21242 rev. 01
E64000LC SERIES
HB0072
INSTALLATION INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
Broan-NuTone Canada ULC, Mississauga, Ontario www.broan.ca 877-896-1119
REGISTER YOUR PRODUCT ONLINE AT: www.broan.ca
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 & 14.
! !

2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented outdoors.
7. Do not use this unit with any additional solid-state speed
control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCETHE RISK OF A RANGETOP GREASE FIRE:
a) Never leave surface units unattended at high settings.Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will automatically
shut off the motor if it becomes overheated. The motor will
restart when it will be cooled down. If the motor continues to
shut off and restart, have the hood serviced.
5. For best capture of cooking impurities, the bottom of the hood
should be at a minimum of 24” and at a maximum of 30” above
the cooking surface. For a gas range, the bottom of the hood
MUST NOT BE LESS than 30” above cooktop.
6. Two installers are recommended because of the large size and
weight of this hood.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically.To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this hood, you
should make sure enough air is entering the house to replace
exhausted air. Use an appropriate make-up air device or open
a window close to or in the kitchen.
10. To reduce the risk of fire and electric shock, the Broan Elite
E64E Series hood must be installed with one Broan exterior
blower model 331H, 332H, 335 or 336; or one Broan in-line
blower model HLB3, HLB6, HLB9 ou HLB11. Other blowers
cannot be substituted. (Exterior or in-line blowers sold
separately.)
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCETHE RISK OF INJURYTO PERSONS INTHE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner.BE CAREFULTO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
B. The fire is small and contained in the area where it started.
C. The fire department has been called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
WARNING
!

3
HL0174
-E64000LC SERIES RANGE HOOD SYSTEM -
INTERNAL BLOWERS
MODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL 421
(10" ROUND VERTICAL
IN-LINE DAMPER)
MODEL 441
(10" ROUND
WALL CAP)
MODEL 418
(10" ROUND ADJUSTABLE ELBOW)
MODEL 410
(10" ROUND DUCT — 2 FT. SECTIONS)
MODEL 427
(4½" X18½"
TO 10" ROUND,
6" HIGH - LATERAL)
MODEL 423
(4½" X18½"
TO 10" ROUND -
VERTICAL)
MODEL 424
(4½" X18½"
TO 10" ROUND -
HORIZ. FRONT/REAR)
MODEL 454
(4½" X18½"
TO 10" ROUND -
HORIZ. /RIGHT)
MODEL 453
(4½" X18½"
TO 10" ROUND -
HORIZ. /LEFT)
ADAPTER 4½" X18½"
(SUPPLIED WITH
DOUBLE BLOWER HOOD)
DOUBLE BLOWER (1100 CFM)
E64000LC SERIES HOOD
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES.
OPTIONAL.)
SINGLE BLOWER (600 CFM)
ADAPTER/DAMPER
3¼" X10"
(SUPPLIED WITH
SINGLE BLOWER HOOD)
STANDARD
DUCT
(3¼" X10")
MODEL 639
(3¼" X10"
WALL CAP)MODEL 413
TRANSITION
(3¼" X10" TO 8")
8" ROUND
STANDARD
DUCT
8" ROUND
ADJUSTABLE ELBOW
MODEL 415
(7" ROUND
ADJUSTABLE ELBOW)
MODEL 407
(7" ROUND
- 2 FT. SECTIONS)
MODEL 412
TRANSITION
(3¼" X10" TO 7")
MODEL 647
(7" ROUND
WALL CAP)MODEL 634
OR 644
(ROOF CAP)
MODEL 643
(8" ROUND
WALL CAP)

