manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. build
  6. •
  7. Ventilation Hood
  8. •
  9. build MISENO MH70230AS User manual

build MISENO MH70230AS User manual

This manual suits for next models

2

Other build Ventilation Hood manuals

build MISENO MH00230G User manual

build

build MISENO MH00230G User manual

build MH00330G User manual

build

build MH00330G User manual

build MISENO MH00529S User manual

build

build MISENO MH00529S User manual

Popular Ventilation Hood manuals by other brands

Gorenje S3 IHGC963S4X manual

Gorenje

Gorenje S3 IHGC963S4X manual

KOBE ISX2136SQB-1 Installation instructions and operation manual

KOBE

KOBE ISX2136SQB-1 Installation instructions and operation manual

U.S. Products ADVANTAGE-100H Information & operating instructions

U.S. Products

U.S. Products ADVANTAGE-100H Information & operating instructions

Kuppersberg DUDL 4 LX Technical Passport

Kuppersberg

Kuppersberg DUDL 4 LX Technical Passport

Framtid HW280 manual

Framtid

Framtid HW280 manual

Thermador HGEW 36 FS installation manual

Thermador

Thermador HGEW 36 FS installation manual

Electrolux LFT769X user manual

Electrolux

Electrolux LFT769X user manual

AEG X69453MVO UK user manual

AEG

AEG X69453MVO UK user manual

Broan B5836SS manual

Broan

Broan B5836SS manual

Heinner HDCH-6060RGBK quick start guide

Heinner

Heinner HDCH-6060RGBK quick start guide

Baumatic AS35SS instruction manual

Baumatic

Baumatic AS35SS instruction manual

Franke FTF 604 XS V2 Instructions for use and installation

Franke

Franke FTF 604 XS V2 Instructions for use and installation

Best UCB3I30SBW installation instructions

Best

Best UCB3I30SBW installation instructions

Gram EFU 503-90 X instruction manual

Gram

Gram EFU 503-90 X instruction manual

CIARRA CBCS6803 Installation and user manual

CIARRA

CIARRA CBCS6803 Installation and user manual

sauter SHG501 Instructions for installation and use

sauter

sauter SHG501 Instructions for installation and use

Franke 392-17 User instructions

Franke

Franke 392-17 User instructions

FALMEC Polar Black 35 Instruction booklet

FALMEC

FALMEC Polar Black 35 Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation, Use and Care Guide
READ AND SAVE THESE INSTRUCTIONS
2014.NOV
MH70230AS
MH70236AS
MH70248AS
MODEL #.
1
SAFETY NOTICE................................................................. 2-3
LIST OF MATERIALS....................................................... 4
INSTALLATION
Ducting Calculation Sheet....................................... 5
Mounting Height & Clearance................................ 6
Ducting Options........................................................... 7
6SHFL¿FDWLRQV ............................................................... 8
Electrical......................................................................... 9
Mounting the Range Hood...................................... 10
Horizontal Ducting Conversion.............................. 11
FEATURES & CONTROLS
Rotary Dial..................................................................... 12
MAINTENANCE
Cleaning and Filter Removal.................................. 13
Lights................................................................................ 14
TROUBLESHOOTING................................................................ 15
WIRING DIAGRAMS................................................................... 16
LIST OF PARTS AND ACCESSORIES.............................. 17
WARRANTY.................................................................................... 18
Table of Contents
