BOJKE ER2-22N User manual

ER2-22N
Dual number display fiber optic
sensor
Operating instruction
----------------------------------
Operation panel description:
Note:
To ensure your safety, please follow the following rules:
1. This product is only for target detection. Do not use this
product protects the human body or body parts, etc.
2. This product may not be used as explosion-proof products.
Do not use this product in hazardous locations and/or
environments with potentially explosive gases.
3. The product is DC - powered sensor. Do not use AC power.
Otherwise, the product will explode or catch fire.
4. Do not wire the amplifier along the power line or high
voltage cable. Otherwise, the sensor will fail or be damaged
due to noise.
5. When using commercial switching regulators, Be sure to
ground the frame grounding terminal and the grounding
terminal.
6. Do not use it outdoors or where external light can enter
the light receiving surface directly.
Technical specifications:
Type ER2-22N ER2-22P
Type NPN output PNP output
Power supply
voltage 12-24 VDC±10%, below floating P-P 10%
Current
consumption
mA less than 40
Light source
Red ,4-element luminescent diode
Testing mode
Diffuse reflection, ejection (determined
by fiber type)
Detection
distance
P-1 diffuse reflection 200 mm, vs 700 mm
P-2 diffuse reflection 280 mm,1200 mm
Detection
output
NPN collector open
circuit output,
maximum input
current 100 mA,
external maximum
voltage 30 VDC,
residual voltage
less than 1 V
PNP collector open
circuit output,
maximum input
current 100 mA,
external maximum
voltage 30 VDC,
residual voltage
less than 2 V
Output
status (D/L)5S for open/open switching
Delay
function
No delay / single output delay / pull high
delay / pull low delay, four output modes
are optional. Three time delays
adjustable :1 ms to 9999
Response
time
P--1: less than 100 uS P--2: less than
200 uS
LED display
red output indicator, threshold display (4
bits green LED), current value display (4
bits red LED)
Protection
circuit
Power supply polarity reverse protection;
output short circuit or overload
protection
Working
environment
brightness
Incandescent: maximum :20,000 lux,
daylight: maximum :30,000 lux
Vibration
Resistance
Double amplitude Hz,10 to 55:1.5 mm,X,Y,Z
axis 2 hours
Ambient
temperature
-℃25 to +55, no freeze

Output Circuit:
ER2-22N NPN model
ER2-22P PNP model
Dimensions :(mm)
Correct installation method:
mounted on DIN track
1. Align the card slot at the bottom of the
main engine with the track. Push the main
engine in the direction of arrow 1 and tilt
it in the direction of arrow 2.
2. The way to remove the sensor is, Moving in the direction of the arrow
1 to promote the host at the same time, towards
the direction of the arrow 3 host to ascend.
Mounted to wall (for main module only)
Place the modules on the optional mounting
rack, install them together, and secure them
with two M3 screws.
Connect optical fiber module
1. Open the dust cover in the direction
shown by arrow 1.
2. According to the direction of the arrow
2 down fiber lock bar.
3. Insert the length of the fiber optic
module mark marked optical fiber.
4. Move the fiber lock rod down in the direction shown by arrow 4.
5. If you use a thinner fiber optic module, you need to use the adapter
that comes with it.
6. If the correct adapter is not connected, the thin fiber module will
not be able to detect the target
correctly. (Adapters are provided
with fiber optic modules. )
7. If the coaxial reflective fiber
module is connected to the
amplifier, the single-core fiber should be connected to the transmitter
side, and the multi-core fiber should be connected to the receiver side.
Product Function Setting
1. Quick threshold setting:
2. Manually adjust the threshold:
After the threshold is quickly set, you can manually press the +
and - keys to fine-tune the green threshold. The principle of threshold
fine-tuning is: No red value of product exposure < green setting value
< red value of product exposure;
It is recommended that the red value of the product be more
than 20 larger than the green threshold;
Note: When the red value is less than 100 in P--1 mode, it is
recommended to use P--2.
3. Normally open/closed switch:
In front of the
optical fiber
products by a set
key products
each press the set
The first time you press set to display
set, Press set the second time to
display the set threshold. time to
display the set threshold.
Press to display L-on or
d-on,Long press display and
switch on/off normally, release
button 5 seconds automatically
return;
Press the + and – keys to
fine-tune the green
threshold
Short press show L - on or d - on,
Long press the display and switch
normally open/closed, loosen the
button for 5 seconds automatically
return;
Red current
value
Green
thresholdd
Output indicator
Reflection is often open, to
shoot normally closed:
l-on
A reflection that is
normally closed and
normally open: d-on.