4
HL0098
-E64000LC SERIES RANGE HOOD SYSTEM -
IN-LINE AND EXTERIOR BLOWERS
E64000LC SERIES HOOD
MODEL 643
(8" ROUND
WALL CAP)
MODEL 437
(HIGH CAPACITY ROOF CAP)
MODEL 441
(10" ROUND
WALL CAP)
MODEL HLB6 (660 CFM)
IN-LINE BLOWER
(INCLUDES TWO 4½" X18½" TO
10" ROUND TRANSITIONS)
MODEL 418
(10" ROUND
ADJUSTABLE ELBOW)
MODEL 410
(10" ROUND DUCT
- 2FT. SECTIONS)
MODEL HLB9 (800 CFM)
OR HLB11 (1100 CFM)
IN-LINE BLOWER
(INCLUDES TWO 8" X12" TO
10" ROUND TRANSITIONS)
MODEL 331H (600 CFM)
OR 332H (900 CFM)
EXTERIOR BLOWER
MODEL 335 (1200 CFM)
OR 336 (1500 CFM)
EXTERIOR BLOWER
MODEL 421
(10" ROUND VERT.
IN-LINE DAMPER)
RECOMMENDED FOR
USE WITH EXTERIOR
BLOWERS
332KR IN-LINE AND
EXTERIOR BLOWER ROUGH-IN KIT
(SUPPLIED WITH HOOD)
RMP SERIES BACKSPLASH
(STAINLESS STEEL WALL COVERING
WITH WARMING SHELVES. OPTIONAL)
MODEL HLB3 (280 CFM)
IN-LINE BLOWER
(INCLUDES ONE 8" TO 10"
ROUND TRANSITION)

5
Hood
3¼” x 10” duct
or 7” or 8” round duct
Roof cap
Wall
cap
HH0085A
24” minimum above
cooking surface
(30” for gas range)
3¼” x 10” to 7” or
3¼” x 10” to 8” transition
(if using round duct)
1. SELECT BLOWER OPTION
The Broan Elite E64000LC Series range hood includes many configurations: hoods with single or double internal blowers (included with
the hoods), or hoods using external blowers. For hoods using external blowers, the Broan Elite E64000LC Series must be installed with
in-line blower models HLB3, HLB6, HLB9 or HLB11, or exterior blower model 331H, 332H, 335 or 336 only. Other blowers cannot be
substituted. (Blowers sold separately).
Plan where and how the ductwork will be installed.
If installing in-line blower, refer to instructions packed with in-line blower and follow steps 1, 2, 3, 4, 9 and up of this manual.
Install proper-sized ductwork, elbows and roof or wall cap for the type of blower you are installing. If using 7", 8" or 10" round ducts, use a
transition (internal blower(s) only). Use 2" metal foil duct tape to seal duct joints.
We recommend to install the hood at a minimum distance of 24” from an electric range and at 30” from a gas range.
Distances over 30" are at the installer and users discretion.
Hood
10” round duct
Roof cap
Wall
cap
4½” x 18½” to 10”
transition
HH0086A
24” minimum above
cooking surface
(30” for gas range)
HH0087A
Hood
10” round duct
Exterior blower
24” minimum above
cooking surface
(30” for gas range)
In-line blower
10” round duct (except
HLB3, 8” round duct)
HH0092A
24” minimum
above cooking
surface
(30” for gas range)
Roof cap
Wall
cap
Hood
SINGLE INTERNAL BLOWER
TYPICAL DUCTWORK
DOUBLE INTERNAL BLOWERS
TYPICAL DUCTWORK
MODEL 331H, 332H, 335 OR 336
EXTERIOR BLOWER TYPICAL DUCTWORK
MODEL HLB3, HLB6, HLB9 OR HLB11
IN-LINE BLOWER TYPICAL DUCTWORK

