Bustec ProDAQ 3020 USB 2.0 VXIbus Slot-0 User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

USER MANUAL
ProDAQ VXI Data Acquisition Systems
ProDAQ 3020 USB 2.0 VXIbus Slot-0
Interface
PUBLICATION NUMBER: 3020-XX-UM-0201
Copyright, © 2014, Bustec Production, Ltd.
Bustec Production, Ltd.
Bustec House, Shannon Business Park, Shannon, Co. Clare, Ireland
Tel: +353 (0) 61 707100, FAX: +353 (0) 61 707106
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

PROPRIETARY NOTICE
This document and the technical data herein disclosed, are proprietary to Bustec
Production Ltd., and shall not, without express written permission of Bustec
Production Ltd, be used, in whole or in part to solicit quotations from a competitive
source or used for manufacture by anyone other than Bustec Production Ltd. The
information herein has been developed at private expense, and may only be used
for operation and maintenance reference purposes or for purposes of engineering
evaluation and incorporation into technical specifications and other documents,
which specify procurement of products from Bustec Production Ltd.. This
document is subject to change without further notification. Bustec Production Ltd.
Reserve the right to change both the hardware and software described herein.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 3 of 60
Table of Contents
1. INTRODUCTION..........................................................................................................7
1.1 Requirements........................................................................................................7
1.1.1 The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface.........................................7
1.1.2 The Host Computer...........................................................................................7
1.1.3 The VXI Mainframe...........................................................................................8
1.1.4 The USB Cable.................................................................................................8
2. INSTALLATION AND CONFIGURATION ...................................................................9
2.1 Unpacking and Inspection .....................................................................................9
2.2 Installing the VISA Library ...................................................................................10
2.3 Installing the ProDAQ 3020 Interface ..................................................................12
2.4 Installing the ProDAQ 3020 USB Driver ..............................................................15
2.5 Configuring the ProDAQ 3020 for the VISA Library.............................................17
2.6 Configuring the ProDAQ 3020 Interface Characteristics .....................................19
2.6.1 Configuring the VXIbus Access.......................................................................20
2.6.2 Configuring the Interrupt Lines........................................................................21
2.6.3 Configuring the Front Panel I/O.......................................................................21
2.6.4 Firmware Version Checking and Update.........................................................23
2.7 Verifying the Installation ......................................................................................25
2.7.1 Running the VXIbus Resource Manager.........................................................25
2.7.2 The VISA Assistant.........................................................................................27
3. PROGRAMMING VXI DEVICES USING THE PRODAQ 3020 INTERFACE.............33
3.1 Connecting to a Device .......................................................................................33
3.2 Programming Register-based Devices................................................................34
3.2.1 Accessing Registers........................................................................................34
3.2.2 Moving Blocks of Data ....................................................................................37
3.3 Programming Message-based Devices...............................................................40
3.3.1 Writing and Reading Messages ......................................................................40
3.4 Optimising Programs using the ProDAQ 3020 Interface .....................................41
3.5 Using VXIbus and Front Panel Trigger Lines.......................................................42
3.5.1 Using VXIbus Trigger Lines.............................................................................42
3.5.2 Using Front-Panel Trigger Lines .....................................................................43
4. PROGRAMMING GPIB DEVICES USING THE PRODAQ 3020 INTERFACE..........45
4.1 Connecting to a Device .......................................................................................45
4.2 Reading and Writing Messages to/from a GPIB Device ......................................46
5. VXIBUS CONFIGURATION REGISTER DETAILS....................................................47
5.1 Address Map .......................................................................................................47
5.2 Register Description............................................................................................47
5.2.1 ID Register......................................................................................................47
5.2.2 Logical Address Register ................................................................................47
5.2.3 Device Type....................................................................................................48
5.2.4 Status Register................................................................................................48
5.2.5 Control Register..............................................................................................49
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 4 of 60 Copyright, © 2003 Bustec Production Ltd.