Important Safety Notice
READ AND SAVE THESE INSTRUCTIONS
2
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE.
WARNING
TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off at service panel and lock panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. Take care when using cleaning
agents or detergents. Suitable for use in household cooking area.
WARNING
TO REDUCE THE RISK OF RANGE TOP GREASE FIRE:
a. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly
on low or medium settings.
E $OZD\VWXUQKRRG21ZKHQFRRNLQJDWKLJKKHDWRUZKHQÀDPLQJIRRG
F &OHDQYHQWLODWLQJIDQVIUHTXHQWO\*UHDVHVKRXOGQRWEHDOORZHGWRDFFXPXODWHRQIDQRU¿OWHU
d. Use proper pan size. Always use cookware appropriate for the size of the surface element.
H .HHSIDQ¿OWHUVDQGJUHDVHODGHQVXUIDFHVFOHDQ
f. Use high setting on hood only when necessary.
g. Don’t leave hood unattended when cooking.
h. Always use cookware and utensils appropriate for the type of and amount of food being prepared.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE, OBSERVE THE FOLLOWING:
D 6027+(5)/$0(6ZLWKDFORVH¿WWLQJOLGFRRNLHVKHHWRUPHWDOWUD\WKHQWXUQRIIWKHEXUQHU%(&$5()8/7235(9(17%8516
,IWKHÀDPHVGRQRWJRRXWLPPHGLDWHO\(9$&8$7($1'&$//7+(),5('(3$570(17
b. NEVER PICK UPA FLAMING PAN – You may be burned.
c. DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
d. Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
 7KH¿UHLVVPDOODQGFRQWDLQHGLQWKHDUHDZKHUHLWVWDUWHG
 7KH¿UHGHSDUWPHQWLVEHLQJFDOOHG
 <RXFDQ¿JKWWKH¿UHZLWK\RXUEDFNWRDQH[LW
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
D ,QVWDOODWLRQZRUNDQGHOHFWULFDOZLULQJPXVWEHGRQHE\TXDOL¿HGSHUVRQVLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHVDQGVWDQGDUGV
,QFOXGLQJ¿UHUDWHGFRQVWUXFWLRQ
E 6XI¿FLHQWDLULVQHHGHGIRUSRZHUFRPEXVWLRQDQGH[KDXVWLQJRIJDVHVWKURXJKWKHÀXHFKLPQH\RIIXHOEXUQLQJHTXLSPHQWWRSUHYHQW
back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National
)LUH3URWHFWLRQ$VVRFLDWLRQ1)3$DQGWKH$PHULFDQ6RFLHW\IRU+HDWLQJ5HIULJHUDWLRQDQG$LU&RQGLWLRQLQJ(QJLQHHUV$6+5$(DQG
the local code authorities.
c. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
d. Ducted fans must always vent to the outdoors.
e. NEVER place a switch where it can be reached from a tub or shower.
f. Make sure the power is off before installing, wiring or maintenancing.
Important Safety Notice
3
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
CAUTION
7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV
attics, crawl spaces or garages.
OPERATION
$OZD\VOHDYHVDIHW\JULOOHVDQG¿OWHUVLQSODFH:LWKRXWWKHVHFRPSRQHQWVRSHUDWLQJEORZHUVFRXOGFDWFKRQWRKDLU¿QJHUV
and loose clothing.
The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to
negligence and the warranty of the unit automatically expires due to improper maintenance.
ELECTRICAL REQUIREMENTS
Important:
Observe all governing codes and ordinances.
It is the customer’s responsibility:
 7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU
- To assure that the electrical installation is adequate and in conformance with National Electrical Code,ANSI/NFPA 70
latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
,IFRGHVSHUPLWDQGDVHSDUDWHJURXQGZLUHLVXVHGLWLVUHFRPPHQGHGWKDWDTXDOL¿HGHOHFWULFLDQGHWHUPLQHWKDWWKH
ground path is adequate.
Do not ground to a gas pipe.
&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHQRWVXUHWKHUDQJHKRRGLVSURSHUO\JURXQGHG
Do not have a fuse in the neutral or ground circuit.
*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575
This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit
protected by a 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to
Electrical Diagram on product.