6
WARNING
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Make sure that the following items are included:
- Range hood
- Accessories:
• Baffle filters with handles: 30” and 36” hoods come with 3 baffle filters; 42” and 48” hoods come with 4 baffle filters
• 3¼” x 10” adapter/damper (included with internal single blower hood, see page 8 to locate the adapter)
• 4½” x 18½” adapter (included with internal double blower hood, see page 8 to locate the adapter)
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
• Bag of parts including:
1 wire clamp, 9 no. 8 x 1/2”, 2 wire connectors, 8 no. 8-32 x 1/4” mechanical screws, 4 no. 8 x 3/8” screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331H, 332H, 335 or 336
- RMP Series Backsplash (optional)
- Transitions, duct, elbows, dampers, wall or roof cap
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
NOTES: 1. For cabinets with recessed bottom, attach three wood filler strips cut to length (not included), on each side, as shown below.
See illustration and table below for wood filler strips location.
2. For hoods with external or in-line blowers, do not install the transverse wood filler strip.
2. PREPARE THE INSTALLATION
HOOD WIDTHS CENTER OF WOOD
STRIP LOCATION (A)
30” 13³/8”
36” 16³/8”
42” 19³/8”
48” 22³/8”
HD0285A
L
C
AA 10”
!

7
2. PREPARE THE INSTALLATION (CONT’D)
Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen.
See figures below.
NOTE: For all internal blower hoods, the cut-out opening for house wiring can be made in cabinet bottom OR wall, no matter the
discharge chosen (vertical or horizontal).
3. INSTALL BACKSPLASH (OPTIONAL)
Backsplash must be installed before the hood shell because the hood shell covers the backsplash top mounting screws. In order to be able
to install the backsplash, make sure you have at least 18" clearance between bottom of hood and range control panel or cooktop. (See
instructions packed with backsplash.)
L
C
CABINET BOTTOM VIEW
22”
10”10”
INTERNAL DOUBLE BLOWER HOOD
HD0656A
L
C
B
CABINET BOTTOM VIEW
5¼”5¼”
3¾”
A
INTERNAL SINGLE BLOWER HOOD
L
C
INTERNAL SINGLE BLOWER HOOD
2”
B
3¾”
5¼” 5¼” A
L
C
22”
INTERNAL DOUBLE BLOWER HOOD
5½”
10” 10”
7/8”
5½”
3/4”
L
C
CABINET BOTTOM VIEW
578”
HOOD WITH IN-LINE OR EXTERIOR BLOWER
3½”
478”
B
A
Ø 10½”
10¼”
B
A
C
C
2”
2”
B
A2”
2”
2”
2”
2”
9³8”
CABINET CENTER LINE
5/8” 1/4”
3/8”
HOOD WIDTHS DIMENSION C
30" 13"
36" 16"
42" 19"
48" 22"
VERTICAL DISCHARGE
HOOD WIDTHS DIMENSION C
30" 13"
36" 16"
42" 19"
48" 22"
HORIZONTAL DISCHARGE
VERTICAL DISCHARGE ONLY

8
Fold the adapter and insert the male part (grey section shown in inset) into the female part
(white section shown in the inset). Then, fold over each male and female end to finalize
assembling the adapter.
DOUBLE BLOWER HOOD, 48”WIDE
First unplug both blower motors (1) before removing the 3 screws retaining the adapter (2)
to the inner top of the hood.
NOTE: For these specific hoods, the adapter is sent unfold. See at right.
NOTE: For 36” and 42” wide double blower
hoods, the adapter is taped on top of
the filters. Remove adapter and set
aside before removing filters.
A. Remove tape on filters.
Remove filters from hood and set aside.
NOTE: It is recommended to start with the
middle filter(s).
B. Lift out grease drip rail (1) and set aside.
SINGLE BLOWER HOOD
Remove both screws retaining the adapter/damper (1) from inner top of the hood.
4. REMOVE THE FILTERS AND THE GREASE DRIP RAIL
5. REMOVE THE ADAPTER (INTERNAL BLOWER HOODS ONLY)
HD0584 AB
1
HD0259
1
HD0284
HD0585
2
1

