catec ZOGLAB HG6000 User manual

ZOGLAB
EN
HG6000 Humidity Generator User Manual
Turfschipper 114 | 2292 JB Wateringen | Tel. +31 (0)174 272330 | www.catec.nl | info@catec.nlTurfschipper 114 | 2292 JB Wateringen | Tel. +31 (0)174 272330 | www.catec.nl | info@catec.nl
MEETINSTRUMENTATIE

The content marked by this symbol contains warning information, please read it carefully to prevent instrument damage or data loss.
The content marked by this symbol involves functional details, please read it carefully before using the instrument.
Limited Warranty And Limited Liability
We guarantee that ZOGLAB products will be free of defects in materials and workmanship within one year from the date of purchase. This warranty does not cover fuses,
disposable batteries, or products damages from accident, negligence, misuse, or abnormal use or handling. ZOGLAB has not authorized any distributor to extend the
warranty period. If repairs are required during the warranty period, please send the product to the distributor where you purchased with a fault description.
This guarantee is your only compensation. Except this guarantee, ZOGLAB does not make any express or implied guarantees (such as guaranteeing the suitability for a
particular purpose). At the same time, ZOGLAB will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by any reason or
speculation. Since some regions or countries do not allow limitations on implied warranties and incidental or consequential damages, the above-mentioned scope of
liability and regulations may not be relevant to you.
Special statement: This document is a supporting manual for HG6000. Due to product upgrades or other reasons, if the pictures, mechanical dimensions, and etc. in the
document are different from the actual product, please refer to the actual product. Without the written permission of ZOGLAB, any content of this document shall not be
copied or disseminated in any form or in any way, including electronic and mechanical means, for any purpose. The company reserves the right of final interpretation.
Annotation
are registered trademarks of ZOGLAB Microsystem Co.,Ltd. Any other company or individual is strictly prohibited
from copying and disseminating in any form without written permission.
For more information,please visit our website http://www.zoglab.cn
All rights reserved,unauthorized copy not allowed. 2002-2022 All Rights Reserved Zoglab Microsystems Co., Ltd.
ZOGLAB and HG6000
TM TM

The content marked by this symbol contains warning information, please read it carefully to prevent instrument damage or data loss.
The content marked by this symbol involves functional details, please read it carefully before using the instrument.
Limited Warranty And Limited Liability
We guarantee that ZOGLAB products will be free of defects in materials and workmanship within one year from the date of purchase. This warranty does not cover fuses,
disposable batteries, or products damages from accident, negligence, misuse, or abnormal use or handling. ZOGLAB has not authorized any distributor to extend the
warranty period. If repairs are required during the warranty period, please send the product to the distributor where you purchased with a fault description.
This guarantee is your only compensation. Except this guarantee, ZOGLAB does not make any express or implied guarantees (such as guaranteeing the suitability for a
particular purpose). At the same time, ZOGLAB will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by any reason or
speculation. Since some regions or countries do not allow limitations on implied warranties and incidental or consequential damages, the above-mentioned scope of
liability and regulations may not be relevant to you.
Special statement: This document is a supporting manual for HG6000. Due to product upgrades or other reasons, if the pictures, mechanical dimensions, and etc. in the
document are different from the actual product, please refer to the actual product. Without the written permission of ZOGLAB, any content of this document shall not be
copied or disseminated in any form or in any way, including electronic and mechanical means, for any purpose. The company reserves the right of final interpretation.
Annotation
are registered trademarks of ZOGLAB Microsystem Co.,Ltd. Any other company or individual is strictly prohibited
from copying and disseminating in any form without written permission.
For more information,please visit our website http://www.zoglab.cn
All rights reserved,unauthorized copy not allowed. 2002-2022 All Rights Reserved Zoglab Microsystems Co., Ltd.
ZOGLAB and HG6000
TM TM

