Doepke Dupline DSM 2 User manual

3931170/02/05/E
Doepke
Dupline
Zweifach-Relaisausgabe DSM 2
mit Halbleiter-Ausgängen
Two-Way Relay Output DSM 2
with Semiconductor Outputs
Bedienungsanleitung
Operating Instructions
Inhaltsverzeichnis
1. Allgemeines.............................. 2
2. Kodierung................................. 2
3. Inbetriebnahme ........................ 2
4. Anzeigen .................................. 3
5. Technische Daten .................... 3
6. Garantie ................................... 4
13. Anschlussschema / Connection
Diagram.................................... 8
Table of Contents
7. General Information ................. 5
8. Coding...................................... 5
9. Putting into Service .................. 5
10. Indicators.................................. 6
11. Technical Data ......................... 6
12. Guarantee ................................ 7
13. Anschlussschema / Connection
Diagram.................................... 8

2 3931170/02/05/E
Doepke
Bedienungsanleitung
Dupline Zweifach-Relaisausgabe DSM 2
1. Allgemeines
Das DSM 2 ist eine Komponente des Dupline-Installationssystems und ermöglicht das
Schalten von zwei unabhängigen Verbrauchern, die auf verschiedene Phasen aufgeteilt
sein dürfen. Jeder Verbraucher darf dabei eine Stromaufnahme von bis zu 16 A aufwei-
sen.
Der Schaltzustand der Relais wird durch zwei LEDs in der Front des Gehäuses ange-
zeigt.
Das DSM 2 erlaubt zudem den Anschluss von weiteren vier Verbrauchern mit einer
Spannungsversorgung von 24 VDC und einer Stromaufnahme von bis zu 50 mA pro Ka-
nal. Diese Verbraucher können z.B. Steuereingänge von Komponenten des SI-Systems
sein.
Die in der frontseitigen Kodier- und Testbuchse angebrachte, grüne LED zeigt die ord-
nungsgemäße Arbeitsweise des Dupline-Bussignals an.
Die Schaltrelais sind remanent ausgeführt, was zu einer Zustandsspeicherung bei Aus-
fall der Versorgungsspannung führt. Ein fehlerhaftes Dupline-Signal führt wahlweise zu
einer Zwangs-Einschaltung oder -Ausschaltung aller Ausgänge.
2. Kodierung
Mit dem Handkodiergerät DHK 1 kann über die Modularbuchse an der Front des DSM 2
jedem Schaltkanal jede beliebige Adresse zwischen A1 und P8 zugeordnet werden. Die
Kanalzuordnung ist wie folgt:
Funktionen, die nicht benötigt werden, sollten unkodiert bleiben. Die Kodierung des
DSM 2 kann ohne Versorgungsspannung oder Dupline-Signal vorgenommen werden.
Sie bleibt dauerhaft erhalten, kann aber jederzeit überschrieben werden.
Die Ausgänge sind ab Werk so konfiguriert, dass sie bei Busausfall eingeschaltet wer-
den. Diese Konfiguration kann ebenfalls mit dem DHK 1 geändert werden (wie in der Be-
dienungsanleitung für den DHK 1 beschrieben). Bei Konfiguration des Wertes „0“
werden bei Busausfall alle Ausgänge ausgeschaltet, bei „1“ eingeschaltet.
3. Inbetriebnahme
Die Installation darf nur von einer autorisierten Fachkraft vorgenommen werden. Bei der
Installation ist das Anschlussschema zu beachten. Alle anzuschließenden Leitungen
müssen spannungsfrei sein. Verbindungen zwischen dem Dupline-Signal und der 24V-
Versorgung sowie Verbindungen zum Erdpotenzial führen zu Störungen und sind nicht
zulässig. Auf die richtige Polarität der Versorgungsspannung und des Dupline-Signals ist
zu achten.
Kanal Beschreibung Kanal Beschreibung
1 Relais-Ausgangssignal 1 5 Halbleiter-Ausgangssignal C5
2 Relais-Ausgangssignal 2 6 Halbleiter-Ausgangssignal C6
3 Nicht belegt 7 Halbleiter-Ausgangssignal C7
4 Nicht belegt 8 Halbleiter-Ausgangssignal C8

