Bosch Thermotechnik FILLING LINK User manual

[en] FILLING LINK for Combi Boiler
Installation and operating manual.................................................... 2
[de] SYSTEMTRENNER für Kombikessel
Installations- und Bedienungsanleitung............................................ 13
[es] FILLING LINK para caldera mixta
Manual de instalación y de funcionamiento....................................... 24
[fr] DISCONNECTEUR A REMPLISSAGE pour chaudière sol combinée
Manuel d’installation et d'utilisation................................................. 36
[it] COLLEGAMENTO ESTERNO per caldaia Combi
Manuale di installazione e funzionamento......................................... 47
[pl] ZESPÓŁ NAPEŁNIAJĄCY o kotła dwufunkcyjnego
Instrukcja montażu i eksploatacji..................................................... 60
6 720 884 379 (2018/03)

2
Contents
6720884379 (2018/03)
Contents
1 Symbols & safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Product information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Supplied parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4 Fitting and servicing the filling link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.1 Fitting and servicing the manual filling link . . . . . . . . . . . . . . . . . . . 7
4.2 Fitting and servicing the automatic filling link . . . . . . . . . . . . . . . . 8
5 Filling the system with manual filling link . . . . . . . . . . . . . . . . . . . . . . . . 10
6 Filling the system with auto filling link . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6.1 For zero hour filling with auto filling link . . . . . . . . . . . . . . . . . . . . 11
6.2 For daily usage filling with auto filling link . . . . . . . . . . . . . . . . . . 12

3
Symbols & safety precautions
6720884379 (2018/03)
1 Symbols & safety precautions
1.1 Explanation of symbols
1.2 Safety precautions
If you smell gas!
• Extinguish any naked flames
• Do not smoke or strike matches
• Do not turn electrical switches on or off
• Open doors and windows
• Keep people away from the affected area
• Turn off the gas control valve at the meter
• Call Gas Emergency Service
Boiler Operation:
This boiler must only be operated by a responsible adult who has been instructed in,
understands and is aware of the boiler's operating conditions and effects.
Please read these instructions carefully
These instructions are applicable to Bosch Group boilers only.
After installation please leave this manual with the user.
Symbol Meaning
1. a numbered step in an action sequence
▶ a step in an action sequence
a reference number to identify or refer to a part or item
• a list entry
– a list entry (second level)
1

4
Product information
6720884379 (2018/03)
2 Product information
2.1 Supplied parts
Check that the following parts are contained within the pack:
Manual Filling Link Assembly 8 718 689 275 (including filter 8 718 689 347)
4 x Socket Head Cap Screw M4 x 6mm 2 910 141 116
4 x M4 Lock Washer 2 916 699 130
Fig. 1 Filling link kit
[1] Installation and operation manual
[2] Manual filling link assembly (including filter)
[3] Fitting screws and washers
[4] Automatic filling link assembly (including filter)
0010019842-001
1
3
2
4
or

5
General description
6720884379 (2018/03)
3 General description
The automatic and the manual filling link are Type CA, non-verifiable disconnectors
according to EN 14367-2005.
The filling links have a backflow prevention device and can be left permanently
connected to the heating system up to category 31) heating water according to
EN 1717-2000.
Fig. 2 General description
[1] Central heating return connection
[2] Domestic cold water connection
[3] Filter
[4] Filling lever
[5] Stop tabs
1) The border between category 3 and category 4 is in principle LD 50 = 200 mg/kg
body weight in reference to the EU directive 93/21 EEC dated April 27th, 1993.
12
3
4
5
5
0010019848-001

6
General description
6720884379 (2018/03)
Fig. 3 General description
[1] Central heating return connection
[2] Domestic cold water connection
[3] Filter
[4] Manual filling interface
[5] Stop tabs
[6] Motor
[7] Cable connection interface
In case of inhibitor/additive/anti-freeze usage, please check the
water classification according to EN 1717-2000. Make sure that
the backflow preventer is suitable for water class. AFV/MFV
cannot be used with heating water higher than category 3.
0010018534-001
455
21
3
6
7