5.2.6 MODID Register..............................................................................................49
6. FRONT PANEL CONNECTORS AND SWITCHES...................................................51
6.1 ProDAQ 3020-AA Front Panel Connectors and Switches...................................51
6.1.1 USB Connector...............................................................................................51
6.1.2 Clk In/Out Connectors.....................................................................................51
6.1.3 Trigger In/Out Connectors...............................................................................51
6.1.4 Reset Switch...................................................................................................51
6.2 ProDAQ 3020-AB Front Panel Connectors and Switches...................................52
6.2.1 GPIB Port Connector .......................................................................................52
6.3 ProDAQ 3020-BA Front Panel Connectors and Switches...................................53
6.3.1 Trigger Chain In/Out Connectors.....................................................................53
6.4 ProDAQ 3020-BB Front Panel Connectors and Switches...................................54
SPECIFICATIONS.............................................................................................................55
6.5 Interface Characteristics......................................................................................55
6.6 VXIbus Characteristics........................................................................................55
6.7 Front Panel I/O....................................................................................................56
6.8 Power Supply Loading.........................................................................................57
6.9 Miscellaneous......................................................................................................58
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 5 of 60
Table of Figures
Figure 1 - Selecting the Type of Installation.......................................................................11
Figure 2 - Selecting Components for Installation...............................................................11
Figure 3 - Installing the ProDAQ 3020 into a C-Size Mainframe........................................12
Figure 4 - A-to-B Type USB Cable.....................................................................................12
Figure 5 - USB Configurations...........................................................................................13
Figure 6 - USB Bus Topology............................................................................................14
Figure 7 - Using the Hardware Wizard..............................................................................15
Figure 8 - Select a Search Location..................................................................................15
Figure 9 - Typical Device Manager Display .......................................................................16
Figure 10 - VISA Library Configuration Utility ....................................................................17
Figure 11 - Adding an Interface .........................................................................................18
Figure 12 –Displaying configured Interfaces.....................................................................18
Figure 13 - The ProDAQ 3020 Configuration Dialog..........................................................19
Figure 14 - New firmware available message....................................................................20
Figure 15 - Configuring the Interrupt Lines .......................................................................21
Figure 16 - Configuring the Front Panel I/O.......................................................................22
Figure 17 - Firmware Version and Update.........................................................................23
Figure 18 - Firmware Update Progress..............................................................................24
Figure 19 - Running the VXI Resource Manager...............................................................25
Figure 20 - Resource Manager Configuration...................................................................26
Figure 21 - The VISA Assistant..........................................................................................27
Figure 22 - VISA Assistant Session Window .....................................................................27
Figure 23 - Using a template operation..............................................................................28
Figure 24 - Using a basic I/O operation .............................................................................29
Figure 25 - Memory I/O Operations...................................................................................29
Figure 26 - Shared Memory Operations.............................................................................30
Figure 27 - VXI Specific Operations...................................................................................31
Figure 28 - Opening a VISA Session.................................................................................33
Figure 29 - Memory-based I/O...........................................................................................35
Figure 30 - Register I/O using memory mapping...............................................................36
Figure 31 - Moving a Block of Data....................................................................................37
Figure 32 - VXIbus transfer types......................................................................................38
Figure 33 - Performing VXIbus Block Transfers.................................................................39
Figure 34 - Reading the Device Identification....................................................................40
Figure 35 - Sending a Trigger Pulse..................................................................................42
Figure 36 - Mapping Trigger Lines.....................................................................................44
Figure 37 –Reading and writing messages to/from a GPIB device...................................46
Figure 38 - USB Connector Pin-out...................................................................................51
Figure 39 - GPIB Port Connector Pin-out...........................................................................52
Figure 40 - Trigger Chain Connectors Pin-out...................................................................53
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 6 of 60 Copyright, © 2003 Bustec Production Ltd.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 7 of 60
1. Introduction
The USB is a high-speed cable bus that supports data exchange between a host computer
and a wide range of simultaneously accessible peripherals. The ProDAQ 3020 USB 2.0
VXIbus Slot-0 Interface provides a direct link between the USB and the VXI backplane.
This manual describes the implementation, configuration and use of the interface.
1.1 Requirements
To set up and use the ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface, you need the
following:
A PC compatible computer running Windows 2000®or Windows XP®
A USB 1.1 or USB 2.0 compatible host controller
A VXI mainframe
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface
USB cable
ProDAQ Driver CD
1.1.1 The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface is a C-size, register based VXIbus
module providing a direct link between the high-speed USB 2.0 bus and the VXI
backplane. Data packages sent and received via the USB bus will be either translated into
accesses on the VXIbus or can be used to control the configuration and Slot-0 capabilities
of the ProDAQ 3020. The ProDAQ 3020 can automatically detect whether it is installed in
the left most slot of a VXI mainframe (slot “0”) and will enable or disable its Slot-0
capabilities accordingly.
1.1.2 The Host Computer
The ProDAQ 3020 Interface together with the USB controller allows your host computer to
perform as if it is plugged directly into the VXI backplane. It needs to be equipped with a
USB 1.1 or USB 2.0 compatible host controller, either already build-in into the
motherboard or via expansion cards. The drivers and software provided are for Pentium
based PC compatible computers.