9
Using a 5/16" socket, remove all blower mounting
screws from the inner top of the hood. Keep the
screws for further use.
HD0282
RIGHT SIDE
MOUNTING SCREWS
LOCATION
6. CHOSE THE OPENING(S) (INTERNAL BLOWER HOODS ONLY)
Remove the knockout for the chosen opening(s) (horizontal at the back of the hood or vertical on top). See illustrations below.
VERTICAL DISCHARGE
HORIZONTAL DISCHARGE
Punch out the appropriate electrical knockout hole on top (A) or back (B) of the
hood. Install the wire clamp (included in parts bag).
12 3
HR0021
123
HR0024
AB
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY)
All internal blower hoods are factory shipped with the blower(s) mounted for a vertical discharge configuration. For a horizontal discharge
configuration, disassemble the blower(s) from the inner top of the hood and mount it (them) to the back panel of the hood. The procedure
below applies for one or two motors.
Unplug the blower.
HE0085
HD0269
LEFT SIDE MOUNTING
SCREWS LOCATION

10
8. INSTALL THE ADAPTER AND THE TRANSITION (IF NEED BE)
(INTERNAL BLOWER HOOD ONLY)
HJ0013
Using standard 3/8" screws provided, secure
the adapter to the top (or back) of the hood
(2 screws for a 3¼" x 10" adapter/damper and
4 screws for a 4½" x 18½" adapter). Seal the
adapter to the hood using metal foil duct tape.
For round ducting, install an appropriate sized
transition and seal the joints with metal foil
duct tape.
7. HORIZONTAL DISCHARGE INSTALLATION (INTERNAL BLOWER(S) ONLY) (CONT'D)
Slide the blower to disengage its flange from the retaining bracket.
HD0270
Flip the blower and engage its flange in the back wall
retaining bracket.
Using a 5/16" socket and the screws previously
removed, secure the blower to the hood.
Plug the blower in.
NOTE FOR DUAL BLOWER HOOD ONLY: Cut off the plastic tie wrap on left motor cable.
HE0085
HD0271
LEFT SIDE
MOUNTING
SCREW
LOCATION
HD0272
RIGHT SIDE
MOUNTING
SCREW
LOCATION

11
INTERNAL BLOWER: Run power cable to installation location. Remove wiring cover and place the hood in its location. Mark the position
of the screws (smaller part of the key holes [A]) with a pen. Remove the hood and install the four 1/2" double thread screws at marked
positions, leaving a 1/8" gap. You may use up to eight key holes and screws for wider hoods and double blower hoods. Insert the cable
in the hood through the wire clamp and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it into
position. Make sure the adapter (or the transition) enters the ducting. Secure the hood by tightening the screws completely. Install the last
1/2" double thread screws in the remaining holes [B].
Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS: Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN
or bare wire under GREEN ground screw.
Reinstall wiring cover.
IN-LINE OR EXTERIOR BLOWERS: See instructions included with blower.
9. INSTALL THE HOOD (ALL BLOWERS)
10. CONNECT WIRING (ALL BLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
!
CAUTION
The ORANGE wire (A) is for make-up air device connection only. If
there is no make-up air device, never remove the cap on the ORANGE
wire end.
HE0088
A
HD0265
A
B
A
B
B
INTERNAL BLOWER HOOD EXTERIOR OR IN-LINE BLOWER HOOD
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws
(smaller part of the key holes [A]) with a pen. Remove the hood and install the 4 1/2" double thread screws at marked positions, leaving a
1/8" gap. Remove wiring cover on top of the hood, punch-out the electrical knock-out and install the wire clamp. Insert the cable in the hood
through the wire clamp and tighten the wire clamp to secure the cable. Connect wiring (see instructions included with exterior or in-line
blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely. Install the last
1/2" double thread screws in the remaining holes [B].
Refer to instructions included with blower.
Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside
the hood (A) and the 2-prong male connector cord from rough-in plate to the 2-prong plug
inside the hood (B).
11. INSTALL THE BLOWER (EXTERIOR OR IN-LINE BLOWER)
WARNING
!
Do not plug the 2 cords together.
HE0078
BA

