Battery backup enable/disable (Link PLK2) Available on NC942B controllers only
Link PLK2 enables or disables the call controller’s 500mAHr rechargeable battery
backup facility. Note that this facility is available on NC942B call controllers only.
When enabled (link PLK2 fitted), the NC942B’s onboard battery backup supply
will continue to power the system for approximately 24 hours (standby) plus 15
minutes (alarm running time) in the event of a mains failure. This will be indicated by the
controller’s ‘ON’ LED flashing green approximately once per second.
Should the mains supply remain disconnected for a prolonged period of time, the battery
backup facility will automatically shutdown to prevent the batteries from deep discharge.
The default setting for Link PLK2 is link not fitted/battery disabled. This is to conserve bat-
tery life and ensure the safety of the controller during storage/transit. Note that the shorting
link required to enable the facility is provided in the controller’s accessory pack.
Sounder and LED test facility
Pressing the controller’s RESET button when link PLK1 is fitted in the Reset (a) position will
make its sounder and alarm LED activate. When released, the LED and sounder will switch off.
BASIC OPERATION
The green power 'ON' indicator indicates that the call controller is powered up.
When a standard call is triggered at any device connected to the controller (see figure 1), the
controller’s sounder will generate a constant tone and its red 'CALLING' LED will illuminate.
The call controller’s relay will also activate and any external equipment connected to the
controller’s relay contacts (see page 3) will operate as configured.
Depending on how Link PLK1 has been configured (see page 3), pressing the controller’s
'RESET' button will (a) reset the call (b) mute the call or (c) have no effect. (Note that standard
calls can also be cancelled at the device that originated the call if it has a reset facility or via
a remote reset point).
If an emergency call is triggered on a device connected to the controller, the call controller’s
sounder will pulse and its red 'CALLING' LED will flash. The controller’s relay will also pulse
and any external equipment connected to the controller’s relay contacts (see page 3) will
operate as configured. Note that emergency calls override standard calls and can only be
reset at the device from which they were generated.
TECHNICAL SPECIFICATION
Mains supply: Voltage: 230V a.c.; Max current: 23mA; Frequency: 50Hz.
Output: Voltage: 12V d.c.; Current: 140mA;
Volt-free relay contacts (NO/C/NC) rated at 30V d.c. @ 1A
Indicators: Red alarm present LED; Green supply present LED (flashes green on
NC942B model only when battery back up is active)
Sounder: Active in alarm.
Controls: ‘RESET’ Button (link selectable for reset, mute or no function).
IP Rating: IP31 when correctly installed.
Dimensions: 147 x 87 x 39mm (WxHxD). Mounts on 25mm UK double gang back box.
Fit!to
Enable
battery
PLK2
GENERAL
The NC942 is a one zone call controller with a built-in mains to regulated 12V d.c. 140mA
power supply. Its features include a volume adjustable sounder, a link-selectable mute/reset
button, a Power ‘ON’ LED, an Alarm ‘CALLING’ LED and a volt-free relay output (for optional
interfacing to externally powered beacons, strobes or other ancillary devices). It also features
a Braille text label for ease of use by the visually impaired.
The NC942B call controller includes all of the above plus an additional on-board rechargeable
battery backup facility providing up to 24 hours standby and 15 minutes alarm running time.
Both controllers are fully compatible with our entire range of 800 Series Call System
components, making them ideal for virtually all single zone applications including disabled
persons toilet alarms.
One Zone
Call Controller
I N S T A L L A T I ON I N S T R U C T I O N S
Approved Document No: DNU0942000 Rev 1 • Page 1 of 4
This equipment must be installed and maintained by a suitably skilled
and technically competent person.
This Call Controller is a piece of Class 2 equipment. However, any metal parts used during
installation (i.e. metal back box) MUST be earthed. The earth termination point on the One
Zone Call Controller is provided for installer convenience only and, as such, should only be
used if an earth connection is not required elsewhere.
!
N C 9 4 2 / N C 9 4 2 B