Note
The host controller need to be already installed into and recognized by your
system. Bustec Production Inc. does not provide drivers for any USB component
other then the ProDAQ 3020 Interface itself. Please contact the manufacturer of
your motherboard or expansion card for suitable USB drivers for your operating
system.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 8 of 60 Copyright, © 2003 Bustec Production Ltd.
Note
USB 1.0 compatible host controllers are not supported. USB 1.1 compatible host
controllers are limited to a maximum bus speed of 12 Mb/s. To achieve full
performance with the ProDAQ 3020 Interface, a USB 2.0 host controller is required.
1.1.3 The VXI Mainframe
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface is a single-slot wide, C-size VXI
module, which can reside in any slot of a C-size or D-size VXI mainframe. It will
automatically detect whether it is located in the left most slot of the mainframe (slot “0”)
and will enable or disable its Slot-0 capabilities accordingly, avoiding conflicts with the
backplane and other modules.
Note
Being a C-size module, the ProDAQ 3020 does not provide a P3 connector as used
in D-size mainframes. If used as a slot-0 controller in a D-size mainframe, it cannot
provide the necessary control for instruments using the additional features of the
P3 connector (CLK100, Star Trigger, add. Trigger and Local Bus Lines).
1.1.4 The USB Cable
To connect the ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface to your host computer, use
the USB A-to-B high-/full-speed cable provided. You can connect the ProDAQ 3020 to any
of the USB ports your host computer/expansion board provides. Alternatively, if you are
using a USB hub to connect several USB devices to your computer, you may connect the
ProDAQ 3020 to a port on the hub.
Note
If you are using an additional USB hub to connect the ProDAQ 3020 to your
computer, the hub must be USB 1.1 or 2.0 compatible. To achieve full performance,
the hub must be able to support the high-speed mode as specified by the USB 2.0
standard. In general, using multiple devices connected to the same host controller
port may decrease the performance of your system.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 9 of 60
2. Installation and Configuration
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface is a single slot, C-size VXIbus
instrument and can be installed in any slot of a standard C-size VXI mainframe. To be
Slot-0 controller for the VXIbus system, it must be installed in the leftmost slot of the VXI
mainframe (slot “0“). If it is installed in any other slot of a VXI mainframe, all slot-0
capabilities (MODID, CLK10, etc.) will be automatically turned off.
Note:
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface does not extend the VXI
backplane between mainframes in a multi-mainframe system. This means that
devices sharing the local bus must be installed in the same mainframe.
To install the ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface and the necessary software
on your system, use the installation sequence as described in this chapter:
Step 1: Unpacking and Inspection
Step 2: Installing the VISA Library
Step 3: Installing the ProDAQ 3020 Interface
Step 4: Installing the ProDAQ 3020 USB Driver
2.1 Unpacking and Inspection
All ProDAQ modules are shipped in an antistatic package to prevent any damage from
electrostatic discharge (ESD). Proper ESD handling procedures must always be used
when packing, unpacking or installing any ProDAQ module, ProDAQ plug-in module or
ProDAQ function card:
Ground yourself via a grounding strap or similar, e.g. by holding to a grounded
object.
Remove the ProDAQ module from its carton, preserving the factory packaging
as much as possible.
Discharge the package by touching it to a grounded object, e.g. a metal part of
your VXIbus chassis, before removing the module from the package.
Inspect the ProDAQ module for any defect or damage. Immediately notify the
carrier if any damage is apparent.
Only remove the module from its antistatic bag if you intend to install it into a VXI
mainframe or similar.
When reshipping the module, use the original packing material whenever possible. The
original shipping carton and the instrument’s plastic foam will provide the necessary
support for safe reshipment. If the original anti-static packing material is unavailable, wrap
the ProDAQ module in anti-static plastic sheeting and use plastic spray foam to surround
and protect the instrument.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 10 of 60 Copyright, © 2003 Bustec Production Ltd.
2.2 Installing the VISA Library
The VISA library provided by Bustec Production Ltd is used to communicate to the VXI
instruments in mainframes connected via the ProDAQ 3020 USB 2.0 VXIbus Slot-0
Interface to the host PC.
Note
On Microsoft Windows 2000® or Microsoft Windows XP® systems it is
recommended to install the VISA library and the USB driver from an account having
administrator privileges.
To install it on your PC, do the following:
1. Apply power to your PC and boot your operating system. Close all open
applications to allow for a safe installation of the new components.
Do not apply power to the VXI mainframe at this point in time, or, do not
connect the ProDAQ 3020 Interface via the USB bus to your PC !
