueair Friend mobile app. Start the app and follow the instructions.
After connecting your air purifier to the Blueair Friend mobile app, you can use the app to control
the unit remotely and adjust settings.
Getting started
Connecting your air purifier - 680i/690i/580i/590i, 605 and 505
Follow the instructions below to connect your air purifier to your Blueair Friend mobile app. You can
then enable remote control.
Placing the unit
Blinking
Wi-Fi FILTER
Blinking
Wi-Fi AUTOFILTER PM 2.5
VOC
Open the flip-up lid and press the airflow speed touch button. When the Wi-Fi symbol starts to blink,
the air purifier can be paired with the Blueair Friend mobile app.

9
Control panel and touch buttons
The control panel and touch buttons are located under the flip-up lid (see Step 2 “Starting up the
unit”). A grey circle around a touch button indicates that it is inactive. When the unit is turned on, all
touch buttons except the air flow speed control button, dim down after 20 seconds. Tap the control
panel and the touch buttons will light up again.
Status “blinking” - no connection.
Wi-Fi ready to be connected.
Wi-Fi
Status grey - OFF (no Wi-Fi)
Air flow speed control
Status grey - OFF
Status blue and all bars are grey -
the power cable is plugged in.
Status grey and blue
Wi-Fi connected
Filter
Status grey and blue - no replacement
filter currently needed.
Status orange - replace filter and
reset by pressing down for 5 seconds.
Status 1 blue bar - minimum speed
Status 2 blue bars - medium speed
Status 3 blue bars - maximum speed
Classic 605/505 control panel touch buttons
Wi-Fi
FILTER

10
Blueair Friend mobile app settings
Please note that you must first add your air purifier unit to the Blueair Friend mobile app before you
can control the following settings via the app:
Adjust airflow speed
Changes the fan speed between speed 1, 2 and 3.
Adjust LED intensity
Changes the LED intensity for those lamps that are visible.
Child lock
Regulates your ability to control the air purifier unit via the control panel on the unit.
Auto mode
Automatically controls the fan speed based on readings either from the built-in sensors
(“i”models only), or from the external air quality monitor Blueair Aware.
Night mode
Allows the activation/deactivation of certain settings at specific times.
Auto speed
Status circle blue - unit is on
Status symbol grey - Auto speed OFF
Status symbol blue - Auto speed ON
PM2.5 indicator
Status blue - from excellent to
moderate pollution levels.
Status orange - from slight to high
pollution levels
VOC indicator
Status blue - from excellent to
moderate pollution levels
Status orange - from slight to high
pollution levels
Wi-Fi AUTOFILTER PM 2.5
VOC
Classic 680i/690i/580i/590i control panel touch buttons
See Blueair Friend mobile app for further information regarding pollution and threshold
levels

11
Filters
General information
The unit is delivered with three HEPASilentTM filters already installed.
Particle filters remove:
Carbon based filters remove all the above pollutants, plus:
SmokeVOC ChemicalsCooking
odors
IMPORTANT! Use only genuine Blueair filters to ensure proper function of your unit and to
qualify for full warranty coverage.
Blueair filter subscription program
This convenient service is available in some countries – contact your local Blueair retailer to find out
if you can join.
Model number
Serial number
Retailer’s name
Retailer’s address
Date of purchase Telephone number
Filter checklist
To make it easy to find the right filter in the future, please fill in the customer record below and keep
this user manual for reference. The model number and serial number of this product can be found
on the rating label on the bottom of the unit.
DustPM2.5 Pet danderMold Dust mitesBacteria/
Virus
Pollen

12
Changing the filters
Step 2
Remove the top filter.
Step 1
Remove the lid.
(see “Care and
Maintenance” step 1).
Step 4
Insert both replace-
ment Blueair filters
into the side slots.
Ensure the words
out/up face outwards.
Step 3
Remove both side
filters. (see “Care and
Maintenance” steps 2
and 3).
Step 5
Insert the third re-
placement Blueair fil-
ter into the top of the
unit. Ensure the words
out/up face upwards
Step 6
Snap the lid back into
place and plug into
the mains.
The unit is now ready
for use.
IMPORTANT!
Always turn o and disconnect the unit from the supply mains before changing filters, cleaning
or carrying out maintenance procedures..
Status orange - replace filter and
reset by pressing down for 5 seconds.

13
Care and maintenance
We recommend routine cleaning in order to keep your unit in top condition.
When changing filters
1. Wipe clean the underside of the lid after removal.
2. Vacuum the air inlet grille from the inside using a soft brush and/or other suitable attachment.
3. Vacuum the small air inlets with a soft brush attachment.
General
1. Wipe the exterior of the unit with a soft, clean, damp cloth.
2. Never clean with gasoline, chemical solvents or corrosive material as these agents may damage
the surface.
3. Do not allow foreign objects to enter the ventilation or exhaust openings. This may cause
electric shock or damage the unit.
4. Do not try to repair or adjust any of the electrical or mechanical functions on your Blueair unit
yourself. Contact your local dealer or Blueair for warranty information.
Environment protection:
Let’s protect the environment!
Our products and packaging are sustainably designed and made from recyclable materials. Do not
discard the filter or the product with household waste. Bring it to the nearest ocial waste recycling
service.
Help and support
If you have questions about Blueair Classic series, please visit www.blueair.com or contact your local
Blueair retailer.
Warranty information
The Blueair Limited Warranty applies only if the unit is used according to the instructions in this
manual.

