INSTALLATION AND OPERATING INSTRUCTIONS | 98 | INSTALLATION AND OPERATING INSTRUCTIONS
SIDE BUTTONS
NETWORK SETUP toggles display of the network settings in the main display
screen. By default it does not appear. To change IP, Subnet and Gateway
parameters, enter values required, and press “APPLY”. The new values are
recorded in non-volatile memory. If the IP address is changed, the web
browser must be re-started using the new address. To change the MAC
address, type in the new address and press “SET MAC”.
DIAGNOSTICS toggles display of the diagnostic information on the main
display screen. By default it does not appear. This display is normally only
used for troubleshooting.
STORAGE MODE allows the user to de-activate the batteries for storage
mode or shipment. To put the unit in storage mode, first disconnect the AC
power. The AC POWER status should change from ON to OFF. Then press the
“STORAGE MODE” button. Confirm that you want to put the unit into storage
mode. The unit will turn off. All connected loads will be turned off. The page
will stop responding. The unit is now in storage mode.
POWER STATUS
AC POWER reads ON and is green when present, OFF and is red when absent.
MAX CAPACITY indicates the total installed battery capacity. It is in multiples
of 350WH.
REMAINING CAPACITY when AC power is present indicates the capacity to
which the batteries are currently charged.When AC power is absent, it shows
the amount of capacity remaining.
RESOURCE LEVEL is the ratio of remaining capacity to max capacity
expressed as a percentage.
EST TIME is the estimated battery run time while running at the current load
indicated in the Port Power and Status fields.
EST EXTENDED TIME is the estimated battery run time when the Programmed
Shutdown levels are set.
PORT STATUS
STATUS is 1 if the port is providing PoE power, 0 if not. POWER displays the
power taken by each port. NETWORK displays the port speed, whether the
port is providing power on not.
PROGRAMMED SHUTDOWN allows the user to set capacity thresholds at
which, during absence of AC power, each PoE port will be turned off. This
enables essential services to be maintained for as long as possible in the
event of a prolonged power outage.
UNIT CONFIGURATION
The unit is shipped and stored with the batteries de-activated. In this
state, the unit can be stored for up to 3 months if kept in the temperature
range -20°C and +50°C. To “wake up” the unit, plug it into an AC outlet.
Once awake, the unit will stay awake until it is either put in storage mode
again, or the batteries run flat without AC power. Depending on the storage
capacity installed, their charge status, and any load, the batteries will be
flat in anywhere between a few hours to a few weeks.
To put the unit back into storage mode, you should be connected to it with
a computer. Please see later for complete details.
To configure the unit, connect a computer with a web browser to the unit.
The default IP address is 192.168.100.55
You should be rewarded with the SolidSwitch Command Post Screen
as below.
EDS-SSINSTMN-082018A EDS-SSINSTMN-082018A