CHAPTER 1 Safe Usage Instruction
Safe Usage Instruction
CHAPTER 2 HG6000 Product Introduction
----------------------------------------------------------- 2
------------------------------------------------------------------ 5
-------------------------------------------- 6
---------------------------------------------------------------------- 6
------------------------------------------------------------- 7
---------------------------------------------- 7
--------------------------------------------------------------- 8
------------------------------------------------------------- 9
-------------------------------------------- 10
------------------------------------------------------------- 10
---------------------------------------------- 11
-------------------------------------- 12
-------------------------------------- 13
About HG6000
Structure view and function description
Front view
Function description
Interface definition of test instrument
Rear and side view
Function description
Display icon and function description
Main interface icon
Main interface function description
Humidity measurement icon and description
Measurement function icon and description
Contents

CHAPTER 1 Safe Usage Instruction
Safe Usage Instruction
CHAPTER 2 HG6000 Product Introduction
----------------------------------------------------------- 2
------------------------------------------------------------------ 5
-------------------------------------------- 6
---------------------------------------------------------------------- 6
------------------------------------------------------------- 7
---------------------------------------------- 7
--------------------------------------------------------------- 8
------------------------------------------------------------- 9
-------------------------------------------- 10
------------------------------------------------------------- 10
---------------------------------------------- 11
-------------------------------------- 12
-------------------------------------- 13
About HG6000
Structure view and function description
Front view
Function description
Interface definition of test instrument
Rear and side view
Function description
Display icon and function description
Main interface icon
Main interface function description
Humidity measurement icon and description
Measurement function icon and description
Contents

CHAPTER5 HG6000 Product Information
-------------------------------------------------------------- 31
---------------------------------------------------------------- 32
---------------------------------------------------------------- 33
------------------------------------------------------------------ 34
-------------------------------------------------------------- 35
----------------------------------------------------------------- 36
-------------------------------------------------------------- 37
------------------------------------------------------------ 38
---------------------------------------------------------------- 39
-------------------------------------------------------------------------- 40
CHAPTER6 Service
Calibration setting
Control setting
Store recording
Time setting
Brightness setting
Sound setting
Language setting
System information
System update
Help
Warranty ---------------------------------------------------------------------- 49
Value setting numeric soft keyboard icon
Status/setting interface icon
Connect power supply
Connect external expansion test cabin interface
Add/Drain water
Add desiccant
Power on/off
Insert the humidity probe
Set temperature
Operating
Programming
Test probe measurement
CHAPTER 3 Operation and Usage
CHAPTER 4 System Settings
System setting interface
Network setting
COM setting
----------------------------------------- 14
---------------------------------------------------- 16
----------------------------------------------------------- 17
---------------------------------- 18
--------------------------------------------------------------- 19
------------------------------------------------------------------ 20
------------------------------------------------------------------ 21
-------------------------------------------------------- 22
--------------------------------------------------------------- 23
--------------------------------------------------------------------- 24
------------------------------------------------------------------ 25
------------------------------------------------------- 26
--------------------------------------------------------- 28
---------------------------------------------------------------- 29
------------------------------------------------------------------- 30
--------------------------------------------------------- 42
------------------------------------------------------------ 44
-------------------------------------------------------------------- 45
------------------------------------------------------------ 47
Technical specification
Product dimensions
Packing list
Quality certification

CHAPTER5 HG6000 Product Information
-------------------------------------------------------------- 31
---------------------------------------------------------------- 32
---------------------------------------------------------------- 33
------------------------------------------------------------------ 34
-------------------------------------------------------------- 35
----------------------------------------------------------------- 36
-------------------------------------------------------------- 37
------------------------------------------------------------ 38
---------------------------------------------------------------- 39
-------------------------------------------------------------------------- 40
CHAPTER6 Service
Calibration setting
Control setting
Store recording
Time setting
Brightness setting
Sound setting
Language setting
System information
System update
Help
Warranty ---------------------------------------------------------------------- 49
Value setting numeric soft keyboard icon
Status/setting interface icon
Connect power supply
Connect external expansion test cabin interface
Add/Drain water
Add desiccant
Power on/off
Insert the humidity probe
Set temperature
Operating
Programming
Test probe measurement
CHAPTER 3 Operation and Usage
CHAPTER 4 System Settings
System setting interface
Network setting
COM setting
----------------------------------------- 14
---------------------------------------------------- 16
----------------------------------------------------------- 17
---------------------------------- 18
--------------------------------------------------------------- 19
------------------------------------------------------------------ 20
------------------------------------------------------------------ 21
-------------------------------------------------------- 22
--------------------------------------------------------------- 23
--------------------------------------------------------------------- 24
------------------------------------------------------------------ 25
------------------------------------------------------- 26
--------------------------------------------------------- 28
---------------------------------------------------------------- 29
------------------------------------------------------------------- 30
--------------------------------------------------------- 42
------------------------------------------------------------ 44
-------------------------------------------------------------------- 45
------------------------------------------------------------ 47
Technical specification
Product dimensions
Packing list
Quality certification