4. P1P2 mode:
P--1:The biggest test show 4095 Suggest have a difference of more
than 50 products red value;
P--2:The biggest test show 9999 Suggest have a difference of more
than 80 products red value;
5.Output mode:
TOFF (close delay) : Product without any delay, normal output;
S-D( one-time output): After induction, regardless of the detection time,
only output a set delay time width signal;
d-o( pull-up delay): Delay output, product induction, delay to the set
time before output, after the product left off output; (no output if the
induction time is less than the set delay time)
o-d( pull-down delay): Output delay, output the set delay time width
signal after the product induction leaves;
6. The light intensity
d--3,d--2,d--1 light intensity gradually decreased;
7. Detection mode:
Detection mode Mod Description
STd Normal mode
AreA Regional detection
pattern
If AreA is selected in detection mode, it will be displayed when
exiting to the default state.
Area threshold 1 set:
Area threshold 2 set:
P1 or P2 mode display When P--1 or P--2 is
displayed and flashing, press
the + key and -key to switch
P--1 or P--2 mode.
The default state, long press
MODE key 3 seconds into
menu settings, display P-1 or
P--2 and flicker.
Once P1P2 mode is selected, press
the MODE several times to return
to the default state.
Output mode
shows:T0FF or
S-d or d-o or o-d
When T0FF or S-d or
d-o or o-d flashes,
press the + key and
-key to switch the
output mode.
The default state, long press
MODE key 3 seconds into the
menu settings, display P--1 or
P--2 and flicker, then short press
the MODE key again, display
T0FF or S-d or d-o or o-d and
flicker.
Time delay display (unit
mS); note: TOFF mode
can only be 0 and can
not be adjusted;
As the red number
flashes, press the +
key and -key to adjust
the delay time.
The delay time can be adjusted
if the S-d or d-o or o-d, are
selected to press the
corresponding red number
again to flicker. After setting
mode and delay time, press
MODE to return default status
many times.
Light intensity:
d--3 or d--2 or
d--1
Press and hold the MODE for three
seconds by default, after the
display P--1 or P--2, press the
MODE key a few times again until
the display d-3 or d-2 or d-1 and
flashes.
When d--3 or d--2 or
d--1 flashes, press the +
key and -key to switch
out the light intensity.
After selecting the light mode,
press the MODE several times to
return to the default state.
Press and hold the MODE3 key for
3 seconds in the default state, after
displaying the P mode and
flashing, press the MODE key a
few times again until the display
STd or AreA and flicker.
When displaying STd
or AreA and flashing,
press + key and -key to
switch detection mode.
After the detection mode is
selected, the default state is
returned by pressing the MODE
several times.
Area mode is
displayed AreA
default state
When the area mode displays
AreA in the default state, short
press the mode key, switch to
the ArE1 and ArE2 display, you
can set the threshold through the
SET、+ key ,-key
When the zone mode
displays a AreA by
default, or by pressing the
mode button, you can set a
threshold of 1 when
switching to the ArE1
Press + key and -
key to fine-tune
green threshold 1
Fibre-optic keys
are pressed once
each to detect set
object
Press the set button for SET,
first time
Press the set key for the
second time to display the
set area threshold 1.
When the area mode displays
the AreA in the default state,
press the mode key short,
switch to the ArE2 display can
set the threshold 2
Fibre-optic keys are
pressed once each
to detect set object
Press the set button for SET,
first time
Press the set key for the second
time to display the set area
threshold 2.