3931170/02/05/E 3
Doepke
Da die Halbleiterausgänge nicht kurzschlussfest sind, ist bei deren Anschluss besonde-
re Vorsicht geboten.
Folgende Tabelle zeigt die Anschlussbelegung:
Um den Forderungen für Schutzkleinspannung zu genügen, ist bei der Installation die
VDE0100, Teil 410, zu beachten und anzuwenden.
Bitte achten Sie beim Anschluss darauf, dass das maximale Drehmoment der Klemmen
von 0,6 Nm nicht überschritten wird.
Das patentierte Schnappsystem erlaubt ein einfaches Entfernen des Gerätes von der
Hutschiene indem das Gehäuse bis zum Ausrasten hochgeschoben wird.
4. Anzeigen
5. Technische Daten
Klemme Beschreibung Klemme Beschreibung
1.1 Schaltkanal 1 (LIN) 1.2 Halbleiterausgang C5
1.5 Schaltkanal 1 (LOUT) 1.6 Halbleiterausgang C6
2.1 Schaltkanal 2 (LIN) 2.2 Halbleiterausgang C7
2.5 Schaltkanal 2 (LOUT) 2.6 Halbleiterausgang C8
1.3 Dupline Signalleiter - (Dupline-) 1.7 Dupline Signalleiter + (Dupline+)
1.4 0 VDC Betriebsspannung 1.8 +24 VDC Betriebsspannung
Anzeige Beschreibung
Grüne „BUS OK“-
LED
Dupline-Bus:
Aus: Busstörung / An: Bus OK
2 rote LED „EIN“ Schaltrelais 1..2:
Aus: Relais offen / An: Relais geschlossen
Min. Typ. Max.
Dupline
Stromaufnahme 10 µA
Eingangskanäle Keine
Ausgangskanäle 6 Steuerkanäle (2 Relais-/4 Halbleiterausgänge)
Halbleiterausgänge
Art PNP-Transistoren, gegen 0 V schaltend
Spannung 21,5 VDC 24 VDC 26,5 VDC
Belastbarkeit 50 mA
Relaisausgänge
Art Schaltrelais
AC
Spannung 12 VAC 250 VAC
Nennstrom (pro Ausgang) 100 mA 16 A
DC
Spannung 12 VDC 30 VDC
Nennstrom (pro Ausgang) 100 mA 10 A

4 3931170/02/05/E
Doepke
6. Garantie
Für fachgerecht montierte, unveränderte Geräte gewähren wir ab Kauf durch den End-
verbraucher die gesetzliche Gewährleistungsfrist. Die Garantie bezieht sich nicht auf
Transportschäden sowie Schäden, die durch Kurzschluss oder Überlastung entstanden
sind. Bei Fertigungs- und Materialfehlern, die innerhalb der Gewährleistungsfrist erkannt
werden, leistet unser Werk kostenlosen Ersatz. Bei Öffnen des Gerätes erlischt der Ga-
rantieanspruch.
Lampenlastena
Glühlampen 3000 W
HV-Halogenlampen 2500 W
Leuchtstofflampen 2400 W
Leuchtstofflampen mit EVG 600 W
Gasentladungslampen max. 1000 W (70 µF), 1250 W (100 µFb)
Kondensator zur Kompensation max. 70 µF, (100 µFb)
Energiesparleuchten mit KVG 1250 W
Energiesparleuchten mit EVGc300 W
Betriebsspannung
Nennbetriebsspannung 21,5 VDC 24 VDC 26,5 VDC
Stromaufnahme 3 mA 5 mA 8 mA
Erlaubte Brummspannung 100 mVpp
Anschlüsse
Art Zugbügelklemmen
Klemmbereich 0,4 mm ∅2,5 mm²
Drehmoment 0,6 Nm
Gehäuse
Art Verteilereinbaugehäuse nach DIN43880 für Hut-
schienenmontage nach DIN EN 50022
Maße 35 x 85 x 58 (B x H x T in mm) / 2 TE
Material Polycarbonat
Allg. technische Daten
Betriebstemperatur -10°C +45°C
Luftfeuchtigkeit max. 85% (Betauung nicht zulässig)
Schutzart / Normen IEC60669, EN55022 / EN50081-1 und EN55024
/ EN50082-1
Bestellnummer, -bezeichnung 09 501 105, Zweifach-Relaisausgabe DSM 2
a. Die Angaben beziehen sich auf eine Mindestlebensdauer von 25000 Schaltspielen und
den Anschlussbedingungen nach IEC60669.
b. mindestens 5000 Schaltspiele
c. Diese Angaben sind stark herstellerabhängig - ggf. bitte anfragen.
Min. Typ. Max.