Communication protocol
HG6000 common problem troubleshooting table
Appendix
CHAPTER 1
Safe Usage Instruction

Communication protocol
HG6000 common problem troubleshooting table
Appendix
CHAPTER 1
Safe Usage Instruction

2
The HG6000 humidity generator is a precision instrument. Safety precautions must be observed during all stages of using this
instrument. The company shall not be liable for any abnormal operation, damage or indirect economic losses caused by failure
to observe these safety measures or other warnings or instructions in this manual.
Safe Usage Instruction
Please use this instrument in accordance with the provisions of this manual, otherwise the protection provided by this
instrument may be damaged and it will not be safe to use.
Check whether all safety precautions have been taken. Before turning on the power, supply and select the appropriate
voltage in the fuse module, make sure to connect all equipment.
General principles
Before turning on the power
Ground the instrument
Operating environment
The standard wire of the instrument is a three-core wire, which is connected to the live wire, the ground wire and the
neutral wire respectively. Interrupting the connection of the protection (ground protection terminal) will result in a potential
electric shock hazard, resulting in personal injury.
3
Only qualified, maintenance-trained professionals who understand the potential hazards can open the housing.
Before removing the housing, be sure to disconnect the power supply and external circuits.
Professional maintenance personnel not belonging to or authorized by our company are not allowed to repair,
modify with substitute parts or adjust the instrument by themselves. If the instrument is abnormal,
please contact your supplier for repair and replacement.
Once the instrument shows signs of damage or malfunction, immediately stop operation and prevent operation by mistake,
and wait for maintenance personnel to repair it.
If water damage happens, the power supply should be cut off immediately; if the instrument fails to work,
please return the equipment to the dealer or the original factory for inspection and repair in time.
When the service life of the instrument is over, please return the electronic waste to our company to jointly support the
environmental protection regulations of electrical appliances.
Don't remove the housing
Don't adjust the instrument
When damage appears
Water damage
WEEE
Do not use this instrument in places with explosive, flammable gas, steam or smoke. Operating temperature: 5°C~50°C
storage temperature: -20°C~70°C; maximum humidity: 5%RH~95%RH (no condensation).
Please don‘t use this instrument in an environment that exceeds the temperature and humidity range.
Before using this instrument, please read carefully the safe usage instructions.
CHAPTER 1 Safe Usage Instruction CHAPTER 1 Safe Usage Instruction

2
The HG6000 humidity generator is a precision instrument. Safety precautions must be observed during all stages of using this
instrument. The company shall not be liable for any abnormal operation, damage or indirect economic losses caused by failure
to observe these safety measures or other warnings or instructions in this manual.
Safe Usage Instruction
Please use this instrument in accordance with the provisions of this manual, otherwise the protection provided by this
instrument may be damaged and it will not be safe to use.
Check whether all safety precautions have been taken. Before turning on the power, supply and select the appropriate
voltage in the fuse module, make sure to connect all equipment.
General principles
Before turning on the power
Ground the instrument
Operating environment
The standard wire of the instrument is a three-core wire, which is connected to the live wire, the ground wire and the
neutral wire respectively. Interrupting the connection of the protection (ground protection terminal) will result in a potential
electric shock hazard, resulting in personal injury.
3
Only qualified, maintenance-trained professionals who understand the potential hazards can open the housing.
Before removing the housing, be sure to disconnect the power supply and external circuits.
Professional maintenance personnel not belonging to or authorized by our company are not allowed to repair,
modify with substitute parts or adjust the instrument by themselves. If the instrument is abnormal,
please contact your supplier for repair and replacement.
Once the instrument shows signs of damage or malfunction, immediately stop operation and prevent operation by mistake,
and wait for maintenance personnel to repair it.
If water damage happens, the power supply should be cut off immediately; if the instrument fails to work,
please return the equipment to the dealer or the original factory for inspection and repair in time.
When the service life of the instrument is over, please return the electronic waste to our company to jointly support the
environmental protection regulations of electrical appliances.
Don't remove the housing
Don't adjust the instrument
When damage appears
Water damage
WEEE
Do not use this instrument in places with explosive, flammable gas, steam or smoke. Operating temperature: 5°C~50°C
storage temperature: -20°C~70°C; maximum humidity: 5%RH~95%RH (no condensation).
Please don‘t use this instrument in an environment that exceeds the temperature and humidity range.
Before using this instrument, please read carefully the safe usage instructions.
CHAPTER 1 Safe Usage Instruction CHAPTER 1 Safe Usage Instruction

