Bosch PVA-CSK PAVIRO User manual

Communications Systems | PVA-CSK PAVIRO Call Station Kit
PVA-CSK PAVIRO Call Station Kit
Connectors for 15 free programmable function
keysConnectors for 3 alarm buttons or key switches
Connectors for microphone (integrated pre-
amplifier with compressor/limiter)
Connector for loudspeaker
Extensive monitoring functions
The PVA-CSK call station kit is a call station printed circuit
board (PCB) for the PAVIRO system. The circuit board
allows an application-specific call station to be installed,
such as a fire department call station.
The call station kit is based on the call station, but has
been optimized so that it is easy to adapt to different
application areas. In addition to the stem microphone
familiar from the PVA-15CST , a dynamic EMERGENCY
microphone such as the LBB9081 can also be connected.
The call station kit equipped with an illuminated LC display
(122 x 32 pixels). The call station has the following
features:
•Possible to connect microphone with pre-amplifier and
compressor/limiting switch
•Possible to connect five pre-programmed menu/
function buttons
•Possible to connect up to 15 function and selection
buttons, programmable button assignment
•Possible to connect up to three alarm buttons or key
switches
•Possible to connect an external microphone or audio
source
•Possible to connect a loudspeaker
•High-resolution LC display
•Comprehensive parameter settings menu on the
actual call station
•Microphone and line monitoring
•Error message via LED and buzzer, and error text in
the LC display
•Processor control of all functions
•Monitoring of the processor system via watchdog
circuit
•Non-volatile FLASH memory for configuration data The
call station is processor-controlled, and equipped with
extensive monitoring functions. Line monitoring for the
CAN bus and for audio transmission allows line
interruptions and short-circuits to be detected and
indicated to the user. The microphone, PTT button, alarm
button and key switch monitoring allows line interruptions
and short-circuits to be detected and reported.
The call stations for the PAVIRO system can be
configured quickly and easily using IRIS-Net. A graphical
and dialog-based user interface allows the user to define
all button functions, priorities, options, and other
properties.
Parts included
Number Component
1 PVA-CSK printed circuit board
1 PVA-CSK display

2 | PVA-CSK PAVIRO Call Station Kit
Number Component
1 Connection cable for display (50 cm)
10 Euroblock connector 10-pole (Phoenix, MC
1,5/10-STF-3,81, 1803659, F.01U.241.148)
1 Euroblock connector 2-pole (Dinkle,
EC381V-02P, F. 01U.066.918)
1 Operation manual
1 Important safety instructions
* PMX-CSK Scope of Delivery
Technical specifications
Buttons (through screw-terminal
5 pre-programmed
connectors)
15 programmable zone/function
buttons
3 supervised programmable
optional emergency buttons
2 connections for each button;
23 buttons share 6 common
VCCs (3V3 - DC)
Each button has short circuit
protection
LEDs connected to buttons
This kit supports open drain
(through screw-terminal
outputs with max. 5 mA per
connectors)
output. Using the internal supply,
a maximum of 100 mA can be
sourced for all outputs.
The kit also provides an external
power supply for lighting LEDs of
external normal buttons.
2 connections (VCC & open
collector) are available for each
LED connected to a button. In
total, 38 LEDs share 10 common
MIX_PWR_LED. These LEDs are
supplied with 5 V DC using the
internal power supply. The
connected LEDs are supplied with
24 V DC using the external power
supply.
Each LED circuit has short-circuit
protection.
Power LED (through screw-
Driven by MIX_PWR_LED (5 V DC
terminal connectors)
or 24 V DC)
2 connections (VCC & open
collector)
Fault LED (through screw-
Driven by MIX_PWR_LED (5 V DC
terminal connectors)
or 24 V DC)
2 connections (VCC & open
collector)
Alarm LED (through screw-
Driven by MIX_PWR_LED (5 V DC
terminal connectors)
or 24 V DC)
2 connections (VCC & open
collector)
Included LCD display kit
A flat ribbon cable connects the
display to the call station kit
mainboard. The ribbon cable
length is +/- 300 mm
Others (through screw-terminal
1 audio source (line in)
connectors)
1 supervised microphone input
(LBB9081) capsule and PTT
button connection (input & VCC)
with short-circuit protection. 1
loudspeaker connection, 1
additional +24 V DC power
supply
External connectors
1 call station bus connector
(control data + audio + power
supply, RJ-45)
1 EXT connector (RJ-12, e.g. for
call station extension)
Main power supply
•
Nominal voltage
24 V DC (-10%/+30%)
•
Maximum voltage range
15–58 V DC
Nominal current consumption for
< 100 mA
main power supply
Maximum supply current
• External power supply for
< 80 mA/24 V
lighting, without
< 110 mA/18 V
extensions
• Internal power supply for
< 150 mA/24 V
lighting, without
< 200 mA/18 V
extensions
CAN interface
10, 20, or 62.5 kbit/s
Maximum mic input level
-21 dBu
Maximum line input level
+4 dBu
NF output
Balanced
•
Nominal level
+6 dBu
•
Maximum level
+12 dBu
Frequency response
200–16,000 Hz, +0/-3 dB
Signal-to-noise ratio (Mic and
≥ 60 dB
Line input, NF output)
Buttons
•
Nominal voltage
3.3 V DC
•
Max current
100 mA
PTT input switch
•
Nominal voltage
3.3 V DC
•
Max current
100 mA
LEDs

3 | PVA-CSK PAVIRO Call Station Kit
•
Nominal drive current
5 mA for each LED
•
Maximum drive current
20 mA for each LED
•
Nominal drive voltage
• 5 V by internal power
supply for 5-V point
lighting LEDs
• 24 V by external power
supply for 24-V ring
lighting LEDs
Additional power supply for
industrial buttons backlight
•
Nominal voltage
24 V DC (-10/+30%)
•
Nominal current
< 300 mA
consumption
•
Maximum supply current
< 500 mA at 24 V
External speaker
•
Nominal resistance
8 Ω
•
Power rating
1.5 W
•
Maximum power
2 W
•
Nominal operating voltage
3.5 V
Normal microphone (LBB9081
reference)
•
Sensitivity
3.1 mV/Pa ±4 dB
•
Frequency response
280–14000 Hz
•
Rated output impedance
500 Ω
•
Polar pattern
Omnidirectional
•
Switch
On/off with remote control
contact

4 | PVA-CSK PAVIRO Call Station Kit
Circuit diagram

5 | PVA-CSK PAVIRO Call Station Kit
5.00mm
5.00mm
220.00mm
0
0
m
m
Installation Holes * ø4mm(Diameter) X 4
5
.
1.60mm
5.00mm
Dimensions Mainboard
150.00mm
5.00mm
5.00mm
5.00mm
5.00mm

6 | PVA-CSK PAVIRO Call Station Kit
1.6mm
5.0mm
5.0mm
85.0mm
Installation Holes * ø4mm(Diameter) X 4
5.0mm
5.0mm
5.0mm
5.0mm
Dimensions LCD board
Ordering information
PVA-CSK PAVIRO Call Station Kit
Call station kit
Order number PVA-CSK