12
13. REINSTALL GREASE DRIP RAIL AND BAFFLE FILTERS
HD0586
Reinstall grease drip rail.The illustration at right shows how to reinsert the grease drip
rail into the range hood.
CAUTION
Remove protective plastic film covering filters before installing them.
HD0587
1
2
It is recommended to install side filters first and finish with middle one(s).
1. Insert one end of the filter into the upper channel of the hood.
2. Raise the other end towards the inside of hood and insert in the grease drip rail
of the hood.
12. LED LIGHTING
!
WARNING
Do not touch lamps during or soon after operation. Burns may occur. Cannot be replaced by any other type of light
bulb or LED module.
The lighting of this hood is produced by two LED modules (included).

13
14. USE AND CARE
Baffle Filters
The baffle filters should be cleaned frequently. Use a warm detergent solution. Wash often if your cooking style generates a lot of grease—
like frying food or wok cooking.
Remove baffle filters by pushing them towards the back of the hood and rotating them downward. Baffle filters are dishwasher safe. Allow
filters to dry completely before reinstalling them in the hood.
You may clean all-metal filters in the dishwasher using a non-phosphate detergent. Discoloration of the filter may occur if using phosphate
detergent or as a result of local water conditions—but this will not affect filter performance.This discoloration is not covered by the warranty.
Grease Drip Rail
The grease drip rail should be cleaned frequently. Lift it out from the hood and use a warm detergent solution. As for the baffle filters, wash
more often if your cooking style generates a lot of grease—like frying foods or wok cooking.Allow grease drip rail to dry completely before
reinstalling it in the hood.
Blower(s) Cleaning (Internal)
Remove the filters in order to access the blower(s). Do not immerse in water.
Hood Cleaning
Stainless steel cleaning:
Do:
• Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
• You may also use a specialized household stainless
steel cleaner.
Don’t:
• Use any steel or stainless steel wool or any other scrapers to
remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the
hood. During construction/renovation, cover the hood to make
sure no dust sticks to stainless steel surface.
Avoid when choosing a detergent:
• Any cleaners that contain bleach will attack stainless steel.
• Any products containing chloride, fluoride, iodide, bromide or phosphate will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive and should never be
used close to a range.
15. OPERATION
WARNING
!
The HEAT SENTRY can start the blower during a range top fire or other excessive heat situations even if the hood
is turned off. In this case, it is impossible to turn the blower OFF using control panel buttons. To turn blower OFF:
For exterior or in-line blower hoods, unplug the 2-prong connector cord from inside the hood (C). For internal
blower hoods, set the main power switch (D) (adjoining the electrical box) in OFF position (if it is possible to do
so safely in both cases).
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clear the
air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HEAT SENTRY™
This hood is equipped with a Heat Sentry™ thermostat. This thermostat is a device that will turn on the blower if it senses excessive heat
above the cooking surface.
1) If blower is OFF - it turns blower ON to the last selected speed.
2) If blower is already ON speed will remain the same.
When the temperature level drops to normal, the blower will return to its
original setting.
HD0450
MAIN
POWER SWITCH
D
HE0078
C

