1.0 Description
The DS9432/B is an Eight Input Remote Module that provides a
means of addressing up to eight input loops of conventional
contacts to the multiplex bus of the DS9400 Series Fire Alarm
Control/Communicator.
2.0 Specifications
• Control Panel Requirements: The DS9432/B is designed to
work with the Detection Systems DS9400 Series Fire Alarm
Control Communicator. Version 2.0 software or higher is required
in the DS9400. The DS9400 can support up to 30 DS9432/B
modules. One DS9431 Multiplex Expansion Module is required
in the system to use the DS9432/B Eight Input Remote Module.
•Current Draw (from option bus power): 8 mA Standby and Alarm
•Current Draw (from multiplex bus loop): 10 mA Standby and
Alarm
•Total Current Draw for Battery Standby Calculation and Alarm:
18 mA Standby and Alarm
• Minimum Bus Voltage For Operation: 8 VDC peak
•Wiring: Refer to the DS9400M Reference Guide (P/N: 44578) for
the panel’s multiplex expansion module for multiplex wiring
requirements. The length of the wire connected to the loop inputs
on the DS9432/B must be less than 250 ft. (76 m) per loop.
• The recommended minimum wiring to the control is standard #18
(1.2 mm). Do not use shielded or twisted pair cable.
For UL Listed fire applications, minimum #18 AWG (1.2
mm) wire is required.
3.0 Installation
P3 of the DS9432 is for European applications only. Do
not put a jumper here.
P2 of the DS9432 allows the tamper switch to be bypassed with a
jumper when testing or servicing.
Remove jumper P2 when testing or servicing has been
completed.
3.1 DS9432 Installation
Use the mounting holes (upper left and lower right corners) to
mount. It can be mounted inside or outside of the control enclosure.
Route wiring as necessary from the DS9431 in the control enclosure
and from the remote devices to the DS9432.
Connect wiring as shown in Figure 2.
Be sure all wiring is unpowered before routing.
If the wiring is to enter through the rear of the enclosure, open the
DS9432's rear wire entrance. If the wiring is to run along the surface
of the enclosure, open the DS9432's surface wire entrance. See Figure
2.
3.2 DS9432B Installation
The DS9432B will come partially preassembled with the circuit board
attached to the mounting skirt.
Mounting Holes
Attach Mounting Skirt Here
Figure 1: DS9432B
Select a mounting location for the DS9432B.
Using the enclosure as a template, mark the mounting holes on the
mounting surface and make an opening for the unit’s wiring.
Next, attach the mounting skirt (with the circuit board attached) to
the enclosure (hardware provided). Then complete all wiring (see
Section 4.0).
Once installation and wiring is completed, attach the enclosure
cover and secure with the screws (provided).
Page 2 F01U089253-01 © 2008 Bosch Security Systems, Inc. DS9432/DS9432B Installation Instructions
4.0 Wiring
+–+–12345678
NO
NC NC
NO NO
NC NC
NO NO
NC NC
NO NO
NC NC
NO
POWER BUS
To control panel 12 VDC power terminals:
DS9400M, terminals RA and BA, Fig. 3
To DS9431 MUX BUS Terminals
(see Figure 3)
Input Loops
To separate powered detectors (other than smoke detectors)
+
-
+
-
When used with a DS9431 , power is
connected to the option bus power terminals
(RA or RB (+), BA or BB (-)). Connection to
24 VDC sources will damage the DS9432.
For UL Listed fire installations, Normally
Open (N/O) contacts must be used.
*Fire EOL resistor: 47 k ohm; DS P/N: 28010
EOL* EOL* EOL* EOL* EOL* EOL* EOL* EOL*
Figure 2: Wiring the DS9432/B with Separate Powered Detectors
21 3
4 5 6
7 8 9
#
Cmnd
0
Prog
*
Clear
Disable
Drill
Test
History
Reset
Silence
Trouble
Silenced
Power
Alarm
+– 23 45 67 8
POWER
12V Power (-)
12V Power (+)
EOL
Resistor
P/N: 28010
Smoke
Detector
Smoke
Detector
EOL
Relay
Bus (+)
Power + may be connected to RA or RB
on the FACP Option Bus terminal strip.
Power - may be connected to BA or BB on
