manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bogen
  6. •
  7. Switch
  8. •
  9. Bogen CA10A User manual

Bogen CA10A User manual

The Bogen CA-Series Call-In Switches are attractive, functional units for call-in from classrooms or other staff
locations to Bogen’s PI35A and SI35A Intercom Systems, Multi-Graphic©Series 115B, 2223, and 2233
Institutional/School Communication Systems, and Multicom 2000®Administrative Communication Systems.
Specifications subject to change without notice.
© 2003 Bogen Communications, Inc.
Part No. 54-7858-02B Printed in U.S.A. 0312
Features
Description
Call-In Switches
Models
CA10A, CA11A, CA15C,
CA17, CA19, & CA21B
All Models
• Flush or surface mounted in standard single-gang
outlet boxes
• Heavy-duty long-life switches
• Color-coded connecting leads
• Brushed aluminum faceplate
• Mounting screws included
CA10A and CA11A
• Designed for use with the PI35A, SI35A and Multi-
Graphic Series 115B/2223/2233 systems
• SCR holding circuits actuate the annunciator signal
and LEDs in Bogen’s SBA-Series room selector
panels
• Provide momentary press-to-call
CA11A
• Offers a fixed privacy position to prevent unau-
thorized monitoring of the staff station from the
control center
• Privacy mode does not interfere with program or
intercom transmissions to the staff station (priva-
cy cannot be used with 2-wire call-in)
CA15C
• Designed for use with Multicom 2000 system staff
stations
• Provides momentary press-to-call functioning
• Can be used to initiate both “normal calls” and
“emergency calls”
CA17
• Designed for annunciator call-in for PI35A, SI35A,
and Multi-Graphic systems that are equipped with
the SCR25A module
• Momentary push-button switch (does not incor-
porate SCR circuitry)
CA19
• Designed for use in Multicom 2000 systems (does
not incorporate SCR circuitry)
• Provides press-to-call function at enhanced staff
stations that are equipped with the MCESS or
MCWESS telephone sets
• Contact Bogen’s Application Engineering
Department for CA19 supportive software
CA21B
• Designed for use in Multicom 2000 systems (no
SCR circuitry)
• Provides a press-to-call position and has a fixed
privacy position to prevent monitoring
• Can be used to initiate both “normal calls” and
“emergency calls”
The call-in switch shall be a Bogen Model ________ (spec-
ify CA10A, CA11A, CA15C, CA17, CA19, or CA21B), or
equivalent, designed for flush- or surface-mount installation
in a standard single-gang outlet box. It shall be mounted on
a brushed aluminum faceplate, 41/2" H x 23/4" W, with beveled
edges.The plate shall have two holes drilled to conform to
the positions of the tapped holes on the outlet box. Two
oval-head machine screws shall be supplied for mounting.
Use for all except CA17. The switch shall be furnished
with insulated, color-coded connecting leads, stripped and
tinned.
Use for CA10A. The switch shall be a two-position, rock-
er-type, single-pole, normally open switch, designed for use
with Bogen PI35A and SI35A systems, and Bogen Multi-
Graphic Series 115B, 2223, and 2233 systems.The depressed
position shall be momentary.When pressed, the switch shall
energize the corresponding annunciator lamp and the call-in
tone at the room selector panel, and shall maintain this con-
dition after the switch is released and until the call is
acknowledged by the operator. The holding action shall be
accomplished without the use of relays or other mechanical
devices.
Use for CA11A. The switch shall be a three-position,
rocker-type switch, designed for use with Bogen PI35A and
SI35A systems, and Bogen Multi-Graphic Series 115B, 2223,
and 2233 systems. It shall have two single-pole circuits that
are open in the normal center position, labeled TALK. One
circuit shall close when the switch is pressed downward, a
momentary position that energizes the corresponding
annunciator lamp and the call-in tone at the room selector
panel.This condition shall be maintained after the switch is
released and until the call is acknowledged by the operator.
The holding action shall be accomplished without the use of
relays or other mechanical devices. The other circuit shall
close when the switch is pressed upward to the fixed posi-
tion labeled PRIVACY. When the switch is in this position, it
shall be impossible for the system operator to monitor the
associated staff loudspeaker. However, this shall not affect
the transmission of program material or intercommunica-
tion from the control center to the loudspeaker (privacy is
not available with 2-wire call-in).
Use for CA15C. The switch shall be a two-position, rock-
er-type, single-pole, normally open switch, designed for use
with Bogen Multicom 2000 systems.The depressed position
shall be momentary. When pressed, the switch shall cause a
designated administrative phone to ring.When pressed four
times, it shall activate an “emergency call.”
Use for CA17. The switch shall be a two-position, push-
button type, single-pole, normally open switch. It shall be
designed for use with Bogen PI35A, SI35A, and Multi-
Graphic systems equipped with the Bogen SCR25A module.
The depressed, momentary position shall activate the corre-
sponding annunciator lamp and the call-in tone at the room
selector panel.
Use for CA19. The switch shall be a two-position, rocker-
type, single-pole, normally open switch, designed for use
with enhanced staff stations in Bogen Multicom 2000 sys-
tems. The depressed position shall be momentary. When
pressed, the switch shall cause a designated administrative
phone to ring.When pressed two times, it shall activate an
“emergency call.”
Use for CA21B. The switch shall be a three-position,
rocker-type switch, designed for use with Bogen Multicom
2000 systems. It shall have two single-pole circuits that are
open in the normal center position, labeled TALK. One cir-
cuit shall close when the switch is pressed downward, a
momentary position that shall cause a designated adminis-
trative phone to ring.When pressed three times, the switch
shall activate an “emergency call.” The other circuit shall
close when the switch is pressed upward to the fixed posi-
tion labeled PRIVACY. When the switch is in this fixed posi-
tion, it shall be impossible for an administrator to monitor
the associated staff loudspeaker. However, this shall not
affect the transmission of program material or intercommu-
nication to the loudspeaker.
50 Spring Street, Ramsey, NJ 07446
Tel. 201-934-8500 FAX: 201-934-9832, www.bogen.com
Architect and
Engineer
Specifications*
Application
Chart
Model Positions Function Action Used With
CA10A 2 Press-to-Call Momentary PI35A, SI35A, and MultiGraphic
115B, 2223, 2233 Systems
CA11A3Privacy
Press-to-Call
Fixed
Momentary
CA15C 2Press-to-Call
Emergency Call
Momentary
(4 Times)
Multicom 2000 Staff Stations
(Level 1,2,3)
CA172 Press-to-Call Momentary
PI35A, SI35A, MultiGraphic 115B,
2223, 2233 equipped with
SCR25A module
CA192 Press-to-Call Momentary Multicom 2000 Enhanced Staff
Stations (Level 4, 5, 6)
CA21B3Privacy
Press-to-Call
Fixed
Momentary
Multicom 2000 Staff Stations
(Level 1,23)
* Architect and Engineer Specifications are available on CD and
online in a Word document to assist you with preparing your bids.