7
Fitting and servicing the filling link
6720884379 (2018/03)
4 Fitting and servicing the filling link
4.1 Fitting and servicing the manual filling link
The manifold shown has hexagonal connection, some manifolds have octagonal
connections, the fitting method is identical.
▶ Close the isolating valves on the DHW inlet and CH return connections.
▶ Unscrew and remove the blanking plugs from the DHW inlet and CH return
connections.
▶ Ensure that the filter is positioned inside the inlet of the filling link.
▶ Assemble the filling link onto the DHW inlet and CH return connections.
▶ Ensurethat thefilling linkis pushedin fullyup tothe stoptabs onboth sidesof the
filling link.
▶ Fit two screws and lock washers in each of the isolating valves.
▶ Open the isolating valves on the DHW inlet and CH return connections.
There may be mains and system water pressure present behind
the blanking plugs, ensure that the isolating valves are closed.

8
Fitting and servicing the filling link
6720884379 (2018/03)
Fig. 4 Fitting
[1] Blanking caps
[2] Securing screws
[3] Filling link
4.2 Fitting and servicing the automatic filling link
▶ Close the isolating valves on the DHW inlet and CH return connections.
▶ Unscrew and remove the blanking plugs from the DHW inlet and CH return
connections.
▶ Ensure that the filter is positioned inside the inlet of the filling link.
▶ Assemble the filling link onto the DHW inlet and CH return connections.
▶ Ensurethat thefilling linkis pushedin fullyup tothe stoptabs onboth sidesof the
filling link.
▶ Fit two screws and lock washers in each of the isolating valves.
▶ Open the isolating valves on the DHW inlet and CH return connections.
▶ Fit cable to auto filling link
▶ Fit cable to control as shown in appliance installation manual.
11
2
2
2
2
3
0010019847-001

9
Fitting and servicing the filling link
6720884379 (2018/03)
Fig. 5 Fitting
[1] Filling Link
[2] Cable
[3] Connection to control box
[4] Blanking caps
[5] Securing screws
WARNING: Hot surface: Filling Link motor. Possible skin burns.
▶ Do not touch.
▶ Wear protective equipment.
0010018536-001
44
5
5
5
5
1
2 3

10
Filling the system with manual filling link
6720884379 (2018/03)
5 Filling the system with manual filling link
▶ If the needle on the appliance pressure gauge reads less than 1 bar or low
pressure shown on HMI, re-charge the system.
▶ Pull the blue lever down to start the filling process.
▶ Monitor the pressure gauge or HMI.
▶ When the needle reaches between 1 to 1.5 bar on the gauge or HMI indicates that
the pressure is ok, release the blue lever to stop the filling process.
Fig. 6 Filling the system (manual filling link)
Min
1 bar
1.5 bar
Max
1.
2.
3.
4.
Fault - 1017
Pressure: 0.6 bar
Water pressure
too low
Pressure OK: 1.6 bar
Water pres. Ok
Finish topping up
Fault - 333
Pressure: 0.2 bar
Boiler temporarily
shut down due to
water pressure too low
0010019844-001

11
Filling the system with auto filling link
6720884379 (2018/03)
6 Filling the system with auto filling link
6.1 For zero hour filling with auto filling link
▶ For first installation of appliance filling link of auto filling link should be used.
▶ Turn filling link screw via screwdriver clockwise 90 degree gently to open and
pressurize your system.
▶ Check the pressure gauge during filling operation.
▶ Close filling link via screwdriver gently when the desired system pressure is
reached.
Fig. 7 Filling the system (filling link)
67206800521-06.3Wo
Min
1 bar
1.5 bar
Max
1. 2.
3.
4. 5.
90°
90°

12
Filling the system with auto filling link
6720884379 (2018/03)
6.2 For daily usage filling with auto filling link
• The automatic filling link does not require any operation for filling the system. It
automatically keeps the system pressure at desired pressure.
• Additionally, the automatic filling link is capable to diagnose if sanitary water
pressure is low or there is a leakage in the heating system. For error codes and
functional information, please check your boiler operation manual.
A few drops of water may leak out of backflow preventer drain due
to pressure fluctuations in the heating system and sanitary water
circuit. This is for safety. In case of continuous leakage please
contact with your service.