14
16. WARRANTY
ONE YEAR LIMITED WARRANTY FOR BROAN ELITE PRODUCTS
Broan-NuTone Canada (Broan-NuTone) warrants to the original consumer purchaser of Broan Elite products that such products will
be free from defects in materials or workmanship for a period of one year from the date of original purchase. LED modules and
LED driver are also covered by this warranty for a period of one (1) year. THERE ARE NO OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS,
FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover
(a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
Warranty service is to be completed by an authorized Service Center designated by Broan-NuTone. Where applicable, in-home service
will be made available only in areas where a contracted service provider offers service. If in-home service is not available, the product
will be repaired or replaced, at Broan-NuTone’s discretion, by the nearest authorized service provider.The unit removal and reinstallation
works are under the customer responsibility, and Broan-NuTone cannot be charged for them.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some provinces do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S
SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE.
Some provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from one province to another.This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at one of the addresses or telephone number stated below, (b) give
the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Broan-NuTone Canada ULC, 1140 Tristar Drive, Mississauga, ON L5T 1H9 www.broan.ca 1-877-896-1119
15. OPERATION (CONT'D)
HC0073 AB
1) LED lighting knob
2) Blower operation indicator
3) ON/OFF blower switch
4) Blower speed control knob
HC0035
1
3
2
4
A) LED lighting knob
B) Blower speed control knob
COOKTOP LIGHTING
The LED lighting of this hood is controled by a rotary dimmer switch (1).The lighting turns on at high intensity, and decreases as the knob
is turned clockwise.
NOTE: When the light switch is turned on, there is a short delay before the lighting turns on; this short delay is normal.
If you experience lighting intensity issues after using the main power switch, cutting the power at service panel, or following a power
outage, turn the lighting to off by rotating the rotary dimmer switch counterclockwise until you hear a clik, and try again.
BLOWER
The blower is operated using two controls.
Use the on/off rocker switch (3) to start and stop the blower. When turned on, the blower indicator (2) turns on and the blower operates at
the previous setting of the speed control (4).
Turn the speed control knob clockwise to increase blower speed – counterclockwise to decrease speed.

15
17. WIRING DIAGRAMS
BLK
BLK BLACK
BLU BLUE
BRN BROWN
GRY GREY
ORG ORANGE
RED RED
WHT WHITE
YEL YELLOW
COLOR CODE
LINE
GROUND
NEUTRAL
120 VAC
USE ONLY WITH APPROPRIATE
MAKE-UP AIR SYSTEM
ORA
NEON
ORA ORA
FAN SWITCH
BLK
RED RED
THERMOSTAT
WHT
GRY
GRY
9408
AAAA
B
1
2
3
4
BLU
WHT
ORA
BLK
WHT
BLK
ORA
WHT
BLU
MAIN SWITCH
BLK BLK
GRY
WHT
YEL
WHT
BLU
WHT
ORA BLK
WHT
BLU
WHT
ORA
BLK
RED
M
M
BLOWER MOTOR
OPTIONAL SECOND
BLOWER MOTOR
HE0207A
LED
D
RIVER
LED
LED
BRN
GRY
LED CONTROL
IN J1
J2 OUT
WHT
WHT
SPEED CONTROL
HEAT SENTRY
THERMOSTAT BLU
BLK
BLK
BLU
GRY
WHT
BLK
YEL
BLK
ORA
NEON
ORA
M
REMOTE
BLOWER ASSEMBLY
RETURN
LINE
120 V
SUPPLY
ROUGH-IN PLATE
FAN
SWITCH
USE ONLY WITH
APPROPRIATE
MAKE-UP AIR SYSTEM
GROUND
HE0208A
COLOR CODE
Off 2
On 3 1
BLK BLK
WHT
BLK
GRN
WHTWHT
WHT
GRN
BLK
LED
D
RIVER
LED
LED
LED CONTROL
BLK BLACK
BLU BLUE
GRN GREEN
ORA ORANGE
WHT WHITE
YEL YELLOW
GRY GREY
IN J1
J2 OUT
Broan Elite E64000LC Series
Internal blower(s) hoods
Broan Elite E64000LC Series
Exterior or In-Line blower hoods