14
Classic 680i/690i/605 technical specifications*
CADR (cfm)**:
Room size 775 sq.ft. (72 m2)
Air Changes per Hour *** 5
Airflow (Speed 1-2-3) 150-275-650 cfm
Size (HxWxD): 26 x 20 x 13 in. (660 x 500 x 340 mm)
Product weight: 35 lbs (16 kg)
Energy consumption
(Speed 1-2-3)****
15-65-100 W
Operating frequency: 2412-2472 MHz
Output power: 13.69 dBm
Sound pressure levels (Speed 1-2-3) 33-44-62 dB(A)
Filter replacement indicator Yes
Speed control options 1-2-3, non-touch, smartphone (Automode)
1-2-3, non-touch, smartphone
Air quality sensors Built-in sensors for VOC, PM2.5, temperature and humidity
No sensors - optional use with Blueair Aware
The entire unit can be recycled.
External network issues aecting the product performance are beyond the control of Blueair. Please contact your
Internet service provider for assistance.
*
**
***
****
Specifications based on U.S. models (120 VAC, 60 Hz with particle filter)
The CADR indicates how much filtered air is delivered (airflow) by the air purifier operating at the highest
setting, and how well the system removes tobacco smoke, dust and pollen pollutants from the air
(eciency). Tests are performed in accordance with ANSI/AHAM AC-1. The maximum possible CADR
ratingsaccording to this standard are: Tobacco Smoke: 450 cfm. / Dust: 400 cfm. / Pollen: 450 cfm.
Air changes per hour are calculated on the recommended room size, assuming 8-foot (2.4 m) ceilings.
Forsmaller rooms, the air changes per hour will increase.
The available electrical power voltage and frequency aects the power consumption of the unit.
Thepower consumption might therefore be dierent from the stated value.
680i/690i
605
680i/690i
605
Dust Pollen
Smoke
500 640500

15
Classic 580i/590i/505 technical specifications*
CADR (cfm)**:
Room size 698 sq.ft. (65 m2)
Air Changes per Hour *** 5
Airflow (Speed 1-2-3) 130-240-520 cfm
Size (HxWxD): 26 x 20 x 13 in. (660 x 500 x 340 mm)
Product weight: 35 lbs (16 kg)
Energy consumption
(Speed 1-2-3)****
15-65-100 W
Operating frequency: 2412-2472 MHz
Output power: 13.69 dBm
Sound pressure levels (Speed 1-2-3) 33-44-62 dB(A)
Filter replacement indicator Yes
Speed control options 1-2-3, non-touch, smartphone (Automode)
1-2-3, non-touch, smartphone
Air quality sensors Built-in sensors for VOC, PM2.5, temperature and humidity
No sensors - optional use with Blueair Aware
The entire unit can be recycled.
External network issues aecting the product performance are beyond the control of Blueair. Please contact your
Internet service provider for assistance.
*
**
***
****
Specifications based on U.S. models (120 VAC, 60 Hz with particle filter)
The CADR indicates how much filtered air is delivered (airflow) by the air purifier operating at the highest
setting, and how well the system removes tobacco smoke, dust and pollen pollutants from the air
(eciency). Tests are performed in accordance with ANSI/AHAM AC-1. The maximum possible CADR
ratingsaccording to this standard are: Tobacco Smoke: 450 cfm. / Dust: 400 cfm. / Pollen: 450 cfm.
Air changes per hour are calculated on the recommended room size, assuming 8-foot (2.4 m) ceilings.
Forsmaller rooms, the air changes per hour will increase.
The available electrical power voltage and frequency aects the power consumption of the unit.
Thepower consumption might therefore be dierent from the stated value.
Dust Pollen
Smoke
450 450400
580i/590i
505
580i/590i
505

16

17
Prije upotrebe proizvoda iz serija Blueair Classic 500 i600 pažljivo pročitajte ovaj korisnički priručnik.
Sadržaj
Općenito 18
Pregled jedinice 19
Podešavanje brzine ventilatora (protoka zraka) 19
Sigurnosne upute 20
Postavljanje jedinice 22
Upute za početak rada 22
Upravljačka ploča idodirne tipke 23
Postavke mobilne aplikacije Blueair Friend app 24
Filtri 25
Promjena filtara 26
Zaštita iodržavanje 27
Tehničke specifikacije uređaja Classic 680i/690i/605 28
Tehničke specifikacije uređaja Classic 580i/590i/505 29
Hrvatski
Napomena:
Mogu postojati lokalne varijante ovog modela.