5
HG6000 is a dual-flow humidity generator. Based on semiconductor constant temperature technology, various humidity
environments can be generated within a set temperature range. Built-in circulation pump and stirring fan can quickly
respond to the set humidity value. The stabilization time is less than 10 minutes, and the calibration and verification can be
completed in a short time.
The reasonable structure design can quickly respond and stably generate the required humidity, and provide excellent
uniformity.
About HG6000
CHAPTER 2
HG6000 Product Introduction
CHAPTER 1 Safe Usage Instruction

5
HG6000 is a dual-flow humidity generator. Based on semiconductor constant temperature technology, various humidity
environments can be generated within a set temperature range. Built-in circulation pump and stirring fan can quickly
respond to the set humidity value. The stabilization time is less than 10 minutes, and the calibration and verification can be
completed in a short time.
The reasonable structure design can quickly respond and stably generate the required humidity, and provide excellent
uniformity.
About HG6000
CHAPTER 2
HG6000 Product Introduction
CHAPTER 1 Safe Usage Instruction

Front view
6
Function description
7
View ID No. Function description
Part name
Seal inspection cabin, fix the inspected equipment
Verification hatch
①
②
③
④
⑤
⑥
① ②
③④⑤⑥
LCD display Main working screen, touch operation interface
Interface area of test instrument Data communication/signal collection
USB USB interface
Turn on/off
Power
Standard version compatible with ø12~19mm
1
2
3
4
5
67
8
9
10 1 Red +5V output
2 Black
GND
3
Brown
485-A
4 Orange
485-B
5 Yellow
TTL-T
6 Green TTL-R
7 Blue mAIN+
8 Purple mAIN-
9 Gray VIN+
10 White VIN-
NO. Color Signal
Dimension of verification window probe
Structure view and function description
Interface definition of test instrument
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction
NO. Color Signal

Front view
6
Function description
7
View ID No. Function description
Part name
Seal inspection cabin, fix the inspected equipment
Verification hatch
①
②
③
④
⑤
⑥
① ②
③④⑤⑥
LCD display Main working screen, touch operation interface
Interface area of test instrument Data communication/signal collection
USB USB interface
Turn on/off
Power
Standard version compatible with ø12~19mm
1
2
3
4
5
67
8
9
10 1 Red +5V output
2 Black
GND
3
Brown
485-A
4 Orange
485-B
5 Yellow
TTL-T
6 Green TTL-R
7 Blue mAIN+
8 Purple mAIN-
9 Gray VIN+
10 White VIN-
NO. Color Signal
Dimension of verification window probe
Structure view and function description
Interface definition of test instrument
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction
NO. Color Signal

①
②
③
④ ⑤ ⑥ ⑦⑧ ⑨
10
11
View NO. Function description
Connect power cable
Switch “-”to turn on; switch to“O”to turn off
Part name
①
②
③
④
⑤
⑥
⑧
⑨
⑦
Desiccant cartridge cover
Unscrew the cover of the desiccant cartridge,
take out the built-in drying chamber,
and replace the internal desiccant
10
11 Handle For moving the instrument
Power switch
Power connection
Vents
Water port
LAN interface
USB
COM RS232/RS485 interface
USB interface
LAN
Add /Drain water
Used for cooling
External expansion test cabin interface Used to expand the test cabin to adapt to special needs
Expansion desiccant interface External desiccant, good for using the instrument for a long time
89
Rear and side view Function description
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction

①
②
③
④ ⑤ ⑥ ⑦⑧ ⑨
10
11
View NO. Function description
Connect power cable
Switch “-”to turn on; switch to“O”to turn off
Part name
①
②
③
④
⑤
⑥
⑧
⑨
⑦
Desiccant cartridge cover
Unscrew the cover of the desiccant cartridge,
take out the built-in drying chamber,
and replace the internal desiccant
10
11 Handle For moving the instrument
Power switch
Power connection
Vents
Water port
LAN interface
USB
COM RS232/RS485 interface
USB interface
LAN
Add /Drain water
Used for cooling
External expansion test cabin interface Used to expand the test cabin to adapt to special needs
Expansion desiccant interface External desiccant, good for using the instrument for a long time
89
Rear and side view Function description
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction

11
Device information bar
Function description
Display brand, instrument name, current year, month, day and time, etc.
Standard display area
Status display area
Set value display area
Functional operation area
Shortcut operation area
Display the humidity value of the built-in reference sensor
Display control humidity and temperature target value; click this area to enter the target value
Programming and start/stop operation
Part name
Main interface function description
Set the type of analog/digital signal
The shortcut keys from top to bottom are: [Storage] to view the storage status;
[Calibration] to calibrate the humidity value; [Control] to adjust parameters;
[Lock] to lock the current humidity value; [Screenshot] to capture the current screen image;
[Settings] to enter the system setting
Display stable state time
Curve interface display area Display humidity and temperature curves
Signal display area of the
test instrument
Display icon and function description
Main interface icon
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction
10
Signal display area
of the test instrument
Standard display area
Device information bar
Curve interface display area
Set value display area
Shortcut operation area
Functional operation areaStatus display area

11
Device information bar
Function description
Display brand, instrument name, current year, month, day and time, etc.
Standard display area
Status display area
Set value display area
Functional operation area
Shortcut operation area
Display the humidity value of the built-in reference sensor
Display control humidity and temperature target value; click this area to enter the target value
Programming and start/stop operation
Part name
Main interface function description
Set the type of analog/digital signal
The shortcut keys from top to bottom are: [Storage] to view the storage status;
[Calibration] to calibrate the humidity value; [Control] to adjust parameters;
[Lock] to lock the current humidity value; [Screenshot] to capture the current screen image;
[Settings] to enter the system setting
Display stable state time
Curve interface display area Display humidity and temperature curves
Signal display area of the
test instrument
Display icon and function description
Main interface icon
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction
10
Signal display area
of the test instrument
Standard display area
Device information bar
Curve interface display area
Set value display area
Shortcut operation area
Functional operation areaStatus display area

Display curve
Display the humidity value measured by the instrument
The color of the value turns green to indicate stable state
Curve interface display
Display the height of the liquid level in the instrument
Standard measurement value Display the humidity value measured by the instrument
Perform start/stop operation
Display the set temperature value, click to set
Programmable control, setting of step and stabilization time;
setting of calibration point, stabilization time and error judgment, etc.,
to perform automatic calibration
Display the relative difference between the currently measured humidity value and
the set value
Temperature setting
Temperature setting
Start/Stop
Programming
Display the measured stabilization time
Display the set humidity value, click to set
12 13
Liquid level display
Stable state reminder
Display current running status
Control status display Signal display area of the
test instrument
Humidity measurement icon and description Measurement function icon and description
CHAPTER 2 HG6000 Product Introduction CHAPTER 2 HG6000 Product Introduction
Function description
Part name
Temperature measurement Stable state reminder
Curve interface display
Liquid level display
Standard
measurement value
Control status display
Function description
Part name
Measuring stabilization time
Temperature setting
Humidity setting
Start/Stop
Programming
Measuring stabilization time
Signal display area of the
test instrument
Temperature measurement
Table of contents
Popular Portable Generator manuals by other brands

Briggs & Stratton
Briggs & Stratton 18KW Home Generator System Installation & start-up manual

Ulvac
Ulvac EMP-14W instruction manual

Real Power
Real Power RP050 owner's manual

Robin
Robin RGV2200 Service manual

SDMO
SDMO HX 3000 Generating set user and maintenance manual

Generac Power Systems
Generac Power Systems GP Series owner's manual