3931170/02/05/E 5
Doepke
Operating Instructions
Dupline Two-Way Relay Output DSM 2
7. General Information
The DSM 2 is a component of the Dupline installation system. It permits the switching of
two independent loads, which may be operated on different phases. Each load can have
a current consumption of up to 16 A.
The switching status of the relays is indicated by two LEDs on the front of the device.
The DSM 2 also provides for the connection of four additional loads with a power supply
of 24 VDC and a current consumption of up to 50 mA per channel. These loads could be
e.g. control inputs from components of the SI Building management System.
The green LED located in the frontal coding and test socket indicates that the Dupline
bus signal is functioning properly.
The all-or-nothing relays are designed for retentivity, which means that their status is
stored should a power failure occur. A faulty Dupline signal will result in all outputs being
automatically either switched on or switched off.
8. Coding
With the hand encoder DHK 1 each channel can be assigned any address between A1
and P8 using the modular plug at the front of the DSM 2. The channel allocation is as
follows:
Functions which are not required should remain uncoded. Coding the DSM 2 can be car-
ried out without supply voltage or Dupline signal. Although it is permanently retained, it
may always be overwritten.
The outputs are configured at the works so that they are switched on if a bus failure oc-
curs. This configuration can also be changed with the DHK 1 (as described in the Ope-
rating Instructions for the DHK 1). If the value "0" is configured all outputs are switched
off in the event of a bus failure; if "1" is set; they are switched on.
9. Putting into Service
Commissioning may only be carried out by an authorised trained technician. Observe the
connection diagram when installing. All lines to be connected must be dead. Connec-
tions between the Dupline signal and the 24V supply, or connections to earth potential,
will cause malfunctions and are not permissible.
Check that the polarity of the supply voltage and the Dupline signal are correct.
As the semiconductor outputs are not short-circuit-proof, special care has to be taken
with their connection.
Channel Description Channel Description
1 Relay output signal 1 5 Semiconductor output signal C5
2 Relay output signal 2 6 Semiconductor output signal C6
3 Not assigned 7 Semiconductor output signal C7
4 Not assigned 8 Semiconductor output signal C8

6 3931170/02/05/E
Doepke
The following table shows the allocation of terminals:
In order to meet the requirements for protective low voltage, VDE0100, Part 410, should
be observed and put into practice during installation.
When connecting please observe that the maximum torque of the terminals of 0.6 Nm
will not be exceeded.
The patented click-and-lock-mechanism allows an easy removal of the unit from the rail
by pushing the housing upwards until it is released.
10. Indicators
11. Technical Data
Terminal Description Terminal Description
1.1 Switching ch. 1 (LIN) 1.2 Semiconductor-Output C5
1.5 Switching ch. 1(LOUT) 1.6 Semiconductor-Output C6
2.1 Switching ch. 3 (LIN/LOUT) 2.2 Semiconductor-Output C7
2.5 Switching ch. 4 (LIN/LOUT) 2.6 Semiconductor-Output C8
1.3 Dupline signal conductor -
(Dupline-)
1.7 Dupline signal conductor + (Du-
pline+)
1.4 0 VDC operating voltage 1.8 +24 VDC operating voltage
Indicator Description
Green “BUS OK”
LED
Dupline bus:
Off - bus fault / On - bus OK
2 red LED „EIN“ All-or-nothing relay 1/2:
Off - Relay open / On - Relay closed
Min. Typ. Max.
Dupline
Current input 10 µA
Input channels None
Output channels 6 control channels (2 relay / 4 semiconductor
outputs)
Semiconductor outputs
Type PNP transistors, switching to 0 V
Output voltage 21.5 VDC 24 VDC 26.5 VDC
Load capacity (per output) 50 mA
Relay outputs
Type All-or-nothing relay
AC
Voltage 12 VAC 250 VAC
Load capacity (per output) 100 mA 16 A
DC
Voltage 12 VDC 30 VDC
Load capacity (per output) 100 mA 10 A

