Body Clock Health Care SensaTONE for Men User manual

11
9
0120
July 2016 (3)
Body Clock Health Care Ltd
108 George Lane, South Woodford
London E18 1AD
Tel (+44) (0)20 8532 9595
Fax (+44) (0)20 8532 9551
www.bodyclock.co.uk
e-mail [email protected].uk
For accessories and consumables please visit
www.bodyclock.co.uk
This manual is recyclable
SensaTONE
for Men
Instructions for use
Using Your Sensa ONE
for Men For PFS
PFS - Pelvic Floor Stimulation
a) Switch the unit on by pressing
the Power ey button. The
SensaTONE for Men will
always start up in Mode A.
b) The SensaTONE for Men has
four preset programmes:
Mode A - Urge Incontinence
Mode B - Stress Incontinence
Mode C - Mixed Incontinence
Mode D - After Care
c) Select the mode most
appropriate for your type of
incontinence by pressing the
‘MODE’ key. Please refer to
page 9 if you are unsure of
which mode to use.
d) Now begin by pressing the
‘Intensity Up’ key. Each time
you press this key, you will see
the intensity level increase on
the LCD.
e) Carefully continue to press the
‘Intensity Up’ key until you
comfortably feel your muscles
contracting. If the sensation
feels too strong, simply press
the ‘Intensity Down’ key to
minimise the feeling.
f) Modes A, B and C all have
fixed programme times. The
SensaTONE for Men will
automatically switch off once
the programme is complete.
Mode D does not have a fixed
programme time. Refer to
page 9 for more information
about Mode D.
g) After use, always remember to
ensure that the SensaTONE for
Men is switched off, then
remove the SensaTONE for
Men probe from your body.
Disconnect the leads and then
clean it in accordance with the
instructions found on page 6
or in the SensaTONE for Men
probe instruction manual.
8
Choosing he Right Mode
There are three types of
incontinence, all of which can be
treated with the SensaTONE for Men:
1. Urge incontinence (MODE A) -
occurs with a strong, sudden
and uncontrollable urge to
urinate.
2. Stress incontinence (MODE B) -
occurs when sneezing,
coughing, laughing, lifting or
during exercise and causes a
small amount of urine to leak.
3. Mixed incontinence (MODE C) -
a combination of urge and
stress incontinence.
Frequency Of Use
Below is a guide showing how
often to use each PFS mode on
your SensaTONE for Men. If your
muscles start to ache, or you
have any problems using the
SensaTONE for Men, please
contact your medical adviser.
Using Mode D – After Care
This is an optional mode and can
be used either directly after
treatment (provided you are not
experiencing any muscle fatigue),
or, as a maintenance mode after
you have been using your unit on a
regular basis and have experienced
an improvement in your condition.
NB. There is no recommended
treatment time for Mode D. It is
at your discretion. It is suggested
that it is used no more than
15-30 minutes per day.
Using the Sensa ONE
for Men for Faecal
(Bowel) incontinence
or Nocturnal Enuresis
The Sensatone for Men can be
used for these conditions, but you
must consult with a medical
adviser to determine the best
treatment mode prior to use.
PFS - Frequently Asked
Questions
QHow long will it take to see
results?
A The amount of time varies
from man to man; it is also
dependent on the type of
incontinence from which you
are suffering.
S RESS Incontinence -
improvement comes
slowly with the building
of muscle fibre and
nerve sensitivity. This can
take up to 2 months.
URGE Incontinence -
improvements are made by
reducing the false signals
sent by the bladder to the
brain. Results can be seen
in as little as 14 days.
MIXED Incontinence -
improvements are made
by building the muscle fibre
and nerve sensitivity as well
as reducing the false signals
being sent to the brain. This
can take slightly longer, but
you should be able to notice
a difference within 21 days.
QWhat does it feel like?
A All three PFS programmes feel
slightly different. In general,
the feeling is that of a pleasant,
tingly, squeezing sensation
that contracts and relaxes the
pelvic floor muscles.
QIs it suitable for use by all men?
A Yes, all men can use it
provided none of the
contraindications apply.
QCan you use the Sensatone
for Men for Faecal (Bowel)
incontinence or Nocturnal
Enuresis?
A Yes, but you must consult with
your medical adviser to
determine the treatment mode
which will best suit your needs.
QAre there any side effects?
A No, it is totally drug free.
There are no known
side effects.
Before first use of the
SensaTONE for Men,
please familiarise
yourself with the
‘Precautions and
Contraindications’
contained on page 4.