$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWVSXUFKDVH
and install appropriate connector if necessary.
List of Materials
4
MODELS: MH70230AS, MH70236AS, MH70248AS
PARTS SUPPLIED
1 - Hood
%DIÀH¿OWHUVIRU0+$6
+DORJHQOLJKWEXOEVpre-installed
1 - 10” round transition adapter
1 - Top Ducting Cover Plate
1 - Hardware package
HARDWARE PACKAGE CONTENTS
PARTS NOT SUPPLIED
- Ducting, conduit and all installation tools
&DEOHFRQQHFWRULIUHTXLUHGE\ORFDOFRGHV
- Duct Cover Accessory
- Backsplash Accessory
Light Bulb Removal
Suction Cup (1)
M6 x 1” (4)
M6 x 1-1/2” (4)
M6 x 2” (4)
M4 x 8 (4)
Wire Caps (3)
:RRG%RDUGWRKDQJKRRG:['[+
MH70230AS - 27” x 1/2” x 4”
MH70236AS - 33” x 1/2” x 4”
MH70248AS - 45” x 1/2” x 4”
5
Installation – Ducting Calculation Sheet
Duct pieces To t a l
Equivalent number
length x used =
3-1/ 4” x 10”
Rect.,
straight
1 Ft. x ( ) = Ft.
7”-10” Round,
straight
1 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
elbow
15 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.450
elbow
9 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.900
flat elbow
24 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
5 Ft. x ( ) = Ft.
3-1/ 4” x 10”
Rect.to
6” round
transition
900elbow
20 Ft. x ( ) = Ft.
6” Round,
900elbow
15 Ft. x ( ) = Ft.
6” Round,
450elbow
9 Ft. x ( ) = Ft.
Ft.
6” Round,
straight
1 Ft. x ( ) = Ft.
Subtotal column 1 =
Duct pieces To t a l
Equivalent number
length x used =
6” Round
wall cap
with damper
30 Ft. x ( ) = Ft.
Round
wall cap
with damper
30 Ft. x ( ) = Ft.
7” - 10”
Round,
900elbow
15 Ft. x ( ) = Ft.
7” - 10”
7” - 10”
Round,
450elbow
9 Ft. x ( ) = Ft.
Ft.
Ft.
Ft.
6” Round,
roof cap
30 Ft. x ( ) = Ft.
7” - 10”
Round,
roof cap
30 Ft. x ( ) = Ft.
Subtotal column 2 =
Subtotal column 1 =
Total ductwork =
6” round to
3-1/ 4” x 10”
rect.
transition
1 Ft. x ( ) = Ft.
6” round to
3-1/ 4” x 10”
rect.
transition
900elbow
16 Ft. x ( ) = Ft.
7” round to
3 1/ 4” x 10”
rect.
transition
8 Ft. x ( ) = Ft.
7” round to
3-1/ 4” x 10”
rect.
transition
900elbow
23 Ft. x ( ) = Ft.
Maximum Duct Length: For satisfactory air movement,
the total duct length should not exceed 100 equivalent feet.
Installation – Mounting Height & Clearance
6
DUCTING
A minimum of 10” round duct must be used to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
$OVRXVHFDOFXODWLRQRQSDJHWRFRPSXWHWRWDO
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORVHLWVSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
10” round minimum
Horizontal Ducting:
10” round minimum
DAMAGE-SHIPMENT / INSTALLATION:
 3OHDVHIXOO\LQVSHFW XQLWIRUGDPDJHEHIRUH
installation.
 ,IWKHXQLWLVGDPDJHG LQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
 ,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
 ,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
18"
36"
*Min 92”
*Max 102"
Min 26" - Max 36"
12"
*with optional 12" duct cover
7
WARNING FIRE HAZARD
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
All exhaust must be ducted to the outside.
Use metal ductwork only.
)DVWHQDOOFRQQHFWLRQVZLWKVKHHWPHWDOVFUHZVDQGWDSHDOOMRLQWVZLWKFHUWL¿HG6LOYHU7DSHRU'XFW7DSH
Some Ducting Options
Installation – Ducting Options
Soffit or crawl space
Roof Pitch w/
Flashing & Cap
Rear Ducting
Side wall cap
w/ gravity damper
8
Installation – 6SHFL¿FDWLRQV
Top View Side View
Back View
Ducting & Electrical Dimensions
12”
24”
4”
18”
8 9/16”
1 3/4”
1 1/16”
11 9/16”
6”
10 3/8”
14 3/16” 2 3/4”
9 15/16”
10 3/8”
4 5/16”
11 9/16”
10 3/4”
10 3/8”
14 3/16”
9 15/16”
1 11/16”
29 7/8” (30”)
35 7/8” (36”)
47 7/8” (48”)
C/L
C/L
Back View
Mounting Dimensions
16 7/8”
16 1/8”
13 5/8”
1 11/16”
3 5/16”
21 1/4”
27 3/8” (36“), 35 1/4” (48”)