13
Inhalt
6720884379 (2018/03)
Inhalt
1 Symbole und Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.1 Symbolerklärungen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.2 Sicherheitshinweise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 Produktbeschreibung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Lieferumfang . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 Allgemeines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4 Montage und Wartung des Systemtrenners . . . . . . . . . . . . . . . . . . . . . . 18
4.1 Montage und Wartung des manuellen Systemtrenners . . . . . . . 18
4.2 Montage und Wartung des automatischen Systemtrenners . . . . 19
5 Anlagenbefüllung mit manuellem Systemtrenner . . . . . . . . . . . . . . . . . 21
6 Anlagenbefüllung mit automatischem Systemtrenner . . . . . . . . . . . . . 22
6.1 Erstbefüllung mit automatischem Systemtrenner . . . . . . . . . . . . 22
6.2 Laufendes Nachfüllen mit automatischem Systemtrenner . . . . . 23

14
Symbole und Sicherheitshinweise
6720884379 (2018/03)
1 Symbole und Sicherheitshinweise
1.1 Symbolerklärungen
1.2 Sicherheitshinweise
Verhalten bei Gasgeruch:
• Offene Flammen löschen.
• Nicht rauchen. Keine Streichhölzer anzünden.
• Keine elektrischen Schalter ein- oder ausschalten.
• Fenster und Türen öffnen.
• Menschen vom Gefährdungsbereich fernhalten.
• Regelventil am Gaszähler schließen.
• Gasnotdienst anrufen.
Kesselbetrieb:
Der Kessel darf nur von zuständigen Erwachsenen betrieben werden, die in die
Betriebsbedingungen und Wirkung des Kessels eingewiesen wurden, diese verste-
hen und mit ihnen vertraut sind.
Anleitung sorgfältig lesen
Diese Anleitung gilt nur für Kessel der Bosch-Gruppe.
Anleitung nach der Installation dem Betreiber übergeben.
Symbol Bedeutung
1. Nummerierter Schritt einer Handlungsfolge
▶ Schritt einer Handlungsfolge
Referenznummer, die ein Teil oder eine Position kennzeichnet
bzw. darauf verweist
• Listeneintrag
– Listeneintrag (zweite Ebene)
1

15
Produktbeschreibung
6720884379 (2018/03)
2 Produktbeschreibung
2.1 Lieferumfang
Sicherstellen, dass die Verpackung die folgenden Teile enthält:
Manueller Systemtrenner8 718 689 275 (einschließlich Filter 8 718 689 347)
4 x Inbusschraube M4 x 6 mm 2 910 141 116
4 x M4 Sicherungsscheibe 2 916 699 130
Bild 1 Lieferumfang Systemtrenner
[1] Installations- und Bedienungsanleitung
[2] Manueller Systemtrenner (einschließlich Filter)
[3] Montageschrauben und Unterlegscheiben
[4] Automatischer Systemtrenner (einschließlich Filter)
0010019842-001
1
3
2
4
oder

16
Allgemeines
6720884379 (2018/03)
3 Allgemeines
Der automatische und der manuelle Systemtrenner sind Armaturen vom Typ CA mit
nicht kontrollierbarer Trennung nach EN 14367-2005.
Die Systemtrenner verfügen über einen integrierten Rückflussverhinderer und
können bis zur Heizwasserkategorie 31) gemäß EN 1717-2000 dauerhaft mit der
Heizungsanlage verbunden verbleiben.
Bild 2 Allgemeines
[1] Rücklaufanschluss der Zentralheizung
[2] Trinkwasseranschluss (kalt)
[3] Filter
[4] Befüllhebel
[5] Anschlagnocken
1) Die Grenze zwischen Kategorie 3 und Kategorie 4 liegt im Prinzip bei LD 50 =
200 mg je kg Körpergewicht nach EU-Richtlinie 93/21 EEC vom 27. April 1993.
12
3
4
5
5
0010019848-001

17
Allgemeines
6720884379 (2018/03)
Bild 3 Allgemeines
[1] Rücklaufanschluss der Zentralheizung
[2] Trinkwasseranschluss (kalt)
[3] Filter
[4] Schnittstelle für manuelle Befüllung
[5] Anschlagnocken
[6] Motor
[7] Kabelanschlussschnittstelle
Bei Verwendung von Inhibitoren, Zusatzmitteln oder Frostschutz-
mittel siehe Wasserklassifizierung nach EN 1717-2000. Sicher-
stellen, dass der Rückflussverhinderer für die jeweilige
Wasserklasse geeignet ist. Der AFV/MFV ist zur Verwendung für
Heizwassereiner höheren KategoriealsKategorie 3nichtgeeignet.
0010018534-001
455
21
3
6
7