This manual suits for next models

5

Other Bogen Switch manuals

Bogen Multi-Graphic SI35A User manual

Bogen

Bogen Multi-Graphic SI35A User manual

Bogen CA21B User manual

Bogen

Bogen CA21B User manual

Bogen CA15C User manual

Bogen

Bogen CA15C User manual

Bogen CA-10 User manual

Bogen

Bogen CA-10 User manual

Bogen CA10A User manual

Bogen

Bogen CA10A User manual

Bogen Nyquist NQ-E7020 User manual

Bogen

Bogen Nyquist NQ-E7020 User manual

Bogen CA-15B User manual

Bogen

Bogen CA-15B User manual

Bogen CA19 User manual

Bogen

Bogen CA19 User manual

Popular Switch manuals by other brands

GE 3-Device HDMI Switch quick start guide

GE

GE 3-Device HDMI Switch quick start guide

Raritan TeleReach TR361 user manual

Raritan

Raritan TeleReach TR361 user manual

KROHNE OPTISWITCH 5100 C Handbook

KROHNE

KROHNE OPTISWITCH 5100 C Handbook

IBM RS/6000 SP Service guide

IBM

IBM RS/6000 SP Service guide

Verbatim 49140 Quick install guide

Verbatim

Verbatim 49140 Quick install guide

Eminent EM1019 instruction manual

Eminent

Eminent EM1019 instruction manual

Bridgetek PANL Series datasheet

Bridgetek

Bridgetek PANL Series datasheet

LQ GROUP 1145616-00000 instruction manual

LQ GROUP

LQ GROUP 1145616-00000 instruction manual

Milestone pro MP-SC-12D-TN user manual

Milestone pro

Milestone pro MP-SC-12D-TN user manual

D-Link SmartPro DGS-1500-20 user manual

D-Link

D-Link SmartPro DGS-1500-20 user manual

Humminbird 531871-1_A Installation

Humminbird

Humminbird 531871-1_A Installation

ATEN VS482 user manual

ATEN

ATEN VS482 user manual

Digitus DS-12820 user manual

Digitus

Digitus DS-12820 user manual

Alloy GSS-16T4SFP user manual

Alloy

Alloy GSS-16T4SFP user manual

LevelOne FSW-1609TFX user guide

LevelOne

LevelOne FSW-1609TFX user guide

Pulsar RSFUPS116 quick start guide

Pulsar

Pulsar RSFUPS116 quick start guide

Raritan Dominion KX II-101-V2 user guide

Raritan

Raritan Dominion KX II-101-V2 user guide

Soldo Controls SIS Series manual

Soldo Controls

Soldo Controls SIS Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.