38MURA: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
9
PERFORMANCE
NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, refer to the AHRI
directory www.ahridirectory.org
AIR HANDLER
Heat Pump (Standard Heat)
Heat Pump (High Heat)
Outdoor Size 1.5T 2T 2.5T 3T 4T 5T
M Ratings
Indoor Model 18K 24K 30K 36K 48K 60K
Energy Star NO NO NO NO NO NO
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 57,000
Cooling Cap. Range Min - Max Btu/h 5400~18700 7500~26000 9500~33000 8900~38900 10500~48000 4400~60200
SEER 19.0 19.4 19.5 18.0 17.3 18.0
EER 11.1 11.3 10.9 10.4 9.3 10.3
Heating Rated Capacity (47°F) Btu/h 18,500 26,000 31,000 36,000 55,000 60,000
Heating Rated Capacity (17°F) Btu/h 11,500 17,000 19,000 21,000 33,000 33,800
Heating Rated Capacity (5°F) Btu/h 9,500 17,000 20,000 21,000 27,000 29,000
Heating Cap. Range Min - Max Btu/h 5600~18700 5600~30000 12200~32000 6000~36400 11700~57000 11400~63100
HSPF 10.8 11.3 10.3 9.1 10.0 9.2
COP (47°F) W/W3.493.543.193.023.003.55
COP (17°F) W/W2.702.752.302.252.002.45
COP (5°F) W/W1.851.751.951.801.721.80
M1 Ratings
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 57,000
Cooling Cap. Range Min - Max Btu/h 5400~18700 7500~26000 9500~33000 8900~38900 10500~48000 4400~60200
SEER2 16.0 17.0 17.3 16.9 15.8 14.7
EER2 10.8 10.5 10.6 10.1 8.8 8.7
Heating Rated Capacity (47°F) Btu/h 18,000 26,000 31,000 36,000 55,000 60,000
Heating Rated Capacity (17°F) Btu/h 11,500 20,700 20,000 20,500 36,500 36,000
Heating Rated Capacity (5°F) Btu/h 10,000 17,000 17,800 21,000 36,500 34,800
Heating Cap. Range Min - Max Btu/h 5600~18700 5600~30000 12200~32000 6000~36400 11700~57000 11400~63100
HSPF2 8.7 9.1 8.5 8.2 9.4 8.4
COP (47°F) W/W3.503.453.253.393.153.45
COP (17°F) W/W2.752.402.452.402.302.35
COP (5°F) W/W1.902.001.751.881.981.89
Outdoor Size 1.5T - HH 2T - HH 2.5T - HH 3T - HH 4T - HH 5T - HH
M Ratings
Indoor Model 18K 24K 30K 36K 48K 60K
Energy Star YES YES NO NO NO NO
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 55,000
Cooling Cap. Range Min - Max Btu/h 6900~21000 6400~27000 10400~33600 12000~47400 18000~48000 18000~56000
SEER 20.0 20.0 18.0 18.0 16.0 16.4
EER 12.5 12.5 11 10.5 8.5 9
Heating Rated Capacity (47°F) Btu/h 19,000 24,000 33,000 41,500 50,000 59,000
Heating Rated Capacity (17°F) Btu/h 13,000 16,700 19,400 24,000 32,000 42,000
Heating Rated Capacity (5°F) Btu/h 19,000 24,000 28,500 34,500 47,000 50,000
Heating Cap. Range Min - Max Btu/h 2800~21000 10100~31000 12000~37000 9000~57200 20000~55000 20000~68000
HSPF 11.0 12.0 10.5 10.5 10.0 10.5
COP (47°F) W/W 3.59 3.45 3.48 3.45 3.00 3.50
COP (17°F) W/W 2.75 2.70 2.60 2.65 2.30 2.60
COP (5°F) W/W 1.90 1.80 1.95 1.80 1.88 1.96
M1 Ratings
Cooling Rated Capacity Btu/h 18,000 24,000 30,000 36,000 47,000 55,000
Cooling Cap. Range Min - Max Btu/h 6900~21000 6400~27000 10400~33600 12000~47400 18000~48000 18000~56000
SEER2 18.0 17.4 16.2 15.8 15.6 15.0
EER2 12.4 11.7 9.8 9.8 8.2 8.5
Heating Rated Capacity (47°F) Btu/h 19,000 24,000 33,000 41,000 50,000 59,000
Heating Rated Capacity (17°F) Btu/h 13,000 18,600 20,400 29,500 35,000 42,000
Heating Rated Capacity (5°F) Btu/h 16,500 22,700 24,100 34,500 46,000 50,000
Heating Cap. Range Min - Max Btu/h 2800~21000 10100~31000 12000~37000 9000~57200 20000~55000 20000~68000
HSPF2 9.2 9.8 8.8 9.5 9.3 9.0
COP (47°F) W/W 3.60 3.40 3.30 3.35 3.15 3.00
COP (17°F) W/W 2.50 2.40 2.30 2.40 2.30 2.60
COP (5°F) W/W 2.00 1.85 1.80 1.95 1.90 1.96