18
Općenito
Serije Blueair 500/600
Pročišćivači zraka iz serija Blueair 500/600 imaju
funkciju Wi-Fi idostupni su udva modela.
Modeli 680i/690i/580i/590i imaju ugrađene
senzore za PM2,5, HOS, temperaturu/vlažnost,
dok modeli 605/505 nemaju ugrađene senzore.
Podešavanje pročišćivača zraka može se napraviti
ručno bilo gdje iubilo kojem trenutku, ili putem
dodirnih tipki na upravljačkoj ploči smještenoj
ispod preklopnog poklopca ili na daljinu putem
mobilne aplikacije Blueair FriendTM app.
Pročišćivač zraka također se može automatski
regulirati na temelju očitanja kvalitete zraka
izugrađenih senzora (680i/690i/580i/590i)
ilidodatnog vanjskog monitora za kvalitetu
zrakaBlueair AwareTM (605, 505)
Za više informacija otome kako upotrebljavati
pročišćivač zraka zajedno smonitorom kvalitete
zraka Blueair Aware pročitajte korisnički
priručnik iinformacije opodršci.
Model 605/505Model 680i/690i/580i/590i
Wi-Fi FILTER AUTO PM 2.5VOC
Wi-Fi
FILTER

19
2
1
3
6
7
10
11
9
5
4
8
Podešavanje brzine ventilatora (protoka zraka)
Provjerite tablicu unastavku za različite opcije dostupne za upravljanje pročišćivačem zraka.
Pregled jedinice
Maksimalna brzina preporučuje se za brzo početno čišćenje, tijekom dana ili kada je zrak jako
zagađen. Minimalna brzina preporučuje se za upotrebu tijekom noći.
1. Upravljačka ploča
2. Plavo LED svjetlo
3. Prednji poklopac
4. Ulazni otvor zraka
5. Izlazni otvor zraka
6. Postavljanje senzora
(680i/690i/580i/590i)
7. Prikaz straga
(580i/590i/505)
8. Prikaz straga
(680i/690i/605)
9. Filtar čestica ili
10. filtar SmokestopTM
11. Komplet
– kartica dobrodošlice
– korisnički priručnik
Opcije upravljanja 680i/690i/580i/590i 605/505
Ručno upravljanje putem dodirnih tipki na upravljačkoj ploči
Na daljinu putem mobilne aplikacije Blueair Friend app.
Automatski način koji se temelji na očitanjima kvalitete zraka
iz ugrađenih senzora. Tu je funkciju moguće aktivirati putem
dodirne tipke na upravljačkoj ploči ili putem mobilne
aplikacije Blueair Friend app.
Automatski način temelji se na očitanjima kvalitete zraka
svanjskog monitora kvalitete zraka Blueair Aware. Ta se
funkcija aktivira putem mobilne aplikacije Blueair Friend app.
Min Speed 1 Speed 2 Max Speed 3
Min Speed 1 Speed 2 Max Speed 3

20
Sigurnosne upute
Blueair 605/505 i680i/690i/580i/590i pročišćivači zraka električni su uređaji. Pročitajte sigurnosne
upute prije upotrebe ipoduzmite potrebne mjere opreza kako biste smanjili rizik od požara,
strujnogudara ili ozljeda.
Ograničeno jamstvo društva Blueair primjenjuje se samo ako se jedinica upotrebljava uskladu
sovim uputama.
UPOZORENJE: Ukazuje na opasnu situaciju koja bi, ako se ne izbjegne,
mogla rezultirati smrću ili teškim ozljedama.
OPREZ: Ukazuje na opasnu situaciju koja bi, ako se ne izbjegne,
moglarezultirati blagim ili umjerenim ozljedama.
Općenito
• UPOZORENJE: Kako bi se izbjegla opasnost, oštećeni kabel za napajanje
uvijekmora zamijeniti proizvođač, servisni agent ili druga kvalificirana osoba.
• Upotrebljavajte uzemljeni kabel za napajanje koji ste dobili sBlueair
pročišćivačem zraka da biste ga izravno priključili uodgovarajuću uzemljenu
električnu utičnicu. (Provjerite oznaku energetske učinkovitosti na jedinici)
• Nemojte mijenjati utikač ni na koji način.
Namjena
• OPREZ: Pripazite da se djeca ne bi igrala uređajem.
• Ovaj uređaj nije namijenjen osobama (uključujući djeci) sa smanjenim fizičkim,
osjetilnim ili mentalnim sposobnostima ili nedostatkom iskustva iznanja osim
ako su pod nadzorom ili su dobili upute koje se odnose na upotrebu uređaja
od osobe koja je odgovorna za njihovu sigurnost.
Ovim putem Blueair AB izjavljuje da je vrsta radijske opreme YXXZ-CC uskladu sDirektivom
2014/53/EU. Cjeloviti tekst EU izjave osukladnosti dostupan je na web stranici unastavku:
www.blueair.com/customer-support
Other manuals for Classic 500 Series
4
This manual suits for next models
7
Table of contents
Languages:
Other Blueair Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Pentair
Pentair FLECK 9100 SXT Installer manual

Watts
Watts WHOF2 installation manual

Culligan
Culligan CSM Series Installation, operating and service instructions

SuperFish
SuperFish Combi Clear user manual

Ispring
Ispring WF Series Installation instructions operations manual

Fahl
Fahl LARYVOX O2 CONNECT Instructions for use