Bubble Magus BM T-01 User manual

1
BM T-01 instruction manual
Transformers Power: I / P: AC 100-240V 50-60Hz 0.36A O / P: DC 12V 1A
Quantitative Accuracy: better than ± 10%
Size: 235x160x70mm (without transformer power supply)
BM-T01 dosing pump is an advanced computerized controller unit. By itself, the BM T-01 can operate three
independent pump heads, using various adjustments. Each pump head on the unit or extending from unit can be
configured separately within the specified range of 1ml to 1999ml, and divided into different intervals of a 24hr day.
The BM-T01 is a master controller, and it can operate with two other BM-T02 extension/slave units (sold separately).
With each extension unit having the capacity of four more pump heads, the maximum number of pump heads for
which the BM T-01 can manage in a configured is 11 pump heads.
In addition, this product has a data protection feature. In the case of a power outage (blackout or brownout), the
BM-T01 can retain its settings up to 24 hours.
Thank you choosing BUBBLE-MAGUS. Please read the instructions carefully before use. If you encounter any
issues, whether it is in the packaging, during your installation, or during normal operation of your product, contact
support@seasideaquatics.com for further support. Be sure to register your product to activate your warranty.
BM-T01 Packing List
No.
Name
Amount
Notes
1
Quantitative pump control box of the main
1PCS
3 pump head with 3 hose
2
Power Transformer
1PCS
3
Instructions
1PCS
4
PVC transparent pipe
3M
5
Hose connector
6PCS
Installation
1. Locate a sturdy and secure platform, and place the unit horizontally in an upright position as illustrated in the
figure below. The dosing pump control box should be housed in a dry, cool, and clean area. Moisture,
debris, or excessive heat may result in electrical failure (not covered by the warranty).

2
2. Connect the hose connectors to the inlet and outlets tubes of each pump head as illustrated above.
3. Proceed to connect the PVC line to each connector. Each PVC line should be cut to the appropriate length of
your configuration.
4. When facing of the pump heads, the PVC line connected to the inlet port on the left side needs to be routed to
your supply of additives. Whereas, the line connected to the right outlet should be routed to your tank.
NOTE: The pump is designed for aquarium additives only. Strong acids or other chemicals like alkali
solutions are not suitable.
5. Lastly, connect the power transformer/supply to the unit. Double check all your connections to ensure that
they are safe and secure.
6. Turn on the unit. The screen should show the clock as 00:00:00 (initial state).
Clock settings:
1. In the initial state, press ESC key, and then press the UP or DOWN button until the screen display SETUP
CLOCK.
2. Press the ENTER button to access the clock setting mode. Press UP or DOWN to increase or decrease the
values.
3. Press ENTER to confirm and proceed to the next digit.
4. To finalize your adjustments, press ENTER again to exit the clock adjustment
Manual control mode (for priming or testing):
1. In the initial state, press ESC, select MANUAL CONTORL, and press ENTER.
Bubble-Magu
s00:00:0
0
SetClock
10:00
MANUAL
CONTOR
L

3
2. The screen will show PUMP01. Press UP or DOWN to select from PUMP01-PUMP11.
3. After selecting the desired pump head. Press and hold the ENTER key to activate the flow of liquid.
Release the button to stop operation.
4. Press ESC to exit the manual control mode.
NOTE:
Without the expansion unit (BM-T02), the BM-T01 dosing pumps should only show PUMP01, PUMP02, and
PUMP03.
Program control mode:
Below is an overview of the procedure for adjusting the pump’s total dosage, frequency of delivery, and starting time.
1. Pump Selection
In the initial state, press ESC key. Press the UP or DOWN to select SETUP PROGRAM
Press ENTER. The screen will display the group of head pumps to adjust, like SETUP P 1-3.
Press ENTER. The screen will display the individual pump for configuration, like SETUP PUMP 1.
Press the UP or DOWN key to select the desired pump.
2. Total Dosage Quantity
After selecting the desired pump, select the daily amount of liquid to add (range of 1 ~ 1999ml) per 24 hours. The
figure to the right shows PUMP1 as being selected.
At this point:
Select the dosage quantity (ml) by pressing UP or DOWN to change the value of the selected digit.
Press the ENTER key to advance to the next digit.
Example: P 1:0888 signifies that in 24 hours, PUMP1 will add 888ml wroth of solution.
3. Frequency (cycles per day)
After confirming the total dosage, the user may then select the frequency of the dosage per 24 hours.
The screen to the right, CYCL / DAY P1 8, shows the total dosage being pumped 8 times a day (every 3hrs).
Press UP or DOWN to change the number.
Press ENTER to confirm.
NOTE: ‘24’points is the maximum value (total dosage is delivered in the increments of once per hour, 24 time
a day). In contrast, ‘1’is the minimum value (total dosage is delivered all at once, 1 time a day).
4. Set Start Time
After confirming the frequency of dosage, the user may set the start time.
The default screen is START: 00:00.
Press UP or DOWN to adjust the set of digits, ranging from 00 to 23.
Press ENTER to confirm and to proceed to the next set.
After finalizing your hour and minutes, press ENTER again.
The screen will display Saving ..., stating that your settings are being saved per pump head.
Press the ENTER key to confirm.
SETUP
PROGRAM
ml/DAY
P 1:0000
CYCL/DAY
P 1 8
START:
00:00

4
To adjust the other head pumps, press the ESC key to access the selection screen or to return to the previous
menu.
NOTE:
Although you can set the starting time for various pump to be the same, the system is calibrated to deliver
each dosages at different intervals. When there is a time overlap, the pump is readjusted for each 5-minute intervals.
For example, when all three pumps can be set to 01:00 start, PUMP1’s start time is at 01:00, but PUMP2’s actual start
time is at 01:05; and PUMP3’s actual start time is at 1:10).
5. To Finish
After everything is set up, press ESC until the screen shows the current clock (time is in 24hr intervals, not
12hr).
Your settings will take effect automatically.
Expansion unit configuration:
The BM-T01 has a back panel that allows it to connect with the BM-T02 extension pump unit. The expansion unit
can unlock "SETUP P 4-7" and "SETUP P 8-11" configurations for additional pump head control.
Table: The total dosage that can be administered how many times a day.
Total Dosage (ml)
Cycles per day
1
1, 2
2
1, 2, 3, 4
3
1, 2, 3, 4, 6
4, 5
1, 2, 3, 4, 6, 8
6-11
1, 2, 3, 4, 6, 8, 12
12-160
1, 2, 3, 4, 6, 8, 12, 24
161-319
2, 3, 4, 6, 8, 12, 24
320-479
3, 4, 6, 8, 12, 24
480-639
4, 6, 8, 12, 24
640-959
6, 8, 12, 24
960-1279
8, 12, 24
1280-1919
12, 24
1920-1999
24
Table of contents
Popular Water Pump manuals by other brands

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS VS6A60-B Installation, operation, and maintenance manual with parts list

Crane
Crane Barnes SGV 2 HP Service manual

MYERS
MYERS MC50 owner's manual

BEDU
BEDU SD Series operating instructions

Elmo Rietschle
Elmo Rietschle C-VLR 62 OXY operating instructions

Rheem
Rheem Raypak RPVSP1 Installation and operation manual