16
18. SERVICE PARTS
* NOT SHOWN.
1
2
34
5
6
7
89
10
11
12
13
14
15
HL0238
2
34
6
7
89
10 11 12 13
14
15
16
17
18
HL0239
* NOT SHOWN.
REPLACEMENT PARTS AND REPAIRS
In order to ensure your unit remains in good working condition, you must use Broan-NuTone genuine replacement parts only.Broan-NuTone genuine replacement parts are spe-
cially designed for each unit and are manufactured to comply with all the applicable certification standards and maintain a high standard of safety. Any third party replacement
part used may cause serious damage and drastically reduce the performance level of your unit, which will result in premature failing. Broan-NuTone recommends to contact a
certified service depot for all replacement parts and repairs.
Broan Elite E64000LC Series
Exterior or In-Line blower hoods
Broan Elite E64000LC Series
Internal blower hoods
KEY
NO.PART
NO.DESCRIPTION QTY. (HOOD WIDTH)
30"36"42"48"
1
SV13296
SV17797
ADAPTER/DAMPER 3¼" X10"
(1-BLOWER HOODS)
ADAPTER 4½" X18½" (2-BLOWER HOODS)
1
-
1
1
1
1
1
1
2 62612 LED MODULE (1) 2222
3 62248 LED DRIVER AND CONNECTOR HARNESS 1111
4 SV03435 HEAT SENTRYTM THERMOSTAT 1111
5 SV08582 INTERNAL MOTOR 1
1
2
1
2
1
2
6
SV17640
SV17641
SV17642
SV17643
GREASE RAIL 30"
GREASE RAIL 36"
GREASE RAIL 42"
GREASE RAIL 48"
1
-
-
-
-
1
-
-
-
-
1
-
-
-
-
1
7 SV08337 BAFFLE FILTER SPRING (SET OF 6) 1111
8SV17600
SV17603 BAFFLE FILTER 8.84" x 15.125"
BAFFLE FILTER 11.84" X15.125" 2
1-
32
2-
4
9 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3344
10 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1111
11 SV21722 SPEED CONTROL 1111
12 SV21248 LIGHT CONTROL WITH NUT 1111
13 SV08339 BLOWER ROCKER SWITCH 1111
14 SV08093 PILOT LAMP ASS'Y1111
15 SV06750 BROAN ELITE LOGO 1111
* SV21242 INSTALLATION GUIDE 1111
* SV08353
PARTS BAG: 2 WIRE CONNECTORS,
9 SCREWS NO. 8 X½", 1 WIRE CLAMP,
8 MECHANICAL SCREWS NO.8-32 X¼",
4SCREWS NO. 8 X3/8"
1111
KEY
NO.PART
NO.DESCRIPTION QTY. (HOOD WIDTH)
30"36"42"48"
2 62612 LED MODULE (1) 2222
3 62248 LED DRIVER AND CONNECTOR HARNESS 1111
4 SV03435 HEAT SENTRYTM THERMOSTAT 1111
6
SV17640
SV17641
SV17642
SV17643
GREASE RAIL 30"
GREASE RAIL 36"
GREASE RAIL 42"
GREASE RAIL 48"
1
-
-
-
-
1
-
-
-
-
1
-
-
-
-
1
7 SV08337 BAFFLE FILTER SPRING (SET OF 6) 1111
8SV17600
SV17603 BAFFLE FILTER 8.84" x 15.125"
BAFFLE FILTER 11.84" X15.125 2
1-
32
2-
4
9 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3344
10 SV08355 BLOWER AND LIGHT KNOBS (2 KNOBS) 1111
11 SV03501 SPEED CONTROL 1111
12 SV21248 LIGHT CONTROL WITH NUT 1111
13 SV08339 BLOWER ROCKER SWITCH 1111
14 SV08093 PILOT LAMP ASS'Y1111
15 SV06750 BROAN ELITE LOGO 1111
16 SV08354 ROUGH-IN PLATE 10" ROUND 1111
17 SV13923 FEMALE CONNECTOR 1111
18 SV13924 MALE CONNECTOR 1111
* SV21242 INSTALLATION GUIDE 1111
* SV08353
PARTS BAG: 2 WIRE CONNECTORS,
9 SCREWS NO. 8 X½", 1 WIRE CLAMP,
8 MECHANICAL SCREWS NO.8-32 X¼",
4SCREWS NO. 8 X3/8"
1111