Note: the threshold value 1 and 2 are no matter
high or low, the product will automatically identify
the high threshold value and the low threshold value;
There is a step difference between threshold 1 and
2. When threshold 1 and threshold 2 are too close
to each other, the product automatically widens the
value difference between threshold 1 and threshold
2.
8. Detection frequency selection:
When multiple products are detected near each
other, different frequencies can be selected to
stagger and interfere with each other. Four
operating frequencies are available: F1, F2, F3 and
F4
9. Return to default:
In any menu mode, no action for 30 seconds automatically returns the
default state.
10. Restore factory Settings:
P mode: P--1 mode;
Output: TOFF didn't delay, normal output;
The light intensity: d - 3 the strongest light;
Detection mode: normal mode
Working frequency: F1
Normally open/closed, normally open (L - on);
11. Key lock and unlock:
12. Flip display of digital tube:
After the inversion, it is as follows:
menu function setting is
complete, display End,
press again MODE key to
return the default state.
By default, long press
MODE key to enter menu
settings. Menu mode, short
press the selection needs to
set the function, and then
short press several times to
exit the menu;
INIT, indicates that the
initial setting has been
restored, the key can be
loosened.
LOC indicates that the
key has been locked, the
key can be loosened.
Press MODE key, then press -
key, while holding down for 3
seconds, display LOC lock key.
UnL indicates that the
key has been locked, the
key can be loosened.
Press MODE key, then press -
key, while holding down for 3
seconds, display UnL unlock
key.
Click + key and
- key to
fine-tune green
threshold 2
Press and hold the MODE key for
3 seconds in the default state,
after displaying the P mode and
flashing, press the MODE key a
few times again, until the display
frequency F mode and flicker.
Frequency F mode
display
When displaying F
mode and flashing,
press + key and -key to
switch frequency F
mode.
Press MODE key, then press D/L
key, while holding down for 3
seconds, digital tube flip display.
Press the MODE key, then press
the SET key, and hold it down for
3 seconds to display INIT restore
factory Settings.

Product warranty
When ordering the company's products with reference to the
product samples, the following warranty contents,
disclaimers and applicable conditions shall be applicable
when there is no special description in the quotation sheet,
contract, specification, etc.
Please be sure to place your order after confirming the
following.
1. Shelf life
The shelf life is one year from the date the product is
delivered to the place specified by the buyer.
2. Ensure that the scope of
In the event of a breakdown of the goods purchased due to our
liability during the above warranty period, we are
responsible for repairing the products free of charge.
However, if the fault is caused by the following reasons, it
is not within the scope of the guarantee object:
Failure caused by use outside the conditions, environment and
methods of use described in our product specification
1) failure caused by using the product under conditions other
than the conditions, environment and usage described in the
company's product specifications
2) faults not caused by the company
3) Faults caused by alterations and repairs not made by the
company
4) The usage other than that described by the company is
carried out
5) After the goods are shipped, due to unforeseen scientific
level may cause problems
6) Other failures caused by natural disasters, disasters and
other factors not the responsibility of the company.
At the same time, the above warranty only refers to the
company's products themselves, and the damage caused by the
failure of the company's products is excluded from the
warranty object.
3. Liability is limited
1) The company shall not be liable for any special losses,
indirect losses or other related losses (equipment damage,
loss of opportunity, loss of profit) caused by the products
of the company.
2) When using programmable equipment, the company shall not
be liable for any programming performed by a person other than
the company or any consequences arising therefrom.
4. Suitable for use and conditions
1) The company's products are designed and produced for the
general industry, therefore, our company's products shall
not be used for the following applications and are not
suitable for their use. If it is needed for the following
occasions, please discuss with the sales personnel of the
company to confirm the product specifications and select the
product with certain leeway in rated · performance.
Meanwhile, various safety countermeasures should be
considered to minimize the risk of failure to the safety
circuit.
a. Facilities that have a serious impact on life and property,
such as atomic energy control equipment, incineration
equipment, railway, aviation and vehicle equipment, medical
equipment, recreational equipment, safety equipment and
equipment that must comply with the special regulations of
administrative agencies and individual industries.
b. Public utilities such as gas, water, electricity supply
system, 24 - hour continuous operation system and other
equipment requiring high reliability.
c. May endanger the personal property of systems, equipment
and devices.
d. Outdoor use under similar or similar conditions.
2) When users use the company's products for occasions
closely related to the safety of life and property, the danger
of the system as a whole should be clearly defined. To ensure
the safety, special redundancy design should be adopted. At
the same time, according to the applicable purpose of the
company's products in the system, supporting power
distribution and setting should be achieved.
3) Please be sure to comply with all precautions and
prohibitions to avoid improper use and damage caused by a
third party.
5. Service scope
The company's product price does not include the dispatch of
technical personnel and other service fees, if there is a
demand for this, you can contact to negotiate.
This manual suits for next models
1
Table of contents
Popular Accessories manuals by other brands

Leuze electronic
Leuze electronic HT25CL2 manual

Dometic
Dometic WAECO BordBar TB08 operating manual

Comunello Automation
Comunello Automation DART SLIM Installation and user manual

Thunderbird
Thunderbird T10 instruction manual

Datalogic
Datalogic S8-PR M53 Series instruction manual

Schulte Elektrotechnik
Schulte Elektrotechnik EVOline Quicklock PRO manual