The Plus-X ICRU communicates with the ARC Plus Touch or ARC Plus SL via
LAN/WAN, allowing installation anywhere a network connection is available.
Use AutoLoad Plus to add the
Plus-X device to the ARC Plus
Touch or ARC Plus SL unit. Ensure
you have the current version
of AutoLoad Plus installed on
your computer. To obtain the
current version, visit www.burk.
com/downloads and select the
AutoLoad Plus support page. On
the AutoLoad Plus menu, select
Edit->Plus-X Devices and click Add.
The dialog box shown to the right
will be displayed.
•Select Plus-X ICRU and enter its network information.
Note: If adding more than one Plus X device to an ARC Plus, change the
starting channel so that other assigned channels are not overwritten.
The Plus-X ICRU allows connection of 8 raise and 8 lower channels. Raise channels connect to the left
set of 24 pins on the rear panel and lower channels connect to the right set of 24 pins.
4CONNECTING TO AN ARC PLUS TOUCH OR
ARC PLUS SL
3CONNECTING RELAYS ON THE PLUS-X ICRU
2NETWORK SETUP (CONTINUED)
10. To verify communication, open a command prompt on your computer and ping the
address you just assigned to the unit to ensure it is correctly configured.
QUICK START GUIDE
1. Connect your site equipment to the provided 24-pin or
3-pin push-on block connectors. Secure the wires with
the built-in setscrews. Connections are standard, from
left to right: common (C), normally open (NO), and
normally closed (NC)
2. Connect the push-on blocks to the rear panel of the
Plus-X ICRU with the setscrews facing up. Use care to
properly align each terminal with the contacts on the
back panel of the unit.
e. ARC Plus IP address – Enter the IP address of the ARC Plus Touch or ARC Plus SL unit that the Plus-X
ICRU will be connected to.
f. HTTP Port – Check with your network administrator. The factory default setting is port 80.
g. Plus-X Port – Check with your network administrator otherwise the factory default setting can be
used. This port must match the setting for Plus-X Port on your ARC Plus Touch or ARC Plus SL unit.
•Select OK to conrm the rst Plus X device.
•If adding more than one Plus X device, repeat the same steps.
•Save the conguration by selecting File>Save in AutoLoad Plus
To conrm that the Plus-X ICRU is communicating, log in to the ARC Plus
Touch or ARC Plus SL using the web browser. All assigned channels should
show their default values.
MANUALLY MAPPING PLUS-X CHANNELS
1. To manually map Plus-X channels to the ARC Plus, click the Command
tab. Locate an unused channel and click the […] button in the Source
column. This will bring up the Source dialog. Click the Plus-X button and
choose the Plus-X device and channel you wish to use.
2. Use the Commands tab in AutoLoad Plus to congure additional relay
settings for the newly added Plus-X ICRU channels.
3. Select File>Save to save the changes to the ARC Plus.
Note: If the channels show as ofine or a warning is displayed, check the
network conguration and ensure the conguration is saved within AutoLoad
Plus.
Refer to the Plus-X ICRU Installation and Operation Manual for further
information on conguring and operating the Plus-X ICRU unit.
The 16 relays on the Plus-X ICRU may be used as raise/
lower pairs or individually as up to 16 command channels.
To congure the relay behavior, use a web browser to
connect to the Plus-X ICRU. Click on the Conguration
link in the menu bar then click on Relay Settings from the
sidebar.
Click the Pair checkbox in the center column to pair the
associated relays (1 and 9, 2, and 10, etc.). When paired,
the relays will behave as one raise/lower channel. When
not paired, each relay behaves independently.
Connecting a Relay Output
For information on conguring command outputs, see the Plus-X ICRU Installation & Operation Manual.
Plus-X ICRU