Many authorities insist that a call system’s reset function is carried out at ‘point of source’
(i.e. in the room in which the call was made). This is to ensure that the person who raised
the alarm is visited. As such, the default setting for Link PLK1 is link not fitted/no effect.
ENGINEER SELECTABLE FUNCTIONS
Figure 2 : Rear view of the NC942/NC942B Call Controller
(a) Reset the system
In this position, pressing the controller’s RESET button when a standard call is
active will return the controller to its normal state.
(b) Mute the system
In this position, pressing the controller’s RESET button when a standard call is
active will mute the controller’s on-board sounder.
(c) Have no effect
In this position (no link fitted), pressing the controller’s RESET button when a
standard call is active will have no effect.
Volume control (Potentiometer VR1)
Potentiometer VR1 can be used to adjust the level of the call controller’s on-board
sounder. Turning the control clockwise with a terminal screwdriver will increase
the volume, turning it anti-clockwise will decrease it.
On-board volt-free relay operation (RLY1)
The call controller includes an on-board volt-free relay with normally open (NO),
normally closed (NC) and common (C) contacts. The relay contacts are rated at
30Vd.c. @ 1A and can be used to switch optional externally powered devices such
as sounders, strobes or the extra low voltage coils of mains controlling relays.
When no calls are on the system, the normally closed contact is made. When an alarm signal
is present, the relay switches and the normally open contact is made. Muting the system will
have no effect on the relay’s operation.
Reset button operation (Link PLK1)
Link PLK1 allows the call controller’s on-board RESET button to be set up to:-
L
N
PLK1
Reset Mute Volume
+VE
SIGNAL
-VE
NO
C
NC
RECHARGEABLE
BATTERY BACKUP
SUPPLY COVER
NC942B
MODEL ONLY
Fit to
Enable
battery
PLK2
CONN3
CONN2 VR1
RLY1
Reset!!!!!!!!!!!!!!!Mute
Reset!!!!!!!!!!!!!!!Mute
Reset!!!!!!!!!!!!!!!Mute
(no!link!fitted)
!
Volume
Approved Document No: DNU0942000 Rev 1 • Page 3 of 4
Approved Document No: DNU0942000 Rev 1 • Page 2 of 4
INSTALLATION
ALWAYS ENSURE THE MAINS SUPPLY IS ISOLATED BEFORE MAKING ANY CONNECTIONS.
The call controller should be sited internally on a standard UK double gang back box (minimum
depth 25mm) in an area where it is readily accessible by the person(s) designated to use it. The
area should be clean and dry and the ambient light and sound levels should allow the status of
the indicators and internal sounder to be seen and heard. Any likelihood of tampering or
vandalism should also be taken into account.
Figure 1 : Example NC942/NC942B Call Controller Wiring
Mains wiring
The general requirement for the mains supply to the call controller is fixed wiring, using three
core cable of not less than 1mm2. This should be fed from an isolating switched fused spur,
fused at 3A, which is marked appropriately and secure from unauthorised operation.
Live and neutral should be connected to the controller’s L and N terminals
respectively. If a plastic back box is used, make the earth connection to the
terminal marked at connector block CONN2. If a metal back box is used,
the earth connection must be made to back box’s earth bonding point.
All external wiring brought into the unit must be adequately insulated with
PVC or Neoprene.
All mains wiring should be provided in accordance with the current edition of the IEE Wiring
Regs (BS 7671) or in accordance with the relevant national wiring rules.
Extra low voltage (ELV) wiring
Four core stranded burglar alarm cable is ideal for the extra low voltage wiring on most installations.
All extra low voltage wiring must be carefully planned before starting the job. Always segregate
extra low voltage wiring from the mains wiring.
In the event of a short circuit on the extra low voltage wiring, an internal self-resetting fuse will
temporarily isolate the system until the fault is cleared. The Call Controller is also protected by a
non-serviceable thermal fuse in its transformer winding which will blow if there is a serious
malfunction. If this happens, return the controller for repair.
L
N
CONN2
A maximum of five 800 Series devices (ceiling pulls, call points, overdoor lights,
reset points, etc.), can typically be connected to the call controller. Always refer
to the installation instructions supplied with each device before installation
NO
C
NC
CONN3
-Ve SIG +Ve 1 -Ve +Ve Spr Sig -Ve Sig -Ve +Ve Sig -Ve +Ve
NC C NO
NEGATIVE
SIGNAL
POSITIVE
RESET
Call
CALLING
F
U
S
E
ON
Call
RESET
Call
ALERT
RESET
CALL
NC942/NC942B
Call Controller
NC806CS Overdoor
Light c/w Sounder
NC807C
Ceiling Pull
NC809DBB Reset
Point c/w Sounder
NC802DEB-1/2
Emergency Call Point
1mm2
T&E
Three cores of four
core stranded burglar
alarm cable
3A Switch
Fused Spur
This manual suits for next models
2
Other C-TEC Controllers manuals
Popular Controllers manuals by other brands

Nordson
Nordson Sure Coat Operator card

PCB Piezotronics
PCB Piezotronics IMI SENSORS 683A101000 Installation and operating manual

AUTOFLAME
AUTOFLAME Mk8 MM Installation and commissioning guide

ELREHA
ELREHA TKP 3130/1 Technical manual

Mitsubishi Electric
Mitsubishi Electric MELSEC-L Series LD40PD01 user manual

Renesas
Renesas RZ/T2M Startup guide