2. Insert the driver CD provided with the module into your PC CD-ROM drive. If the
autorun feature is turned on, the CD menu will start automatically. If not, select
“Run” from your Start menu and type <drive>:autorun.exe, where <drive>
designates the CD-ROM drive with the driver CD in it.
3. Select “VISA Library for ProDAQ Controller” from the driver section of the CD menu
to start the setup wizard.
Please note: If you have downloaded the Bustec VISA Library from our WEB site,
all files are packed into a single ZIP archive. To start the installation, unpack the
files into a separate directory on your drive and run the executable “setup.exe” from
that location.
4. Select “Next” to review the license agreement for the Bustec VISA library. You will
need to accept the terms of the agreement by selecting “Yes” to be able to install
the Visa library.
5. Select the folder where the wizard will install the components of the VISA library.
Please note that the location chosen will be the top-level directory for a
VXIplug&play standard compliant directory tree, and not a single location for the
library only. If you install VXIplug&play driver on your PC, they will install using the
directory tree created by the VISA installation.
6. Select “Next” to choose the type of setup to perform (see Figure 1). “Typical” will
install the most common components, while “Compact” will only install the absolute
necessary components. To choose which components to install, choose “Custom”.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 11 of 60
Figure 1 - Selecting the Type of Installation.
7. If you have chosen “Custom”, selecting “Next” will allow you to select the
components to install (see Figure 2):
VISA Library The core files (hardware driver, VISA dynamic link library,
config utility, include files) of the installation.
VISA Assistant An interactive graphical user interface for the VISA library. It
will allow you to use the VISA library without writing your own
application.
Help Files Help files for the VISA library.
Examples How to program using the VISA library.
Figure 2 - Selecting Components for Installation.
8. After selecting “Next”, the wizard will install the files and components for the chosen
configuration on your system.
9. Re-start the computer after the installation is complete.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 12 of 60 Copyright, © 2003 Bustec Production Ltd.
2.3 Installing the ProDAQ 3020 Interface
To prevent damage to the ProDAQ module being installed, it is recommended to remove
the power from the mainframe or to switch it off before installing.
Insert the module into the mainframe using the guiding rails inside the mainframe as
shown in Figure 3. Push the module slowly into the slot until the modules backplane
connectors seat firmly in the corresponding backplane connectors. The top and bottom of
the front panel of the module should touch the mounting rails in the mainframe.
Figure 3 - Installing the ProDAQ 3020 into a C-Size Mainframe
Note:
To ensure proper grounding of the module, tighten the front panel mounting
screws after installing the module in the mainframe.
To connect the ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface to your computer, use the
USB A-to-B cable provided. The “A” series plug connects to your host PC or hub, while the
“B” series plug plugs into the “B” series receptacle on the ProDAQ 3020 front panel.
Figure 4 - A-to-B Type USB Cable
Slide the module into the
mainframe using the
guiding rails until its
connectors plug into the
backplane connectors.
Front panel
mounting
screws
“A” Plug
“B” Plug
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 13 of 60
You can connect the ProDAQ 3020 directly to your host controller. If you want to use
multiple 3020 or other USB devices in your system, you can use multiple free host ports
or, if necessary, a USB hub:
Figure 5 - USB Configurations
The USB physical interconnect is a tiered star topology with a hub at the center of each
star. Therefore new devices can be added either on the same tier, as long as ports are
available, or one of the ports can be used to connect to a new hub, providing the center for
a new tier. The USB standard allows for up to seven tiers per system.
VXI
VXI
VXI
VXI VXI VXI
USB Hub
DIRECT CONNECTION
DIRECT CONNECTION
USING MULTIPLE
HOST PORTS
CONNECTING MULTIPLE
INTERFACES USING
A USB HUB
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 14 of 60 Copyright, © 2003 Bustec Production Ltd.
The center of the first tier is always the controller/hub in the computer. This means that up
to five levels of USB hubs can be added. The last tier (tier seven) does only allow
functions (devices) in it.
Figure 6 - USB Bus Topology
USB 2.0 host controllers and hubs provide capabilities so that full-speed and low-speed
data can be transmitted at high-speed between the host controller and the hub, but
transmitted between the hub and the device at full-speed or low-speed. This capability
minimizes the impact that full-speed and low-speed devices have upon the bandwidth
available for high-speed devices.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 15 of 60
2.4 Installing the ProDAQ 3020 USB Driver
After re-starting your computer, turn on the VXI mainframe and/or connect the ProDAQ
3020 USB 2.0 VXIbus Slot-0 Interface via the USB bus to the PC. Because the USB bus is
hot-plug capable, the system will detect the event and will start to look for a driver for the
new hardware.