the FACP Option Bus.
Bus + and Bus - are connected to
MUX A terminals for addresses 9 -
128. MUX B terminals are for
addresses 129 - 255.
Example:
DS250 in a MB4W base
Example: EOL200
DS9400 FACP
DS9431Multiplex Expansion Module
I/O Module for the
DS9431 Multiplex
Expansion Module
DS7432 Eight Input Remote Module
1-
L+
2-
3-
L+
4-
AUX-
AUX+
24V Smoke Power (-)
24V Smoke Power (+)
+ –
BUS 1
SMK-
SMK+
NFPA 72 does not allow redundant/duplicate
ground paths, do not connect wiring to the
BUS (-) terminal on this module for fire
applications. Only the BUS (+) needs to be
connected.
Figure 3: 4-Wire Smoke Detector Wiring for the DS9432/B and DS9400M FACP
For UL Listed fire installations, Normally Open (N/O) contacts must be used.
DS9432/DS9432B Installation Instructions © 2008 Bosch Security Systems, Inc. F01U089253-01 Page 3
5.0 Programming
The DS9432/B occupies eight multiplex point addresses
when connected to the control panel.
5.1 System Programming
Refer to the System Programming section in the DS9400M
Reference Guide (P/N: 44578) for zone programming information.
5.2 DIP Switch Settings
The DIP switches select which points will be activated by the loop
inputs. Set the DIP switches as shown in Table 1.
• No two DS9432/Bs should be set the same.
• The input loops of the DS9432/B correspond to the points of the
control as shown in Table 2.
ON
OFF
Figure 4: DIP Switch Orientation
+–+–12345678
POWER BUS
Locking tab
Surface Wire Entrance
Rear Wire Entrance
Ta m p e r S w i t c h
DIP switch
P2
P3
Figure 5: DS9432 Front View Without Cover
241-248
233-240
225-232
217-224
209-216
201-208
193-200
185-192
177-184
169-176
161-168
153-160
145-152
137-144
129-136
121-128
113-120
105-112
97-104
89-96
81-88
73-80
65-72
57-64
49-56
41-48
33-40
25-32
17-24
9-16
Points
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Open
O
pen
Open
Open
Open
Open
Open
Open
Open
Open
Open
Open
1
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Open
Open
Open
2
Closed
Closed
Closed
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Open
Open
Open
Open
Closed
Closed
Closed
Closed
Open
Open
Open
3
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
Open
Closed
Closed
Open
4
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
Open
Closed
5
DIP Switches
Table 1: DIP Switch Settings
Points 241-248
Points 233-240
Points 225-232
Points 217-224
Points 209-216
Points 201-208
Points 193-200
Points 185-192
Points 177-184
Points 169-176
Points 161-168
Points 153-160
Points 145-152
Points 137-144
Points 129-136
Points 121-128
Points 113-120
Points 105-112
Points 97-104
Points 89-96
Points 81-88
Points 73-80
Points 65-72
Points 57-64
Points 49-56
Points 41-48
Points 33-40
Points 25-32
Points 17-24
Points 9-16
Input Loop
241
233
225
217
209
201
193
185
177
169
161
153
145
137
129
121
113
105
97
89
81
73
65
57
49
41
33
25
17
9
1
242
234
226
218
210
202
194
186
178
170
162
154
146
138
130
122
114
106
98
90
82
74
66
58
50
42
34
26
18
10
2
243
235
227
219
211
203
195
187
179
171
163
155
147
139
131
123
115
107
99
91
83
75
67
59
51
43
35
27
19
11
3
244
236
228
220
212
204
196
188
180
172
164
156
148
140
132
124
116
108
100
92
84
76
68
60
52
44
36
28
20
12
4
245
237
229
221
213
205
197
189
181
173
165
157
149
141
133
125
117
109
101
93
85
77
69
61
53
45
37
29
21
13
5
246
238
230
222
214
206
198
190
182
174
166
158
150
142
134
126
118
110
102
94
86
78
70
62
54
46
38
30
22
14
6
247
239
231
223
215
207
199
191
183
175
167
159
151
143
135
127
119
111
103
95
87
79
71
63
55
47
39
31
23
15
7
248
240
232
224
216
208
200
192
184
176
168
160
152
144
136
128
120
112
104
96
88
80
72
64
56
48
40
32
24
16
8
Point Number
Table 2: Loop/Point Number Relationship
© 2008 Bosch Security Systems, Inc.,
130 Perinton Parkway, Fairport, New York, USA 14450-9199
(585) 223-4060
11/08
DS9432/B Installation Instructions
P/N: F01U089253-01 Page 4