The SensaTONE for Men
should NO be used if
suffering from a urinary
or bowel infection or
tissue damage or if
you have a recent local
surgical scar.
Programme
Mode A
Mode B
Mode C
Mode D
Length
30 mins
30 mins
45 mins
–
How often
1-2 times a day
Complete the programme once a day
Once a day or every other day depending on severity
Please see ‘Using Mode D’ above
DO NO EXCEED REA MEN IMES UNLESS ADVISED BY A MEDICAL PROFESSIONAL.
10
Programme Display Output Frequency/Duration
5Hz / 3 mins 10Hz / 5 mins 15Hz / 5 mins
20Hz / 5 mins 15Hz / 5 mins
10Hz / 5 mins 5Hz / 2mins
otal time = 30 mins
Urge A
10Hz / 5 mins 35Hz / 5 mins 50Hz / 10mins
35Hz / 5mins 10Hz / 5mins
otal time = 30 mins
Stress B
10Hz / 5mins 20Hz / 5 mins 30Hz / 5 mins
40Hz / 5mins 50Hz / 5mins 40Hz / 5mins
30Hz / 5mins 20Hz / 5mins 10Hz / 5mins
otal time = 45 mins
Mixed C
Frequency Modulation
Frequency increases from 2 Hz to 10 Hz in 4 secs.
and then back to 2Hz in another 4 secs.
otal cycle = 8 secs
otal time = 45 mins
After Care D
All outputs have 200µs pulse width. For the Urge, Stress and Mixed mode,
the output pulses are alternatively switched on and off for 5 seconds.
Specifications
Output Channel Single Channel
Output Waveform Bi-phasic rectangular
Output Voltage 0-40V adjustable in 14 steps across a 500 ohm load
Output Intensity 0-80mA adjustable in 14 steps across a 500 ohm load
Automatic Power Off 5 minutes
Battery 2 x 1.5v AAA Batteries
Battery Low Detect 2.2V±0.1V
TM
Guarantee
Your SensaTONE for Men is guaranteed for a period of 2 years
against manufacturer’s defects. Please record purchase details in
the space provided below for your record purposes. The guarantee
does not include leads, electrodes, probes or battery.
Date of purchase:
Invoice number:
If you have any further
questions on
incontinence or need
some advice, contact
The Bladder and Bowel
Foundation on:
Helpline: (+44) (0)845 345 0165
e-mail:
info@bladderandbowelfoundation.org
web:
www.bladderandbowelfoundation.org
Reg Charity
1085095
Se saTONE-MEN-I st-1-sheet-V3.qx8_(v) 01/07/2016 15:06 Page 1

4
5 6 7
he Sensa ONE for Men
from Body Clock is an
ultra simple, yet
powerful digital Pelvic
Floor Stimulator (PFS).
his compact, stylish
unit has been designed
for use by men of all
ages to help strengthen
pelvic floor muscles and
to treat incontinence.
Like all other muscles in your
body, the more you stimulate
them, the stronger they become.
Men with strong pelvic floor
muscles enjoy greater control
over their bladder.
One in seven men suffer from
some form of incontinence
during their life. It can occur
at any time. The severity of
incontinence can vary.
Before you use the SensaTONE
for Men, it is important that you
read this manual carefully; it
contains all of the information
you need to ensure you are using
the unit safely and correctly.
Explanation Of Symbols On Unit
Equipment providing a
particular degree of
protection against
electric shock
particularly regarding
allowable leakage
currents having a BF
type (floating) applied
part.
Warning – refer to
accompanying
documents i.e.
these instructions.
Please keep device
away from sprays of
water or rain.
Denotes a product
which must be
disposed of safely.
This symbol indicates
the serial number
of the device and
includes the year
of manufacture.
The serial number can
be found in battery
compartment of this
device and also on the
outer packaging.
2 3
Contents
Precautions And Contraindications ...................................................... 4
Controls On The SensaTONE for Men .................................................. 5
Display Symbols And Their Meanings .................................................. 5
Additional Functions ............................................................................ 5
Setting Up Your SensaTONE for Men .................................................... 6
Useful Diagrams .................................................................................. 7
Using Your SensaTONE for Men For PFS ................................................ 8
Choosing The Right PFS Mode ............................................................ 9
Frequency Of Use .................................................................................. 9
Using Mode D – After Care .................................................................... 9
PFS FAQ’s ............................................................................................ 10
Technical Specification ........................................................................ 11
Precautions And
Contraindications
1. Do NO use the SensaTONE for
Men if you have a cardiac
pacemaker.