3931170/02/05/E 7
Doepke
12. Guarantee
All professionally installed, unaltered devices are covered by warranty during the statu-
tory guarantee period from the day of purchase by the end user. The guarantee is not
applicable to damage incurred during transport or caused by short-circuit or overloading.
In the event of defects in workmanship or material, which are discovered within the guar-
antee period, the company will provide a replacement free of charge. The guarantee will
be rendered null and void if the device is opened or tampered with.
Lamp loadsa
Incandescent lamps 3000 W
HV-halogen lamps 2500 W
Fluorescent lamps 2400 W
Fluorescent lamps with el. ballast 600 W
Gas discharge lamps max. 1000 W (70µF), 1250 W (100µFb)
Capacitor for compensation max. 70 µF (100µFb)
Energy-saving lamps, conv.
ballast
1250 W
Energy-saving lamps, el. ballastc300 W
Operating Voltage
Rated operating voltage 21.5 VDC 24 VDC 26.5 VDC
Current input 3 mA 5 mA 8 mA
Ripple voltage 100mVpp
Terminals
Type Strain-relief clamps
Contact area 0.4 mm ∅2.5 mm²
Torque 0.6 Nm
Housing
Type Distribution installation housing to DIN 43880 for
rail-mounting to DIN EN 50022
Dimensions 35 x 85 x 58 (B x H x T in mm) / 2 modules
Material Polycarbonate
General technical data
Ambient temperature -10°C +45°C
Atm. humidity max. 85% (exposure to dew not permissible)
Encl. protection type / standards IEC60669, EN55022 / EN50081-1 and EN55024
/ EN50082-1
Order number, description 09 501 105, Two-way relay output DSM 2
a. The data relate to a minimum service life of 25000 switching cycles and the connection
requirements as per IEC 60069.
b. Min. 5000 switching cycles
c. These data are largely dependent upon the manufacturer. In case of doubt, please refer!
Min. Typ. Max.

8 3931170/02/05/E
Doepke
13. Anschlussschema / Connection Diagram
Sollten Sie Fragen zu diesem Produkt
oder zum Dupline-System haben, wen-
den Sie sich bitte an:
In case of queries concerning this
product or the Dupline system plea-
se contact:
Doepke
Schaltgeräte GmbH & Co. KG
Stellmacherstraße 11
D-26506 Norden, Germany
Tel.: +49 (0) 4931/1806-0
Fax: +49 (0) 4931/1806-101
E-mail:
Internet:
http://www.doepke.de
3931170/02/05/E
1.1
Lin
1.3
D-
1.4
DC-
1.8
DC+
2.4 2.8
1.7
D+
2.3 2.7
1.2
C5
1.6
C6
2.2
C7
2.6
C8
1.5
Lout
2.1
Lin
2.5
Lout
Dupline +
L
N
DSM 2
DSM 2
EIN EIN
Doepke
Dupline
BUS OK
BUS OK
Dupline -
+24 VDC
0V DC
2.6/C8
2.2/C7
1.6/C6
1.2/C5
Table of contents
Languages:
Other Doepke Relay manuals
Popular Relay manuals by other brands

SOUNDLIGHT
SOUNDLIGHT 3212R-H operating manual

Siemens
Siemens 7SR46 Argus Quick reference guide

Mastervolt
Mastervolt Digital AC 1x6A User and installation manual

ABB
ABB ITH Instruction leaflet

Westinghouse
Westinghouse CVE instructions

Schrack Technik
Schrack Technik AMPARO URAU3N11 Assembly and installation instruction