18
Montage und Wartung des Systemtrenners
6720884379 (2018/03)
4 Montage und Wartung des Systemtrenners
4.1 Montage und Wartung des manuellen Systemtrenners
Dasabgebildete Verteilerstück hat einen Sechskantanschluss.Einige Verteiler verfü-
gen über Achtkantanschlüsse. Die Vorgehensweise bei der Montage ist identisch.
▶ Absperrhähne am WW-Einlass- und HW-Rücklaufanschluss schließen.
▶ Verschlusskappen von WW-Einlass- und HW-Rücklaufanschluss aufschrauben
und abnehmen.
▶ Sicherstellen, dass der Filter im Einlass des Systemtrenners sitzt.
▶ Systemtrenner am WW-Einlass- und HW-Rücklaufanschluss montieren.
▶ Sicherstellen, dass der Systemtrenner komplett bis zu den Anschlagnocken auf
beiden Seiten des Systemtrenners eingeschoben wurde.
▶ Jeden Absperrhahn mit zwei Schrauben und Sicherungsscheiben festschrauben.
▶ Absperrhähne am WW-Einlass- und HW-Rücklaufanschluss öffnen.
Gegebenenfalls liegt hinter den Verschlusskappen der Netz- oder
der Anlagenleitung Wasserdruck an. Sicherstellen, dass die Ab-
sperrhähne geschlossen sind.

19
Montage und Wartung des Systemtrenners
6720884379 (2018/03)
Bild 4 Montage
[1] Verschlusskappen
[2] Sicherungsschrauben
[3] Systemtrenner
4.2 Montage und Wartung des automatischen Systemtrenners
▶ Absperrhähne am WW-Einlass- und HW-Rücklaufanschluss schließen.
▶ Verschlusskappen von WW-Einlass- und HW-Rücklaufanschluss aufschrauben
und abnehmen.
▶ Sicherstellen, dass der Filter im Einlass des Systemtrenners sitzt.
▶ Systemtrenner am WW-Einlass- und HW-Rücklaufanschluss montieren.
▶ Sicherstellen, dass der Systemtrenner komplett bis zu den Anschlagnocken auf
beiden Seiten des Systemtrenners eingeschoben wurde.
▶ Jeden Absperrhahn mit zwei Schrauben und Sicherungsscheiben festschrauben.
▶ Absperrhähne am WW-Einlass- und HW-Rücklaufanschluss öffnen.
▶ Kabel an automatischen Systemtrenner anschließen.
▶ Kabel an Steuerung anschließen, siehe Installationsanleitung des Geräts.
11
2
2
2
2
3
0010019847-001

20
Montage und Wartung des Systemtrenners
6720884379 (2018/03)
Bild 5 Montage
[1] Systemtrenner
[2] Kabel
[3] Anschluss an Steuergerät
[4] Verschlusskappen
[5] Sicherungsschrauben
WARNUNG: Der Motor des Systemtrenners wird heiß.
Verbrennungsgefahr.
▶ Nicht berühren.
▶ Schutzausrüstung tragen.
0010018536-001
44
5
5
5
5
1
2 3
Table of contents
Languages:
Popular Plumbing Product manuals by other brands

Helvex
Helvex Europeo EP-2001 installation guide

Grohe
Grohe Ladylux Plus 33 737 quick start guide

Hans Grohe
Hans Grohe AXOR 26434180 Assembly instructions

Elkay
Elkay ESRC8 1F Installation, care & use manual

American Standard
American Standard COLONY SOFT 2175.5 installation instructions

Heritage Bathrooms
Heritage Bathrooms PGRW01L Fitting Instructions & Contents List

Spectrum
Spectrum Pfister Marielle LG89-XMB Quick installation guide

Gessi
Gessi Oxygene Hi-Tech Pre-installation information

Axor
Axor Carlton 97212000 Service

Laufen
Laufen LIS CW2 Assembly and installation

Hans Grohe
Hans Grohe AXOR Citterio Select 39860 Series Instructions for use/assembly instructions

SFA
SFA SANICUBIC 1 Installation and maintenance instructions