2. Check with your medical
adviser before using if you
suffer from a heart condition,
undiagnosed pain, have any
metal implants, or any doubts
whatsoever.
3. Do NO use the SensaTONE for
Men if you are suffering from
any urinary or bowel infection.
4. Never use the SensaTONE for
Men to mask undiagnosed pain
since this could require urgent
treatment.
5. Do not use if suffering from an
infection or tissue damage or
if you have a recent local
surgical scar.
If you have any concerns regarding
use of the SensaTONE for Men
please do not hesitate to contact
Body Clock Health Care on
(+44) (0)20 8532 9595.
General Precautions
1. Do NO use this unit without
first reading these instructions.
2. Do NOT handle or insert probe
unless the unit is switched off.
3. Do NO immerse unit in liquid.
4. Do NO place it close to any
source of excessive heat or
operate it in the presence
of flammable gas.
5. Do NO drop this unit onto
a hard surface.
6. Do NO attempt to dismantle
the SensaTONE for Men.
7. Only use specified batteries
and electrodes.
8. If damaged, do not use.
Return to supplier.
9. Remove batteries when not in use.
10. Do NO use while driving or
operating potentially
dangerous machinery or while
using a microwave.
11. eep out of the reach of
children.
12. Do NO place the anal probe
near the eyes, in the mouth,
over the front or sides of the
neck, across the head, heart.
13. Do NO use in the presence
of tuberculosis, malignant
tumours, very high or low blood
pressure, high fever or acute
inflammatory disease unless
under medical supervision.
Controls On he Sensa ONE for Men
Power ey – Turns the SensaTONE
for Men on and off.
User Display – Indicates the mode in
use and the intensity level (also see
diagram below).
Mode ey – Switch between
programmes A, B, C and D.
Intensity Up – Increases the intensity
of the pulses.
Intensity Down – Decreases the
intensity of the pulses.
User Display
Additional Functions
Load Detector – If the anal probe becomes detached, the intensity will drop back
to zero.
Low Battery Indicator – A flashing battery symbol will be shown on the display.
Automatic Power Off – When the unit intensity levels are zero, and the
SensaTONE for Men has not been in use for approximately 5 minutes, the unit
will shut off automatically.
Indicates the
mode in use.
Indicates the
intensity level
of the pulses.
Low battery
indicator.
Setting Up Your
Sensa ONE for Men
Check you have the following
contents:
• 1 x SensaTONE for Men unit
• 1 x Anuform anal probe
• 1 x Leadwire
• 1 x Lubricant gel sachet
• 1 x Neck cord
• 1 x Instructions
NB. 2x AAA batteries NOT
included
he Assembly Stage
1. Ensure the SensaTONE for
Men unit is switched off.
2. Slide open the battery cover
on the back of the unit to
expose the battery
compartment.
3. Insert the batteries matching
the + and – terminals,
according to the diagram
found in the battery
compartment. Replace
the cover.
4. Remove the Anuform anal
probe from its packaging.
5. Wash hands in soap and
warm running water. Liberally
wash the probe using the
same method but do not
soak. Rinse all soap and
residue from hands and
probe. Dry your hands and
the probe with a clean
cloth/paper towel and allow
to air dry.
6. Insert the end of the leadwire
into the socket at the bottom
of the SensaTONE for Men.
Connect the pins to the other
end of the leadwire to the
Anuform probe. See diagram
(i) on page 7.
7. Apply a thin coating of
lubricating gel to the probe.
8. Insert the probe into the anus
while 'bearing down' as if
passing a stool. The 'RING'
part of the Anuform probe
should remain external to the
anus at all times.
There is no need for precise
orientation. See diagram (ii)
on page 7.
9. You are now ready to begin
stimulation.
bladder
urethra bowel
anus
Diagram (i)
Diagram (ii)
probe
Useful Diagrams
Important
• The Anuform anal probe is single patient use ONLY.
Additional probes and gel can only be purchased from Body Clock.
• Probes may be re-used by the same patient only.
• Wash probe as instructed before each use.
• Do NO use the probe if the pack is open or damaged.
This unit needs special precautions regarding EMC and
needs to be installed and put into service according
to the EMC information provided in the accompanying
Electromagnetic Information document.
SN
Se saTONE-MEN-I st-1-sheet-V3.qx8_(v) 01/07/2016 15:06 Page 2