This manual suits for next models

1

Other Bosch I/O System manuals

Bosch DS7432 User manual

Bosch

Bosch DS7432 User manual

Bosch PC600 User manual

Bosch

Bosch PC600 User manual

Bosch B308 User manual

Bosch

Bosch B308 User manual

Bosch Rexroth Inline Series Instruction Manual

Bosch

Bosch Rexroth Inline Series Instruction Manual

Bosch Rexroth IndraControl S67 Series User guide

Bosch

Bosch Rexroth IndraControl S67 Series User guide

Bosch B208 User manual

Bosch

Bosch B208 User manual

Bosch Rexroth IndraControl S20 User guide

Bosch

Bosch Rexroth IndraControl S20 User guide

Bosch FLM-420-I2-E User manual

Bosch

Bosch FLM-420-I2-E User manual

Bosch B208 User manual

Bosch

Bosch B208 User manual

Bosch D7044 User manual

Bosch

Bosch D7044 User manual

Bosch FLM-420-O1I1-E User manual

Bosch

Bosch FLM-420-O1I1-E User manual

Bosch Rexroth IndraControl S67 Series User manual

Bosch

Bosch Rexroth IndraControl S67 Series User manual

Bosch FLM-420-I2-D User manual

Bosch

Bosch FLM-420-I2-D User manual

Bosch B308 User manual

Bosch

Bosch B308 User manual

Bosch FLM-420-I2-W User manual

Bosch

Bosch FLM-420-I2-W User manual

Bosch Rexroth IndraControl S20 User manual

Bosch

Bosch Rexroth IndraControl S20 User manual

Bosch segmil D7044M User manual

Bosch

Bosch segmil D7044M User manual

Popular I/O System manuals by other brands

Megmeet MV800 user manual

Megmeet

Megmeet MV800 user manual

Siemens APACS+ Installation and service instruction

Siemens

Siemens APACS+ Installation and service instruction

TOPSCCC EX-94421 user manual

TOPSCCC

TOPSCCC EX-94421 user manual

Seneca R-P Series user manual

Seneca

Seneca R-P Series user manual

EES USM series manual

EES

EES USM series manual

turck BL20 Instructions for use

turck

turck BL20 Instructions for use

Siemens SIMATIC ET 200iSP installation manual

Siemens

Siemens SIMATIC ET 200iSP installation manual

ICP DAS USA PISO-P32C32U-5V quick start

ICP DAS USA

ICP DAS USA PISO-P32C32U-5V quick start

Unitronics IO-ATC8 quick start guide

Unitronics

Unitronics IO-ATC8 quick start guide

Euresys Coaxlink Programmer's guide

Euresys

Euresys Coaxlink Programmer's guide

KonNad C2000-A2-SMD4440-AE1 user manual

KonNad

KonNad C2000-A2-SMD4440-AE1 user manual

Festo CPX-AP-I-4DI4DO-M12-5P Instructions and Operating

Festo

Festo CPX-AP-I-4DI4DO-M12-5P Instructions and Operating

Beckhoff EPI3 Series Documentation

Beckhoff

Beckhoff EPI3 Series Documentation

Nice M01 Series Instructions and warnings for installation and use

Nice

Nice M01 Series Instructions and warnings for installation and use

Acromag IP320 Series user manual

Acromag

Acromag IP320 Series user manual

Sensitron STG/IN8-S instruction manual

Sensitron

Sensitron STG/IN8-S instruction manual

ABB Symphony Harmony Series instructions

ABB

ABB Symphony Harmony Series instructions

Measurement Computing PCI-DIO96 user guide

Measurement Computing

Measurement Computing PCI-DIO96 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.