In the “New Hardware Wizard”, select “Search for a suitable driver for my device”:
Figure 7 - Using the Hardware Wizard.
and select “Next”. If you are installing using the supplied CD-ROM, choose “CD-ROM
drives as optional search location:
Figure 8 - Select a Search Location.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 16 of 60 Copyright, © 2003 Bustec Production Ltd.
If you have downloaded the VISA library from our WEB site, choose “Specify a location”
and specify the location of the directory containing the unpacked installation in the next
step.
Continue through the installation process as directed by the “New Hardware Wizard”. It will
show you the location of the driver files found and allow you to select “Finish” to complete
the installation.
After the driver is installed, the ProDAQ 3020 USB 2.0 VXIbus Slot-0 interface will be
shown in the device manager under “Bustec VXI Devices” once it is connected and
switched on:
Figure 9 - Typical Device Manager Display
Attention:
The VISA configuration utility must be run whenever a new ProDAQ 3020 Interface
is connected to the host PC.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 17 of 60
2.5 Configuring the ProDAQ 3020 for the VISA Library
The VISA library uses interface names and numbers to access available hardware
interfaces. In order to enable the VISA library to use a ProDAQ 3020 interface, which is
connected to a host PC for the first time, a valid interface name and number must be
assigned to this device. The assigned interface name and number will be stored internally
in the configuration for this ProDAQ 3020 interface together with its serial number and will
be used for this device whenever it is connected to this host.
To assign an interface name/number and configure the ProDAQ 3020, connect the USB
interface cable between one USB port of the host PC and the USB port on the ProDAQ
3020 front panel and turn on the VXI mainframe.
From the VXIplug&play program group created during the installation of the VISA library,
select “VISA Configuration Utility” (“Start” “VXIPNP” “VISA Configuration Utility”).
This will start the configuration tool for the VISA library and attached hardware interfaces.
Figure 10 - VISA Library Configuration Utility
To add a new interface, select “Add Interfaces”. A new dialog “Available Interfaces” is
shown with a list of unconfigured devices found in the system. ProDAQ 3020 interfaces
appear as interfaces of the type “VXI” together with a description containing the serial
number of the device (see Figure 11, ProDAQ 3020 Ser. No. 3201003). If the 3020
detected features the optional on-board GPIB interface (ProDAQ 3020-AB and ProDAQ
3020-BB only), the GPIB interface will appear in the list of available interfaces as a
separate interface of the type “GPIB”, again with a description containing the serial number
of the device (see Figure 11, ProDAQ 3020 Ser.No. 30201018).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

3020-XX-UM ProDAQ 3020 USB2.0 VXIbus Slot-0 Interface User Manual
Page 18 of 60 Copyright, © 2003 Bustec Production Ltd.
Figure 11 - Adding an Interface
To configure and add a ProDAQ 3020 interface, select the entry for the device in the list,
choose an interface number on the right side and select ‘OK’. The list of configured
interfaces in the main dialog will now display the configured interface with its interface
name and number:
Figure 12 –Displaying configured Interfaces
To remove the configuration for a device from the system, select the device in the list of
configured interfaces and select “Remove Interface”. To configure device-dependent
parameters of an interface, select “Configure Interface”. If you hot-plug a device which was
already configured on this system, the “Refresh List” button can be used to update the list
of configured interfaces.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

ProDAQ 3020 USB 2.0 VXIbus Slot-0 Interface User Manual 3020-XX-UM
Copyright, © 2003 Bustec Production Ltd. Page 19 of 60
2.6 Configuring the ProDAQ 3020 Interface Characteristics
The ProDAQ 3020 USB 2.0 VXIbus Slot-0 interface has a number of characteristics that
can be configured with the configuration utility. The settings are stored together with the
device name/number and the serial number on the host system and applied whenever the
device is connected to the host system and the resource manager is executed.
To configure the ProDAQ 3020, select the device you want to configure in the list and
select “Configure Interface”. The four tab panels of the configuration dialog allow to
configure the different parts of the interface:
VXIbus Configures various parameters used by the ProDAQ 3020
when accessing the VXIbus.
Interrupt Configures the assignment and use of the VXIbus interrupt
lines.
Front Panel I/O Configures the routing of VXIbus clock and trigger lines
to/from the front panel connectors.
Version Allows checking and updating the firmware version of the
attached ProDAQ 3020.
Figure 13 - The ProDAQ 3020 Configuration Dialog
To store the altered configuration, select “OK”. “Cancel” closes the dialog without altering
the stored configuration.
NOTE
To apply changes to the configuration of the 3020, you will need to re-run the
resource manager or to restart your VXI mainframe to make these changes
effective.
.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com